Superior by Design The Kidde ADS TM FM-200 System

Similar documents
FIRE SUPPRESSION SYSTEM

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

How can I protect invaluable assets and the environment from the effects of a fire?

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

SPECIFICATION: ARGONITE Engineered Fire Suppression System

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

Fire suppression systems for server rooms and data centres

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

CO2 COCO GAS FLOODING SYSTEM

CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML

KITCHENShield WCK Kitchen Fire Suppression System. Advanced fire protection systems

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

KD Innovative extinguishing with Novec TM 1230 by 3M TM

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

MISSION CRITICAL FIRE PROTECTION

MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems

Data/ Specification Sheet

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

An Overview of Extinguishing Systems for Computer Equipment

Carbon Dioxide Fire Suppression Systems

DETECT-A-FIRE Heat Detectors

HFC-227ea FIRE SUPPRESSION SYSTEM

automatic FiReFighTing SYSTeMS in PainT booths

How can you minimize consequential damages in case of a fire?

FM-200 In-Cabinet Series

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

SUPPRESSION SALES I INSTALLATION I SERVICE

Water Mist Fire Suppression

FIRE PROTECTION TECHNOLOGY Solutions never thought of before

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

GX-20/FM-200 Fire Extinguishing System

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

MINIMAX FIRE PRODUCTS WHITE PAPER THE COST-BENEFIT ADVANTAGES OF REPLACING HALON WITH 725 PSI MX 1230 CLEAN AGENT FIRE SUPPRESSION SYSTEMS

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems

PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards:

FIRE PROTECTION SYSTEM FOR INDUSTRIAL KITCHENS

THE WORLD LEADER. in special hazard fire suppression solutions

DuPont FE-25 FIRE EXTINGUISHANT. Preferred Replacement for Existing Systems and the Choice for New Applications

AFEX. fire suppression systems AFEXSYSTEMS.COM

SECTION FM-200 FIRE SUPPRESSION SYSTEM

FIRE AND FIRE FITTING By Mr. Prashant Sansare

THE IDEAL SOLUTION FOR KITCHENS

AUTOMATIC FIREFIGHTING SYSTEMS IN KITCHENS

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

Fire Prevention Plan

Three elements of fire. Heat Oxygen Fuel. Remove one of the three and the fire is extinguished.

OWNER'S OPERATION AND MAINTENANCE MANUAL

Fixed Fire Extinguishing Equipment and Systems

BOC FS125 The Fire Extinguishing Solution

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

Amerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.

AUTOMATIC FIREFIGHTING SYSTEMS IN HOSPITALS

Identify RISKS. Design SOLUTIONS. Prevent DISASTERS

SECURITY BLANKET Foam Fire Protection Products

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

Safe, Effective, Environment-friendly

FIRE PROTECTION, NATURALLY AQUASONIC Water-Atomizing Fire Suppression System

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

SAFETY THE BEST FOR YOUR EQUIPMENT

CO 2 EXTINGUISHING SYSTEMS

Sinorix Silent Extinguishing Technology protecting the quiet way

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

WATER MIST CONVENTION AND EXHIBITION

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

Using Fire Extinguishers. Leaders Guide and Quiz

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

Risk Management Department. Fire Extinguishers

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea

"USING FIRE EXTINGUISHERS"

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI

ANSUL TO-ANSUL. For more information... Check your local Yellow Pages for your authorized Ansul Restaurant Systems Distributor.

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

Protecting Critical Facilities Against Explosions

Portable Fire Extinguishers

KIDDE WHDR WET CHEMICAL FIRE SUPPRESSION AND INTELLIGENT CONTROL SYSTEM FOR COOKING OPERATIONS WITH ARIES-NET MULTI-LOOP INTELLIGENT CONTROL UNIT

Fire Prevention Plan

SUPERIOR THINKING. DEEPER DIGGING. Underground Mining Fire Suppression Systems

TAMUCC Fire Safety Training

Fire Suppression Systems. Heavy Duty Mobile Plant Protecting Your Business. Head Office: 14 Baynes Place, Chelmsford, Essex, CM1 2QX

Fire Extinguisher Training

FIRE SUPPRESSION SOLUTIONS

WSU-TFREC Fire Safety Training

Protecting your most valuable assets

A Guide for Meeting NFPA 10 Subsection

STAT X - SPECIAL HAZARD FIRE PROTECTION

Protecting Facilities Against Explosions. Since 1956

SERVICE VERSUS REMOVAL OF OBSOLETE COMMERCIAL KITCHEN PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

Welcome to Argonite fire protection from Ginge-Kerr

Protezione antincendio di dati e business critical assets nei Data Centers

What extinguishes fires without pressure peaks?

