DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

Similar documents
DC1192 Input /Output module

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

DT1101A / DT1102A / DO110xA Automatic fire detectors

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

OH720, OP720, HI720, HI722

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

FDCL221-M Multi line separator module

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

FDCIO223 (ES 45) Transponder

DM1131 / DM1133 / DM1134 Manual call points

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

OOH740, OOHC740 Automatic fire detectors

DF1101-Ex Infrared flame detector

DOW1171 / DCW1151 Radio fire detection system

Input module, input/output modules

FDBZ290 Air sampling smoke detection kit

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

Input module, input/output module

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

FDBZ290 Air sampling smoke detection kit

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FDOOT241-9, FDOOT241-A, FDO241, FDT241

Multi line separator module

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

Synova TM product catalog.

Output module (230 V)

FDCW241 Radio gateway Mounting

FC723 Fire control panel

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

ASA linear smoke detector

DF1151-Ex Infrared flame detector

FC724 Fire control panel

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

FDCL221 Line separator

FDOOT221, FDO221, FDT221

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

FC724 Fire control panel

FC722 Fire control panel

FDM273 Radio manual call point Mounting

FDCL221-Ex Line adapter (Ex)

Fire control panels FC726 FC726-XA

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

FDL241-9 Linear smoke detector Mounting Commissioning

For internal use only. Distribution (please mark): Product Solution Multi-channel x

Radio fire detection system

SWING radio fire detection system

XC10 Extinguishing control panels

Fire control panels FC360

FC2020 Fire control panel

Room thermostat with 24-hour time switch and large LCD

FC722 Fire control panel

Room Temperature Sensors

Interbases. Sinteso FDSB221, FDSB228, FDSB229

FT2080 Fire terminal (Touch) Mounting Installation

FT2080 Fire terminal (Touch) Mounting Installation

OOH740-A9-Ex Multisensor fire detector

OOH740-A9-Ex Multi-sensor fire detector

FC700A Fire detection control unit

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

FDOOT241-A9-Ex Multisensor fire detector

FDS229 Alarm sounder with supplementary optical indication Technical Manual

FDA241, FDA221 Siemens ASD

FDA241, FDA221 Siemens ASD

Mimic display driver, LED ribbon cable

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

OH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual

Frost Units for air temperature monitoring

Frost Protection Thermostat

Electronic timeswitch

FS20 Fire detection system

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Duct Temperature Sensors

FC2040. Fire control panel. Sinteso. FS20 series, MP6

FP120-Z1 Power supply kit A (70 W) Technical Manual

Room Temperature Controllers

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Room thermostats with LCD RDD100..

Fire control panel for modernization

FDCI221, FDCIO221 Input module, input/output module Technical Manual

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Fire & Security Products. Siemens Building Technologies Group

OH110, OP110, HI110 Automatic fire detectors

Building Technologies. FDUL221 en Line tester operating instructions for electricians

Application Sheet Chilled/heated ceiling (4 pipe) with 6-way valve on analog output

Application Sheet Fan coil unit with staged fan, heating and cooling coil (4 pipe) on triac output including lighting and blinds operation

Room Temperature Controller

FDBZ290 Air sampling smoke detection kit Technical Manual

Sinteso TM product catalog.

Test units and accessories

Install intelligent room automation flexibly and future-proofed

Flush-mounted room thermostat

Application Sheet Fan coil unit with staged fan, 6-way heating/cooling coil (4 pipe) on analog output

MK8000 OPC Server Interface Specification for CS1115 Building Technologies

Building Technologies

Transcription:

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories interactive, AnalogPLUS/SynoLOOP, collective/synoline600 AlgoRex Synova TM Base made of impact and scratch-proof plastic Screw less terminals Completely covered by detector Integral rubber gasket to protect against draught, dirt and water from above Detector protected against vibration For mounting on recess box direct Range of accessories for surface wiring, installation in damp environment, protection against theft, inscription, etc. Models for interactive, AnalogPLUS/SynoLOOP und collective/synoline600 fire detectors

Characteristics Environmental halogen-free plastic material identifiable through embossed code easy to uninstall and disassemble Characteristics integral rubber gasket to protect against draught, dirt and dripping water from above screw less terminals place for auxiliary terminals, for the connection of 2 alarm indicators, cable screening or the connection of a detector heating unit Detector base DB110xA for collective/synoline600 fire detectors holder for connection terminals are 'white', wire cross section 0.2 2.5 mm 2 DB1131A for AnalogPLUS fire detectors holder for connection terminals are 'green', wire cross section 0.2 2.5 mm 2 SO620A for Synova 600 fire detectors holder for connection terminals are 'green', wire cross section 0.2 2.5 mm 2 DB1151A for interactive fire detectors holder for connection terminals are 'orange', wire cross section 0.2 2.5 mm 2 This base contains an identification module with factory-programmed number to store the location. When exchanging the detector, thanks to this module, the new detector is automatically correctly programmed. DB110xA rubber gasket DB1131A/SO620A screw less connection terminals DB1151A Identification module Ø 115 Detector base height = 21 mm Height with inserted detector: DO = 51 mm DOT = 63 mm DT = 54.5 mm OP = 50 mm OH = 62 mm HI = 53.5 mm 2

