Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

Similar documents
Rotameter series 250 metal tube variable area flowmeter

FS-100 Series OUTLINE MAIN APPLICATIONS FEATURES LEVEL SWITCH

INSTRUCTION MANUAL FLOAT TYPE LEVEL SWITCHES HITROL CO., LTD.

Level gauges Series LS Level indicator, switch and transmitter for liquids

SITRANS T temperature transmitters A broad product family for every application. sitrans

UW Purchase Specification Section Steam Condensate or Hot Water Meter Page 1 of 9

Ar-Mite TM Low Flow Armored Flowmeter

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

Intelligent sensing for every temperature and condition

Azbil introduction 2015

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Electronics based on Smart Meter Manager TM Technology

Rosemount 3051CFC Compact Flowmeter

General Specifications

DOO IK ENG PRODUCT CATALOG DOO IK ENG TEMPERATURE SENSOR PRESSURE SWITCH NON FLOW SWITCH THERMOMETER

FCHM Hydromatic Pump Control Module

Ultrasonic Point Level Switches

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

Pressure-Resistant and Explosion-Proof Electric Contact Pressure Gauges and Pressure Switches

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

Dust Concentration Meter

Bristol Babcock Oil Content Monitor "oil in water"

ProRadiant Controls, Valves and Actuators

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Customized Industrial Products

NORTH AMERICAN ADVANCED TECHNOLOGIES, INC.

Sitron s CF Line of Flow Switch Monitors

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Enraf Servo Gauge 854 ATG

Spandau Pumps. Sealless Immersion Pumps for Industrial Applications. Overwiev of Products

Rosemount 3100 Series Ultrasonic Level Transmitters

ProMinent ProMus Hydraulic Diaphragm Metering Pumps

Circulation Heaters Selection Guidelines

Models 65, F65, 150 & F150

Direct reading flowmeters type RM

The next generation thermometer from the global leader

MODEL APT 3700N. Smart Pressure Transmitter For Nuclear Service. Duon System Co., Ltd. for Differential / Gauge / Absolute Pressure Measurement

Circulation Heaters Selection Guidelines

OEM Sensors for HVAC manufacturers Heat recovery Chiller

LOW PRESSURE Intrinsically Safe Transducer AST44LP

MT3750C Series. Metal Tube Variable Area Flowmeters. Ships in 5 days. Overview. Product Description. Features. Variable Area

Ultrasonic Switches. Features & Benefits

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

SP-2400 & 2410 Series Smart Valve Positioner (Linear & Rotary)

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

WAGO-I/O-SYSTEM 750 Explosion Protection via Intrinsic Safety

The A-series Eletta Flow Monitor with local indication and analog output

M-Switch Float Operated Liquid Level Switch

Temperature measurement with SITRANS T siemens.com/processinstrumentation

Level Measurement Continuous level measurement Ultrasonic transmitters

MT3809G Series. Data Sheet. Metal Tube Variable Area Flowmeters. Overview. Product Description. Variable Area

Flow Level Pressure Temperature. Rugged tactile response keys. Try the all new Fluidwell Configurator at:

A.YITE GROUP (Hongkong & Shanghai)

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

Paddle Flow Switch. Pressure Control Flow Switch

MT3750C Series. Metal Tube Variable Area Flowmeters. Overview. Product Description. Features. Variable Area

Analog Transmitter AT1000 AT1

PRODUCTION BATCH ATTRITORS FOR WET GRINDING. visit

SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof DA-500

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

CRYOGENIC PRODUCTS SEB Series Trim Heater

MagMaster MFE flowmeters feature an innovative multifrequency

P SERIES PURGEMETERS. Full Coverage for Semi-Conductor Processes for Built-IN Use for Equipment for General Industrial Processes

Enraf Servo Gauge 854 XTG

Danfoss gas detection unit Type GD Heavy Duty

Specifications. Table of contents. 2:Specification. 3:Composition. 4:Instruments outside figure

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

for relative humidity and temperature

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

13-1. Temperature Regulator

Temperature Solutions Line Card

1510 Side Mounted Level Switch

Model D12-IR. Digital Gas Transmitter...

ENERGY, OIL & GAS. astsensors.com macrosensors.com. Transducer & Transmitter Capabilities. Your sensor business partner...

