Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

Similar documents
Product Number L4006A1017 L4006A1132 L4006A1967 L4006A2007 L4006B1007 L4006B1155 L4006B1163 3/4 (19) L4006H1004

Single and Multi-Function Aquastat Controllers

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

Powers Controls ET 134 Low Temperature Detection Thermostat

A11 Series Low Temperature Cutout Controls

Temperature & Humidity Controllers

TC-5231 Series, TC-5232, & TC-5241 Series

THERMOSTATS THERMOSTATS HEATING AND COOLING

Powers Controls Low Temperature Detection Thermostat

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Table of Contents. Part Number Index SANDYS INDUSTRIAL GLASS WHEELER A

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

ProRadiant Controls, Valves and Actuators

TEMPERATURE & PRESSURE CONTROLS

temperature Controllers

Tubular Industrial Process

AQ475A Aquatrol Outdoor Temperature Compensator for Boilers

Technical Instructions Document No P25 ET September 28, ET 141 Electric Surface Mounted Thermostat.

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

270XT Freeze Protection, IP30

Tubular Industrial Process

Instruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules

The T6140A,B Remote Bulb Temperature Controller

T834C Heating-Cooling Thermostat

L8151A Triple Aquastat Relay

IS Series Pressure Sensing Switches

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Davies Is Your #1 Source For Temperature Controls

T7079A,B Solid State Remote Temperature Controllers

Dual Pressure Controls

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

59T, 66T Series Electric Water Heater Controls

Schneider Electric Erie T155 Series

L Honeywell. L4068 has spst switch; L6068 has spdt switch. L4068A,C,E,F have adjustable FAN OFF and differential settings.

Thermostatic Radiator Valves (Caleffi)

ADJUSTABLE CONTROLS WHO WE SERVE

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

Installation & Operation Manual

Installation & Operation Manual

HEATING- Heating Accessories RW List Prices Page X - 1. Iron Body Red Fox B&G Circulator Pump. Bronze B&G Circulator Pumps

Series A28 Two stage Thermostats. Feature and Benefits

59T, 66T Series Electric Water Heater Controls

MR3CCUHV Temperature/Defrost Control

Two-Position Electric Duplex Room Thermostats

Indirect Fired Water Heater

HEATING- Heating Accessories RW List Prices Page X - 1. Bronze B&G Circulator Pumps. Iron Body Red Fox B&G Circulator Pump

Replacement Parts List For Models COS-20G

Thermostat KPU. Data sheet

HWE-SS DIGI-El i t e Hydronic Single-Stage Boiler Control

qualified heating installer/service technician

Brasch Hazardous Location Unit Heaters

- Data Brochure Universal Reset Module 422

Features & Benefits. Description. Example of LCD display screen. Functionality. Ordering Information: Model 7600 Boiler Control

2 shp 13 lc 1 36 t - 1 a

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

Taco 00 Series Cartridge Circulators

Installation & Operation Manual

A19, A28 Series Thermostats for Agricultural Buildings

Temperature, Mechanical

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Powers TM Controls TH 188 Unit Mounted Thermostat

CP CP

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Installation. Part Number /0209

Outdoor Reset IQ Option Card, p/n

- Data Brochure Boiler Control 274

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

Thermostat Catalog 2004

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA

- Data Brochure Universal Reset Module 423

be liable for any other loss or damage, whether direct, indirect, incidental or consequential.

Installation & Operation Manual

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 14 Automatic Control Components and Applications

Capillary & Bulb Thermostatic Control & Fail-Safe Limit

- Data Brochure Steam Control 279

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

When ordering, please state type and code number. Max. Type - Capillary sensor of tube temp. charge length. C m

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Table of Contents. Installation, Operation, and Maintenance Manual V100 Series

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

HYDRO-AIR ZONING CONTROLS ARH-1, ARH-2, ARH-3

Better Design, Better Control, Better Systems.

CURTIS Gemini 12 Brewer

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats

Aquatrol Outdoor Temperature Compensators AQ675A for Floating Control Valves AQ775A for Injection Pumps

PART NO. THROUGH THE ROOF VENT CAP

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand

HYDRO-AIR ZONING CONTROLS ARH-1, ARH-2, ARH-3

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

Scotsman Technical Training. CU50 Cube Ice Machine

OPTIMUM APPLIED SYSTEMS,

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

Effective october 14, 2014

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions.

