Fire Test Requirements for Upholstered Furniture Used in Public Buildings

Similar documents
UPHOLSTERED FURNITURE AND MATTRESSES IN NEW AND EXISTING BUILDINGS

NFPA 101 Life Safety Code Introduction for Fire Alarm, Security and Locksmith Qualifiers

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #5

ICC CODE CORNER 2015 International Fire Code

Global flammability standards.

Fire and Explosion lnvestigation and Litigation Support

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Report on Public Input June 2014 NFPA 101

TECHNICAL BULLETIN Weston Parkway, Cary, North Carolina, Telephone (919) FLAMMABILITY TESTING: A REVIEW BY COTTON INCORPORATED

Report on First Revisions with Statement June 2014 NFPA 101

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

UNDERSTANDING THE CHANGES TO CALIFORNIA TB ON FLAME RETARDANCE OF RESILIENT FILLING MATERIALS USED IN UPHOLSTERED FURNITURE

EC EP 14 All other electrical K-920 equipment in patient care vicinity NFPA , Chapter 10

RULES OF THE TENNESSEE DEPARTMENT OF INTELLECTUAL AND DEVELOPMENTAL DISABILITIES OFFICE OF LICENSURE CHAPTER LIFE SAFETY LICENSURE RULES

Public Health Fax: Web Site:

Public. Mike Free Health. State of Alabama Department of

Chapter 2: Definitions

State of California Department of Consumer Affairs Green Science Policy Workshop for Manufacturers and Retailers

Illuminating Label Laws 2015 Manufacturing Summit Franklin Furniture Institute Mississippi State University

The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101):

Emergency Planning for Institutional Facilities

Requirements. This Toolbox Talk has been created to assist you, and the user to assess the building Occupancy and classification.

RULES AND REGULATIONS OF THE SAFETY FIRE COMMISSIONER CHAPTER RULES AND REGULATIONS FOR THE STATE MINIMUM FIRE SAFETY STANDARDS

UL Conference Atlanta May 21 22, 2014 Polyurethane Foam Association presentation

DEALING WITH FIRE SAFETY

January 14, Via Electronic Mail to NFPA

Flame Retardant Science and the Furniture Industry: A Success Story. February 2015

Residential Based Care Facility Guidelines

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

NFPA 101 Life Safety Code Culture change 2012

Defend In Place 2012 IFC Overview of Institutional Occupancies

Report on First Revision June 2014 NFPA 101

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)

LIFE SAFETY COMPLIANCE: ADAPTING TO THE 2012 LIFE SAFETY CODE

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

First Revision No NFPA [ Section No ]

CODE TECHNOLOGIES COMMITTEE NURSING CARE FACILITIES WORK GROUP APPROVED CODE CHANGE DRAFTS CODE GROUP B

ICC CODE CORNER 2015 International Fire Code

Report on First Revisions with Statement June 2014 NFPA 101

ORDINANCE NUMBER


CEC CODE COMPLIANCE SEMINAR FOR ICC CHAPTER 8 INTERIOR FINISHES & DECORATIVE MATERIALS

Automatic Fire Sprinkler Systems New Construction Matrix

(House Bill 849) Public Safety Rental Dwelling Units Carbon Monoxide Alarms

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

Automatic Fire Sprinkler Systems New Construction Matrix

Changes to NFPA 101A 2013 Edition for Health Care Facilities

For additional information regarding Group I occupancies please call (951)

First Revision No. 6-NFPA [ Section No. 2.2 ]

Class 3 Test 1. What fabric would have the best appearance for the longest time when used in theater seating?

BUILDING CODE OF THE CITY OF NEW YORK. New York City Department of Buildings 4 June 2007

UL 94 Flammability Ratings: Introduction

Schools and the Fire Code A Partnership for Safety

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

January 1, 2014 Mandatory Effective Date

STATE OF MAINE Department of Public Safety Office of State Fire Marshal 52 State House Station Augusta, ME

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

Iowa (2) Delete section and insert in lieu thereof the following new section:

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

The New Life Safety Code & Texas Responds with New Small House Nursing Design Standards

Following are code change proposals submitted through Adhoc Health from General study group and related changes. General. Position.