MT3809G Series. Metal Tube Variable Area Flowmeters. Overview. Product Description. Variable Area

Electronic Pressure Digest. Pressure and Temperature Transmitters

Variable Area Flowmeters Ratosight TM Flow Rate Indicators with Optional Ratolarm - 10A2235

Ronan Model X96S Series Weighing System

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Upompe Primeflo XP7 chemical self-priming centrifugal pumps

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

Section B Field Instruments

! WARNING. Before using product, read and understand instructions.

For liquid measurement, Water (Sp. Gr. 1.0, Viscosity 1.0cP) For gas measurement, Air at 0 o C, 1atm Q=Q0 X

the next generation thermometer from the global leader

SITRANS F M MAG 3100 P:

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

AUXILIARY EQUIPMENT FOR ALL YOUR NEEDS

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER

Temptek Auxiliary Equipment

Technical Specification VFD

Better Design, Better Control, Better Systems.

DIVISION 15 MECHANICAL

Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch

Transcription:

MAXIFLO TM Overview MaxiFlo TM KM Series Metal Tube Rotameters are rugged, versatile and accurate variable area (VA) flow meter offering 2.0% full scale accuracy. It s based on simple and easy-to-understand flow measuring principle but is versatile in the types of fluid it can measure and site conditions, under which it can be installed. The meter is manufactured to the user s application specifications. So, there s no configuration or calculation required at the time of installation or operation. So, it s simple to install and operate. The flow rate is indicated on a scale with a needle that is coupled to the rotating float using a magnet. Using potentiometer circuitry, the meter can output 4-20mA signal for flow rate, which can in turn be used to display the instant flow rate and the totalized flow on a digital LCD and output pulse signal for the accumulated flow. It can also output alarm contact signal for low and/or high set points for flow controlling processes. Metal Tube Rotameter 100% Customer Satisfaction Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS) Various materials can be used for wetted parts. So, the meter can handle almost all liquids and gases that are highly corrosive. Also, the meter can be used for hazardous areas using Ex-Proof enclosure option. Main Features KMF-A KMF-B KMF-C Simple Measurement Principle This is one of the earliest flow meters that came into use. It adopts easy-to-understand and very intuitive principle of variable-area flow meter principle. (Please refer to Operation Principle overleaf) Simple Design In its primitive basics, the measuring element is composed of just a tapered tube and a float. Low Maintenance Constructed to sustain corrosion, abrasion and shocks, etc., the meter requires minimum maintenance. KMF-J KMF-E KMF-Q Versatile Construction The meter can measure all liquids, gases and steam. Various Flow Directions The meter can be configured for Bottom to Top, Bottom to Top Side, Bottom Side to Top, Bottom Side to Top Side and Bottom Rear to Top Rear. Various Output and Display Options 4-20mA, pulse, alarm contact, flow rate display and total display are available. Explosion Proof Enclosure For signal output models, the user can choose ex-proof enclosure for hazardous environment. KMSS KMS KMF-J/LF Seil Enterprise Co., Ltd. 405 Halla Sigma Valley 345-90 Geumcheon-Gu Seoul Korea Tel: 82-2-6343-6473 (3 Lines) Fax: 6919-1431 Email: sales@maxiflo.co.kr 1

MAXIFLO TM Metal Tube Rotameter Operation Principle Variable-area flow meters, often called rotameters, consist essentially of a tapered tube, a float and scaled indicator as you see in the figure below. Although classified as differential pressure units, they are, in reality, constant differential pressure devices. Flanged-end or screwed-end fittings provide an easy means for installing them in pipes. When there is no flow, the float rests freely at the bottom of the tube. As the fluid enters the bottom of the tube, the float begins to rise. The float material is selected so as to have a density higher than that of the fluid and the position of the float varies directly with the flow rate. Its exact position is at the point where the differential pressure between the upper and the lower surfaces balance the weight of the float. Because the flow rate can be read directly on a scale mounted next to the tube, no secondary flow-reading devices are necessary. However, if desired, automatic sensing devices can be used to sense the float's level and transmit a flow signal. Rotameter tubes are manufactured from glass, metal, or plastic. Tube diameters vary from 1/4 to greater than 6 in. GRAVITY 100 90 EQUILIBRIUM 80 70 60 Float 50 40 FLOW 30 20 10 Tapered Metering Tube 0 Unit: M3/h Scaled Index Applications Hot and cold water as well as air flow measurement in air conditioning Medium and large line measurement in general process industry Cooling water lines Water treatment process Pure and ultra-pure water production facilities Testing of fire fighting pumps Testing of blowers Etc. 2

