ADA guidelines. 48" min. 30" min. 8 min. 34 max. to top of lavatory rim. 27 min. knee space to bottom of bowl

Similar documents
TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION

The fastest, most hygienic hand dryers.

Plumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1

Plumbing Guidelines 2012 IBC/ANSI A

The fastest to dry hands hygienically with HEPA filtered air. 1

50% quieter. Acoustically re-engineered to reduce noise.

Powered by the Dyson digital motor V4

Facilities Procedure for Accessibility or Compliance Related Requests:

ADA Checklist Transient Lodging, Hotels, Motels, Inns, Boarding Houses, Dormitories and similar facilities

SCOPE OF WORK. 506 N. Chadbourne Ave, San Angelo, TX. 1. Build and outfit kitchen are in accordance with established drawing

Unit # H ± 2,000 SF Width ± 25' Depth ± 80'

Electrical Information

PALMER FIXTURE FULL LINE PRODUCT CATALOG

Unit # 1038 ± 900 SF Width ± 15' Depth ± 60'

The Complete Range of Hand Dryers

Wash and dry hands at the sink.

ADA Checklist AIRPORTS

The fastest, most hygienic hand dryers.

The fastest way to dry hands hygenically with HEPA filtered air.

Unit # E ± 1,200 SF Width ± 20' Depth ± 60'

Paradise Marketplace. Unit # AOP +/- 1,600 SF +/- 12' +/- 11' +/- 8' 11'-7" +/- 85' +/- 74' +/- 20' MAIN FLOOR +/- 20' +/- 85' Width.

HAND DRYERS

Unit HH Gregg. ± 30,000 SF Width ±26' Lakeland Retail Center. Lease Outline Drawing. Unit HH Gregg. Depth ± 145' HVAC Units & Information

Partitions. Accessories. Lockers. No-Touch Washroom Accessories

Owner s manual. Free 5 year guarantee Register your guarantee at

The fastest to dry hands hygienically with HEPA filtered air.

The fastest to dry hands hygienically with HEPA filtered air.

The fastest, most hygienic hand dryer.

Dyson technology for business

Paradise Marketplace REAR FRONT. Unit # AOH +/- 1,700 SF +/- 20' +/- 85' +/- 85' +/- 20' MAIN FLOOR +/- 20' +/- 85' Width. Depth

Residential Accessibility Checklist - for Unit Types A and B With Connecticut Amendments Type A Units Accessibility Requirements rev.

REAR. Exit 5'-9" 6'-1" 8'-3" 6'-1" Freezer Entrance Stall

AV30 Advocate Lavatory System AV-Series

The problem with other hand dryers

YGIENEAUTOMATIC QUALITY EPA GREEN DURABLE ENERGY IGH SPEED COST SAVINGS. ADA Compliant EFFICIENT. Economical EFFICIENT HEPA. UIET IGH-speed GREEN

SUJET N X Document candidat

500H TOILET VESSEL LAVATORY FREESTANDING TUB

SECTION ELECTRIC HAND DRYERS

SECTION ELECTRIC HAND DRYERS. ** NOTE TO SPECIFIER ** Excel Dryer, Inc.; Electric Hand Dryers.

Chapter 6: Plumbing Elements and Facilities. 603 Toilet and Bathing Rooms Wheelchair Accessible Compartment

A New Dawn. In Washroom Hygiene. incorporating the

The fastest to dry hands hygienically with HEPA filtered air.

AV60 Advocate Lavatory System AV-Series

D & L A.D.A. SOLUTIONS 448 WEST MAIN ST. AUBURN,WA (800) HOUR FAX (206) FROM THE PARTS PEOPLE. SUPPLY and MFG.

Plot # R019A ± 74' ± 74' ± 65' Plot # R019A LEASE OUTLINE DRAWING GROSS LEASABLE AREA ± 4,631 S.F. DEMISING FRONT WIDTH DEPTH ± 13' ± 32' Lease Line

Mechanical Inspection Plumbing

FAUCET PARTS - EXPLODED VIEW Model: K-59

Hot Air Hand Dryer Range

CI/SfB (57.7) 1st Edition. Vent-Axia Hygiene Range

P-200T / P-200AT / P-230AT (115V / 60Hz)

SKSFD3604P 36-INCH BUILT-IN FRENCH DOOR REFRIGERATOR

Moen Commercial Products Eco-Performance Product Guide

BASIC OFFICE CLEANING GUIDE FOR GENERAL

Multi-Housing. Commercial Top Load Washer. Electronic BUILT FOR RELIABLE PERFORMANCE ELECTRONIC CONTROL. Rear Control

