Sensor Evaluation for Human Presence Detection

Similar documents
Temperature Data Logging

Weigh In Motion (WIM) Wheel Impact Load Detector (WILD)

ADVANCED MONITORING AND DIAGNOSTIC SYSTEMS FOR INDUSTRIAL GAS TURBINES

Occupancy Sensor Operation with Lighting Fixtures

English. Italiano. Português. Françias. Español

Sentry G3 Machinery Protection Monitor

Sentry G3 Machinery Protection Monitor

Installation Instructions Azatrax Dual Infrared Model Train Detector MRD2 'Turnout' Edition

l High precision, computer-designed parabolic optical system,. Dual element pyro-electric sensor.

A660 Air Conditioning Laboratory Unit

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

When did this technology start?

G.M. Advanced Fencing & Security Technologies Ltd

Appendix A Equipment Used to Monitor Hotels

Across-the-Line SERIES MP300 Combined Manual and Automatic

NX-10 wireless keypad. To wire or not to wire?

G-MAX IVS R123 Vibration Sensors Perimeter Intrusion Detection System

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

LUX Hardwired - Installation Notes

PULSE OXIMETER PACKAGE

Installation Instructions Azatrax HexDetex Model Train Detector with Grade Crossing Trigger MRD6X

Engineering Specification

Soft Start Series MP700 Solid State, Reduced Voltage

ENSC 388: Engineering Thermodynamics and Heat Transfer

ALARM SECURITY PRODUCTS

D-Tect 2 GJD300 Quad PIR Movement Detector

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

Committed to security

FlameGard 5 UV/IR HART

Low-Cost, Non-Invasive, Microwave-Based Bulk Solids Flow Detector

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

Third-Party Research & Development Technical Discourse. Application of cirqed RA for FFT Analysis Part I Identifying Real And Aliased FFT Components

KwêBeams Effective wire free outdoor early warning system

A New Standard of Excellence

Portable Perimeter Detection and Monitoring System - PoPDaMS

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

Security Escort. boschsecurity.com. Reliable wireless location solutions

Microwave Sensors for Industrial Applications

Improved Dryer Control

EA-430 USER MANUAL. Version

Commercial Series TriTech Motion Detector. Reference Guide

How to use the BTRM in Remote Enclosures

CAN unit for Analog Sensors

Open Source Home Security System

ALARM MATE NEWSLETTER SEPTEMBER 2013

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

FlameGard 5 MSIR HART

D-TECT Dual Tech. GJD360 Triple Technology External Detector

Technical specifications of FT-IR Spectrometer

Typical applications include the vibration detector. Detection of vibrations and shocks

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

BUILDING MANAGEMENT SYSTEMS. Introduction to Building Management Systems

PRODUCT TRAINING MODULE: Honeywell Zephyr Airflow Sensors HAF Series High Accuracy

Home Automation. Product info. Marketed By: BlueSilica Technologies For further details write to

Sierra Series 900 Single & Dual Channel System. Instruction Manual

VESICA LINEAR SUSPENDED VES L

REMOTE CONTROL AND MONITORING OF LANDMINES DETECTION ROBOTIC SYSTEM

Sitron s CF Line of Flow Switch Monitors

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

Smart Starter Bundle. Hub. Smart Motion Sensor. Smart Door/ Window Sensor

1.1. SYSTEM MODELING

Substation Monitoring System

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

Technical Description

WeatherLink for Alarm Output Addendum

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

SAFEMASTER PRO. The configurable safety system versatile and extendable. Our experience. Your safety.

PIR Occupancy & Motion Sensor

The Genesis. Wireless PIR System. Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n. BS8418 Compliant

Frequently asked questions: Intelligent Transmitter Series

DESIGN PHILOSOPHY FOR FIRE ALARM & DETECTION SYSTEM

D-TECT 3 IP. GJD260 IP Motion Detector

User Detection Sensors

Mechanical Heat Pump R515

SMARTWALK DEMENTIA WANDERING SYSTEM

Analyze IT. Process Gas Chromatograph. PGC2000 Series

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

DS160/DS161 Request To Exit PIR sensors Installation Instructions

Variable Frequency Drive SERIES MP800 VFD

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

USER S GUIDE. AXIS Cross Line Detection

engineered for a higher return

ProStar 325 UV-Vis Detector

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD

Fiber Optic Cable Fence Disturbance Sensor

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Instructions for TA HR 2 Shear Rheometer 6 November 2013

