WEATHER COMPENSATION KIT

Similar documents
RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

USER GUIDE VOGUE MAX SYSTEM

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH)

USERS GUIDE. LOGIC+ Combi 24, 30, 35

Logic+ Combi

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

USERS GUIDE. Electronic Timer, 7 day. LOGIC+ Combi, LOGIC Combi & LOGIC Combi E 24, 30, 35

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

USER GUIDE LOGIC HEAT H

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

Installation Guide Single Zone Thermostat Y87RF

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

USERS GUIDE 24, 30. For installation guide see reverse of book

Multifit. Installation & Commissioning Instructions

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

2 Minimiser SE - User's

INDEPENDENT COMBINATION & SYSTEM BOILERS.

evohome Sundial pack Thermostat

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

12.0 Servicing. Electrode Position Fig Annual Servicing Inspection (Cont) 4 ±0.5

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Wall-hung boilers. Spare parts catalogue. ecotec plus

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

Baxi Maxflow Combi WM

Home. Wiring Guide. Issue 17

Baxi Maxflow Combi FS

NEW BUILD YOUR COMPLETE SOLUTION.

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

GB24 & GB30. User Manual

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

Electronic Room Thermostat

Installation and Instructions for Use Outdoor Sensor

Quick start guide. Connected wireless room thermostat. Logic Combi C / Logic Max Combi C / Vogue Gen 2 Combi / Vogue Max Combi

Fitting & Commissioning Instructions. EcoBlue Combi and System Range. Outdoor Sensor Kit. Kit Part No (System) Kit Part No.

User's Instructions. Alpha CB50

The Ideal Logic. Combination, Heat Only and System Boilers. Heating Solutions.

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

User s Operation Instructions & Important Warranty Information

iheat 25c iheat 30c iheat 35c

UFH Wiring Centre. Installation and Maintenance Instructions. Reliance Water Controls Ltd Worcester Road, Evesham, Worcester, WR11 4RA, UK

Installation and Servicing Instructions. Alpha FlowSmart

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios.

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

A /13

Avanta 24c - 28c - 35c - 39c 18s - 24s - 30s

DOMESTIC BOILER RANGE & ACCESSORIES.

Battery Powered Electronic Room Thermostat Cat. No. TRT033

Electronic Frost Thermostat

INSTRUCTION FOR THE USER THC V E OIL BLU

RT021 User and Installation Instructions

Room thermostat with 24-hour time switch and large LCD

Pedestal Range. Installation and user manual. Kiosk. Trafalgar. Tube. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

SINGLE-CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

Suggested Schematics with Control and Power Wiring details

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h

Installation Instructions

Installation & User s Instructions

EH W 7-Fin Oil-Filled Radiator Adjustable thermostat Built-in carrying handle Safety overload cut-out 2 year guarantee

Operating instructions

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

DOMESTIC BOILER RANGE & ACCESSORIES FROM IDEAL BOILERS.

DOMESTIC BOILER RANGE & ACCESSORIES FROM IDEAL BOILERS.

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

4 in 1 Digital Thermostat Control

CREDA STORAGE RADIATORS

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

User Guide. Please read carefully before use. Your Hoover Guarantee. Your Hoover Guarantee. Contents. IMPORTANT Safety Reminders

Grant UK Internal, Internal System, External, Combi and External Combi Blue Flame Oil Boiler Range UK DOC 0108 Rev 2.5 June 2018

Installation Instructions VITOTRONIC 300

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

Open Vented Condensing Boilers

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

24V dc Terminals X4. 230Vac Terminals X V dc Electrical connections Volt free Room thermostat on/off

Linea HE. High efficiency combi boiler. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

HEAT ONLY & COMBI BOILER

Installation Instructions VITOTRONIC 200

User Manual for model

Avanta 12v - 15v - 18v - 24v - 30v

Control Packs Catalogue. Including control packs compliant with 2013 Building Regulations: Part L

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

MEV-DC. Continuous Mechanical Extract Ventilation Units Installation and Maintenance. Figure 3. Fixing screw hole.