Micro terminals, Auxiliary terminals DBZ1190-AA for conductors of max. 0.5 mm 2 DBZ1190-AB for conductors of max. 2.5 mm 2 for the connection of 2 alarm indicators or cable screening Designation plate, Detector marking DBZ1190-AB DBZ1190-AA DBZ1193A to identify the location address DBZ1193A-AA to indicate location of detector with separator DBZ1193A DBZ1193A-AA Detector heating DBZ1190A-AC not permissible for explosion hazard application for the operation of the fire detectors in critical environments, danger of frost formation or moisture condensation, e.g. in cold storage houses, attics, loading ramps, cheese storage cellars, etc. optimum function of the detector heating is only ensured with the base attachment DBZ1191 or DBZ1192 the temperature of the detector is increased by approx. 2 in relation to the ambient temperature, so that moisture condensation is prevented it is clipped in the base DBZ1192 or DBZ1191 DBZ1190A-AC 3

Detector locking device DBZ1190 to protect the detector against theft DBZ1190 Base attachment DBZ1191 for feeding in surface wiring and to provide more wire loop space base is mounted using a spring-loaded catch Ø 116 Detector base height = 22 mm Height with inserted detector: DO = 72 mm DOT = 84 mm DT = 75.5 mm OP = 71 mm OH = 83 mm HI = 74.5 mm Base attachment flat DBZ1191A-AA for surface-mounted applications with cables up to Ø6 mm and to use existing mounting holes of MS7/MS9 bases base is mounted using a spring-loaded catch Ø 116 Detector base height = 11 mm Height with inserted detector: DO = 61 mm DOT = 73 mm DT = 64.5 mm Height with inserted detector: OP = 60 mm OH = 72 mm HI = 63.5 mm 4

Base attachment damp DBZ1192 for installation in damp environments when the detector heating unit is used base is mounted using a spring-loaded catch 135 135 Detector base height = 58 mm Height with inserted detector: DO = 107.5 mm DOT = 119.5 mm DT = 111 mm Height with inserted detector: OP = 106.5 mm OH = 118.5 mm HI = 110 mm Base attachment wet DBZ1192-AA with cover for installation in wet environments for DT/HI heat detectors only base is mounted using a spring-loaded catch 135 135 Detector base height = 92 mm Height with inserted detector: DT = 111 mm Height with inserted detector: HI = 110 mm 5

Protective cage DBZ1194 for the protection of the detector against damage can only be used together with the base attachment damp DBZ1192 158,5 Detector base height with inserted protective cage = 145 mm 6

Technical data Detector base Conductor cross section Terminals in the base 0.2 2.5 mm 2 Connecting terminals 1 2.5 mm 2 Micro terminals 0.28 0.5 mm 2 Operating temperature Storage temperature according to data sheet detectors Humidity Protection category EN60529 / IEC529 with detector with base attachment DBZ1192-AA and DT/HI IP44 IP55 Color white, ~RAL 9010 Detector heating Operating voltage (normal operation) 20 30 VDC DBZ1190-AC Operating current 35 55 ma Power typ. 1.2 W Resistor 580 Ω ±5 % Operating temperature -30 +40 C Humidity 95 % rel. 7

Details for ordering Type Part no Designation Weight Base DB1101A BPZ:4863650001 Detector base collective/synoline600 0.053 kg DB1102A BPZ:5348510001 Detector base collective (special UK) 0.062 kg DB1131A BPZ:4789750001 Detector base AnalogPLUS 0.060 kg SO620A BPZ:4860800001 Detector base SynoLOOP 0.060 kg DB1151A BPZ:4863780001 Detector base interactive 0.061 kg Accessories DBZ1190-AA BPZ:4677080001 Micro terminal 0.28 0.5 mm 2 0.001 kg DBZ1190-AB BPZ:4942340001 Connecting terminal 1 2.5 mm 2 0.007 kg DBZ1193A BPZ:4864330001 Designation plate (10 pcs) 0.086 kg DBZ1193A-AA BPZ:5009820001 Detector marking (10 pcs) 0.016 kg DBZ1190A-AC BPZ:5167850001 Detector heating incl. micro terminals DBZ1190-AA 0.035 kg DBZ1190 BPZ:4585260001 Detector locking device 0.008 kg DBZ1191 BPZ:4540830001 Base attachment for surface 0.040 kg DBZ1191A-AA BPZ:5011270001 Base attachment flat for surface 0.022 kg DBZ1192 BPZ:4588140001 Base attachment damp 0.265 kg DBZ1192-AA BPZ:5355590001 Base attachment wet 0.449 kg DBZ1194 BPZ:4677110001 Protective cage 0.133 kg Siemens Switzerland Ltd Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41 724 24 24 Fax +41 41 724 35 22 www.siemens.com/buildingtechnologies 2009 Copyright by Siemens Switzerland Ltd Data and design subject to change without notice. Supply subject to availability. Document no. 001035_j_en_-- Manual S11 / FD-C Edition 01.2009 Section 4 / 3,4,5