Smoke Detection Solutions for Challenging Environments

Similar documents
Open-area Smoke Imaging Detection (OSID)

Open-area Smoke Imaging Detection (OSID)

Open-area Smoke Imaging Detection (OSID)

Open-area Smoke Imaging Detection (OSID)

OSID in Challenging Environments

Open-area Smoke Imaging Detector. Engineering Specification

Intelligent Earliest Warning Aspirating Fire Detector

HART XL High Sensitivity Smoke Detection

COMPANY PROFILE Technoswitch with its headquarters, manufacturing and training facilities in Johannesburg, has been supplying and providing technical

FAAST. Fire Alarm Aspirating Sensing Technology

Aspirated Smoke Detectors

HART XL High Sensitivity Smoke Detection

The World's No. 1 Brand of Aspirating Smoke Detector

Buys Time. Aspirating Smoke Detection

Aspirating Smoke Detection (ASD) Systems Fire Detection

FAAST. Fire Alarm Aspirating Sensing Technology

Fire Detection System: An Overview

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

SIL 2. Ultima X Series Gas Monitors CERTIFIED

The World s No. 1 Brand of Aspirating Smoke Detection

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

LEARNING SPECIAL HAZARD DETECTION TYPES

TrueAlarm Analog Sensing

The World's No. 1 Brand of Air-sampling Smoke Detector

LaserFOCUS VLF-250 Engineering Specification

The Next Generation of VESDA Aspirating Smoke Detection Technology

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

The World's No. 1 Brand of Aspirating Smoke Detector

-Industrial. W hen All Else Fails... Difficult Applications. The Only TRULY Industrial Air Sampling Detector For Hostile and Difficult Environments

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Flexible Air-sampling Smoke Detection

Evolution Analogue Addressable Fire System

Gas Detection division of Arjay Engineering. Gas Detection Maintenance Facilities Parking Garages Warehouses. EN-GD-11a

THE SOONER YOU KNOW, THE SAFER YOU ARE.

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

Thank You for Attending Our February Webinar:

Buys Time. Aspirating Smoke Detection

A P P L I C A T I O N S G U I D E. Single-Ended Reflected Beam Smoke Detector

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

I am Rick Jeffress and I handle sales for Fike Video Image Detection. We thank the AFAA for coordinating the venue for this presentation, and we

and Aspirating Smoke Detection

Installation and Operation Manual

Fact File 66. Guide to Beam Smoke Detectors

EARLIEST SMOKE DETECTION WITH MAXIMUM FLEXIBILITY

ALTAIR 5X Multigas Detector Product Specification

Engineering Specification Guide VESDA-E VEP

Why Hart XL Aspirating Smoke Detection?

The Next Generation of VESDA Aspirating Smoke Detection Technology

Products and performance

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

IFD-E Flame Detector User Manual

Aspiration Detection.

Dräger Flame 2100 Flame Detection

Range brochure. Beam detection. others look up to.

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

TX7100. Intelligent Addressable Optical Smoke Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Guidance on Video Smoke Detection Technology (VSD)

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Safe Operation Manual. Honeywell IQ Force Gas Detector

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Flame Detection Jon Sarfas

NJSP HMRU. Module 5 B HM Operations 1

Your trusted partner in providing the best fixed Gas Detection Sales and Service in Western Canada

Aspiration Systems for Smoke Detection

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Senscient s team has more than 150 years collective experience in gas. detection.

Dräger PIR 7200 Toxic Gas Detection Transmitter

I N T E L L I G E N T A S P I R A T I N G. Intelligent Aspirating Fire Detector. Intelligent Earliest Warning Aspirating Fire Detector

ASHRAE Safety Standards. Mechanical Rooms and Gas Detection in Commercial Applications

Dependable Solutions for Gas Detection

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

Multi-Point Peripherals

G-TECTA TM. Portable Gas Detection Instruments

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

IFD-E Flame Detector User Manual

Gas Detection in Process Industry The Practical Approach

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

FIRE IR SENSOR Flame Detection

Industrial fire alarm systems

VESDA VLP. Engineering Specification

Frequently Asked Questions

FAAST PRODUCT RANGE Aspirating Smoke Detection

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

this is by far the best beam money can buy

IMR IX176 Portable Gas Detector User Manual

IGD.CO.UK

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

FAAST Beyond Standard Methods of Detection

SMOKE CONTROL - NEW DIRECTIONS

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

incontrol Systems Inc. Flame and Gas Detection

FAAST. Fire Alarm Aspiration Sensing Technology

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

Application Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES

MSA Gas Detection. for the Water and Wastewater Industries. Does your facility meet NFPA 820?

