New ways of balancing two-pipe systems

Similar documents
1year. The natural connection between energy savings and a balanced two-pipe system.

20% Drive energy efficiency and increase customer satisfaction. asv.danfoss.com. ASV automatic balancing valves

The simple solution to a daily challenge

The simple solution to a daily challenge

1 valve needed instead of 3 for pressure, flow and zone control of water-based heating systems.

61% Smart heating optimization increases your building s lifetime value. asv.danfoss.com. ASV automatic balancing valves

Fits into compatible switch frames from manufacturers such as Busch-Jaeger, Gira, Berker and Merten.

Hydraulic balance in a district cooling system

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Increase the attractiveness of your multi-family building

Technical paper Selection of district heating house stations

Technical paper Hydraulic balance in a district cooling system

Automatic balancing valves ASV-PV (new generation) DN 32-50

MAGNA3 MAGNA3. The full Grundfos product range covers all building application areas:

Balancing & Control. Frese SIGMA Compact. Dynamic Balancing Valve

Heating Control Danfoss Link & Connect Thermostats

3 years payback time. Millions of reasons to choose the best.

MAGNA3 More than A pump

Balancing & Control. Frese PV Compact. Differential Pressure Control Valve

FHM-Cx Mixing Shunts for Floor Heating

Acvatix PICV hydronics made easy. The simple and flexible way to energy-efficient HVAC plants with pressure-independent combi valves

Distribution systems in apartment buildings

The solutions are here The choice is yours...

Danfoss prefabricated floorheatingunit Type FH-G/FH-GS/FH-GR/FH-GRS

FHM-Cx Mixing Shunts for Floor Heating

EFFICIENCY RELIABILITY

Multilux 4-Eclipse-Set

Dedicated Closed Circuit Hydrostatic Fan Drive Control

MORE DEMAND. than a pump. grundfos MAGNA3

MORE DEMAND THAN A PUMP GRUNDFOS MAGNA3

Installation Guide. BasicPlus 2 WT-DR & WT-PR Room Thermostats

TOTAL SYSTEM EFFICIENCY: CONTROL STRATEGIES & SYSTEM DISTRIBUTION. David Grassl PE Mechanical Engineer Principal

The electrical wattage needed by the circulator is:

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

Domestic Hot Water Application manual

Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark

Economics of Balancing. TA Hydronic College

BRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application

Balancing & Control. Frese OPTIMIZER 6-way. Pressure Independent Control Group

Contact person Date Reference Page Daniel Månsson P07886B-rev2 1 (14) Energy and bioeconomy

RA2000 Commercial TRVs

HVAC Water chiller selection and optimisation of operation

IMI Heimeier Kit Hydroca ble

Grundfos is pleased to announce the sales release of many exciting new products.

6 PIPING ARRANGEMENTS

Best Practices for Condensing Boilers

30% Safe. Take lead on your project with an efficient system concept. Technical handbook Danfoss EvoFlat systems from A-Z. evoflat.danfoss.

More than twenty years Hungarian experience in one pipe heating system renovation

Geothermal Flow Centers. Simply Smart. boschheatingandcooling.com

Thermostatic valves with radiator connection systems

Technical description. Atec.

Contact person Date Reference Page Daniel Månsson P07886E-rev2 1 (14) Energy and bioeconomy

Contact person Date Reference Page Björn Folkeson P (14) Energy and bioeconomy

A Review of Hydronic Balancing of Cooling Water Circuit

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

"Best Practices in Modern Hydronic Heating - THE DETAILS

PRESSURE INDEPENDENT CONTROL VALVE TECHNOLOGY. 3/16/2012 Fred Ferrara 1

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails

Meet Max. Unique AFC technology

Danfoss Solar Solutions Application Handbook

Contact person Date Reference Page Daniel Månsson P07886C-rev2 1 (14) Energy and bioeconomy

THERMAL ICE STORAGE: Application & Design Guide

Contact person Date Reference Page Björn Folkeson P (15) Energy and bioeconomy

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

Convertible radiator valve for one-pipe systems, centre distance 35 mm

Dynamic thermostatic radiator valves DYNAMICAL

Information for installers. Simple to install, simply ready for the future. Wilo-Yonos PICO, Wilo-Stratos PICO, Wilo-Stratos, Wilo-Yonos MAXO.

