Liquid Helium Level Instruments

Similar documents
Model OEM-2 INSTRUCTIONS FOR USE

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

AS950 REFRIGERATED SAMPLERS

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Tri-Tech Medical Inc.

Public Safety DAS Annunciator Panel

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Model 1062 Environment Monitor

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

AS950 PORTABLE SAMPLERS

ELD500 PRECISION LEAK DETECTOR

DGC-500 DIGITAL GENSET CONTROLLER

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

108A OTP1800. Grid Support. General Description

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

TECHNICAL DATA OBSOLETE

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

Model 17A00 Expansion Enclosure

Med Touch Combination Alarm Conversion Kits

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Vacuum Measurement and Control Product Guide

SECTION POWER SUPPLIES AND DISTRIBUTION

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Temperature Controllers

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

ACCURATE ELECTRONICS INC

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603

Ronan Model X96S Series Density System

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

DGC-1000 DIGITAL GENSET CONTROLLER

ANALOX 3000 Carbon Monoxide Monitor

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Ronan Model X96S Series Weighing System

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Model 6495 Freezing Rain Sensor. User's Manual. All Weather Inc National Drive Sacramento, CA USA

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

UDC100 Universal Digital Controller Specifications

Nardalert S3 TM Non-Ionizing Radiation Monitor

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

RTD TEMPERATURE SENSING SYSTEM

Advanced Test Equipment Rentals ATEC (2832)

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

DIESEL Engine Fire Pump Controllers Features

EZT Series Integra Med Touch Area Alarm & Zone Valve Box with EZ Backfeed

Sierra Series 900 Single & Dual Channel System. Instruction Manual

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

APPLICATION DATA SHEET

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

June 10, 2002 DF C S2424

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

MEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

KEM Scientific, Inc. Instruments for Science from Scientists

SAM-MAX Refrigerant Monitors

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

July 14, 1999 DF C-100.

SBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present

Series 9000 Total Hydrocarbon Analyzer

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection.

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

vacuum FLOW support excellence experience

The Kryos LN2 Liquid Level Control & Cryogenic Temperature Control

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Mark 25 Ultrapure Water Conductivity Analyzer

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

SEC 2000 Millenium Infrared Gas Detector

Spectron LSN (Life Safety Network) Suggested Specifications

MODEL B2 INSTALLATION MANUAL

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Oxygen Analyzer Manual

Rack Mount Series Installation Guide

Centro-Matic Automated Lubrication Systems System Controls

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

RELEASE DEVICE CONTROLS

Pioneer-R16 Gas Monitor Operator s Manual

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

APPLICATION DATA SHEET

Speed and Frequency Seite 1 von 7

vibration switch

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

AlarmLine Linear Heat Detector

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

900MAX PORTABLE SAMPLERS

EnvironmentalMonitoring

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Section PERIMETER SECURITY SYSTEMS

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

Modline. 5 Stand Alone Temperature Sensor. You can bet your process on it!

GasAlertMicroClip X3 Specifications

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Transcription:

Liquid Helium Level Instruments Versatile Reliable Affordable AMI American Magnetics, Inc. Excellence in Magnetics and Cryogenics

Model 135 Liquid Helium Level Monitor... Sample-and-Hold Level Sensing The AMI family of liquid helium level instruments offer a wide range of solutions. All instruments pass a constant current through a superconducting Niobium Titanium (NbTi) filament and measure the resistance. The portion of the filament in liquid helium becomes superconducting (i.e. no resistance). The resulting resistance of the wire above the liquid is converted to a level signal. Advanced circuit designs offer our customers many advantages. Years of trouble free service are the result of rugged construction both inside and out. All our instruments and sensors from 1 to 36 are stock items for quick delivery. Our experienced staff offer prompt repair service when needed. OEM instrument design and manufacturing partnerships are always welcomed if our standard products do not meet your needs. The Model 135 incorporates all of the features described below. Not all sample-and-hold monitors are alike. AMI s patented circuit design (U.S. Patent No. 3,943,767) energizes the level sensor for the minimum amount of time required to obtain an accurate reading and automatically adjusts for any level sensor length, unlike other designs which energize the sensor for a fixed time interval. This ensures the least possible heat transfer to the liquid helium. High/Low alarm setpoints activate front panel LED warning indicators, audible alarms, and rear panel relay contacts. The audible alarms can be silenced from the front panel. The High/Low triggers are set by the user from the front panel from 0-100% of the level-sensor active length. Internal relay contacts are normally-open and accessed from the rear panel connector. Microprocessor-based electronics are accurate to within 0.5% or better of the sensor active length. Watchdog timer circuitry and low line voltage (brownout) detector prevent microprocessor lock-up and provide fail-safe operation. The use of 4-wire level sensors ensures accuracy by eliminating differing lead wire resistance that can be seen as a false signal on 3-wire devices. Can be used with liquid helium level-sensors up to 80 inches. Selectable continuous measurement or sample-and-hold modes with sample update switch. Fully adjustable sample intervals from 0-600 minutes or hours. The user can set sample interval from the front panel without the use of DIP switch settings. Level sensor burn-out protection detects excessive sensor resistance and de-energizes the sensor current before burnout can occur. Burn-outs can occur when a level reading is attempted in a vacuum environment without liquid helium on the sensor to dissipate the heat. Monitors are easily reconfigured for different sensor lengths from the front panel. Ultra-fast circuit takes multiple samples each second in the continuous mode and updates the display every 200 milliseconds. EEPROM maintains monitor calibration without the need of battery backup. AMI level monitors use internal power supplies and standard removable IEC320 computer line cords. This makes moving and keeping up with your instrument easy. Rugged metal chassis design can withstand years of abuse. The de-icing/dirty sensor feature gives the user an option to increase the sensor current for a short time at the beginning of each sample. This feature is sometimes useful for removing ice or other deposits from a sensor that may cause false readings. A floating sensor power supply provides safe operation by eliminating the possibility of a ground path between the sensor and dewar. Rack-mount kit easily converts table top monitors to single or side-by-side 19" x 3.5" EIA mounting. This option is supplied on the original monitor or can be field installed at a later date. Items included Sensor input mating connector IEC 320 power cord Available options Computer interface: RS-232C or IEEE-488 Outputs: 0-10 Vdc or 4-2 0mA current loop Rack mounting