Transcription:

Smoke Detection Solutions for Challenging Environments

Agenda The Detection Triangle A Balancing Act Harsh and/or Industrial Environments New advances in Open Area smoke detection Traditional Beam Detection Challenge Technology Breakthrough OSID Field-proven applications Industrial Very Early Warning Smoke Detection ASD Overview ASD in Industrial Environments The VLI (Industrial) Field-proven applications Beyond Smoke Air Sampling Gas Detection Leverage Vesda to provide gas detection Overcomes spot gas detector challenges Q & A 2

Optimum Protection Requires a Balance Fire Triangle Detection Triangle Challenging environments complicate achieving optimum protection 3

The Detection Triangle Provides the highest level of detection to ensure protection of Life Property Business continuity Environment Without false alarms that Create disruptive false or nuisance alarms De-sensitize personnel and occupants to alarms Ultimately leading to disregarding alarms or disabling safety systems Place an extra burden on local first responders At an affordable cost Initial installation cost Long term operating, servicing, and testing costs 4

Challenging Environments A Challenging Environment is a space where: Detection is difficult due to: Environmental conditions that cause false and nuisance alarms Environmental conditions that shorten detector life High and variable airflows High ceilings Detector sensitivity and longevity are compromised in harsh environments due to: Dirt and dust Temperature extremes High EMI Moisture, fog, steam, water condensation Birds and insects Building movement Sunlight Detector location Toxic and corrosive gases 5

Challenging Environments A Challenging Environment is a space where: Maintenance is difficult Extreme environmental conditions Inaccessible areas High ceilings Roof or floor spaces Within elevator shafts Equipment racks Restricted access High security areas Production areas 24/7/365 operation Unobtrusive detection is required To prevent vandalism or tampering Not disruptive to architectural designs Preservation of historic buildings and artifacts Evacuation may be challenging High concentration of large number of people Exit paths are restricted Occupants require assistance 6

New Advancements in Open-area Detection Open-area Smoke Imaging Detection Technical obstacles overcome Applications Very Early Warning Smoke Detection ASD Overview Deploying ASD in industrial environments Field-proven applications ASD requirements matrix 7

Awards and Recognition 2012 Poznan International Fair Gold Medal ASIS 2011 Accolades New Product Innovation Award in Fire & Life Safety - North America, 2011 a 2011 Fire Excellence Awards - Best Detection and Alarm Product Award 2011 New Product Showcase (NPS) -Judge s Choice Award at the ISC West. 2010 Hot Technology by Network Products Guide

Challenges with Beam Detectors False alarms due to Dirt Dust Steam Insects Banners Fork lift trucks Ladders Banners Building movement Building vibration Sunlight Reflected sunlight 9

What Makes Dual-wavelength Different The improvements over traditional beam detectors stem from four core design ideas: Dual-wavelength light frequencies Digital imaging vs. photodiodes A unique method for aligning Smarter algorithms 10

Overcoming Conventional Challenges Large particle obscuration rejection Use of UV & IR in specific wavelengths assist in evaluating whether obscuration is caused by small particles in the physical size resembling smoke or from larger particle (i.e. dust, steam, insects, fork-lift, ladders, etc.) Tolerance to building shift and vibration The multiple pixels of a CMOS imaging chip as opposed to a photodiode along with the uniquely coded light beam from an emitter provides the ability to track the position and tolerate movement Foreign light intrusion The Imager is fitted with a dyed glass filter, designed to be almost opaque except to all but two wavelengths of interest 11