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

7002K. art.7002k/2. art.7002k/1 DESCRIPTION. Complete mixing kit with circulation pump (ErP Ready 641/2009/EC - 622/2012/EC), thermostatic valve with

30% Take lead on your project with an efficient system concept. lower energy.

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

GRUNDFOS DATA BOOKLET MAGNA3. Circulator pumps 60 Hz

Effects of Ultra-High Turndown in Hydronic Boilers By Sean Lobdell and Brian Huibregtse January 2014

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application:

Thermostatic head B. Thermostatic heads Secured model designed for public buildings

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Fundamentals of Hydronic Design

MAKING MODERN LIVING POSSIBLE. User Guide. ECtemp 550. Electronic Intelligent Thermostat.

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

DHP-H Varius Pro+/DHP-L Varius Pro+

A Treatise on Liquid Subcooling

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Minimization of Mass Flow in District Heating Network Equipped with One Stage Domestic Hot Water Production Substations

function Adjustable thee-way thermostatic mixing valve... connections 1/2", 3/4", 1" NPT male union and sweat union

3 years payback time. Millions of reasons to choose the best. Energy Demands? Comfort Problems? Maintenance Concerns?

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

- Data Brochure Universal Reset Module 423

SAUTER Valveco compact. A pressure-independent multi-function valve

Emerging Technologies: VFDs for Condensers. Douglas T. Reindl Director, IRC University of Wisconsin-Madison. University of Wisconsin-Madison

5% energy savings for every degree you lower your room temperature using floor heating.

The New Caroma TMV20

District Heating Fact Finding Mission to DK for Energy Cities members September Experience with Low temperature DH in DK

INSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

Technical paper Distribution systems in apartment buildings

Transcription:

Technical Article - hydronic balancing New ways of balancing two-pipe systems How to achieve superior hydronic balance in heating systems by utilising the Danfoss Dynamic Valve type RA-DV and the Grundfos MAGNA3 speed controlled pump dynamic.danfoss.com

Introduction Low energy consumption in buildings is not something which comes easy. Ensuring that the components in a heating system work together is a pre-requisite when we want low heating bills. A means of ensuring low energy consumption is to balance the heating system correctly, and this article will explain how the new Danfoss Dynamic Valve type RA-DV and the new Grundfos MAGNA3 speed controlled pump work together superbly to achieve this. We will first look at how we compensate for the variations in partial, and how the requirement to balance the heating system means we need to control flow; and to obtain this, we need to control the differential pressure across valves as well. We will show how this can be done by utilising the Danfoss Dynamic Valve type RA-DV in combination with the Grundfos MAGNA3 variable speed controlled pump, looking at an installation in Fredericia, Denmark, where 60 apartments in a 10 storey building has heating supplied from a system consisting of two Grundfos MAGNA3 pumps serving two mixing loops, each supplying 10 raisers, each of which has manual balancing valves of Danfoss type MSV mounted. This installation showed that utilising the speed controlled Grundfos MAGNA3 pump and Danfoss Dynamic Valve type RA-DV in combination ensures problem free operation of a heating system. The difference today is that designated flow can now easily be set on each radiator and pump set point by means of the new Danfoss dp tool (for measuring differential pressure) in combination with Grundfos GO (offering mobile access to Grundfos online tools). Not only does this ensure pump optimisation and lowest energy use, it also reduces time for commissioning substantially. Heating systems need to be commissioned properly to ensure high comfort and lowest possible cost of operation. In earlier days commissioning was a complicated matter where lots of different valves and measuring tools needed to be utilised for proper commissioning. 2

The challenge: balancing two-pipe systems The uneven distribution of heat between units single radiators or apartments in a heating system is what we refer to as a balancing problem. A heating system is balanced when an even distribution of hot water is ensured thereby ensuring maximum comfort at minimum running cost. LOAD Or to put it in another way, a heating system is in balance when the flow in the whole system corresponds to the flow rates that were specified for the design of the system. This is a key challenge for many two-pipe systems. Let us first look at the general challenge in operating two-pipe heating systems. The load profile below shows how load is changing during a heating season in Europe. In only 420 hours out of 7000 heating hours do we need 100% capacity from our heating system. 100% 75% 50% 25% 428 1050 2450 3080 6% 15% 35% 44% HOURS In order to compensate for the variations in load, we equip our systems with thermostatic valves on each radiator. The thermostat will reduce the flow through the individual radiator and ensure the required room temperature is maintained. As pressure loss increases by the square of flow, the differential pressure across the first radiator valves is substantially higher than it is at the last consumer, as shown in the illustration below. RAD RAD RAD 1 2 3 p a. p b. p c. H a. b. c. Q 3