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

Transcription:

A UTC Fire & Security Company Superior by Design The Kidde ADS TM FM-200 System Engineered to Provide Exceptional Performance The Kidde ADS FM-200 System is an innovative system developed by Kidde engineers to provide economic protection for larger enclosures requiring longer agent flow distances, and as a drop-in replacement for Halon. With the patented-technology of piston flow, the Kidde ADS FM-200 System is capable of delivering greater mass flow rates (2.5 to 3 times faster) than those achievable with a standard FM-200 system. This innovation allows networking of longer pipe runs in complex configurations with smaller pipe sizes for protection of larger hazard areas. These characteristics allow the ADS System to be a virtual drop-in replacement for existing Halon systems. Most installations will require only new nozzles and agent storage cylinders and can use most of the existing pipework which provides substantial savings when retrofitting existing systems. Kidde ADS System Features: Virtual drop-in replacement for existing Halon installations. Uses existing piping, changes limited to replacement of agent storage cylinders and nozzles Increased agent flow rates and distances provide better coverage for larger hazard areas Smaller piping diameter results in installation cost savings Ultimate design flexibility provides the most economical protection for many applications Kidde Fire Systems We Are the Right Protection... Every Time, Everywhere, Every Application. UL Listed, EPA Listed FM Approved and USCG Approved

Why Choose a Kidde ADS Series FM-200 System? Rapid-Response. In seconds not minutes, the ADS System discharges FM-200 suppressant into the hazard area providing the fastest fire protection available. This results in less damage, fewer repair costs and reduced downtime. Damage-Free. Removed from the hazard area by ventilation, FM-200 allows virtually immediate return to business as usual without the interruption of a costly clean-up and the expense of damage to assets from suppressant residue. People-Safe. The most comprehensive toxicology data of any clean agent available affirms FM-200 is non-toxic when used in compliance with NFPA Standard 2001. FM-200 does not impair breathing or obscure vision in an emergency situation providing an added measure of safety for personnel. Evironmentally-Conscientious. With a zero Ozone Depletion Potential, a low atmospheric lifetime, and its speedy suppression performance FM-200 not only offers low environmental impact but reduces the potentially devastating atmospheric pollutants of an uncontrolled fire. Laboratory-Tested. FM-200 has been tested and found to be effective on the widest possible range of Class A (wood, paper and cloth), Class B (flammable liquids) and Class C (electrical) fuels. Globally-Accepted. Used in more than 70 countries around the world, FM-200 meets the standards of Underwriters Laboratories, Factory Mutual, the National Fire Protection Association (2001 Standard), the U.S. EPA SNAP program and most global approval authorities. Kidde-Approved. That means Kidde, a world leader in clean agent protection, stands behind FM-200 fire suppression performance and reliability. Typical Applications The Kidde ADS Series FM-200 System is an advanced system innovation developed by Kidde engineers to provide economic protection for larger enclosures requiring longer agent flow distances. ADS Series FM-200 System Replacement of Existing Halon 1301 Systems Telecommunications Facilities Internet Hosting Sites Health Care Facilities Recording Studios Multi-Level Sites Larger Manufacturing Complexes A UTC Fire & Security Company 400 Main Street Ashland, MA 01721 Tel.: 508.881.2000 Fax: 508.881.8920 www.kiddefiresystems.com Kidde and ADS are registered trademarks of Kidde-Fenwal, Inc. FM-200 is a registered trademark of Great Lakes Chemical Corp. SS K-007 January 2007 Kidde-Fenwal, Inc. All Rights Reserved.