Operating instructions

KIT UNITÀ AMBIENTE E INTERFACCIA A LED KIT ROOM UNIT AND LED INTERFACE RAUMGERÄT UND LED-SCHNITTSTELLE KIT APPAREIL D'AMBIANCE ET INTERFACE À LEDS

PROGRAMMABLE 7-DAY THERMOSTAT

DOMETIC PTY. LTD. Camping Boxes-Refrigerator. Models: RC 1600 EGP Type: JCB - 1. Operating Instructions AUS

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler

User Manual. PO Box 11 Ashton Under Lyne OL6 7TR +44. (0) Fax +44. (0)

EH kW 11-Fin Oil-Filled Radiator

Transcription:

WEATHER COMPESATIO KIT When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal. For the very latest copy of literature for specification and maintenance practices visit our website www.idealboilers.com where you can download the relevant information in PDF format. ovember 2016 UI 216120 A05

This kit is suitable for the following boilers: * OGIC COMBI C24...G.C.o 47-349-18 * OGIC COMBI C30... G.C.o 47-349-19 * OGIC COMBI C35... G.C.o 47-349-20 OGIC COMBI ESP1 24... G.C.o 47-349-21 OGIC COMBI ESP1 30... G.C.o 47-349-22 OGIC COMBI ESP1 35... G.C.o 47-349-23 * I-MII C24... G.C.o 47-349-30 * I-MII C30... G.C.o 47-349-31 OGIC + COMBI C24... G.C.o 47-349-15 OGIC + COMBI C30... G.C.o 47-349-16 OGIC + COMBI C35... G.C.o 47-349-17 OGIC SYSTEM S15... G.C.o 41-750-61 OGIC SYSTEM S18... G.C.o 41-750-62 OGIC SYSTEM S24... G.C.o 41-750-63 OGIC SYSTEM S30... G.C.o 41-750-64 OGIC CODE COMBI ESP1 26... G.C.o 47-349-35 OGIC CODE COMBI ESP1 33... G.C.o 47-349-36 OGIC CODE COMBI ESP1 38... G.C.o 47-349-37 * IDEPEDET COMBI 24... G.C.o 47-349-24 * IDEPEDET COMBI 30... G.C.o 47-349-25 * IDEPEDET COMBI 35... G.C.o 47-349-26 * IDEPEDET+ COMBI 24... G.C.o 47-349-27 * IDEPEDET+ COMBI 30... G.C.o 47-349-28 * IDEPEDET+ COMBI 35... G.C.o 47-349-29 OGIC SYSTEM S15IE... G.C.o 41-750-73 OGIC SYSTEM S18IE... G.C.o 41-750-74 OGIC SYSTEM S24IE... G.C.o 41-750-75 OGIC SYSTEM S30IE... G.C.o 41-750-76 OGIC + SYSTEM S15... G.C.o 41-750-65 OGIC + SYSTEM S18... G.C.o 41-750-66 OGIC + SYSTEM S24... G.C.o 41-750-67 OGIC + SYSTEM S30... G.C.o 41-750-68 OGIC HEAT H12... G.C.o 41-750-77 OGIC HEAT H15... G.C.o 41-750-78 OGIC HEAT H18... G.C.o 41-750-79 OGIC HEAT H24... G.C.o 41-750-80 OGIC HEAT H30... G.C.o 41-750-81 OGIC + HEAT H12... G.C.o 41-750-82 OGIC + HEAT H15... G.C.o 41-750-83 OGIC + HEAT H18... G.C.o 41-750-84 OGIC + HEAT H24... G.C.o 41-750-85 OGIC + HEAT H30... G.C.o 41-750-86 VOGUE C26 GE2... G.C.o 47-349-38 VOGUE C32 GE2... G.C.o 47-349-39 VOGUE C40 GE2... G.C.o 47-349-40 VOGUE S15 GE2... G.C.o 41-750-88 VOGUE S18 GE2... G.C.o 41-750-89 VOGUE S26 GE2... G.C.o 41-750-90 VOGUE S32 GE2... G.C.o 41-750-91 * Refer to Frame 1, item C. Ideal OS2 (Outside Sensor 2) Class II used in isolation, Class VI used with Ideal PRT4 Contribution to Seasonal Space Heating Energy - 2% (Class II), 4% (Class VI) ITRODUCTIO This kit provides the facility to apply outside air temperature control to the boiler water flow temperature which provides energy savings. The outside sensor provided measures outside air temperature and sends a signal to the boiler, which adjusts the maximum boiler flow temperature in response. If outside air temperature is greater than the system design temperature, the boiler flow temperature is reduced providing running cost savings. The boiler will operate in the condensing mode more frequently increasing savings. Once the sensor is fitted it is automatically detected. The sensor operation may be configured by adjustment of the boiler operating parameters, if necessary. 1 KIT COTETS A. Outside Air Sensor B. SAP Registration abel Fixing screw & wall plug supplied inside cover C B C. Connector (Required only for boilers marked with *. See above) Clip on cover Model ame: Model Qualifier: OS2 ErP Class II IDEA BOIERS TD A Terminal block (2 way) wire connection I certify that this boiler is connected to a weather compensation temperature sensor which is compatible with the boiler and provides weather compensation control that has been permanently enabled. The boiler has been commissioned in accordance with manufacturer instructions, which have been supplied to the householder. The central heating temperature control knob should normally be set in the mid-position. OTE. To be mounted onto wall in orientation shown Cable Entry Signed: Date: UI 212050 A01 2 Weather Compensation Kit - Installation