LVQD3 Verge with WashBar Technology LVQ-Series

AUTOMATIC TAPS. Infrared Taps. The perfect hygiene and water saving enhancement

THE VELOCITY PATTERN

Purpose of the Act. Learning Objectives. Latest with DOJ. Latest with DOJ. Texas Registered Accessibility Specialists Association

Pharmette Medicine Centers

Unit Size (HxWxD) x 11.6 x 3.9 / 339 x 295 x 100

Abbreviated Accessibility Checklist (Reception, Telephones, and Emergency Procedures) Reception Telephones

LVQD3 Verge with WashBar Technology LVQ-Series

Ligature Resistant Sensor Faucet Patent # US D635,386 #SAL-5011/SF370

Slimline, Energy Saving & Smart. It's the game changer!

RESTROOMS. Proper daily cleaning procedures. Custodial Best Practices

CONTINENTAL METAL PRODUCTS. Stainless Steel Healthcare Equipment Meeting the Demands of the OR. Proudly Made in the USA for over 65 years

F & S Caretaking Department Design Standards For New or Renovated U of T Premises February 2015

Restrooms. Proper daily cleaning procedures. Custodial Best Practices

OWNER S MANUAL. Model No. B-16 STAND PET DRYER

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

Building Dimensions Custom Dimensions Available

Oak Park Dr., Unit A, Mooresville, NC OVER 60 YEARS OF INNOVATION Product Guide

General Kitchen, Bath & Bedroom Remodeling Notes County of Marin, Building Inspection Division

FlaskScrubber & SteamScrubber. Laboratory Glassware Washers NEW! FlaskScrubber & SteamScrubber racks now interchangeable

2). Crane Co. 4). Kohler Co. 5). Universal-Rundle Corp. Revised September 29, 2017 Commercial Plumbing Fixtures

Corian Basins & Washplanes. The Bathroom Solution

Undercounter Units. 20 Call or Text for pricing on True and other great brands! UNDERCOUNTERS & WORKTOPS (19 24) REFRIGERATION

PAT BASIN MODEL 9121, 9131, & 9141

ASI Guide Specification

Business². Hand dryer. High Speed

TABLE 1 Electrical Specifications

TECHNICAL, ENVIRONMENTAL AND MECHANICAL SPECIFICATIONS

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

PLAN REVIEW CHECKLIST

The home of the hand dryer. Best Range, Best Price, Best Service

Installation and Operation Guide For

Owner s manual. Free 5 year guarantee Register your guarantee at

Flexible installation. German engineering. Bosch performance " Compact Laundry Brochure

LVQD1 Verge with WashBar Technology LVQ-Series

Thermo Scientific 1300 Series A2

TABLE 1 Electrical Specifications. Phase

Innovation in air purification unmatched air quality

You re looking at the smartest, cleanest, most cost-efficient way to dry your hands. Introducing

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

WASHROOM. Solutions Super fast, super efficient... UK market leaders in washroom solutions for over 45 years.

LD-5010 OmniDeck with WashBar 5000 Series

Express Lavatory System SS-Series

Laundry. Models Shown: ALW880QAW And ALE866SBW

Transcription:

ADA guidelines Mobility access within washroom facilities Because the Dyson Airblade Tap hand dryer is installed as a sensor operated dual use sink and hand drying unit within the restroom, it must maintain all lavatory sink knee and toe clearance requirements. The unit must be located on an accessible route and may not protrude into any required accessible clear area of other items, such as a door swing, required toilet clear area, urinal or fixed waste receptacle. The unit must be mounted within the reach range and space requirements. An accessible restroom is comprised of an accessible entrance, accessible turning space, and at least one type of accessible dispenser and fixture of each type. The Airblade AB09 Short Tap hand dryer would be considered a lavatory sink mounted unit, which should meet those requirements. 30" min. 760mm 48" min. 1220mm Clear floor ground space: Often accessibility code concepts are concerned with people in a seated position who use wheelchairs, which naturally limits the height and depth of their reach range. Because of the design of the Airblade Tap hand dryer, the front approach is the only way the unit can be properly used, therefore the side approach standards should not apply. A clear area in front of the unit should be a minimum of 30 wide by 48 of length. This area can overlap a circulation path but should not overlap other required accessible areas, for example, a lavatory sink in restrooms with access to more than one user at one time. Single use restrooms can overlap accessible areas due to the fact that they are used by only one person at a time. 34 max. to top of lavatory rim 27 min. knee space to bottom of bowl 8 min. AB09 Short Tap unit: AB09 Short Tap unit operable area would be approximately 37 above the finished floor, which would be considered to be within the proper accessible usability range. Like the Airblade V unit, with the understanding that hand drying occurs approximately 2 inches below the air edge blower, so the 37 usable range would be compliant. The current Dyson Technical Specification recommends 4 inches from the floor for air intake, which would put the motor bucket within the non-compliant range. It is recommended to maintain the 9 toe clearance for all installations. The power cord should be kept out of the toe clearance area. 9" min. * Source: ADA Accessibility Guidelines for Buildings and Facilities (ADAAG), Section 4. Accessible Elements and Spaces: Scope and Technical Requirements. Note: Diagrams not to scale.