Protecting Your Assets Today; Protecting Our Environment Tomorrow Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection Fluid At Kidde, we are committed to providing more than fire protection we strive to deliver value. This guiding principle was paramount in the development of the Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection Fluid. Kidde engineers set out to manufacture a suppression system flexible enough to satisfy the requirements of a wide range of special hazard applications while meeting the environmental standards of today, as well as those of the foreseeable future. Novec 1230 fluid is the ideal suppressant for the system as it provides the greatest margin of safety of any clean agent replacement. In addition, it is the first clean agent to offer a viable, long-term solution to the environmental challenges presented in today s environmentally aware society. Novec 1230 Fire Protection Fluid Features: Zero Ozone Depleting Potential Global Warming Potential (GWP) of just one 99.9% lower than any other halocarbon agent acceptable for use in occupied spaces Atmospheric Lifetime of just five days the closest alternative is 33 years Safety Margin of 100% higher than any other type of clean agent fire suppressant Easy to handle and charge stored as a liquid (at room temperature) so cylinders are not pressurized Kidde Fire Systems Setting the Standard in Fire Protection UL Listed, FM Approved and USCG Approved

Why Choose a Kidde Engineered System using Novec 1230 Fluid? Environment Friendly. Novec 1230 fluid has a zero Ozone Depletion Potential, a Global Warming Potential of just one, and an atmospheric lifetime of only five days. Safe. Independent scientific studies have proven that Novec 1230 fluid poses no safety risk to people in occupied spaces at the normal design concentration. It also offers a safety margin of up to 100% that s higher than any other type of clean fire suppression agent. Efficient. Novec 1230 fluid puts fires out quickly, before they can do any serious damage. It does this by reaching extinguishing concentrations in ten seconds or less. Because Novec 1230 fluid extinguishes fires with a combination of heat absorption and chemical interface with the flame, it is effective on a wide range of Class A, B and electrical fires. Clean. Novec 1230 fluid, stored as a liquid, discharges as a colorless, electrically non-conductive, and non-corrosive gas. It does not leave any residue behind, and there is no need for costly clean-up operations. Cost-Effective. Kidde has produced a cost-effective Novec 1230 fluid Fire Suppression System with independent third party approvals recognized worldwide. Novec 1230 Fluid System Typical Applications: Petrochemical Installations Steam Turbine Generators Telecommunications Marine Applications Pharmaceutical/Healthcare Food Processing Facilities Railway Traffic Controls Electrical Equipment Power Generation Packaging Plants Universities/Collegiate Printing Facilities Science Labs 5 6 4 2 3 System Components: 1 1. Novec 1230 Fluid Cylinders 2. ARIES Control Panel 3. Notification Device 4. Horn 5. Nozzles 6. Detection - Intelligent Kidde is a registered trademark of Kidde-Fenwal, Inc. 3M and Novec are trademarks of 3M. SS K-001 March 2007 Kidde-Fenwal, Inc. All Rights Reserved.

A UTC Fire & Security Company Kidde WHDR Wet Chemical Systems: 24 Hour Protection for Commercial Kitchens The heart and soul of every eating establishment is the kitchen. Equipped with ranges, broilers, fryers and a myriad of other high-temperature cooking appliances no other environment demands proper fire protection more than today s commercial kitchen. The Kidde WHDR System is designed specifically for commercial kitchen applications. By offering the most flexible system configurations in the industry, Kidde provides the most efficient protection for all cooking applications and facilities. You can specify the type of detection, control and cylinder size to fit your application. Investing in a Kidde WHDR System guarantees more than compliance with UL Standard 300, NFPA 96, NFPA 17A and insurance codes it provides protection from the devastating consequences of a fire. Kidde WHDR System The Kidde WHDR System: Economical cost-effective, code-compliant fire suppression Fast and easy maintenance semi-annual system inspections and routine maintenance per NFPA regulations are performed quickly and efficiently Reliable, proven protection the WHDR System is the choice of commercial kitchens, with thousands of installations worldwide Global network designed, manufactured and installed by factory-trained Kidde Distributors found around the world UL Listed and ULC Listed

