Modeling a real backdraft incident fire

Similar documents
Fire Investigation in Italian Waste Treatment Plant: lessons learned and future development

Available online at ScienceDirect. Procedia Engineering 62 (2013 ) Charles M Fleischmann a, *, ZhiJian Chen b

Max Fire Box Users Guide

NUMERICAL SIMULATION OF THE NEW SOUTH WALES FIRE BRIGADE COMPARTMENT FIRE BEHAVIOUR TRAINING TEST CELL

ATTIC FIRES. Part 3 HEAVY SMOKE SHOWING

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

Cumru Township Fire Department 4/27/10 Standard Operating Guidelines Page: 1 of 6 Section 15.07

Topic: Mechanical Ventilation Refresher Reference #: DG Level of Instruction: In service personnel Time Required: 3 hours

2. Gas B. The column of hot gases, flames, and smoke rising above a fire; also called convection column, thermal updraft, or thermal column

CFD Model of a Specific Fire Scenario

ATTIC FIRES. Part 2 LIGHT SMOKE SHOWING

Research Needs for the Fire Safety Engineering Profession

Ventilation Effects on Fire Patterns during Post Flashover Burning

Sprinklers Modeling for Tunnel Road Fire Fighting

Essentials of Fire Fighting 6 th Edition Firefighter I

Numerical simulation of fire and smoke transport for an old-style apartment fire

DCN: ENGINE COMPANY OPERATIONS CHAPTER 4 March 15, 1997 FIRE SCENE OPERATIONS

5B-3 6th Asia-Oceania Symposium on Fire Science and Technology 17-20, March, 2004, Daegu, Korea

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

An experimental study of the impact of tunnel suppression on tunnel ventilation

Numerical simulation of fire and smoke transport for an old-style apartment fire

Fire Patterns. Introduction. Skills Objectives. Fire Effects and Fire Patterns (2 of 2) 12/20/ Knowledge Objectives

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

CERBERUS: A NEW MODEL TO ESTIMATE SIZE AND SPREAD FOR FIRES IN TUNNELS WITH LONGITUDINAL VENTILATION

Evolution in the knowledge about interior firefighting

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

Aspirating Gas Detection CFD Modelling Predicts Application Performance

Carbon Monoxide Poisoning

Fire safety systems. Behaviour of fires

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

So, How do Fire Starts & Spreads? A question we need to understand and appreciate the dynamics of fire life cycle.

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

OXYGEN. 21% in air. Does not burn - Supports combustion. Increased oxygen will intensify burning

Smoke Management in High-Rise Structures

ARC MAPPING Things to Consider

Considerations in the Design of Smoke Management Systems for Atriums

Explosion Protection of an Armoured Vehicle Crew Compartment with Water Mist. Andrew Kim and George Crampton

Modeling water-mist based suppression of 34 GJ car-deck fires using FDS

A study for a fire spread mechanism of residential buildings with numerical modeling

A Comparison of Carbon Monoxide Gas Sensing to Particle Smoke Detection in Residential Fire Scenarios

New insights into ventilation

qüé=`üáãåéó An effective chimney is an important part of any successful wood-burning system.

Gothenburg dance hall, Sweden, 1998

REED COLLEGE DEPARTMENT OF COMMUNITY SAFETY DEPARTMENTAL DIRECTIVE CSO FIRE & FIRE ALARM SYSTEM RESPONSE GUIDELINES

How design fires can be used in fire hazard analysis

1893 Chicago World s Fair

Figure 1. Structure Used For the Simulations.

TIMOTHY R. SZYMANSKI Instructor

ANALYSIS OF SMOKE MOVEMENT IN A BUILDING VIA ELEVATOR SHAFTS

Date and Time of Incident. Jan 28, Breakout at 00:55 (approx) Detected at 00:55 Notified by a call to the police station Extinguished by 01:50

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

Design of Fire safety in Multi Occupancy Residential Accommodation

Fire is No Accident Fire is No Accident It can be prevented.