Model 136 Liquid Helium Level Controller... Sample-and-Hold Level Sensing +Automated level control functions+ The Model 136 incorporates all of the features of the Model 135, plus an added level control function. The Model 136 controller is designed for use in unattended liquid helium level control systems. Two independent setpoints A and B are set by the user from the front panel from 0-100% of the level sensor active length. When the liquid helium level drops to the B setpoint, the rear panel power receptacle is energized until the liquid helium level reaches the A setpoint. The controller output voltage is the same as the input AC line voltage. Liquid Helium Level Sensors... Flexible Sensor Rigid G-10 Sensor AMI offers a full line of 4-wire liquid helium level sensors that are rugged and offer low liquid helium consumption. Standard and custom designs are available. Standard AMI sensors are constructed of 1/4" G-10 phenolic tubing with optional sizes of 3/16", 3/8" and 1/2" available. Flexible sensors of 5/16" diameter tubing are standard items for applications where the sensor must conform to the curvature of a horizontal axis dewar such as MR systems. Standard lead wires are 28 AWG Teflon insulated copper wire. Standard sensor lead wire length is 6 inches with longer lengths and lead wire types available upon request. 1/2 in. 1/2 in. Active length TOP BOTTOM NEXT DAY SENSOR SHIPMENTS! AMI stocks 1/4 OD rigid sensors in active lengths from 1 to 36 in increments of 1. Custom sensors are available upon request (metallic sleeves, custom connectors, etc.).

Model 110A Liquid Helium Level Meter... Economic Level Sensing This rugged economical design is a classic. With a quick flip of the switch a user can easily determine the level of liquid helium in their dewar. A large analog display clearly shows the level from 0-100% and is easily read from a distance. The Model 110A can be used with any AMI liquid helium level sensor up to 60" and comes with a standard 0-10 V recorder output on the rear panel. Items included Sensor Input mating connector IEC 320 power cord Available options Rack mounting Portable Solutions... Model 150A Portable Liquid Helium Level Meter The Model 150A is ideal for use with helium storage dewars on loading docks, in storage rooms, or in remote locations were line power is unavailable. This meter works with any AMI 4-wire helium sensor up to 60 inches active sensing length. The hand-held meter has a 3.5 digit LCD readout and an accuracy of 0.5%. Power is provided by a sealed lead/acid battery pack. The battery can be charged to 70% capacity within 5 hours. A fully charged battery is good for hundreds of readings and can be stored for up to one year, at room temperature, before recharging is needed. Items included: Sensor input cable with mating connector Battery charger Sealed lead/acid battery Model 160 Liquid Helium Point Sensing Dipstick The Model 160 is designed for measuring the level of liquid helium in storage dewars. A superconducting point sensor is mounted on the end of a 72 inch x 1/4 inch phenolic extension tube. The user can choose two modes of operation to detect the liquid level. In the liquid detect mode the sensor is lowered into the dewar and an audible alarm and LED will energize when contact is made with the liquid. In the gas detect mode the dipstick can be fixed at a predetermined level in the liquid helium. When the sensor becomes exposed to the gas the alarms will be energized. The Model 160 is powered by one standard 9 volt battery. This device offers highly accurate level determination and is an excellent alternative to unreliable flutter tubes or carbon resistor devices. Items included: 9 volt battery 72 x 1/4 extension tube with point sensor 6 feet of cable and mating connector