How the System Works 1. Fire is detected activating the XV TM Control System (or the manual pull station is actuated)... causing the cylinder valve to open. 2. Pressure stored in the cylinder propels the wet chemical agent through the system piping and out of strategically located nozzles. The Kidde WHDR System automatically shuts down the power source to appliances removing the heat. 3. The wet chemical agent knocks down flames quickly and forms a protective layer that suppresses fire and prevents fire re-ignition. 1 2 2 2 1 2 1 3 3 3 2 How the Agent Works The Kidde WHDR system uses Kidde APC wet chemical agent, which extinguishes fire by: Saponifying the surface grease (converting it into combustion-resistant soap) The cooling effects of water vaporization Interrupting the chemical chain reaction of combustion Kidde APC wet chemical agent is proven to be the best suppressant for quick knock-down and prevention of re-ignition of flame. Secondary Defense Class K Extinguishers Portable fire extinguishers play an important role in early defense against fire. Class K-type suppressant is used to combat the especially difficult fuel hazard presented by extremely hot grease in cooking environments. Typical Appliances Protected: Ventilation Fryers Char-Broilers Ranges Woks Griddles A UTC Fire & Security Company 400 Main Street Ashland, MA 01721 Tel.: 508.881.2000 Fax: 508.881.8920 www.kiddefiresystems.com Kidde is a registered trademark of Kidde-Fenwal, Inc. WHDR and XV are trademarks of Kidde-Fenwal, Inc. SS K-008 September 2006 All Rights Reserved. Kidde-Fenwal, Inc.

Clean, Dependable Suppression: The Kidde Carbon Dioxide System Fast Fire Protection for Challenging Hazards Flammable materials and vapors present a significant risk of fire for many industrial processes and environments. The Kidde Carbon Dioxide Suppression System was designed to provide complete fire protection for a wide range of challenging applications from printing presses and generator enclosures to dip tanks and commercial fryers. Carbon Dioxide delivers clean, dependable suppression in seconds, greatly reducing the loss of assets, productivity and revenue associated with a fire-related business interruptions. The Kidde Carbon Dioxide System utilizes highly sophisticated electric and/or pneumatic detection units which sense fire at its inception immediately alerting the control system. The Control Panel initiates the release of Carbon Dioxide from the system cylinders. The suppressant is delivered through a fixed piping network with specially designed nozzles providing rapid, automatic fire protection around the clock. Kidde Carbon Dioxide System Features: Damage-Free Fire Suppression Reduces Loss Design Versatility with Three System Configurations: - Total Flooding - Local Application - Local Hose Line Rapid Response Discharges in Seconds No Residue Clean-Up Minimizes Downtime Surface or Deep-Seated Fires Kidde Fire Systems Setting the Standard in Fire Protection. UL Listed, FM Approved and USCG Approved

Why Choose a Kidde Carbon Dioxide System? Superior Suppression. Carbon Dioxide (CO2) is a colorless, odorless, electrically-nonconductive gas whose density is approximately 50% greater than air. A Kidde Carbon Dioxide System suppresses fire by providing a blanket of heavy gas that absorbs heat from the fire and reduces the oxygen content of the atmosphere to a point where combustion becomes impossible. Damage-Free. A naturally-occurring atmospheric element, Carbon Dioxide dissipates into the air allowing an almost immediate return to business as usual without the interruption of a costly clean-up and the expense of damage to assets from suppressant residue. This results in fewer repair costs and reduced downtime. Design Versatility. Because Carbon Dioxide is an ideal suppressant for a wide variety of industrial applications, Kidde offers three system configurations to efficiently protect different hazard types: Total Flooding ideal for enclosed hazard areas, Local Application used to protect a specified hazard area in an open floor plan, or a Local Hose Line cost effective protection for fighting smaller fires throughout a hazard. Kidde Quality. At Kidde, we know a fire-related business interruption can keep your company from being competitive in a global market. We are committed to researching, developing and providing the most advanced fire protection technology and best customer service in the industry. We understand the marketplace demands an up and running business world around the clock. We are dedicated to keeping industry in business by keeping fires out. Typical Applications The Kidde Carbon Dioxide System is ideal for industrial processes where flammable materials and vapors present a potential hazard. For this reason, it is essential to have sufficient fire protection on site: Flammable Liquid Storage Areas Marine Applications Quench and Dip Tanks Large Commercial Fryers Engine and Electrical Rooms Spray Booths and Paint Lockers Turbine Generators Printing Presses Rolling Mills Dust Collectors Industrial Ovens Mixing Operations Total Flooding CO2 System A Kidde Carbon Dioxide System designed specifically for the hazard and operated automatically, assures immediate detection and rapid suppression. Local Application CO2 System Kidde is a registered trademark of Kidde-Fenwal, Inc. SS K-011 September 2007 Kidde-Fenwal, Inc. All Rights Reserved.