MAXIFLO TM Metal Tube Rotameter Model Overview Model Code Description Remarks KM KMS KMSS Metal Tube Variable Area Flow Meter (Rotameter) Small-Size Metal Tube Variable Area Flow Meter (Rotameter) Micro-Flow Metal Tube Variable Area Flow Meter (Rotameter) 25A and below sizes 25A and below sizes for low flow rates Specifications Item Specifications Remarks Size 8A (1/4 ) ~ 250A (10 ) Media Measured Flow Ranges Liquids and Gases Liquids: Water Max: ~ 250 m 3 /h Min: 0.01 ~ 0.1 m 3 /h Gases: Air Max: ~ 4000 Nm 3 /h Min: 0.5 ~ 5 Nm 3 /h Normal Condition: 20, 0 MPa Operating Temperature Operating Pressure Process Connections Flow Directions Materials Accuracy Turdown Ratio (Rangeability) Outputs Enclosure (Indictor) - 20 ~ 120 Optionally up to 150 Max. 4.1 MpaG at ambient temperature Max. 3.3 MpaG at 120 Flanges: JIS, ANSI, DIN, etc. Screws: NPT, PT, etc. Sanitary Ferrule Bottom to Top Bottom to Top Side Bottom Side to Top Side Side to Side Taper Tube: SUS 304, SUS 316, SUS 316L, PVC, etc. Float: SUS 304, SUS 316, SUS 316L, PVC, etc. Flange: Carbon Steel, SUS 304, SUS 316, SUS 316L, SCS13, SCS 14, PVC, etc. ± 2% of Full Scale 10:1 4-20mA (2-wire) 4-20mA with HART (2-wire) Alarm Switch Contacts Weather Proof (IP65) Intrinsic Safety (Exia II CT6) Flame Proof (Exia II CT6) 3

MAXIFLO TM KM Series Metal Tube Rotameters Model Code Model Selection Guide KM Description Code Connection Flange F Screw Sanitary N FS Indicator Square Aluminum Case for Meter Length (Face to Face) under 250mm A Dial Aluminum Case for Meter Length (Face to Face) under 250mm Dial Stainless Steel Case for Meter Length (Face to Face) under 250mm Square Aluminum Case for Meter Length (Face to Face) over 350mm Float Axle Indicator Side Indicator Mechanical Scale Index with Digital Indicator (Flow Rate & Total) B C J E G Q Flow Direction Bottom to Top 1 Bottom to Top Side 2 Bottom Side to Top 3 Bottom Side to Top Side 4 Side to Side 5 Material SUS 304 B SUS 316 SUS 316L PVC Teflon-Lining for Wetted Part on the Body Material Special C D P T X Options 4-20mA Output S 4-20mA with HART Pulse Output (Only for Q type indicator) 1-point Alarm Contact (Reed Switch) 2-point Alarm Contact (Reed Switch) 1-point Alarm Contact (Fiber Sensor) Cooling Fin Damper Full Heat Jacket Semi Heat Jacket Explosion Proof Enclosure Control Valve Reducer Pipe Large Flow Air Chamber SH S2 R1 R2 F1 CF DR FJ SJ EX GV LF AC 4 www.maxiflo.co.kr