Sensing the World. When you have finished this lecture you should be able to:

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

Integrated Security Solutions

Honeywell SLATE ICM Platform

PARTICULATE EMISSION MONITORING

Specification for On-Line UPS Battery Monitoring and Data Management System

Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications

Transcription:

Sensor Evaluation for Human Presence Detection John Shutske, Associate Professor Bill Gilbert, Assistant Scientist Jonathan Chaplin, Associate Professor Paul Gunderson, Director, National Farm Medicine Center, Marshfield, WI Background This part of the project focused on the development of a sensor system to detect the presence of a person near a dangerous machine component. If this system proves reliable, it could be used with devices such as magnetic clutch/brakes to rapidly arrest the motion of the equipment. Some tractors are now availiable with electrohydraulic PTO control, which could include a sensor system such as this one in a chain of safety shutoff interlocks. Beginning in late 1994, project staff including faculty and students conducted a review of various sensor categories for the purpose of detecting people approaching a hazard area. The data suggested that the overlapping use of passive infrared and microwave sensors might have potential value for use on agricultural equipment. Since there are many off-the-shelf motion sensors already availiable to the building security industry, it made sense to start by evaluating them on equipment operating in staionary mode. A large number of injuries occur on power equipment such as silage elevators, and field equipment parked for unclogging, and could be prevented using these inexpensive sensor technologies. The Test System: Block diagram of test data acquisition system. During the winter of 1996-97 a data acquisition system was developed and assembled to test sensors mounted on a tractor, generating performance data which can be analysed statistically and examined for correlations to test conditions. For each set of conditions, two modes of testing were employed. Sensors were first tested both for the speed and reliability with which they detected a human moving into the protected area, and second, for susceptibility to false alarms.

The system allows for the use of multiple sensors simultaneously, and repetitive passes are used to generate statistical data on reliability. Using Boolean logic, it is possible to test various combinations of sensor outputs for effectiveness in minimizing false alarms (i.e. two or more sensors must go into an alarm condition before the overall multi-sensor system goes into an alarm condition). The heart of the the test system consists of an IBM ThinkPad 486-100 laptop computer and an IOtech DaqBook100 data acquisition board connected to the parallel printer port. Test programs (Virtual Instruments) written using National Instruments LabVIEW communicate with the DaqBook, providing the operator interface panel and data storage to delimited text files. Solid state relays were used to protect the CMOS TTL discrete I/O ports of the DaqBook. Approach velocity and position of the human test subject were monitored using a PSI-TRONIX DVT-500 linear motion transducer. The system was powered by a pair of 12 volt lead/acid gel cell batteries and mounted on an IH 986 tractor. Sensors were mounted on a rail along the rear of the tractor aimed toward areas that a person would cross through if approaching a rotating PTO shaft attached to an implement. To allow fast and easy changes in positioning and aiming, the rail is drilled on two inch centers and sensors are mounted using ballheads designed for use on camera tripods. Sensor mounting rail on rear of tractor. Sensors mounted using ballheads designed for use on camera tripods. In the tests reported in this paper, a Gehl self-unloading forage wagon was used as the PTO driven stationary implement. The zone to be protected included an envelope extending from the outer surfaces of the tractor's rear wheels extending from the rear surface of the tractor to the front face of the wagon. Figure below shows this configuration.

Diagram showing protected zone between tractor and wagon. Operation: As test subjects approached the potential hazard area, their velocity and position were recorded using a 500 inch linear motion transducer. This device consisted of a cable (attached to the person's belt) reeled from a spring-loaded drum coupled to a potentiometer and a DC generator, providing voltage outputs as a function of position and instantaneous velocity. Resolution of this system was limited by the analog input capabilities of the DAQBOOK to +/- 0.25 inches for position and +/- 0.1 inches per second for velocity. Test subject Ryan entering hazard area while trailing measurement cable(not visible) from position/velocity transducer at lower left Ryan approaching hazard area. 500 inch position/velocity transducer showing spring tensioned cable.