RESULTS FROM HOUSE APPLIANCE SAFETY AND DEPRESSURIZATION TESTS CONDUCTED ON SINGLE FAMILY HOUSES UNDERGOING SOUND INSULATION

IFE Level 4 Certificate in Fire Science and Fire Safety

SIMULATION OF A COMPARTMENT FLASHOVER FIRE USING HAND CALCULATIONS, ZONE MODELS AND A FIELD MODEL

PREDICTING SMOKE DETECTOR ACTIVATION USING THE FIRE DYNAMICS SIMULATOR

Full-Scale Measurement and Numerical Analysis of Liquefied Petroleum Gas Water Heaters with Ventilation Factors in Balcony

Chapter 17, Initiating Devices

Experiments to Validate the NRCC Smoke Movement Model for Fire Risk-Cost Assessment

Using FDS Modelling to Establish Performance Criteria for Water Mist Systems on Very Large Fires in Tunnels

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

IFE Level 3 Diploma in Fire Science and Fire Safety

Third Runway Project APM Depot Fire Engineering Design. Presented by Ir Wilson Sau-kit TSANG

Additional Materials: Instructor s PowerPoint, Question Files

Test One: The Uncontrolled Compartment Fire

Second Revision No. 1-NFPA [ Section No. 2.2 ] Submitter Information Verification. Committee Statement

Fire Department Arson Unit. Investigation Report

ABSTRACT. Stephen Kerber, Master of Science, Dr. James Milke, Fire Protection Engineering

Unit 6: Fire Investigation

Westbury Fire Department: Hose Company 2 Drill 7/24/14 Thinking Beyond the Obvious or the Norm

INSTRUCTOR GUIDE COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 1 TOPIC: ORIENTATION AND FIRE BEHAVIOR LEVEL OF INSTRUCTION:

Recent Advances in Fire Suppression Modeling Issues & Perspectives of Fire Safety Engineering Applications

Fire Investigation Terms

VIRTUAL FIRES via COMPUTERS

Hazardous Material Safety Program

Smoke Layer Height and Heat Flow through a Door

Tunnel Fire Dynamics and Evacuation Simulations

6B-2 6th Asia-Oceania Symposium on Fire Science and Technology 17-20, March, 2004, Daegu, Korea

Water Mist-Based Fire Suppression Modelling of an Office Space Scenario

Modelling Concepts for the Risk-cost Assessment Model FIRECAMTM and its Application to a Canadian Government Office Building

FINDINGS FROM FIRE TESTS IN TUNNEL CONSTRUCTIONS WITH VENTILATION SYSTEMS AND FIXED FIRE SUPPRESSION SYSTEMS

LESSON ONE FIREFIGHTER I Fire Behavior

Refining and Petrochemical Heater trouble shooting

Y. ORMIERES. Fire risk analysis method for nuclear installations

COMPARISON OF CFD MODELLING WITH FIRE TESTS Comparison of CFD Modelling with Results of Full Scale Compartment Fire Tests in a Residential Unit

PRELIMINARY ANALYSIS OF THE NUMBER OF OCCUPANTS, FIRE GROWTH, DETECTION TIMES AND PRE-MOVEMENT TIMES FOR PROBABILISTIC RISK ASSESSMENT

NYU RESIDENTIAL FIRE SAFETY PLAN PART I - BUILDING INFORMATION SECTION

Case Study 1 Underground Car Park

Yunyong P. Utiskul, Ph.D., P.E., CFEI

Table EXIT ACCESS TRAVEL DISTANCE a OCCUPANCY SYSTEM SYSTEM. A, E, F-1, I-1, M, b,d R, S-1. B c. F-2, S-2, U c

Fire Research and Education at the University of Maryland

Home Fires Involving Heating Equipment

Structural Firefighting Policy

CRJ 248: Scientific Investigation. Chapter 14: Arson and Explosive Evidence

Real-scale dwelling fire tests with regard to tenability criteria

IMPORTANCE of FIREGROUND VENTILATION PRACTICES and DYNAMICS IN FIREFIGHTING (PART I)

Fire Investigation Terms

Combustion Safety. RESNET Conference San Antonio, TX February 27, Presented by Rich Moore Lightly Treading Energy & Design Denver, CO