2 FITTIG THE KIT otes. 1. A timer should be fitted to the system so that CH will be switched off when appropriate. 2. The Connector (Frame 1, item C). is prefitted to certain boilers. Boilers that don't have this fitted are marked with an * on page 2. FITTIG THE SESOR The air sensor should be located on an external wall of the building to be heated. Fix the sensor to a north/north-east facing wall to avoid direct radiation from the sun. The air sensor should be located to avoid any heating effect from the boiler flue. To fix the air sensor to the wall, unscrew the sensor box plastic cover and screw/plug the sensor body to the wall. Wire a twin core 0.5mm 2 cable from the sensor to the boiler through a RH grommet located on the underside of the boiler. Cable length between sensor and boiler should be no greater than 20m. ote that this connection is protected extra low voltage. It is not necessary for the person carrying out the wiring to be approved to Part P of the Building Regulations. Avoid running this cable alongside mains voltage cables. WIRIG THE WEATHER COMPESATIO KIT TO THE BOIER 1. Isolate the electricity supply to the boiler. 2. Remove the boiler front panel (refer to boiler installation instructions). 3. Hinge down the control box. 4. Unclip and rotate the installer connections cover towards you until it clips into the retention holes. 5. Connect the wires from the outside sensor into the RHS two terminals of the 4 way connector. Insert the connector into the socket marked 'OPETHERM / WEATHER COMPESATIO' 6. Re-assemble in reverse order. 7. Record your name and today s date on the enclosed label and adhere it to the boiler in a position which will be visible for future inspection. 5 Combi boiler Heat & System 3 ISTAER WIRIG - HEAT & SYSTEM BOIERS OY When fitting the outside sensor to the Heat or System boiler, refer to the changes required to the S and Y plan wiring on the following pages. Weather Compensation Kit - Installation 3

4 ISTAER WIRIG S & Y PA DRAWIGS - OGIC SYSTEM BOIERS OY SYSTEM BOIER WITH Y PA SYSTEM & OUTSIDE SESOR KIT SYSTEM BOIER WITH S PA SYSTEM & OUTSIDE SESOR KIT FUSED SPUR E g b g/y g g/y b br S PA VAVE CH o br o S PA VAVE HW R/S C/S E CH O R/S HW HW C/S O O OFF O BR O BOIER s2 s1 MAIS I I I E TIMER CH O HW O HW OFF 4 Weather Compensation Kit - Installation