As different radiators need different flows in order to heat up the room in question, it is possible to pre-set the maximum flow on each radiator valve. The pre-setting can be seen in the graph below for a typical radiator valve. The pre-setting can be adjusted from 1-7 and finally in N position which indicates a fully-open valve. When a heating system is equipped with a constant speed pump, the delivered differential pressure will vary greatly, as shown in the illustration below. When flow is reduced the delta P across the individual valve will increase. In the above example the needed flow at max load is 37 l/h. But when the differential pressure increases (+0.2 bar), the flow will increase, as shown to 62 l/h = 67 %. 2 Delta P increase from 0,1 bar to 0,3 bar 1 100% load 420 hours 100% FLOW As flow decreases, the differential pressure increases in a fixed speed pump. The conclusion is that, in order to meet the designated flow, we need to control the differential pressure across valves as well. We will now see how this was done. 4

Static vs dynamic commissioning of heating 2-pipe systems A major challenge is that heating systems are often constructed and designed to meet the heating requirements in the worst case scenario, such as when outdoor temperatures are extremely low. But as this occurs only a few times every year (if at all) the system will be oversized in the remaining period. This typically results in overspending on energy. The following example of static commissioning of a heating system with dynamic requirements is from an installation in Fredericia, Denmark, where 60 apartments in a 10 storey building has heating supplied from a system consisting of two Grundfos MAGNA3 variable speed controlled pumps serving two mixing loops, each supplying 10 raisers, with a total 273 RA-N DN 10 radiator valves and and static balancing valves of Danfoss type MSV mounted. The building is from 1972 and was renovated in 1985, including new windows and façade. The two mixing loops each supply 10 raisers at the 10 storey apartment building in Fredericia, Denmark. 5

We will now look at how the system operates, with static balancing valves and static radiator valves, with pre-setting. Later, the same test is performed, but this time with dynamic valves. The test is done not only at full load but more importantly at partial load too. At the same time, differential pressure has been measured at the furthest radiator to make sure that there is enough pressure to reach the designated flow for the radiator furthest away, in this case it is 10 kpa and the designated flow is 30 l/h, so the pre-setting will be 2.5 for the radiator valve. In the test we have set the control mode for the pump to be proportional pressure mode first and secondly constant pressure mode. And then we have added the new Danfoss Dynamic Valve type RA-DV in combination with the new Grundfos MAGNA3 speed controlled pump. The MAGNA3 pump can be set in proportional pressure mode, which will enable the pump to reduce delivered differential pressure, when flow is decreasing. See the chart, below left. PRESSURE 100% 85% 75% 70% 60% COOPERATION PUMP AND VALVES +4,4 PUMP CURVES +3,1 +3,0 20% 40% 50% 70% 100% +4,0 DESIGN DUTY POINT FLOW CONTROL CURVE RADIATOR VALVE SYSTEM CURVE ADITIONAL DELTA P FLOWLIMIT AREA The red line shows the proportional control curve and the green line the minimum required differential pressure in the system. As can be seen from the blue circles, there will always be surplus differential pressure available. Therefore we need the pump and the dynamic radiator valve to work well together. + p [kpa] 60 50 40 30 20 10 0 H [m] 7 6 5 4 3 2 MAX 1 MIN 0 0 2 4 6 8 10 12 14 16 18 20 22 Q [m³/h] H [m] 7 6 5 4 3 2 MAX 1 MIN 0 0 2 4 6 8 10 12 14 16 18 20 22 Q [m³/h] Even though the MAGNA3 pump reduces its delivered differential pressure, there will at partial load still be a delta P surplus across the radiator valves*, shown in the table below. The key issue here is that although a speed controlled pump helps, it cannot keep differential pressure stable; this is an issue solved by pressure-independent dynamic valves. Static radiator valve Control mode, pump System load 100 % System load 50 % Increased ΔP (by 50 % load) Increased flow Proportional 10.2 kpa 18.0 kpa 7.8 kpa 33 % increase Constant 10.2 kpa 27.3 kpa 17.1 kpa 46 % increase Meassured values at the radiator furthest away Dynamic radiator valve Control mode, pump System load 100 % System load 50 % Increased ΔP (by 50 % load) *Assuming that the heating system is a traditional widespread system. If this is not the case and instead the system is equally divided in two parallel systems, the optimum control mode will be constant pressure. Increased flow Proportional 9.8 kpa 10.5 kpa 0.7 kpa < 1 % increase Constant 9.9 kpa 10.6 kpa 0.7 kpa < 1 % increase Meassured values at the radiator furthest away 6