Compliance w/ the 2012 Life Safety Code

97 FCV 006 Page 2 of 16 EXPLANATORY MATERIAL

A Comparison of Carbon Monoxide Gas Sensing to Particle Smoke Detection in Residential Fire Scenarios

FACT SHEET Program: Event Fire Safety

Residential-based Care Facility R2.1 Guideline

For additional information regarding R-3.1 residential care facilities please contact (951)

Residential-based Care Facility R-4 Guideline

EFFECTIVE DECEMBER 28, 2010 SECTION 610 CARBON MONOXIDE ALARMS

Retain. Retain. Retain. Board Advisory. Board Advisory. Retain. Disposition. (Statute, Rule, FBC, Industry)

Designers Guide. Design Approach Standards Shapes and Sizes Layouts

Fire Management Guide

PROPOSED CHANGE TO THE 2007 FIRE CODE (OFC)

DECLARATORY STATEMENT. THIS CAUSE came on for consideration upon the Petition for Declaratory

AD HOC HEALTHCARE COMMITTEE MEANS OF EGRESS WORK GROUP APPROVED CODE CHANGE DRAFTS CODE GROUP B MOE COMMITTEE

CHANGES TO THE TEXT OF THE 2010 CODE BOOKS

IMC Significant Changes Summary Tier I

Florida Building Code 2010

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

2000 to 2012 Hospital K-tag crosswalk matrix for hospitals 2000 Tag #

HOME FIRES THAT BEGAN WITH UPHOLSTERED FURNITURE

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

MEETING MINUTES NFPA Technical Correlating Committee on Safety to Life January 6, 2011 ROC Meeting The Wyndham Phoenix, Phoenix, AZ

CTC Meeting #27 JUNE 17 18, 2013 NIST report on the Charleston sofa store fire

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle)

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

Family Foster Home Fire Safety Evaluation Checklist Instructions

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION GUIDELINE RESIDENTIAL CARE FACILITIES 2007 CBC/CFC (R-3.1)

CIDA Curriculum Matrix - Miami University First Year

PRESENTERS OVERVIEW COMMUNITY WORKSHOP OVERVIEW OF THE 2010 EDITION OF THE CALIFORNIA BUILDING STANDARDS CODE AND LOCAL AMENDMENTS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

A Review of a White Paper on Residential Fire Sprinklers

Fire Test Methods ASTM NFPA UL ISO IEC

ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process

APPROVED: Dayroom: Space for activities that is situated immediately adjacent to the youth sleeping areas and separated from them by a wall.

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

Changes to Environment of Care, Equipment Management, and Life Safety Chapters Related to Life Safety Code Updates

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

Transcription:

INTRODUCTION In the U.S., there are two major fire safety codes: NFPA 101 Life Safety Code and the International Building/Fire Code. Both sets of codes specify fire tests for upholstered furniture. The fire test requirement for upholstered furniture is not normally based on the physical parameters of the building itself. The fire test requirement is dependent on the usage or occupancy of the building. Each code lists the various occupancies. The occupancy classifications are much easier to understand in using the NFPA 101 code. Therefore, the listed occupancies are taken from the NFPA 101 code. The occupancies listed under the International Fire Code are comparable to those listed under the NFPA 101 code except that the terminology differs. TABLE OF CONTENTS Page NFPA 101 Life Safety Code Listing of Occupancies & Required Tests 2 Occupancies as Listed & Defined by the NFPA 101 Life Safety Code 3 NFPA 260 (Cover Materials) Test Summary NFPA 260 (Cover Materials) Test Sketch NFPA 260 (Filling/Padding Components) Test Summary NFPA 260 (Filling/Padding Components) Test Sketch NFPA 261 Test Summary NFPA 261 Test Sketch (Actual) NFPA 261 Test Sketch (Mockup) ASTM E1537 Test Summary ASTM E1537 Test Sketch 5a 5b 6a 6b 7a 7b 7c 8a 8b Page 1

NFPA 101 LIFE SAFETY CODE LISTING OF OCCUPANCIES & REQUIRED TESTS Required Tests by Occupancy Sprinklered Non Sprinklered Ambulatory Health Care NFPA 260 or NFPA 261 ASTM E1537 (1) Assembly None None Business None None Day-Care None None Detention and Correctional NFPA 261 NFPA 261 (2) Dormitories NFPA 260 or NFPA 261 ASTM E1537 Educational None None Health Care NFPA 260 or NFPA 261 ASTM E1537 (1) Hotel NFPA 260 or NFPA 261 ASTM E1537 Industrial None None Lodging and Rooming Houses None None Mercantile Occupancies None None Residential Board and Care NFPA 260 or NFPA 261 ASTM E1537 (1) Storage None None (1) The International Fire Code will accept either ASTM E1537 or California Technical Bulletin 133. (2) The International Fire Code requires NFPA 260 or NFPA 261 plus ASTM E1537. The information contained in this bulletin is based on the Govmark interpretation of the NFPA 101 Life Safety Code, the International Building Code, and the International Fire Code. The user is directed to the codes to make their own determination. There are other standards issued by other jurisdictions and agencies such as California, Boston, and UFAC (Upholstered Furniture Action Council). Contact Govmark directly for information and applicability of other upholstered furniture fire tests. When selling to the contract market, it is highly recommended that the code requirement be considered irrespective of the occupancy. With specific reference to large seating areas such as auditoriums and theaters (even those that are fully sprinklered), ASTM E1537 is strongly recommended. Page 2

