Auxiliary Electric Heater Interface kit ASKHTR

Similar documents
AG Series Electric Heaters

ACDU02 Communicating Service Tool

BasicTroubleshooting Information and Guidelines

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

AHWG Remote Mount Hot Water Generator Module for TTP Series Outdoor Split Unit

ATC32U01 Basic Operation Guide

CXM/DXM. Application, Operation & Maintenance Instructions 97B0003N08 Revision: 01/10/05. CXM/DXM Digital Heat Pump Controllers.

ATC32U03 igate Communicating, Programmable Thermostat

ATC32U01 igate Communicating, Programmable Thermostat

ClimaDry II. Table of Contents. ClimaDry II Whole House Dehumidification Option. Tranquility 30 Tranquility 20

ATP21W02 CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS REMOVING OLD THERMOSTAT 2 THERMOSTAT DETAILS

Tranquility Digital Quick Start Guide

AHWG Remote Mount Hot Water Generator Module

ATC32U02 igate Communicating, Programmable Thermostat

Tranquility Digital Quick Start Guide

DXM CONTROLS. DXM Digital Heat Pump Controllers. Application, Operation, & Maintenance. Table of Contents

ATC32U01 igate Communicating, Programmable Thermostat

igate ClimaZone Zoning Panel

THE TRANQUILITY 16 COMPACT (TC) SERIES

AG Series Electric Heaters

TRANQUILITY WATER-TO-WATER SERIES

ATC32U01A Communicating, Programmable Thermostat

Tranquility Modular Water-to-Water (TMW) Series

UNIT DIGITAL CONTROLS APPLICATION, OPERATION & MAINTENANCE

Commercial and Residential Water Source Heat Pumps Boiler/Tower and Geothermal Applications

DXM2 Digital Heat Pump Controller

Installation Instructions

Commercial Thermostat

Tranquility Vertical Stack (TSL) Series

Tranquility Water-to-Water (THW) Series

Tranquility Brazed Plate Geothermal Closed Loop Water-to-Water (TBW) Series

Tranquility (THW) Water-To-Water Series. WATER-TO-WATER SYSTEMS SIZES Hz [10 kw]

Application, Operation and Maintenance Guide. DXM Electronic Heat Pump Control

GENESIS WATER-TO-WATER (GSW) SERIES. Table of Contents

Tranquility Coaxial Geothermal Open Loop Water-to-Water (TCW) Series

HRC Series Commercial Console Water-Source Heat Pumps 60Hz

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

Tranquility Vertical Stack (TSM) Series

Installation, Operation & Maintenance: Field-Installed Electric Heater for RXT Series Units

Tranquility Digital Air Handler (TAH)

SM Field Installed Electric Heat Kit

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Installation Instructions

Installation Instructions

CLIMATEMASTER GEOTHERMAL HEATING AND COOLING

Installation, Operation & Service Manual

THW Series. Table of Contents. Tranquility Water-to-Water (THW) Series 60Hz Models

Installation Instructions

Installation Instructions

VHS Series. Installation, Operation & Maintenance Instructions. 816 Series Vertical Stack Water Source Heat Pumps TABLE OF CONTENTS

Commercial Thermostat Submittal Data

KIT IOM

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

INSTALLATION & OPERATION GUIDE

Installation, Start-Up, and Operating Instructions

INSTALLATION INSTRUCTIONS

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

Installation & Operation Instructions

ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY (Corporate Sales) 85 Middle Road Dunkirk, NY ARH-1 ARH-2 ARH-3

I/O ZONE 560/583 AND OPERATION MANUAL

GT-X. 50YBV Ultra High Efficiency Vertical Two-Stage Geothermal System. Installation, Operation & Maintenance Instructions TABLE OF CONTENTS

Installation Instructions

CommStat 4 Controller

PRO Installation. Touch Wi-Fi Thermostat

Pioneer Gold Controller Technical Guide. Pioneer Gold Controller Code: Version 1.1 Used with AAON WSHP WV Series Vertical and WH Series Horizontal

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

Table of Contents. Commercial Horizontal & Vertical Packaged Water-Source Heat Pumps