MAXIFLO TM KM Series Metal Tube Rotameters Flow Directions, Flow Rates, Dimensions and Weights Bottom to Top (KMF-1-B) Bottom Side to Top Side (KMF-4-B) Bottom to Top Side (KMF-2-B) Bottom Side to Top (KMF-3-B) Side to Side (KMF-5-B) KMF-1-B Liquid (m 3 /h) Gas (Nm 3 /h) L (mm) Weight (Kg) 15A 0.1 ~ 1 1.0 ~ 10 250 7 20A 0.15 ~ 1.5 3 ~ 30 250 8 25A 0.4 ~ 4 10 ~ 100 250 8.5 32A 0.6 ~ 6 15 ~ 150 250 10 40A 1 ~ 10 20 ~ 200 250 11 50A 1.5 ~ 15 25 ~ 250 250 12 65A 2.5 ~ 25 60 ~ 600 250 13 80A 4 ~ 40 100 ~ 1000 250 14 100A 7 ~ 70 180 ~ 1800 250 20 125A 12 ~ 120 230 ~ 2300 250 25 150A 18 ~ 180 300 ~ 3000 250 34 200A ~ 200 - - 250A ~ 250 - - KMF-2/3-B Liquid (m 3 /h) Gas (Nm 3 /h) L (mm) A (mm) Weight 15A 0.1 ~ 1.0 1.5 ~ 15 250 100 8 20A 0.2 ~ 2.0 4.0 ~ 40 250 100 9 25A 0.4 ~ 4.0 8.0 ~ 80 250 100 10 32A 0.6 ~ 60 10 ~ 100 250 100 12 40A 1 ~ 10 15 ~ 150 250 100 13 50A 1.5 ~ 15 25 ~ 250 250 100 18 65A 2.5 ~ 25 45 ~ 450 350 150 25 80A 4 ~ 40 80 ~ 800 350 150 33 100A 6.5 ~ 65 180 ~ 1800 350 150 50 125A 10 ~ 100 250 ~ 2500 370 250 72 150A 18 ~ 180-480 250 95 KMF-4-B Liquid (m 3 /h) Gas (Nm 3 /h) L (mm) Weight (Kg) 15A 0.1 ~ 1.0 2 ~ 20 300 5.5 20A 0.2 ~ 2.0 4.0 ~ 40 350 6.5 25A 0.4 ~ 4.0 12 ~ 120 350 9 32A 0.6 ~ 60 15 ~ 150 350 9 40A 1 ~ 10 20 ~ 200 38 13 50A 2 ~ 20 40 ~ 400 420 17 65A 3 ~ 30 80 ~ 800 460 26 80A 4 ~ 40 150 ~ 1500 480 32 100A 8 ~ 80 250 ~ 2500 550 45 125A 14 ~ 140 450 ~ 4500 570 65 150A 22 ~ 220 650 ~ 6500 590 85 KMF-5-B Liquid (m 3 /h) Gas (Nm 3 /h) L (mm) Weight (Kg) 15A 0.1 ~ 1.0 1.5 ~ 15 160 10 20A 0.2 ~ 2.0 5.0 ~ 50 160 12 25A 0.4 ~ 4.0 10 ~ 100 180 14 32A 0.6 ~ 60 15 ~ 150 200 16 40A 1 ~ 10 20 ~ 200 240 18 50A 1.5 ~ 15 30 ~ 300 260 22 65A 2.5 ~ 25 60 ~ 600 340 35 80A 4 ~ 40 100 ~ 1000 360 42 100A 6.5 ~ 65 150 ~ 1500 360 62 125A 10 ~ 100 250 ~ 2500 440 93 150A 18 ~ 150 450 ~ 4500 440 115 www.maxiflo.co.kr 5

MAXIFLO TM KM Series Metal Tube Rotameters Indicator Options Option Code - J - Option Code - A - Option Code - B - Mechanical Scale Index for Face to Face <= 350mm Material: Cast Aluminum Square Scaled Mechanical Index for Face to Face <=250mm Material: Cast Aluminum Round Scaled Mechanical Index for Face to Face <=250mm Material: Cast Aluminum Option Code - E - Option Code - G - Option Code - Q - Float Axle Indicator Scaled Mechanical Index attached on the Side Material: Cast Aluminum Round Scaled Mechanical Index for Face to Face <=250mm Material: Cast Aluminum Output Options (Code: S1, S2, R1, R2 and F1) Output Description Remarks 4-20mA Alarm Contact Loop powered, 2 wire type 1 point or 2 point contacts, Reed Switch type Rating: AC250V, 0.5A or DC 125V, 0.5A 1 point contact, Fiber type The flow range for the output is set at the factory. Pulse Output Open Collector type Available only with Q type indicator 6 www.maxiflo.co.kr

MAXIFLO TM KM Series Metal Tube Rotameters Damper, Cooling Fin and Heat Jacket Options (Code: DR, CF, FJ and SJ) Explosion Proof Enclosure (Code: EX) EXd IIC T6 (KTL Certified) Reducer Pipe Large Flow (Code: LF) This option is applied to sizes from 65A. The flow sensing part (tapered tube) is compacted into the section highlighted in pink color, while the normal types have flow sensing part (tapered tube) into the longer meter body highlighted in grey color. Air Chamber (Code: AC) The air chamber is available as an option for the Axle Type Indicator model (Indicator option code: E). The air chamber blocks the liquid from entering into the indicator. www.maxiflo.co.kr 7