OCCUPANCIES AS LISTED & DEFINED BY THE NFPA 101 LIFE SAFETY CODE Ambulatory Health Care: An occupancy used to provide services or treatment simultaneously to four or more patients that provides, on an outpatient basis, one or more of the following: (1) treatment for patients that renders the patients incapable of taking action for self-preservation under emergency conditions without the assistance of others; (2) anesthesia that renders the patients incapable of taking action for self-preservation under emergency conditions without the assistance of others; (3) emergency or urgent care for patients who, due to their injury or illness, are incapable of taking action for self-preservation under emergency conditions without the assistance of others. (SAF-HEA) Assembly: Business: Day-Care: Detention and Correctional: Dormitory: Educational: An occupancy (1) used for a gathering of 50 or more persons for deliberation, worship, entertainment, drinking, eating, amusement, awaiting transportation, or similar uses; or (2) used as a special amusement building, regardless of occupant load. (SAF-AXM) An occupancy used for the transaction of business other than mercantile. (SAF-MER) An occupancy in which four or more clients receive care, maintenance, and supervision, by other than their relatives or legal guardians, for less than 24 hours per day. (SAF-END) An occupancy used to house one or more persons under varied degrees of restraint or security where such occupants are mostly incapable of self-preservation because of security measures not under the occupant s control. (SAF-DET) A building or a space in a building in which group sleeping accommodations are provided for more than 16 persons who are not members of the same family in one room, or a series of closely associated rooms, under joint occupancy and single management, with or without meals, but without individual cooking facilities. (SAF-RES) An occupancy used for educational purposes through the twelfth grade by six or more persons for 4 or more hours per day or more than 12 hours per week. (SAF-END) Page 3

Health Care: Hotel: Industrial: LIFE SAFETY CODE OCCUPANCIES (Continued) An occupancy used to provide medical or other treatment or care simultaneously to four or more patients on an inpatient basis, where such patients are mostly incapable of selfpreservation due to age, physical or mental disability, or because of security measures not under the occupants control. (SAF-HEA) A building or groups of buildings under the same management in which there are sleeping accommodations for more than 16 persons and primarily used by transients for lodging with or without meals. (SAF-RES) An occupancy in which products are manufactured or in which processing, assembling, mixing, packaging, finishing, decorating, or repair operations are conducted. (SAF-IND) Lodging and Rooming House: Mercantile: Residential Board and Care: Storage: A building or portion thereof that does not qualify as a one- or two-family dwelling, that provides sleeping accommodations for a total of 16 or fewer people on a transient or permanent basis, without personal care services, with or without meals, but without separate cooking facilities for individual occupants. (SAF- RES) An occupancy used for the display and sale of merchandise. (SAF-MER) An occupancy used for lodging and boarding of four or more residents, not related by blood or marriage to the owners or operators, for the purpose of providing personal care services. (SAF-BCF) An occupancy used primarily for the storage or sheltering of goods, merchandise, products, or vehicles. (SAF-IND) Page 4

NFPA 260 (COVER MATERIALS) TEST SUMMARY TEST: NFPA 260 Standard Methods of Tests and Classification System for Cigarette Ignition Resistance of Components of Upholstered Furniture, Section 6.1 Cover Fabric Test SCOPE: Recognized national building codes require Class I materials in certain occupancies. Many hotel chains specify this test on a routine basis. PURPOSE OF TEST: To measure the propensity of cover fabric to resist cigarette ignition when tested in combination with a standard foam cushioning material. BRIEF DESCRIPTION OF TEST: Test specimens are prepared as follows: Top Layer: Candidate cover fabric. Bottom Layer: Standard polyurethane foam. The test specimens are placed on a small test rig, simulating a chair back and seat. A lighted cigarette is placed in the crevice where the back and the seat of the chair meet. To intensify the heat, the cigarette is covered by a piece of cotton sheeting fabric. The test records: 1. The extent of char (burn) length on the back section of the seat assembly. 2. Whether or not ignition has occurred. CLASS I VALUES: (1) Maximum char (burn) length of 45 mm AND (2) Non ignition Page 5a

NFPA 260 (COVER MATERIALS) TEST SKETCH TEST: NFPA 260 Standard Methods of Tests and Classification System for Cigarette Ignition Resistance of Components of Upholstered Furniture, Section 6.1 Cover Fabric Test Page 5b