Rugged Kidde IND Systems Are Recommended For All Types of Industrial Fire Protection... The Engineering Specification The fire suppression system for piping parameters and discharge (INSERT HAZARD AREA DESCRIP- nozzle types pre-determined by TION) shall be a Kidde Model IND the fire suppression manufacturer. Industrial Dry Chemical fire suppression system. The hardware used to accomplish the piping No hydraulic calculations shall be shall be manufactured by Kidde, design. The design application for 400 Main Street, Ashland, MA USA. this hazard shall be [CHOOSE ONE The dry chemical agent shall be (Total Flooding or Local [CHOOSE ONE (ABC, monoammonium phosphate or BC, sodium equipment shall be capable of a Application)]. The fire suppression bicarbonate)]. The dry chemical minimum storage temperature of agent shall be stored in steel cylinders meeting DOT requirements and installation shall be in accor- -40 F (-40 C). The design, piping and shall be painted red. The cylinders shall be of the stored pressure Industrial Dry Chemical Instruction dance with NFPA 17 and the Kidde type with a maximum pressure of Manual. Acceptance of the finished system shall be in accordance 360 psig @ 70 F. Cylinder valves must be equipped with a pressure with NFPA 17 and the Kidde gauge. The design concept shall be Instruction Manual. of the pre-engineered type with Our Quality is Certified Kidde IND Dry Chemical Fire Suppression Systems are made in America in accordance with ISO 9001 certified quality standards and installed and serviced by Kidde Distributors worldwide. When you ve specified Kidde, you ve chosen the world s most respected name in fire protection. Fire Systems Kidde IND Systems are Available From Processes Involving Flammable Liquids Quench Tanks Industrial/Automotive Paint Spray Booths Coating Operations Dip Tanks Electrical/Mechanical Rooms Boiler Rooms Switchgear Rooms Generator Rooms Furnace Rooms Flammable Liquid Storage Areas Flammable Liquid Storage Paint Mixing Areas Spill Containment Dikes Bulk Storage Specialty Hazards Modular HazMat Storage Facilities Exhaust Ducts Environmental Storage Facilities Machinery Spaces This literature is provided for informational purposes only. KIDDE assumes no responsibility for the product s suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE, Ashland, MA 01721: Tel: (508) 881-2000. Kidde IND Dry Chemical Fire Suppression Systems Maximum Fire-Killing Power for Industrial Applications KIDDE-FENWAL, INC. 400 Main Street, Ashland, MA 01721 (508) 881-2000 FAX: (508) 881-8920 FORM No. KF-0042 2001 Kidde-Fenwal, Inc. Printed in U.S.A.