TRILOGY. 45 GEOTHERMAL SYSTEMS The World s Most Advanced Heating and Cooling System CLIMATEMASTER GEOTHERMAL HEATING AND COOLING

CCH/CCW, VFC/VFW, MHC/MHW, LVC/LVW

Tranquility Vertical Stack (TSL) Series

Power Supply Display Module PSDM. Installation and Operation Manual

HYDRO-AIR ZONING CONTROLS ARH-1, ARH-2, ARH-3

Industrial Flanged Immersion Heaters

P/N f. HomeWorks QS Palladiom Thermostat Configuration Guide

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

Owner s Manual. Part Number 33CSCPACHP-01

HYDRO-AIR ZONING CONTROLS ARH-1, ARH-2, ARH-3

(HSTAT Series) Instruction Manual

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

SHConDEMAND. True Redundancy. Heating. Cooling. Simultaneous. Efficient. Reliable

AE R1 October to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors

B SERIES ELECTRIC FURNACE

Tranquility Console (TRC) Series

Pioneer Gold Controller Technical Guide

PRO Installation. Touch Wi-Fi Thermostat

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

User s Manual. THE iq Drive SYSTEM USER S INFORMATION IMPORTANT. Variable Speed Ultra-High SEER Split System IMPORTANT NOTE

Operation and Maintenance Manual OM MicroTech III Unit Controller with I/O Expansion Module for Two Compressor Water Source Heat Pumps

Installation and Maintenance Manual OM

FlashGuard 3000B Dual Lighting System Troubleshooting Guide

Installation Instructions

Installation Instructions Read and become familiar with these instructions before beginning installation.

Installation Instructions

4100U City and Relay Cards Installation Instructions

Installation Guide for models:

ABS HOPPER LID SWITCH KIT ASSEMBLY

User reference guide. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB

Transcription:

Auxiliary Electric Heater Interface kit ASKHTR Installation, Operation & Maintenance Table of Contents General Information 2 INSTRUCTIONS for 1: Boilerless 2 INSTRUCTIONS for 2: Supplemental 3 Typical Wiring Diagram 4 Typical Wiring Diagram 5 Revision History 8 97B0012N07 Revised: January 30, 2017

CLIMATEMASTER WATER-SOURCE HEAT PUMPS General Information Safety Warnings, cautions, and notices appear throughout this manual. Read these items carefully before attempting any installation, service, or troubleshooting of the equipment. All work to be performed by qualified service contractor. DANGER: Indicates an immediate hazardous situation, which if not avoided will result in death or serious injury. DANGER labels on unit access panels must be observed. WARNING: Indicates a potentially hazardous situation, which if not avoided could result in death or serious injury. CAUTION: Indicates a potentially hazardous situation or an unsafe practice, which if not avoided could result in minor or moderate injury or product or property damage. NOTICE: Notification of installation, operation, or maintenance information, which is important, but which is not hazard-related. WARNING! WARNING! The installation of water-source heat pumps and all associated components, parts, and accessories which make up the installation shall be in accordance with the regulations of ALL authorities having jurisdiction and MUST conform to all applicable codes. It is the responsibility of the installing contractor to determine and comply with ALL applicable codes and regulations. WARNING! WARNING! To avoid possible injury or death due to electrical shock, open the power supply disconnect switch and secure it in an open position during installation. CAUTION! CAUTION! Use only copper conductors for fi eld installed electrical wiring. Unit terminals are not designed to accept other types of conductors. DESCRIPTION: Kit contains 24 VDC relay, wires and harness. APPLICATION: This kit can be used for two applications: 1) For automatic changeover from heat pump heat to electric heat for boilerless applications. Also required AH Accessory Heater and unit must have DXM. Controller can be heat pump thermostat, MPC, or LON. Controller Y is connected to DXM Y, DXM- LT1 sensor in unit determines if unit will operate as compressor heat or electric heat. 2) For supplemental electric heat when using MPC. Also required AH Accessory Heater and unit must have MPC and either CXM or DXM. W signal from MPC is connected to W on CXM/DXM. INSTRUCTIONS for 1: boilerless - use wire diagram 96B0006N39 Connect the harness to DXM-P6 (lower right corner). Note- For MPC controller- the heater relay uses the same DXM output (EH) as pulsing fault code. This feature will not be available and pulsing fault code can only be viewed at the DXM. Locate the relay within the reach of the harness wires, mark and drill two 7/64 (2.8 mm) diameter holes. Securely attach relay with two #6 screws. Connect one black and the white harness wire to each side of relay coil. Securely tape off the 2 unused harness wire terminals (red and 1 black) to prevent electrical short. Connect supplied red wire from relay - COM and to any R connection on DXM. Connect supplied white wire from relay - N.O. to AH heater W1 Connect supplied brown wire from DXM-C to AH heater-c Connect supplied yellow wire from DXM-R to AH heater - R Remove DXM - G wire (disconnect on both ends). Connect supplied Black wire from AH heater GT to controller G output. Connect supplied gray wire from DXM-G to AH heater GU Configuring the DXM; Set dip switch S1.7 to enable (off). Set S1.8 to desired changeover 40F (off) or 50F (on). Set S1.6 and configure JW4 for your controller (see table 1). Blue wire is not used. Table 1 DXM Controller Dip Switch Clip Jumper S1.6 S1.7 JW4 Thermostat On Off No MPC Off Off Yes LON Off Off Yes 2 ClimateMaster Water-Source Heat Pumps