MAXIFLO TM KMS Series Metal Tube Rotameters Model Code Model Selection Guide KMS Description Code Connection Flange F Screw N Flow Direction Bottom to Top 1 Bottom to Top Side 2 Bottom Side to Top 3 Bottom Side to Top Side 4 Material SUS 304 B Options SUS 316 SUS 316L Special 1-point Alarm Contact (Reed Switch) Control Valve C D X R1 GV Flow Rates, Dimensions and Weights KMS-F-1-B Liquid (L/hr) Gas (Nm 3 /hr) 8A 5 ~ 50 0.3 ~ 3 Length (mm) Weight (kg) 3.5 10A 5 ~ 100 0.3 ~ 5 4 15A 5 ~ 150 1 ~ 10 280 5.5 20A 5 ~ 300 5 ~ 15 7 25A 5 ~ 450 8 ~ 25 8 Flange Connection KMS-N-1-B Liquid (L/hr) Gas (Nm 3 /hr) 8A 5 ~ 50 0.3 ~ 3 Length (mm) Weight (kg) 3 10A 5 ~ 100 0.3 ~ 5 3.5 15A 5 ~ 150 1 ~ 10 280 4.5 20A 5 ~ 300 5 ~ 15 5 25A 5 ~ 450 8 ~ 25 6 Screw Connection 8 www.maxiflo.co.kr

MAXIFLO TM KMSS Series Metal Tube Rotameters Model Code Model Selection Guide KMSS Description Code Connection Flange F Screw N Indicator Metal Tube Magnetic Coupling M Metal Tube Magnetic Coupling with Protect Case M2 KMSS-M KMSS-M-R1 Flow Direction Bottom to Top 1 Left to Right 2 Right to Left 3 Material SUS 304 B Options SUS 316 Special 1-point Alarm Contact (Reed Switch) C X R1 KMSS-M2 KMSS-M2-R1 2-point Alarm Contact (Reed Switch) R2 Specifications Item Specifications Remarks Size 8A (1/4 ) ~ 25A (1 ) Media Measured Liquids and Gases with Low Viscosity Available Scale Range Min. 0.2 ~ 2 L/min, Max. 15 ~ 150 L/min Max. Temperature 100 Optionally 180 Max. Pressure 1.0 MPa Connection Type RC, NPT, JIS, ANSI, DIN, etc. Accuracy Indicator - ±5%, FS, Alarm Setting - ±3%, FS Flow Rates, Dimensions and Weights Flow Rate Size Length (mm) Weight (kg) KMSS-M KMSS-M2 Liquid (L/hr) Gas (Nm 3 /hr) Liquid (L/hr) Gas (Nm 3 /hr) Min. Max. Min. Max. Min. Max. Min. Max. 8A 2 ~ 5 ~ 250 ~ 0.3 ~ 5 ~ 5 ~ 250 ~ 0.3 ~ 3 10A 2.5 ~ 5 ~ 600 ~ 0.3 ~ 15 ~ 5 ~ 600 ~ 0.3 ~ 5 15A 180 4 ~ 5 ~ 900 ~ 1 ~ 30 ~ 5 ~ 900 ~ 1 ~ 10 20A 5 ~ 5 ~ 1500 ~ 5 ~ 50 ~ 5 ~ 1500 ~ 5 ~ 15 25A 6 ~ 5 ~ 3000 ~ 8 ~ 80 ~ 5 ~ 3000 ~ 8 ~ 25 www.maxiflo.co.kr 9

We are here for you For further information, visit us at www.maxiflo.co.kr Subject to change without prior notice 12/08 Printed in Korea Seil Enterprise co. 2008 The information contained in this catalog contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in terms of the contract. All product designations may be trademarks or product names of Seil Enterprise Co. whose use by third parties for their own purposes could violate the rights of the owners. Seil Enterprise Co. Seoul Korea www.maxiflo.co.kr MAXIFLO TM is a registered trademark of Seil Enterprise Co.