KIDDE IND Dry Chemical Fire Suppression Systems... Automatic, 24-Hour Protection for Industrial Applications. Could you afford to have your production line shut down due to a fire? Is there room in your operating budget to replace machinery and facilities damaged by fire? If your company is typical of today s high-productivity, cost-conscious facilities, the answer is no, we can t have our operation interrupted by any type of fire. That s why a Kidde IND Dry Chemical System is your best choice for protection of any industrial process or machinery where flammable liquids or hazardous materials are involved. Versatile Fire Suppression Kidde IND Systems use either Class ABC or Class BC dry chemical to suppress fire. Pound for pound, dry chemical suppresses more fire than any other agent, providing both rapid suppression and protection against fire re-ignition. Our sodium bicarbonate-based dry chemical is more effective than water on Class B (flammable liquid) and Class C (electrical) fires. ABC dry chemical also suppresses Class A (wood, paper, cloth) fires. Both are environmentally safe, non-toxic and economical to use in both initial installations and recharge situations. No wonder dry chemical is preferred for more applications throughout industry than any other agent. Quick Response Minimizes Fire Damage Kidde IND Systems are designed to sense fires quickly, sound alarms to warn personnel in the area and discharge dry chemical on the source of the fire. All these actions occur in seconds, before the fire has the opportunity to grow in intensity or spread to other areas of the facility. For your peace of mind, Kidde IND Systems offer the surety of automatic fire protection whether or not personnel are present 24 hours a day. The Kidde Pre-Engineered Approach to Fire Protection. Precise. Effective. Affordable. Three Choices of Fire Detection Depending upon your hazard, one of three Kidde detection methods will best suit your needs. Mechanical detection uses fusible link detectors to provide reliable performance at low cost. Electric detection offers enhanced sensitivity and the design versatility of thermal, smoke or optical detectors for compatibility with just about any type of hazard environment. Pneumatic detection combines high sensitivity with no-spark operation necessary for explosion-sensitive applications or where electrical power for system operation is not available. Single or Multiple System Control If you have one hazard area to protect, the Kidde SCORPIO Control Panel gives you microprocessor-based reliability in a fully supervised suppression release and alarm output system. If you re controlling multiple Kidde fire alarm or suppression systems, the smart choice is the Kidde PEGAsys Control System, our latest detection technology that uses a distributed intelligence concept to of more detection and alarm capability, faster response time, more immunity to nuisance alarms and lower maintenance costs. The Right Cylinder Sizes Your Kidde Distributor can choose from three sizes of agent storage cylinders using ABC or BC dry chemical Kidde IND 21 (ABC)/25 (BC), Kidde IND 45 (ABC)/50 (BC) or Kidde 70 (ABC)/75 (BC) to design the precise system that best meets your fire protection requirements while conserving hardware and dry chemical agent cost. Superior Coverage Due to our advanced nozzle design, Kidde IND Systems cover more volume of hazard area with less dry chemical agent than any other brand of total flooding system. Dry chemical is discharged both radially and downward to maximize coverage. What this means is that we can protect your application using a minimum number of agent storage cylinders. Less hardware means a lower installed cost. Listed and Approved Kidde IND Systems, with ABC or BC dry chemical agents, are listed by Underwriters Laboratories, Inc., Underwriters Laboratories Canada and approved by Factory Mutual for operating in temperature ranges from -40 F to 120 F. Costs Less To Install and Maintain Proven Kidde Performance TOTAL CYLINDER COVERAGE Backed by more than 20 years of industrial experience, Kidde engineers have perfected a system to meet the needs of today s facility, plant and maintenance managers. We ve designed the Kidde IND System to be like your facility s environment, rugged and reliable, yet compact. Our pre-engineered concept saves you money in both hardware and installation costs, while offering precise protection for a wide variety of industrial fire hazards. Finally, the recharging of a Kidde IND System is fast and economical, a real bonus for anyone with an eye on their maintenance budget. Kidde IND Systems protect more industrial hazards in more types of plants worldwide than any other brand. So it stands to reason that we have a better understanding of how to specify the right system for your application, install it with a minimum amount of disruption to operations and keep your Kidde IND System in perfect working condition through our global network of Kidde Distributors. It s exactly the performance you d expect from the leader in fire protection. Local Application or Total Flooding Designs Kidde IND Systems are available in room and processes, rapidly floods two basic configurations. In a local the protected area with dry chemical application system, the nozzles are agent to create an atmosphere that positioned either overhead or tankside to deliver the dry chemical agent non-toxic to personnel. Your Kidde will not support combustion but is directly onto the hazard being protected. A total flooding system, rec- proper design approach for each of Distributor can help you select the ommended for protection of enclosed your applications. LOCAL APPLICATION TOTAL FLOODING Max. Coverage per Nozzle 2 Nozzles IND 21/25 4 Nozzles IND 45/50 Hazard Longest Area Volume Area Volume Area Volume Height (Ft.) Side (Ft.) (Ft. 2 ) (Ft. 3 ) (Ft. 2 ) (Ft. 3 ) (Ft. 2 ) (Ft. 3 ) 12 or Less 15 112.5 1350 225 2700 450 5400 13 15 104.0 1350 208 2700 416 5400 14 15 96.5 1350 193 2700 386 5400 15 15 90.0 1350 180 2700 360 5400 16 15 84.5 1350 169 2700 338 5400 17 15 79.5 1350 159 2700 318 5400 18 15 75.0 1350 150 2700 300 5400 19 15 71.0 1350 142 2700 284 5400 20 15 67.5 1350 135 2700 270 5400