Dräger Polytron Pulsar 2 Open Path Gas Detector

Similar documents
Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger REGARD -1 Control System

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

Dräger PIR 7200 Toxic Gas Detection Transmitter

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Catalytic Bead DrägerSensors for Fixed Gas Detectors

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger REGARD -1 Control System

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger PIR 7000 Flammable Gas Detection

Dräger Flame 2500 (IR3) Flame Detection

Dräger Flame 2500 Flame Detection

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger Flame 2100 Flame Detection

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger REGARD -1 Control System

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Dräger GS01 (wireless) Detection of flammable gases and vapours

Dräger Polytron 7000 Detection of toxic gases and oxygen

Dräger PIR 7200 Detection of toxic gases and oxygen

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger Flame 2100 (UV) Flame Detection

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 5720 IR Detection of carbon dioxide

Electrochemical (EC) DrägerSensors for Fixed Gas Detectors

Dräger Flame 2370 (UV&IR) Flame Detection

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger PEX 3000 Flammable Gas Detection

Dräger X-am 5000 Multi-Gas Detection

GS01 (wireless) Detection of flammable gases and vapours

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 7000 Fixed gas detector

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron 5700 IR Detection of flammable gases and vapours

The SharpEye 40/40I (IR3) Flame Detection

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger REGARD 3900 Series Control System

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger Flame 5000 Flame Detection

Dräger X-zone 5500 Area Monitoring

Dräger Polytron 8310 Stationary gas detector (DSIR)

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Dräger QuadGard Control System

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Dräger Pac 3500 Single-Gas Detection Device

Dräger Pac 6000 Single-Gas Detector

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions!

Dräger X-am 2500 Multi-Gas Detector

Dräger Pac 8500 Single-Gas Detector

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Flame 5000 Flame Detection

Dräger X-am 5000 Multi-Gas Detection

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Catalytic Ex-Sensors DrägerSensors

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

The SharpEye 40/40M (Multi IR) Flame Detection

Dräger X-am 2500 Multi-Gas Detection

The SharpEye 40/40I (IR3) Flame Detection

The SharpEye 40/40R (IR) Flame Detection

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

ST More than the sum of their components GAS DETECTION SYSTEMS

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

Dräger X-dock 5300/6300/6600 Calibration and Bump Testing

Dräger X-am 5000 Multi-Gas Detector

Dräger X-zone 5500 Area Monitoring

Dräger Pac 5500 Single-Gas Detection Device

Dräger X-am 7000 Multi-Gas Detection

Dräger X-am 7000 Multi-Gas Detection

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

Dräger X-pid 9000 / 9500 Multi-Gas Detection

Dräger Pac 6000 Single-Gas Detection Device

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions!

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger Pac 8000 Single-Gas Detection Device

Dräger Pac 3500 Single-Gas Detection Device

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

Dräger Pac 8500 Single-Gas Detection Device

Dräger Polytron SE Ex Fixed Gas Detector

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Model D12-IR. Digital Gas Transmitter...

Dräger UCF 7000 Thermal Imaging Camera

SIMRAD GD10 IR GAS DETECTOR

SIMRAD GD10PE IR GAS DETECTOR

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700S

SIMRAD GD10L - IR GAS DETECTOR OPERATING MANUAL

Dräger DM-6 BG 4 Mask Dryer Workshop Systems

SEC Millenium Hydrocarbon Gas Detector

Dräger X-zone 5500 Multi-Gas Detection Device

Transcription:

Dräger Polytron Pulsar 2 Open Path Gas Detector The Dräger Polytron Pulsar 2 represents the latest infrared technology in open path gas detection. Equipped with all the same functions as the standard Dräger Pulsar, Dräger Pulsar 2 is fitted with an ABS molded cover and comes with either a junction box or certified connector to provide installation flexibility. Lens protection cover ABS molded cover EEx e certiied junction box (ATEX) ST-3932-2005

02 Dräger Polytron Pulsar 2 Benefits Easy adjustment and commissioning Designed for one person installation and commissioning the Pulsar does not require specialized training. Through use of a hand-held terminal the Pulsar transmitter and receiver can be accurately aligned, gas level zeroed and commissioned with maximum efficiency. The factory calibration of the Polytron Pulsar makes manual setting and test gas superfluous. High performance The Pulsar receiver communicates to the transmitter via a digital link which allows the receiver to identify and adjust to difficult environmental conditions. The microprocessor built into the receiver unit instructs the transmitter unit to increase the flash rate for increased performance and accuracy. The Polytron Pulsar is immune to influences such as sunlight, gas flares, arc welding or resonance effects due to vibrations of rotating parts, as well as to environmental influences such as mist, drizzle or snow. The flash rate is also increased upon the detection of gas to ensure both accuracy and fast response. System stability The detector is designed so that no fault remains undetected. During normal operation, the output signal is between 4 to 20 ma, depending on the measured gas concentration. A signal of < 1 ma represents a fault due to a constant beam block or hardware failure requiring immediate attention. However, a signal of 2 ma identifies a beam block and will go to fault if this persists for more than 60 minutes. The Pulsar will also output a 3.5 ma signal to indicate pre-warning where the optics may be dirty or mis-aligned. During the period which the Pulsar displays 'Pre-warning' it will still detect gas allowing the customer to schedule maintenance on the detector therefore reducing down time. The Polytron Pulsar is suitable for SIL 2 rated systems. DrägerSensor technology High sensitivity, long term stability and no false alarms are the hallmark of the new and improved third generation of sensors. Sensors are the keystones of any gas detection system. Fastest response to the target gas combined with minimal interference by other gases or environmental influences (no false alarms) as well as the sensor life-time determine the reliability and the operating cost of a system. Heated optics Regulated internal lens heaters protect against build up of ice and snow under adverse weather conditions. They also prevent condensation on the lenses. In-built database The Receiver logs records and details a report of the last seven working days and a summary of the last 32 weeks. These reports contain important information such as measuring values, events such as "beam block" and gas alarms, warning signals, signal strength, adjustments, supply voltage and operating temperature.