THE SMART SOLUTION FOR ENERGY EFFICIENCY General Information INSTRUCTIONS for 2: supplemental electric heat when using MPC. Use wire diagram 96B0006N82 Connect the harness to CXM/DXM-P6 (lower right corner). Note- For MPC controller- the heater relay uses the same CXM/DXM output (EH) as pulsing fault code. This feature will not be available and pulsing fault code can only be viewed at the CXM/DXM. Remove CXM/DXM G wire (disconnect on both ends). Connect supplied Black wire from AH heater GT to controller G output. Connect supplied gray wire from CXM/DXM-G to AH heater GU. For DXM- Set dip switch S1.6 to normal (on) and JW4 must be clipped. For CXM- Set dip switch 4 to normal (on) and JW1 must be clipped. Locate the relay within the reach of the harness wires, mark and drill two 7/64 (2.8 mm) diameter holes. Securely attach relay with two #6 screws. Connect one black and the white harness wire to each side of relay coil. Securely tape off the 2 unused harness wire terminals (red and 1 black) to prevent electrical short. Connect supplied blue wire from MPC-W to CXM/ DXM-W. Connect supplied red wire from relay- COM and to any R connection on CXM/DXM. Connect supplied white wire from relay- N.O. to AH heater W1. Connect supplied brown wire from CXM/DXM-C to AH heater- C. Connect supplied yellow wire from CXM/DXM-R to AH heater- R climatemaster.com 3

CLIMATEMASTER WATER-SOURCE HEAT PUMPS Typical Wiring Diagram 4 ClimateMaster Water-Source Heat Pumps

THE SMART SOLUTION FOR ENERGY EFFICIENCY Typical Wiring Diagram climatemaster.com 5

CLIMATEMASTER WATER-SOURCE HEAT PUMPS Notes: 6 ClimateMaster Water-Source Heat Pumps

THE SMART SOLUTION FOR ENERGY EFFICIENCY Notes: climatemaster.com 7

CLIMATEMASTER WATER-SOURCE HEAT PUMPS Revision History Date: Item: Action: 01/30/17 Page 5 Relaced wiring diagram 07/14/16 Logo Updated 04/15/16 Revised 08/22/12 First Published *97B0012N07* 97B0012N07 7300 S.W. 44th Street Oklahoma City, OK 73179 Phone: 405-745-6000 Fax: 405-745-6058 climatemaster.com ClimateMaster works continually to improve its products. As a result, the design and specifi cations of each product at the time for order may be changed without notice and may not be as described herein. Please contact ClimateMaster s Customer Service Department at 1-405-745-6000 for specifi c information on the current design and specifi cations. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster s opinion or commendation of its products. ClimateMaster, Inc. 2012 8 ClimateMaster Water-Source Heat Pumps