Table of Contents. Preface... xiv Introduction... 1 Purpose and Scope... 2 Key Information... 2

Transcription:

Advanced Computational Methods in Heat Transfer IX 279 Modeling a real backdraft incident fire A. Tinaburri 1 & M. Mazzaro 2 1 Central Direction for Prevention and Technical Safety, Firefighters, Public Rescue and Civil Defence Department, Ministry of the Interior, Italy 2 Central Direction for Emergency and Technical Rescue, Firefighters, Public Rescue and Civil Defence Department, Ministry of the Interior, Italy Abstract This paper reports the fire conditions that occurred in a townhouse and the results of software simulations that were performed to provide insight on the peculiar thermal conditions that developed. Fire rescue was called by the occupants of the house when they became aware that smoky conditions were developing on the second floor. Two of the firefighters entered the bedroom where the smoke was originating from and a short time after a flame front invested them while propagating them backward into the stairwell. The post fire investigation determined that the fire started as a consequence of the smoldering combustion of material contained in a wardrobe located adjacent to one of the room walls. A simulation scenario was developed based on the information obtained on the actual building geometry, material thermal properties and the fire behaviour. The calculations that best represented the actual fire conditions indicate that the partial opening of the window and bedroom door provided outside air (oxygen) to a pre-heated, under ventilated fire compartment. Keywords: smouldering combustion, backdraft, fire models, fire investigation. 1 Introduction Part of the mission of the department of the firefighters, public rescue and civil defence is to conduct basic and applied fire research, including fire investigations, for the purposes of understanding fundamental fire behaviour and to reduce losses from fire. On February 3, 2003, a fire in a townhouse near Lucca doi:10.2495/ht060281

280 Advanced Computational Methods in Heat Transfer IX caused two firefighters to be injured. Investigation on fire causes were conducted by the local fire brigade and police station. Computer simulations were made to provide insight on the fire development and thermal conditions that may have existed in the townhouse during the fire. 2 Fire scenario The fire occurred in a masonry dwelling of ordinary construction. The building was inserted between two others that were not involved and contained only one apartment on three stories, connected through an enclosed stairway, with the basement entrance faced on the access road (Figure 1). The occupants of the house, while staying in the first floor rooms, became aware that, starting from a closed bedroom, smoky conditions were developing in the second floor. They exited the residence via the front door at ground level and called for the fire rescue. The first engine arrived on the fire scene in approximately 20 minutes and entered in the house via the front door. Conditions on the second floor were described as smoky, with smoke coming from the doorway and the window of a room located in the second floor. To lessen the smoke level and provide ventilation, the firefighters started to open partially the front window. Figure 1: External view of the 2nd floor room originating the fire and of the window that vented out the backdraft flame (pointed by the arrow) All the pictures have been taken about one hour later the fire event. After some minutes, two of the firefighters, entered the house and through the stairs, reached the second floor room. They reported that the second floor was at that time fully charged with smoke. They opened the door, entered the bedroom and while orienteering to reach the window, one of them saw in the dark a small flame. Soon after a flame front invested them, while propagating backward to the doorway and then into the stairwell. The flame vented out through a window left

Advanced Computational Methods in Heat Transfer IX 281 open located in proximity of the first floor on the front of the house and then extinguished after few seconds. Thanks to the personnel protection equipment, the two firefighters did not suffer appreciable burn injuries. An amateur video has recorded the scene and became an important source of information when later reviewed by the fire department. The tape showed the flame venting out through the only fully open window, without appreciable flame persistence. Damage to the house was mainly limited to the bedroom originating the fire a closed door prevented fire spreading. There was no fire extension to the other rooms or to the adjacent buildings and no structural damage observed. Figure 2: Detail of the 2 nd floor stairway lamp showing cover destruction. Figure 3: 2 nd floor stairway. The room originating the fire is on the left side. The stairway from the first to the second floor showed only few appreciable effect of the backdraft flame impingement on the ceiling and walls except for the destruction of the lamp cover located on the second floor ceiling (Figure 2), the partial melting of the light switch located on the left side, near the bedroom doorway (Figure 3). The ladder shown in Figure 3 was used by the firefighters to access the wooden roof structure, after extinguishing the fire, to verify that no fire propagation and smoldering combustion had occurred. The bedroom had significant deposits of soot throughout, with limited thermal damage. The gypsum board walls and ceiling remained intact. A wardrobe and some furniture located adjacently two walls were completely destroyed by the fire (Figures 4, 5 and 6).