Transcription:

16/05/08 Aquatrol Indoor/Outdoor Control B3 Adjustable settings for boiler maximum temperature, boiler minimum temperature and outdoor low (design) temperature Selectable Warm Weather Shut Down (WWSD) at 70F (21C) to prevent summer boiler operation Domestic Hot Water (DHW) priority Replaceable circulator relay common to other replacement controls Supply and outdoor sensors included Automatic boiler operating differential and system circulator exercising Long-life DC relay drive control technology Troubleshooting LEDs;push-to-test button; full size screw terminals Description Part Number 120 Volt Outdoor Compensation Control, includes 2 sensors AQ475A1004 Automatic Changeover Switch control provides automatic change over of thermostat to operate Zone valve on combination hot and chilled water systems Epoxy resin seal protects bimetallic disc and snap-action contacts from dust, dirt and corrosion Furnished with removable spring clop to attach control to tubing switch connects heating side of thermostat to two-wire zone valve when hot water is circulated through tubing switch connects cooling side of thermostat to two-wire zone valve when chilled water is circulated through tubing Curved sensing element provides maximum contact with tubing Electrical Connections: 12" red, brown and black leads, 105 o C insulated, No. 18 wire Red-Black: Open on rise @ 85 o F, close @ 70 o F Red-Brown: Close on rise @ 85 o F, open @ 70 o F Maximum Ambient : 221 o F For use with 1/2" tubing (5/8" OD) Full Load 7.5A @ 120Vac 3.75A @ 240Vac Motor Rating Locked Rotor 45.0A @ 120Vac 22.5A @ 240Vac Pilot Duty 120/240/277 VAC Resistive (non-inductive) 120/240/277 VAC Part Number 125 VA 15A White Rodgers 752-1

06/02/15 B4 Direct Mount/Well Immersion Aquastat Controller Totally enclosed Micro Switch snap-acting switches operate on to setpoint Visible control point scale and external adjustment screw permit easy setting Horizontal or vertical insertion of the sensing element Direct or well immersion of the sensing element Remote bulb model may be used to sense air temperature in ducts and in outside air sensing applications L4006 L6006 (Operating Range) Spud Size Includes Part Number High or low SPST, contact break on 5F to 30F adj. 3C to 17C fixed 3/4" NPT 19mm NPT 1 1/2"(38mm) insulation L4006A1017 High or low SPST, contact break on 2F fixed 1C fixed 40F to 180F 4C to 82C 3/4" NPT 19mm NPT 1 /2" (38mm) Insulation and heat-conductive compound L4006A1959 SPST, contacts make on 5F fixed 3C fixed 1/2" 13mm 1 1/2" (38mm) insulation L4006B1007 control and high or low 5F to 30F adj. - Stop factory-set at 240F (116C); heat-conductive compound L6006A1145 High Limit SPST contact break on Manual reset 110F to 290F 43C to 143C - 2 7/8" (73mm) sensing bulb, stop factory-set at 240F (116C) horizontal or vertical mount L4006E1042

12/12/14 B5 Multiple-Function Aquastat Controller High and low circulator controller used to regulate boiler water temperature in gas or oil-fired hydronic heating systems Immersion type, liquid-filled sensing element actuates two snap switches, one for high and one for low. One SPST and one act independently at respective temperature settings Separate, easy to read calibrated dial and setpoint adjustments for each switch Controller may be mounted in any position and does not require leveling adjustment on low All adjustments accessible inside front cover Push terminals for quick connecting Single sensing element for easy installation High Limit Low Limit High Limit Low Limit -12C -12C to -3C Adjustable Operating Range Multiple-Function Aquastat Controller L8148A Insulation Depth Spud Size Part Number 54C to 116C 43C to 104C 1 1/2" to 4" 3/4" NPT L6081A1036 L8148E Immersion-type controller that combines high protection with switching relay control of burner and circulator motors High opens burner circuit only Select models include transformer and accessory terminals for adding a remote low controller Case available for horizontal or vertical mounting Combination of two insulation and two insertion well lengths are available Requires a 24 VAC thermostat with heat anticipator set at 0.2A TRADELINE models include well adapter, heat conductive compound and range stops L8148J has terminals for adding zone valve system wiring L8148J Horizontal & Vertical mountings Capillary Length Insulation Depth Mounting Part Number -13C / 8F SPST: High Limit & Horizontal/ Vertical L8148A1017-9C / 15F SPST: High Limit & Vertical L8148E1265-9C / 15F SPST: High Limit & Vertical L8148E1299-13C / 8F SPST: High Limit & Horizontal/ Vertical L8148J1009