NFPA 260 (FILLING/PADDING COMPONENTS) TEST SUMMARY TEST: NFPA 260 Standard Methods of Tests and Classification System for Cigarette Ignition Resistance of Components of Upholstered Furniture, Section 6.1 Filling/Padding Component Test SCOPE: Recognized national building codes require Class I materials in certain occupancies. Many hotel chains specify this test on a routine basis. PURPOSE OF TEST: To measure the propensity of a filling material to resist ignition by a lighted cigarette when tested in combination with a standard upholstery cover fabric. BRIEF DESCRIPTION OF TEST: Test specimens are prepared as follows: Top Layer: Standard cotton ticking material. Bottom Layer: Candidate filling material. Test specimens are placed on a small test rig, simulating a chair back and seat. A lighted cigarette is placed in the crevice where the back and the seat of the chair meet. To intensify the heat, the cigarette is covered by a piece of cotton sheeting fabric. The test records: 1. The extent of char (burn) length on the back section of the seat assembly. 2. Whether or not ignition has occurred. CLASS I VALUES: (1) Maximum char (burn) length of 38 mm AND (2) Non ignition Page 6a

NFPA 260 (FILLING/PADDING COMPONENTS) TEST SKETCH TEST: NFPA 260 Standard Methods of Tests and Classification System for Cigarette Ignition Resistance of Components of Upholstered Furniture, Section 6.1 Filling/Padding Component Test Page 6b

NFPA 261 TEST SUMMARY TEST: NFPA 261 Standard Method of Test for Determining Resistance of Mock-up Upholstered Furniture Material Assemblies to Ignition by Smoldering Cigarettes SCOPE: Recognized national building codes require that upholstered furniture meet the cited Acceptance Criteria in certain occupancies. Many hotel chains specify this test on a routine basis. PURPOSE OF TEST: To measure the propensity of a completed item of upholstered furniture to resist ignition by a lighted cigarette left unattended on the surface of the piece of furniture. The test procedure provides for testing a mock-up constructed with the actual components to be used in the seating furniture. In Govmark s opinion, a test of an actual piece of upholstered furniture would also satisfy the intent of the standard. BRIEF DESCRIPTION OF TEST: An upholstered furniture mock-up is constructed using the actual fabrics and filling materials. Lighted cigarettes are placed on different areas of the furniture surface, crevices formed by seat cushion and vertical panels, the welt edge of cushions, arm rests, tops of back, etc. To intensity the heat, the cigarettes are covered by a piece of cotton sheeting fabric. The test records the extent of burning (char length) beyond any point of the cigarettes. BUILDING CODE ACCEPTANCE CRITERIA: Maximum Char (Burn Length) 38 mm for each cigarette location Page 7a

NFPA 261 (ACTUAL) TEST SKETCH TEST: NFPA 261 Standard Method of Test for Determining Resistance of Mock-up Upholstered Furniture Material Assemblies to Ignition by Smoldering Cigarettes Page 7b

NFPA 261 (MOCKUP) TEST SKETCH TEST: NFPA 261 Standard Method of Test for Determining Resistance of Mock-up Upholstered Furniture Material Assemblies to Ignition by Smoldering Cigarettes Page 7c

ASTM E1537 TEST SUMMARY TEST: ASTM E1537 Standard Test Method for Fire Testing of Upholstered Furniture SCOPE: Cited by the National Building Code writing organizations, such as NFPA (National Fire Protection Agency) or ICC (International Code Council), for certain occupancies, primarily: (1) Healthcare (2) Correctional detention PURPOSE OF TEST: To measure the fire performance characteristics of seating furniture when subjected to a large, open flame, which could result from an ongoing fire or an attempted arson type ignition. BRIEF DESCRIPTION OF TEST: An actual piece of furniture (or prototype cushions made with component materials) may be tested. The test item is placed inside a room 10 ft. x 12 ft. x 8 ft. high (3 m x 3.65 m x 2.4 m). A four-sided pipe burner with multiple holes is placed in position so that it sits 1 (25 mm) above the chair seat, and is spaced 2 (50 mm) from the chair back. Gas is allowed to flow through the burner to produce a test flame that looks similar to that of a very large barbecue burner flame. The flame is applied for a period of 80 seconds. Various test measurements are taken until all burning of the test item ceases. REPORTING CRITERIA: There are four mandatory reporting categories; however, only the heat release and total heat release maximums are specified by the building codes. The other two reporting categories, 4 ft. smoke opacity and carbon monoxide, do not have specified maximums. BUILDING CODE ACCEPTANCE CRITERIA: Heat Release Rate Total Heat Release 80 kw maximum 25 MJ maximum within the first 10 minutes Page 8a

ASTM E1537 TEST SKETCH TEST: ASTM E1537 Standard Test Method for Fire Testing of Upholstered Furniture Page 8b