Specifications... Liquid Helium Level Meters and Monitors Model 110A Model 135 Model 136 Level Range 0-60 inches 0-80 inches 0-80 inches Display Type analog meter 3.5 digit LED 3.5 digit LED Electronic Display ±2% of full scale ±0.1% of active sensor length ±0.1% of active sensor length Input Power 115/230 or 100/200 VAC 115/230 or 100/200 VAC 115/230 or 100/200 VAC ±10%, 50-60Hz ±10%, 50-60Hz ±10%, 50-60Hz Readout Units % only %, inches, or cm %, inches, or cm Sample Interval Time N/A 0-600 minutes or hours 0-600 minutes or hours Alarms N/A audible + LED audible + LED Alarm Relay N/A normally-open 10 VA normally-open 10 VA Contact Rating @.5A max. current @.5A max. current Controller Output N/A N/A 1 A max. @ AC line voltage Signal Output 0-10 V standard 0-10 V or 4-20 ma 0-10 V or 4-20 ma Options (0-100 mv optional) Dimensions 3.8" x 8.4" x 10.75" 3.8" x 8.4" x 10.75" 3.8" x 8.4" x 10.75" H x W x D standard standard standard 3.5" x 19" x 10.75" 3.5" x 19" x 10.75" 3.5" x 19" x 10.75" rack mount rack mount rack mount Weight 4.0 lbs. standard 4.3 lbs. standard 4.3 lbs. standard 4.7 lbs. rack mount 5.0 lbs. rack mount 5.0 lbs. rack mount Operating 15-50 C non-condensing 15-50 C non-condensing 15-50 C non-condensing Environment Portable Liquid Helium Level Devices Model 150A Level Meter Model 160 Point Sensing Dipstick Level Range 0-60 inches 72" extension, 0.1" point sensor Display Type 3.5 digit LCD audible and LED alarms Electronic Accuracy ±0.5% of full scale ±0.1 inch Input Power sealed lead-acid battery pack with wall mount recharger standard 9 volt battery Dimensions 6.25" H x 3.13" W x 2.25" D 1.5" H x 2.5" W x 4.25" D Weight 2.0 pounds (including battery) 12 oz. (including battery) Operating Environment 15-50 C non-condensing 15-50 C non-condensing Liquid Helium Level Sensors Active Overall Lead Wire Sensor Sensor Lengths Length Length Current Resistance Diameters G-10 Stick 1-80" active +1" 6" standard 75 ma 11.4 Ω/in. @ 20K 3/16" 13.3 Ω/in @ 300K 1/4" standard 3/8" Flexible Tubing 1-80" active +2" 6" standard 75 ma 11.4 Ω/in. @ 20K 5/16" 13.3 Ω/in @ 300K Miniature 1-80" active +1" 6" standard 75 ma 11.4 Ω/in. @ 20K 3/32" Flexible Tubing 13.3 Ω/in @ 300K

Liquid Helium Transfer Line with Built-In Level Sensor This innovative design incorporates a standard AMI liquid helium level-sensor into the lower 22 inches of the supply side transfer leg. This allows the user to monitor the decreasing helium level in the supply dewar and stop the transfer before hot gas is blown into the target dewar. Any AMI liquid helium level instrument can be used to monitor the level via the signal cable attached to a 4-pin electrical connector on the transfer line. The transfer line is vacuum jacketed with superinsulation, 60 inch dewar legs, a 60 inch flexible section and is designed such that the sensor is field replaceable. Items included Detachable vacuum evacuation valve Signal cable with mating connectors Integrated Level Sensor... Digital Computer Interface The computer interface options allow computer monitoring and control of the liquid level, sensor length calibration, high/low alarm setpoints, level control setpoints, and sampling interval. Computer interface options are supplied with free virtual instrument (VI) drivers for National Instruments LabVIEW software for Windows version 3.1 and above. Use of the RS-232 or IEEE-488 interface options do not require LabVIEW. The LabVIEW drivers can be completely customized by the user. For over 25 years, American Magnetics, Inc. has been a leading supplier of liquid helium level instruments and sensors. In addition, a complete line of instruments and sensors is offered for other cryogenic gases. Our instruments are used worldwide by thousands of users in a wide array of applications. Some of the applications include: Magnetics Resonance Imaging Systems Scientific Laboratories University Physics Departments Industrial Gas Producers and Distributors AMI s liquid helium level instrumentation is based upon measuring the resistance in a Nb-Ti superconducting filament. External communications and control options include 0-10 Volt recorder output, 4-20 ma output, and RS-232 or IEEE-488. AMI s affordable line of cryogenic level instruments are designed for maximum flexibility and years of trouble-free service. Custom products and system solutions can be designed for your specific needs. Our worldwide network of sales engineers provide local service. For further information please call or visit our World Wide Web site. AMI American Magnetics, Inc. Excellence in Magnetics and Cryogenics P.O. Box 2509 112 Flint Road Oak Ridge, TN 37831-2509 Phone: (423) 482-1056 Fax: (423) 482-5472 E-mail: sales@americanmagnetics.com Visit AMI on the Web at http://www.americanmagnetics.com