06/02/15 Remote Bulb Aquastat Controller B6 Totally enclosed Micro Switch snap-acting switches operate on to setpoint Visible control point scale and external adjustment screw permit easy setting Horizontal or vertical insertion of the sensing element Direct or well immersion of the sensing element Remote bulb model may be used to sense air temperature in ducts and in outside air sensing applications (Operating Range) Electrical (Full Load) Includes Part Number High or low break on 5F to 3F adj. 1.3 A @ 240Vac 5 1/2 ft (1.7m) capillary L4008A1015 High or low break on 5F to 3F adj. 130F to 270F 54C to 132C 1.3 A @ 240Vac 10 ft (3.04m) Capillary; factory-set stop at 200F (93C) L4008A1130 make on 5F to 3F adj. 1.3 A @ 240Vac 5 1/2 ft (1.7m) capillary L4008B1013 High break on Manual reset 130F to 270F 54C to 132C 5.1 A @ 240Vac 5 1/2 ft.(1.6m) capillary; factory-set stop at 250F (121C) L4008E1156 control and low 3F to 30F adj. 5.1 A @ 240Vac 5 1/2 ft. (1.6m) capillary L6008A1192 Remote Ambistat Controller Ambient temperature compensated, high- controller for agriculture and industrial applications Suitable for line-voltage, low voltage or millivolt (Powerpile) control of bulk milk tanks, beverage dispensing machines, ice cube machines, dishwashers, crop drying, tobacco curing and similar applications Enclosed snap-action switches Screwdriver adjustment for temperature setting Immersion well not included Notes Maximum Operating Setpoint Range Output Bulb Size Capillary Length Sensor Element Includes Part Number Break on Temp. Rise 5F / 2.8C 205F / 96 40F to 180F 4C to 82C 1 SPST 2 7/8" L x 3/8" dia. 5.5ft Copper - T4031C1012-2F / 1.1C 205F/ 96C 40F to 180F 4C to 82C 2 7/8" L x 1 5.5ft 3/8" dia. Copper Bulb 107324A duct bulb holder T6031C1009

06/02/15 B6-1 Single-Function Aquastat Controller Operating Range 100F to 180F 38C to 82C Ranging (ECO) Energy Cutoff Strap On Aquastat Controller Immersion type controller for regulating and ing the tank temperature in water heaters Regulates temperature and provides energy cutoff (ECO) action on a past the set point. Includes a second sensing element that senses average water temperature to minimize stacking. Fluid-filled element operates Micro Switch SPST snap-acting switch ECO switch interrupts the thermocouple circuit or main valve before tank reaches 210F (99C) maximum temperature. Includes factory-installed immersion well on controller Internal adjustment screw and special switch terminal provides threewire hookup from Aquastat controller to gas valve. Capillary Length 190F 42" Insulation Depth Part Number Controller Well: 2 1/4" Remote Well: 1 1/2" or 2 1/2" L8100B1037 Totally enclosed Micro Switch snap-acting switches operate on to set point Visible control point scale and external adjustment screw permit easy setting Horizontal or vertical insertion of the sensing element Direct or well immersion of the sensing element Remote bulb model may be used to sense air temperature in ducts and in outside air sensing applications, high and low 5F to 30F adj. 2.8C to 16.7C adj. (Operating Range) 65F to 200F 18C to 93C Strap On Hot Water Control Includes Bracket for strap on mounting, stop factory-set at 200F (93C) Part Number L6006C1034 Surface type hot water control for direct or reverse action May be used as either an open high control or as an open low control Terminals are color coded to simplify installation May be mounted on either horizontal or vertical rise pipe Insulated back portion of case minimizes the effects of ambient temperature Automatic changeover control for fan coil systems Automatic changeover control for fan coil systems 10F fixed 5.6C fixed 15F fixed 8C fixed (Operating Range) 60F to 200F 16C to 93C Includes Clamp-on strap and convertible range adjuster Johnson Part Number A19DAC-1C Pipe strap and mounting screws White Rodgers 1127-9

16/05/08 B6-2 Aquastat Accessories Immersion Wells Immersion wells are used with Aquastat Controllers to hold the temperature sensing bulb in the controlled medium They also allow heat transfer while protecting the sensing bulb from contact with the controlled medium Immersion wells permit removal of the sensing bulb for testing or replacement without draining the system Spud in In. x 14 NPT Shell ID / Bulb Diameter Insertion Max Bulb Length Insulation Depth Capillary Diameter Includes Part Number Copper Immersion Wells 1/2" 3/8" 3" 1 1/2" - - 123869A 1/2" 1/2" 4" 1 1/2" 1/8" 112721 spring clip 112622AA 3/4" 3/8" 3" 1 1/2" 5/64" 121371 mounting clamp 121371B Stainless Steel Immersion Well 1/2" 1/2" 4 1/4" 1" 1/8" 112721 spring clip 112624AA 123869A (less mounting clamp) & 121371B (with mounting clamp) 112622AA & 112624AA Immersion Well Accessories 107408 107323A 107324A 311266D Description Part Number Heat Conductive Compound: Used to enhance contact and heat transfer in temperature sensor applications. Not for use above 149C (300F). 4oz. 107408 Bulb Shield Assembly for Duct Mount s: Shields bulb from weather. Does not include mounting screws and split plug. 6" Long, Holds 3/8" and 1/2" bulbs. Bulb Holder for Duct Mount s: Supports capillary and bulb in duct. Does not include mounting screws. 8 5/8" Long, 2 3/4" x 1 3/4" plate size. Bulb Holder for Duct Mount s: Holds 1 or 2 elements in 0 o F to 100 o F air, grommet holds one 5/64" and one 1/8" diameter capillary, helps reduce airflow through opening in duct. 14" Long, 3 1/4" x 3 1/4" plate size. 107323A 107324A 311266D