ADA consulting AB10 Long Tap Non-Compliant AB09 Short Tap Compliant AB10 Long Tap unit: In reviewing the AB10 Long Tap unit, the additional 6 of height would move the operable area above the 40 finished floor accessible range when mounted on the required 34 high lavatory top surface making it non-compliant. There may be certain instances that the long unit would be ideal so it is recommended that a compliant short unit be installed with one or more long unit installation. 40 AFF Maximum AB11 Wall Tap unit: The AB11 Wall Tap unit should be compliant if the top of the sink stem is mounted at 40 above the finished floor. The reach range would generally be within the acceptable 20 distance for a standard accessible sink installation. Again, in those cases your design professional should be able to determine general compliance. Knee and toe clearances should always be maintained for any installation. Dyson Airblade AB09 short tap and AB11 wall tap accessible installation matrix: Yes/No Compliant Does the unit have the required front approach 30 x 48 clear floor clearance? Yes Yes Does the reach range exceed 40 maximum height above the finished floor surface? No Yes Is the hand dryer mounted at a height where it is considered a protruding object? No Yes Does the front edge project more than 4 into the path of travel when properly mounted? No Yes Does the operable part of the unit exceed the forward 20 reach range? No Yes Does the unit provide the proper 9 toe clearance? Yes Yes Conclusion Based on the review of the three Airblade Tap sink integral faucet-hand dryers, it is concluded that in a standard restroom lavatory installation the Airblade AB09 Short Tap and AB11 Wall Tap mounted at the correct height would be compliant. As always, if a front approach clear area with no conflicting overlapping accessible areas exists, then the unit should comply with accessible requirements. * Source: ADA Accessibility Guidelines for Buildings and Facilities (ADAAG), Section 4. Accessible Elements and Spaces: Scope and Technical Requirements. Note: Diagrams not to scale.