Jon operating data acquisition system A sample output screen from the data acquisition and control system is shown below. A "pass" was defined as a single approach toward the hazard area on a pre-defined straight-line path. Multiple "runs" were performed, each consisting of 30-50 passes which shared a given set of conditions. For each separate run, test conditions were logged in notebooks. These included sensor position, approach angle of the person with respect to the hazard, temperature, sunlight condition, ground surface qualities, and other important environmental parameters. Ten times per second, from the start of the pass until one second after detection, the software sampled the sensor status, the velocity and position of the test subject relative to the hazard, and warning time. The warning time was calculated by dividing the distance remaining between the approaching person and the hazard at the time of detection by their maximum velocity during the one-second preceding detection. This calculated time is important since it provides an indication of the amount of time available to respond to the signal (such as shut down or warning) before the human reaches the hazard. For each pass, at the moment of detection, the system latched the readings and logged them to a file which summarized the results of the entire test run. In addition, the system logged time-stamped raw data for all passes to a separate file for detailed examination if needed. Sample display screen.

Results The first round of testing completed during summer 1997 focused using three different sensors individually to examine performance of sensors independently of one another. Passive infra-red(pir) with a relatively narrow cone-shaped zone of protection Combination Doppler shift microwave and passive infra-red(mw/pir) Combination Doppler shift and reflected power microwave(mw/pres) A total of 822 subject approach passes were completed. With each sensor, test subjects approached at differing angles including perpendicular to power take-off shaft and at angles +/- 40 degrees from perpendicular. These three approach angles were repeated for two clothing styles including typical summer and winter wear. In these 822 passes, there were no sensor "misses." No false alarms occurred during the subject approach test passes. Relatively few alarm events were generated during tests for false trigger susceptibility. As long as the tractor was not rolling over the ground, all three sensors were surprisingly immune to engine vibration, operator activity, PTO shaft rotation, and objects tossed through the protected area. Clothing had little effect on sensor performance as can be seen in summary Table 2 which shows the distance from the hazard at the time of detection for varying clothing styles and angles for each of the three sensors tested. Note however, that the angle of approach has an impact on detector performance, probably due to differences in sensor field geometry. Table 2 Inches from Hazard Clothing Style Light Light Light Heavy Heavy Heavy Approach Angle -50-90 -130-50 -90-130 Average By Sensor across angles & clothing types PIR 41.6 30.1 32.5 39.8 35.2 29.6 34.8 MW/PIR 45.2 33.2 26.9 43.0 35.6 28.8 35.4 MW/PRES 33.9 52.4 45.6 32.1 47.7 43.1 42.5 By angles&clothing across sensor types Readings for both clothing types averaged over 40.2 38.6 35.0 38.3 39.5 33.9 37.9 37.2

sensors&angles Additional tests were performed in 1997 on configurations of multiple sensors in which various sensor outputs were logically ANDed, requiring all to trigger to generate an alarm event. In these modes the system performs very well, but detection performance is limited by the slowest acting sensor. It appears that when performance tests are conducted in ideal conditions such as those reported here, the added redundancy of multiple sensors might not be necessary to reduce false alarms. Ongoing work: The system has been modified to allow relative timing, in addition to boolean combination, of the sensor outputs to be used as alarm criteria. More aggressive testing for false alarms is planned. Additional narrow field PIR and MW/PRES sensors have been acquired and are being tested. The most promising configurations use a wide field MW/PRES sensor on the tractor centerline with a a narrow field PIR or MW/PRES sensor on either side. Summary and Recommendations This work represents an important first step toward the development of a human presence sensing system that may have potential for field applications. The two sensing technologies tested together provide the overlap necessary to significantly reduce false alarms and misses in agricultural work environments. However, additional research is needed to further develop and refine individual sensing components and housings to assure that they will withstand the environmental conditions and use that they would receive over the life of a typical machine. Hopefully, additional work can be completed during the coming years in cooperation with universities, equipment manufacturers, and various public institutions and funding agencies with interests in helping producers protect themselves from the dangers of rotating equipment. Funded in part through Midwest Center for Agricultural Research, Education, and Disease and Injury Prevention: A NIOSH/CDC Cooperative Agreement Program, #U07/CCU507126-07. Thanks also to The National Farm Medicine Center, a department of Marshfield Medical Research and Education Foundation, a division of Marshfield Clinic in Marshfield, Wisconsin for their interest and support of this project. Last updated March 31, 1998 1997 Regents of the University of Minnesota. All Rights Reserved.