Dräger Polytron Pulsar 2 03 Benefits HART-communication The HART-Communication of the Polytron Pulsar allows for digital communication between the explosion-proof and the secure areas. Without additional cabling, you can obtain real-time access to the status of individual detectors and to the configuration and historical data of each device. Extensive access to the secure area The optional AI500 Digital Interface can provide easy access to configuration, current measured values and the internal data-logger from a non-hazardous area through digital communication. For large and complex installations, up to 32 AI500's can be multidropped; therefore allowing access to up to 128 Pulsars useful for planning service and maintenance. System Components AI500 digital interface Digital interface for remote access to up to four Pulsars. Order no: 23 50 306 ST3531-2003

04 Dräger Polytron Pulsar 2 System Components Dräger REGARD 7000 When you need to monitor and analyze a number of various gases and vapors, the Dräger REGARD 7000 is a modular and highly expandable analysis tool. Suitable for gas warning systems with various levels of complexity and numbers of transmitters, the Dräger REGARD 7000 is exceptionally reliable and efficient. An additional benefit is the system's backward compatibility with legacy REGARD controllers. D-6806-2016 Accessories Tool set Remote control and foils for alignment and function test. Order No.: 23 50 325 ST-977-2001

Dräger Polytron Pulsar 2 05 Related Products Dräger PIR 7000 ST-11659-2007 Constant monitoring of flammable gases and vapors is essential for a safe workplace. The Dräger PIR 7000 is an explosion-proof point gas detection transmitter that uses infrared (IR) technology to continuously monitor flammable gases and vapors. With its stainless steel SS 316L enclosure and drift-free optics, this detector is built for the harshest industrial environments, including offshore installations. DrägerSensor IR Upgrade to infrared technology in an instant. The DrägerSensor IR can replace catalytic Ex sensors (catalytic bead sensors, pellistors) without additional installation work. ST-8821-2005

06 Dräger Polytron Pulsar 2 Technical Data Type Gases Range Factory calibration Operating distance Signal output Supply Voltage Power Consumption Response time t 95 Ambient conditions Enclosure Size (W x H x D, approx.) Weight (approx.) Approvals Exploscion proof Open Path gas detector utilizing dual wavelength infrared absorption technic Wide range of hydrocarbons including the alkane series from methane to hexane, propylene, ethanol and methanol From 0 to 4 up to 0 to 8 LEL*m Methane or propane, selectable. Other hydrocarbon gases on request 4 to 60 m, 30 to 120 m or 100 to 200 m, 13 to 197 ft, 98 to 394 ft or 328 to 656 ft separation of transmitter and receiver Analog Pre-warning Beam block Fault Measuring 4 to 20 ma 3.5 ma, dirty optics or misalignment 2 ma < 1 ma Digital HART ATEX UL, CSA 18 to 32 VDC 18 to 27 VDC Max. 0.95 A @ 24 V, with full heating and all source lamps operating < 2 s Temperature -40 to +60 C, -40 to +140 F Pressure Humidity IP 66, stainless steel 260 x 340 x 220 mm, 10.25" x 13.3" x 8.5", each 6 kg, 12.2 lbs, each 800 to 1100 hpa, 23.6 to 32.5 inch Hg 0 to 100 %RH, non-condensing ATEX II 2GD EEx d [ia] IIC T6/T5, -40 to +40 / +60 C IECEx Ex d [ia] IIC T6/T5, -40 to +40 / +60 C UL CSA, NRTL/C Class I, Div 1, Group C, D Class I, Div 1, Group C, D Ordering Information Dräger Polytron Pulsar 2 variations by max. operating range and approval transmitter and receiver, each fitted with an ABS moulded cover. Supplied with EEx e junction box or EEx d certified plug and socket. Dräger Polytron Pulsar, 60m / 197 ft ATEX certified with JB 23 50 493 Dräger Polytron Pulsar, 120m / 394 ft ATEX certified with JB 23 50 494 Dräger Polytron Pulsar, 200m / 656 ft ATEX certified with JB 23 50 495 Dräger Polytron Pulsar, 60m / 197 ft ATEX certified with EEx d plug and socket Dräger Polytron Pulsar, 120m / 394 ft ATEX certified with EEx d plug and socket Dräger Polytron Pulsar, 200m / 656 ft ATEX certified with EEx d plug and socket Accessories 23 50 496 23 50 497 23 50 498 AI500 digital interface 23 50 306 Alignment kit with HHT, test cards and ball driver with case 23 50 325 Adapter AI500 to HHT or PC 23 50 326

Dräger Polytron Pulsar 2 07 Ordering Information Dräger Polytron Pulsar PC software with cable (supports Dräger Polytron Pulsar, AI500 and HHT) 23 50 327

08 Dräger Polytron Pulsar 2 Notes Not all products, features, or services are for sale in all countries. Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released. Go to www.draeger.com/trademarks to find the current status. 91 03 415 17.03-1 HQ PP Subject to modifications 2017 Drägerwerk AG & Co. KGaA CORPORATE HEADQUARTERS Drägerwerk AG & Co. KGaA Moislinger Allee 53 55 23558 Lübeck, Germany www.draeger.com Customer Service: USA +1 800-4DRAGER (+1 800-437-2437). CANADA +1 877-DRAGER1 (+1 877-372-4371). Technical Service: USA +1 800-4DRAGER (+1 800-437-2437). Locate your Regional Sales Representative at: www.draeger.com/contact