LOW VOLTAGE AND HIGH VOLTAGE TECHNICAL SPECIFICATION Electrical Input voltage: Low Voltage = 110-127 V, High Voltage = 208 V Frequency: Low Voltage = 50 or 60 Hz, subject to voltage (85-115 V at 50 Hz; 85-130 V at 60 Hz); High Voltage = 50 & 60 Hz Rated power: 1400 W Motor type: Dyson digital motor V4 brushless DC Motor Motor switching rate: 6,100 per second Motor speed: 92,000 rpm Amp: Recommended dedicated 15 amp circuit, Low voltage = 11.7 amps at 120V, High voltage = 7.3 amps Operating temperature range: 32 104 F Heater type: None Standby power consumption: Less than 0.5 W Product range (Select one) Construction AB09 Short AB10 Long AB11 Wall Tap construction: Stainless steel (brushed) Lead Free Under counter motor bucket: Molded ABS (main unit) also uses polycarbonate and polypropylene Part number/sku Low Voltage: 301848-01 High Voltage: 301841-01 Part number/sku Low Voltage: 301849-01 High Voltage: 301842-01 Part number/sku Low Voltage: 301850-01 High Voltage: 301843-01 Exterior screw type: Torx T15 Water ingress protection rating to IP35 Filter Double-life HEPA filter (glass fiber and fleece prelayer) Bacteria removal 99.97% at 0.3 microns Operation Touch-free infra-red activation Hand dry time measurement: 14 seconds* Operation lock-out period: 30 seconds Airspeed at apertures: 420 mph Maximum Altitude: 2,000m/6,561 ft. Operating airflow: Up to 7.92 gal/sec and 63.5 CFM Rated operating noise power: 85 db(a) Water operation Water flow rate: 1.06 gal/min Tap Aerator: 0.5 gal/min aerator outlet (Note: Optional.35 gal/min multi spray laminar aerator available as a service part) Tap power supply: Mains supply Water temperature control: Thermostatic mixer recommended (not supplied) Water pressure required: 14.5-116 psi Logistics Serial number prefix: AB09 AN5; AB10 AN6; AB11 AN7 Net weight: AB09 9.5 lbs.; AB10 10.1 lbs.; AB11 19.7 lbs. Packaged weight: AB09 13.4 lbs.; AB10 14.3 lbs.; AB11 25.9 lbs. Packaged dimensions: AB09 (H) 11 7 8" (W) 11 1 8" (D) 11 1 4"; AB10 (H) 10 7 8" (W) 17 1 4" (D) 11"; AB11 (H) 11 7 8" (W) 24" (D) 14 3 4" UPC barcodes: Low Voltage AB09: 885609001500, AB10: 885609001494, AB11: 885609001487; High Voltage AB09: 885609004402, AB10: 885609004419, AB11: 885609004426 Standard guarantee 5 year parts and 5 year limited labor warranty Sink specifications The Dyson Airblade Tap is compatible with most sink types. Ensure plugs are not installed in the sinks. See the Tap Pre-Installation Guide for more details. Sink dimensions: All sink measurements are internal unless stated otherwise. Sink width Min.: 13 3 4", Front to back Min.: 11 3 4"; Sing depth Min. 4"; Max. sink depth AB10 only: 7 7 8" (External measurement of vessel sink). Sink materials: Sinks with highly polished surfaces should be avoided e.g. shiny chrome. Porcelain or brushed metal are ideal. Accreditations Carbon Trust HACCP International NSF International AB09 Short and AB11 Wall are ADA compliant Contributes to LEED certification The Carbon Reduction Label is the registered trade mark of the Carbon Trust. HACCP International non-food certification mark is the registered trademark of HACCP International. HACCP International have certified Dyson products based on their recommended installation and operating conditions. The NSF logo is the registered trade mark of NSF International. * Dry time measured using Dyson test method 769 based on NSF P335 using a measurement of 0.1g residual moisture. For more information, please contact Dyson: 1-888-397-6622, www.dysonairblade.com, airbladeinfo@dyson.com

TECHNICAL SPECIFICATION FRONT ELEVATION SIDE ELEVATION 11 5 8" 2 1 2" 11 1 8" 6 1 4" 1 3 8" 14 5 8" Water 10 5 16" Rear electrical Floor 5 9 16" All dimensions shown in inches (+/- 3 16 inches) 7 7 16" FLOOR Tap dimensions Minimum clearance AB09 Height 6 1 4" Width 11 5 8" Depth 11 1 8" Z 4" clearance from floor. (ADA requires 9" toe clearance) Motor bucket dimensions AB09 Height 10 5 16" Width 5 9 16" Depth 7 7 16" For more information, please contact Dyson: 1-888-397-6622, www.dysonairblade.com, airbladeinfo@dyson.com

TECHNICAL SPECIFICATION FRONT ELEVATION 2 1 2" SIDE ELEVATION 11 1 8" 11 5 8" 12 1 8" 1 3 8" 14 5 8" Water 10 5 16" Rear electrical Floor 5 9 16" All dimensions shown in inches (+/- 3 16 inches) 7 7 16" FLOOR Tap dimensions Minimum clearance AB10 Height 12 1 8" Width 11 5 8" Depth 11 1 8" Z 4" clearance from floor. (ADA requires 9" toe clearance) Motor bucket dimensions AB10 Height 10 5 16" Width 5 9 16" Depth 7 7 16" For more information, please contact Dyson: 1-888-397-6622, www.dysonairblade.com, airbladeinfo@dyson.com

TECHNICAL SPECIFICATION FRONT ELEVATION 10 11 16" 12" 7 5 8" 6" 11 5 8" 10 1 4" 10 3 4" 13 1 2" 24 1 2" Water entry point 14 9 16" 14 9 " 13 1 2" Electrical entry point 1 4" 1 11 16" 6 14 16" 3 11 16" 7 11 16" 1 3 8" FLOOR Tap dimensions AB11 Length 12 1 16" Width 11 5 8" Motor bucket dimensions AB11 Height 10 5 16" Width 5 9 16" Depth 7 7 16" All dimensions shown in inches (+/- 3 16 inches) For more information, please contact Dyson: 1-888-397-6622 www.dysonairblade.com airbladeinfo@dyson.com 3903955 09.17.14 2014 DYSON