282 Advanced Computational Methods in Heat Transfer IX Figure 4: Detail of one wall in the room originating the fire. The wardrobe gone completely destroyed was located near this wall. Figure 5: Detail of one room wall (next to Figure 4). Figure 6: Detail of the bedroom door (next to Figure 5). The bed showed signs of pyrolysis and limited burning on the upper portions of the back cushions (Figure 7). The triangular shape of the combusted part was attributed to the fire propagation from adjacent furniture, gone completely carbonized.

Advanced Computational Methods in Heat Transfer IX 283 Figure 7: Detail of the bed. 3 Cause and origin The information provided by the firefighters involved and the evidence described was of a classic backdraft, usually persisting only few seconds before exhausting its fuel supply. The post fire investigation determined that the fire started as a consequence of the smoldering combustion of the material contained in a wardrobe, located adjacent to a wall that contained inside a flue gas duct of an adjacent house chimney. A slow soot combustion fire occurred in the flue gas duct. This initial event provided the heat source that, by thermal conduction through the poor insulating wall, originated the smoldering combustion inside the wardrobe. It was witnessed that the wardrobe got usually warm even during normal chimney operation. The occupant and the firefighters confirmed that the bedroom door and the window were initially kept closed, so that there were negligible external source of combustion air. After the firefighters opened slightly the bedroom window, acting from the outside, an amateur video shows an increase in the smoke production. However, when the firefighters opened the door, the resulting fire gases, rich in carbon monoxide, flowed downward into the stairwell with high velocity and exited through the only open window located in proximity of the first floor. 4 Model results NIST has developed a computational fluid dynamics (CFD) fire model using large eddy simulation (LES) techniques, called Fire Dynamics Simulator (FDS). The CFD model requires that the room or building of interest be divided into small rectangular control volumes or computational cells. The CFD model computes the density, velocity, temperature, pressure and species concentration of the gas in each cell based on the conservation laws of mass, momentum, and

284 Advanced Computational Methods in Heat Transfer IX energy to model the movement of fire gases. FDS utilizes material properties of the furnishings, walls, floors, and ceilings to simulate fire spread. A complete description of the FDS model is given in reference [1]. FDS requires as inputs the geometry of the building, the computational cell size, the location of the ignition source, the ignition source, thermal properties of walls, furnishings and the size, location, and timing of vent openings to the outside which critically influence fire growth and spread. The timing of the vent openings, used in the simulation, are based on an approximate timeline of the fire fighting activities and on a real time video taken by an amateur. The floor plan of the second floor of the townhouse and of the stairwell are shown in Figure 8. The placement and size of the interior walls, doorways, and windows were taken from the dimensioned floor plans drawn by personnel of the Fire Brigade. access road window window bed bedroom wardrobe Fluegas duct Stairway 2 nd floor Furniture Figure 8: 2nd floor plan view. As in the fire incident, the bedroom window and door were kept closed during the simulation, till the firefighters opened them. The front window on the second floor was kept closed while the one located on the first floor, where the backdraft was vented out (see Figure 1), remained opened during the entire simulation. For the FDS simulation, a specified heat flux from the wall adjacent to the wardrobe was used to start the fire growth as the ignition source. Starting the simulation with a flaming ignition enabled fire development to be modeled within a reasonable computational time. The actual fire may have taken several hours to develop to the flaming stage, if eventually reached. As the simulated fire spreads from the ignition source, and then to other items in the room, it depletes its supply of oxygen for combustion. When a fire occurs in a closed room where the only ventilation is due to leakage, it can become limited by the available oxygen and produce large amounts of unburned fuel. If the leakage rate is low enough