Dual-wavelength vs. Single IR Beam Active emitter LEDs transmit wide beam IR and UV to the Imager IR and UV have differing wavelengths Respond differently to smoke Emitter IR beam Smoke Imager Relative strengths of the UV & IR are compared Detect smoke UV beam Dust Discriminate against particulates that cause nuisance alarms on traditional beams Software locates illuminated pixels on the CMOS imager Obstruction Each emitter is uniquely coded Imager software tracks building movement No controlled motor drives 12

Powerful Benefits Imager versus photodiode One imager equals 100,000 s of photodiodes Actual view from a 45 degree imager with 4 emitters in a 13,500 sq ft area An Imager locates and tracks the position of an emitter anywhere in its field of view at pixel level Can operate reliably in all lighting conditions; bright day / sunlight to total darkness Emitters 13

Installation & Commissioning Simple and easy installation using a unique Laser Alignment Tool Requires only rough alignment due to the wide angle of view of the imager(s) Up to 70% time saving compared to traditional beams Beam length up to 492 ft Outperforming traditional beams by up to 50% 14

Reliability Benefits Excellent false alarm immunity to dust, steam, insects, objects and structural movement Eliminates false alarms by automatically compensating for building movement No moving motor parts eliminates hardware failures Operates in all ambient lighting conditions Not affected by nearby reflecting surfaces No false alignment due to reflecting on fog Ability to compensate for high air movement

Financial Benefits Low implementation costs because of simple and fast installation and alignment - Only the Imager unit has to be wired (battery powered Emitters) - Power can be supplied from panel - Fast and simple coarse manual alignment Lower maintenance cost for larger areas - Test filter at the Imager or Emitter - No intervention costs for misalignment

Real Field Challenges Overcome by Open-area Smoke Imaging Detection

OSID Applications Atriums Stadiums Historic / Cultural Buildings Tunnels Logistics Generator Turbine Halls Stadiums Event Centers Concert Halls Airports Train Stations Long Corridors Industrial infrastructure Large Open Spaces

Long Distances Reliably detecting at 497 ft Allows for 20% setting at 430 ft Aligned through metal support structure of the roof 19

Industrial Site 6 /15 cm End-user was considering linear heat cable for controlled burn down 20

Semi-open Warehouse Example of the effect of condensation on the emitter No differentiation between IR and UV and hence no alarm nor faults 21

Chicken Farm Spikes with up to 20% when chickens run around. Estimated time between cleaning of lenses 2-3 month 5,85 /15 cm 22

Recycling Plant Estimated time between cleaning of lenses 1 month 5,85 /15 cm 23

Direct Sunshine Disregarding the avoid East West direction recommendations, Dual Wavelength only generates a saturation fault when exposed directly to the sun. 5,85 /15 cm 24

Industrial Very Early Warning Smoke Detection

New Advances in VESDA Open-area Smoke Imaging Detection and Applications Technology overview Field-proven applications Very Early Warning Smoke Detection ASD Overview Deploying ASD in industrial environments Field-proven applications 26

What is Very Early Warning Smoke Detection? A detection system that actively draws multiple air samples from a fire zone, via a pipe network, to a centralized detector

Equivalency NPFA 72 CAN/ULC-S529-02 BS5839-1 AS1670 = Each sampling port of an Aspirating Smoke type smoke detector shall be treated as a spot

Cumulative Smoke Detection ASD exploits the cumulative effect all smoke entering a sampling hole contributes to the detector s smoke reading Smoke diffuses through out a space... the more diffuse the more holes it enters... An alarm can be triggered by A localized high concentration of smoke A widespread low concentration of smoke

Simplified Test & Maintenance ASD enables remote sampling and test Verify air flow and smoke transport time enables testing at last hole Only smoke in last hole Easy access test point

Why Very Early Warning? 1. When business continuity is paramount 2. When smoke is difficult to detect 3. When maintenance access is difficult 4. When unobtrusive detection is required 5. When evacuation is a challenge 6. When environmental conditions are difficult 7. When suppression systems are present 8. When smoke and gas detection is required

Very Early Warning Smoke Detection in Industrial Environments

Perceptions of ASD Designed for the cleaner environments Industrial applications beyond ASD capabilities Market skepticism still exist ASD Comfort Zone (Roots in Data Center and Telecommunications) Uncomfortable Zone (Industrial) Clean Dirty Historically ASD system designs in all industrial environments required system application engineering 33