So what that this tell us is that, with static radiator valves at partial load of 50 %, the radiators will have (17.1-7.8) = 9.3 kpa increased pressure. What this means in risk of overflow can be seen in the figure below. Radiator valves, Static vs Dynamic. Flow [l/h] 200 190 180 170 160 150 140 130 120 110 100 90 80 0 10 20 30 40 50 60 dp [kpa] Dynamic Valve Static Valve Using the Danfoss dp tool to balance a radiator. When differential pressure increases from 7.8 kpa to 17.1 kpa, the flow will increase from 80 to 132 l/h, whereas the dynamic valve will keep the flow constant. The increased delta P at part load would create overflow and increase the heating bill, showing the need to control the delta P correctly. Using the Danfoss Dynamic Valve type RA-DV keeps the flow constant, even when delta P is changing. A differential pressure controller inside RA-DV keeps the pressure drop over the control valve on the constant level which means that a constant flow through the RA-DV valve is maintained. This is shown in the graph below. max flow RA-DV Flow [l/h] 160 140 120 100 80 60 40 20 0 0 10 20 30 40 50 60 dp [kpa] So the answer to the challenge about additional delta P, is to utilise a speed controlled pump like the Grundfos MAGNA3 and use Danfoss Dynamic Valve type RA-DV, which in combination ensures problem free operation of a heating system, and this has been shown from the example from Fredericia discussed above. The installation has been running now for one year, and we can see that the cost for pump operation has been reduced by approximately 57 % or equal to 980 kwh/year. 7

Pump optimisation If the pump runs optimally, the lowest possible energy use is ensured. Pump optimisation together with proportional pressure control is possible only with automatic balancing valves. Commissioning is made easy using the new Danfoss dp tool (for measuring differential pressure) in combination with Grundfos GO (offering mobile access to Grundfos online tools), and ensures pump optimisation and lowest energy use. The Danfoss dp tool is an extremely useful, simple and unique tool used during commissioning that measures the available differential pressure. It is mounted on the critical valve where the differential pressure is lowest. In full load mode, the delta P needs to be 10 kpa. If the differentail pressure turns out to be either lower or higher than this, the set point, is adjusted on the MAGNA3 pump. The setpoint is related to the differential pressure delivered by the pump. Note that this value will always be higher than what messured across tha critical valve, as differentaial pressure decreases throughout the system. Grundfos GO is the mobile tool box for professional users on the go. It is the most comprehensive platform for mobile pump control and pump selection including sizing, replacement and documentation and can be downloaded to any ios or Android device. Having completed these steps you have ensured that the energy system is correctly commissioned, not only at design flow conditions, but also and most importantly at partial load conditions. Result will be lowest possible energy consumption for the entire heating system. Conclusion Superior heating systems need thorough commissioning, when lowest possible energy bills is the goal. By using the new and innovative Danfoss Dynamic Valve type RA-DV in combination with the new Grundfos MAGNA3 variable speed controlled pump, this is now highly achievable. In the specific case in Fredericia, Denmark, the achieved savings adds up to not less than 12 % of the heating bill. This is only possible utilising both the new Danfoss dynamic valve in combination with the new Grundfos MAGNA3 pump. The difference today is that designated flow can now easily be set on each radiator and pump set point can be set by using both the Danfoss dp tool and Grundfos GO. Not only does this secure optimal function, it also reduces time for commissioning substantially. This shows that there are plenty of reasons for you as a consulting engineer to chase down the potential energy savings that are out there in many housing associations. Heating systems need proper commissioning to ensure high comfort and the lowest possible cost of operation. In earlier days commissioning was a complicated matter where lots of different valves and measuring tools were needed for proper commissioning. Rene Hansen, Danfoss June 2015 Anders Nielsen, Grundfos Grundfos GO, for Android and ios. Danfoss A/S Heating Segment Ulvehavevej 61 7100 Vejle Denmark Tel.: +45 7488 8500 Email: heating@danfoss.com www.heating.danfoss.com VFGWK102 Copyright Danfoss... 2015.10