Advanced Computational Methods in Heat Transfer IX 285 the fire may enter a smoldering stage. Temperatures within the bedroom has been estimated much lower than flashover temperatures but significantly higher than the ambient. Upon venting, a gravity current carries fresh air into the compartment. This air mixes with the excess pyrolyzates producing a flammable pre-mixed gas, which can be ignited by a flame or a glowing ember, generating a flame front moving through the compartment toward a vent. This entire process: the accumulation of unburned gaseous fuel, the propagation of an oxygen rich gravity current creating a mixed region and carrying it to the ignition source, the ignition and propagation of an eventually turbulent deflagration vented out, altogether constitutes a backdraft [2, 3]. Figure 9: Perspective view of townhouse. The FDS calculations supported the hypothesis that unburned fuel and CO accumulated in the bedroom, resulting in a backdraft after few minutes of venting the bedroom. Reported conditions such as smoke accumulation in the second floor and the exotic propagation of the deflagration downward the stairway were reproduced by the model (Figure 10). Some assumptions were necessary in performing these calculations, which may have an impact on the model s predictions. The results are sensitive to the volume of the apartment and to the size and locations of ventilation openings. All of these were known by actual measurements taken by the fire department during their investigation and by witness report and a real time amateur video. It was reported that the bedroom door and window were closed, up to firefighters arrival. So the assumption of no additional leakage was justified. The combustion was predominately ventilation controlled, making the results insensitive to fuel loading and the specific burning characteristics of the fuel. The generation rate of unburned fuel and CO in poor ventilation conditions should be affected by energy feedback from the

286 Advanced Computational Methods in Heat Transfer IX environment and any flames present during the time of ventilation controlled combustion. The FDS model does not contain such a self-consistent combustion model, so the quantity of unburned fuel and CO production has been estimated and subject to a sensitivity analysis. The field data of the heat release per unit volume during backdraft evolution are reported in Figure 10. Figure 10: Field data of the heat release per unit volume (kw/m 3 ) during backdraft evolution. A temperature profile inside the bedroom during backdraft is shown in Figure 11. The values are in the range of 200-250 C, much lower than flashover temperatures as expected. This figure is compatible with the observed fire scenario and are indeed necessary to support the production of relatively dense unburned fuel, prior to cold air mixing, necessary to allow downward flame propagation from second floor to the first floor window, were the deflagration was vented out. 5 Lessons learned The fire service community has long recognized the hazards associated with backdrafts. Typically, firefighters are involved in initial search and rescue or suppression operations when the backdraft occurs. Current tactics for reducing the backdraft hazards are to vent the structure prior to entry. However, the ventilation process is often a second priority to the rescue operation. Indeed,

Advanced Computational Methods in Heat Transfer IX 287 unless it is restricted to roof venting, ventilation may facilitate rather than prevent a backdraft. Even if neither the occupant nor the firefighters get seriously injured, it is fundamental to analyze the incident to increase the overall consciousness of safety culture and avoid the risk that valuable information get lost unreported as because no one had been injured. It has also pointed out the benefits of the use of modern, computer fire modeling in the reconstruction of fire incidents to understand critical factors for mitigating their impacts. Figure 11: Temperature profile inside the bedroom ( C) during backdraft. References [1] Mc Grattan, K.B., Baum, H.R., Rehm, R.G., Hamins, A. & Forney, G.P., Fire Dynamics Simulator Technical Reference Guide, NIST Special Publication 1018, Nat. Inst. Stand. Tech., Gaithersburg, MD, USA, 2004. [2] Fleischmann, C.M., Backdraft phenomena, NIST-GCR-94-646, Nat. Inst. Stand. Tech., Gaithersburg, MD, USA, 1994. [3] Fleischmann, C.M., Pagni, P.J. & Williamson,R.B, Quantitative backdraft experiments. Proceedings of the International Association for Fire Safety Science 4th International Symposium, July 13-17, 1994, Ottawa, Canada, IAFSS, Boston, MA, USA, T. Kashiwagi, ed., pp. 337-348, 1994.