Industrial Applications Require More from ASD Improved general protection Hardened product enclosure IP/NEMA rated Eliminate need for secondary enclosures Longer pipe run to accommodate larger facilities Greater visibility of status LED Improved filtration External filtration can stress system maintenance Eliminate need for external filters Field serviceable modules Less down time Lower spare part inventory Lower long term operating costs Establish standard to quantify contamination resistance 34

Fit for purpose Industrial ASD IP54 Enclosure Intelligent filtration 4 x 300ft. pipe runs High intensity status LED Field serviceable modular construction 35

Intelligent Filtration Reduce contaminates entering detection chamber Innovative flow partitioning and HEPA filtration Continuous monitoring of filter and airflow Optimum detector sensitivity over detector life. Flow Sensors Larger x% of flow passes through HEPA filter Air coming directly from sampling pipe (total airflow) Pipe Flow Splits into x% and y% Smaller y% of flow passes unfiltered Flows recombined to enter detector at lower obscuration than original

Modularity Delivers Lower Total Cost of Ownership Detection chamber Aspirator Electronics Filters Fewer spare parts less down time 37

New Approach to ASD in Industrial Environments In-line Filters No In-line Filters Detectors inside protective enclosures No protective enclosures required Enhanced filtration & IP-rated enclosure can reduce Total Cost of Ownership by 40 to 60% 38

Other Features Up to 2,000m2 (20,000 sq. ft.) coverage 4 inlet pipes Total pipe length up to 360m (1,200 ft) Five (5) high-intensity status LEDs for greater visibility Referencing AutoLearn Smoke and Flow Air-path monitoring Five (5) relays (Fire, Fault and 3 configurable) Direct connection via USB Native TCP/IP Xtralis VSC, VSM and ASPIRE2 software support Easy mounting via steel support bracket Easy cable termination access Metric and imperial pipe entry ports Standard GPI feature IP 54 Enclosure (30 psi)

Illovo Sugar Mill Pipe Network Design & Installation ASD Detector in Protective Enclosure Industrial ASD Detector 40

Cook Colliery Underground Mine 41

Cook Colliery Pipe Network Design 42

Cook Colliery Installation 43

Wood Pellet Storage Industry Solutions

MCC Electrical EQUIPMENT Rooms

BATTES Battery Rooms

Cable Tunnels Industry Solutions

VLI Applications Mining Manufacturing Processing Plants Conveyor protection Petrochemical Plants Tunnels Power Generation Pulp & Paper Production Warehouses Water Treatment Transport Timber Production Fertilizer Plants Abattoirs Laundries Cold Storage Textile Lift shafts Stables, and more.

Beyond Smoke What about when the hazard is more than just fire? Solution: ASD-based Gas Detection Environmental Monitoring +

Multi-hole Aspirated Gas and Smoke Detection VESDA ECO Air actively drawn through pipe network with multiple sampling holes to the Aspirated 24/7 Active Sampling & Detection Gas Detector then to the Aspirating Smoke Detector Sampling Pipe Network Aspirated Gas Detector Protects Plant / equipment Personnel safety Detects Toxic gases Flammable gases Oxygen deficiency Fire (Smoke) Aspirating Smoke Detector Potential for better performance Remove guess work from detector placement Greater area coverage Potential for lower total cost of ownership Lower initial install Lower long term operation Xtralis Pty. Ltd. Confidential Information 50

Inherent Advantages of VESDA ECO Active 24/7 monitored sampling versus diffusion Ability to condition air stream Enables use in harsh environments Temperature extremes Wet High EMI Dirty Hard to access areas Extends detector life Minimize / eliminate need to run cable and conduit Mount detectors away from detection spaces Simplified installation Ease of access for testing and servicing Eliminate process / personnel disruption during servicing Take the guess work out of detector placement Lower total cost of ownership Take the guess work out of detector placement Non-intrusive sampling to satisfy architectural or security concerns Xtralis Pty. Ltd. Confidential Information

Gases Detected Combustible Toxic Other Methane Hydrogen Propane Pentane Gasoline Alcohol Ammonia Carbon monoxide Ammonia Hydrogen sulfide Nitrogen dioxide Sulfur dioxide Chlorine Oxygen deficiency Oxygen enrichment Carbon dioxide Xtralis Pty. Ltd. Confidential Information 52

VESDA ECO Product Overview Plug and play factory calibrated replaceable sensor cartridges Single or dual sensor cartridges Two adjustable alarm thresholds per sensor On board relays, 4-20mA, and RS485 Modbus Event logging (50,000 events) Calibration port Class 1 Division 2 models available Can be installed in new or existing ASD systems Class 1 Division 2 Xtralis Pty. Ltd. Confidential Information 53 53

Value Proposition: Eliminate guess work in detector placement Increase sampling points provide better area coverage to detect smaller leaks Provides equivalent coverage with fewer detectors Better detection in ventilated spaces Reduced maintenance cost with easier access Xtralis Pty. Ltd. Confidential Information 54 54

Value Proposition: Lower Total Cost of Ownership Conventional Point Detector Solution ASD / AGD Solution Individual Smoke and gas detectors Detector installation and wiring Lower Initial installation costs Operating and maintenance costs Detector test and maintenance Xtralis Pty. Ltd. Confidential Information 55 55

Applications Expanding Data &Telecom Centers Battery rooms Power and Energy Gas fired equipment Turbines Boilers Coal power generation (CO, Hydrogen) Wood pellet (CO, Oxygen) Hydroelectricity (Oxygen and Hydrogen) Fuel Cells (Hydrogen) Refrigeration / Cold Stores Distribution centers Dairy operations

Latest Applications Metal Processing/Refining Hot strip mills H2S Transportation TUNNELS Loading bays Car parks Power of ECO 1 ECO vs 5 point detectors

Steel Mill Tunnel Protection 300 foot tunnel under electric reheat furnace Furnace utilizes nitrogen protective atmosphere risk of oxygen depletion (asphyxiation) Cable trays risk of fire Solution: Industrial ASD + Oxygen 58

Cold Storage Facilities Risk A fire and toxic gas risk due to excessive build-up of Ammonia and reduced ventilation rates. Ammonia (NH3) is commonly used in the cooling process.. Significant costs to maintain traditional gas detection. Challenges to late stage fire detection. Vertical Markets Logistics Warehousing

UPS and Battery-charging Rooms Risk A fire and explosive gas risk due to excessive build-up of Hydrogen and reduced ventilation rates. Hydrogen (H 2 ) is generated during the charging phase of battery operation. Vertical Markets Telecommunication Centers Data Centers Oil & Gas, Petrochemical Energy Production Transportation Commercial

Process Buildings, Shelters, etc. Risk A fire, explosive, toxic gas risk, due to leaks, a gradual buildup and/or inadequate ventilation. Methane, H2S, SO2, Piped gases. Oxygen depletion is also possible. Vertical Markets Tele/data communication Oil & Gas, Petrochemical Energy Production Transportation Manufacturing Metals Refining

Utility and Service Tunnels Risk A fire, explosive, toxic and Oxygen depletion risk, due to a gradual build-up and inadequate ventilation. Methane & Hydrogen Sulfide ingress from local sewage systems or landfill decomposition, or Natural Gas from local gas main supplies. Piped gases. Vertical Markets Tele/data communication Oil & Gas, Petrochemical Energy Production Transportation Education (Universities)

VESDA ECO Reduces the guess work in gas detector placement Sample an area, not a point in space Better area coverage More tolerant of changing environmental conditions (i.e. air flow) Potentially lowers initial equipment costs ASD plus Gas Easy to install to ASD Little to no cabling Fewer detectors possible Potentially lowers operating & maintenance costs Easy access to ASD and AGD Less test and calibration gas and labor Fewer detectors to maintain and replace Advances the State-of-the Art in Gas Detection Xtralis Pty. Ltd. Confidential Information 63

Q & A 64

Contact Details www.xtralis.com THE LIBRARY REGISTER for access to: White Papers Design Guides CAD Details Application Notes Presentations Success Stories 800-229-4434 for National Support Team Inexperience and design compromises impact ASD smoke detection performance 503-980-8706 for Jonathan Mandoli, Regional Manager Contact jmandoli@xtralis.com