5 ISTAER WIRIG S & Y PA DRAWIGS - HEAT BOIERS OY HEAT BOIER WITH Y PA SYSTEM & OUTSIDE SESOR KIT HEAT BOIER WITH S PA SYSTEM & OUTSIDE SESOR KIT Weather Compensation Kit - Installation 5

6 ISTAER WIRIG S PA DRAWIGS - VOGUE SYSTEM BOIERS OY SYSTEM BOIER WITH S PA SYSTEM & OUTSIDE SESOR KIT FUSED SPUR E g b g/y g g/y b br S PA VAVE CH o br o S PA VAVE HW R/S C/S E CH O R/S HW HW C/S O O OFF O BR CH BR HW BOIER s2 s1 MAIS I I I E TIMER CH O HW O HW OFF 6 Weather Compensation Kit - Installation

7 WEATHER COMPESATIO KIT OPERATIO CH OPERATIO The On and Off time control of central heating should be controlled by a separate timer. During programmed On times the Central Heating Radiator Flow Temperature is controlled by the boiler relative to the Outside Temperature as shown in the diagram. The Room temperature can be adjusted using the Central Heating Temperature Control Knob on the boiler as follows. Essentially rotating the knob clockwise increases the room temperature and rotating the knob anti-clockwise decreases the room temperature. The Room Temperature Setpoint in the associated graph is not directly related to the Actual Room Temperature but is the ominal Room Temperature during a programmed CH period. This can be adjusted between 5 and 30 degrees by the CH Potentiometer Knob on the Boiler when the Outside Temperature Sensor is connected. The graph only shows temperatures between 12 and 30 degrees for clarity. Examples: 1. If the CH Potentiometer Knob is set to display 22ºC on the Boiler Display the Room Temperature Setpoint will be 22ºC and the curve 22 will be followed, indicated by 11th curve in from the left hand side. So as the outside temperature varies the Flow Setpoint to the CH circuit will increase and decrease proportionally. 2. If the CH Potentiometer Knob is rotated fully clockwise, the Boiler Display will read 30ºC and the Room Temperature Setpoint will be 30ºC hence the curve 30 will be followed. 3. If the CH Potentiometer Knob is rotated fully anticlockwise, the Boiler Display will read 5ºC and the Room Temperature Setpoint will be 5ºC. This is an unrealistic Room Temperature Setpoint for a CH period during an O time, but it is calculated internally for managing Frost Protection for the system based upon Outside Temperature. DHW OPERATIO When the system is in a timed on period for DHW and the tank stat is not satisfied, OV will be generated on the switched live input S2 of the boiler. This will ensure that Weather Compensation adjustment is ignored at this time. The set point will be fixed at 80 degrees. The demand is indicated on the display by O and the burner on symbol as appropriate. ROOM TEMPERATURE SETPOIT FOW SETPOIT OUTSIDE TEMPERATURE Weather Compensation Kit - Installation 7

WEEE DIRECTIVE 2012/19/EC Waste Electrical and Electronic Equipment Directive At the end of the product life, dispose of the packaging and product in a corresponding recycling centre. Do not dispose of the unit with the usual domestic refuse. Do not burn the product. Remove the batteries. Dispose of the batteries according to the local statutory requirements and not with the usual domestic refuse. Technical Training The Ideal Technical Training Centre offers a series of first class training courses for domestic, commercial and industrial heating installers, engineers and system specifiers. For details of courses please ring:... 01482 498 432 Ideal Boilers td., P.O. Box 103, ational Ave., Kingston upon Hull, HU5 4J. Telephone: 01482 492 251 Fax: 01482 448 858. Registration o. ondon 322 137. Ideal Boilers td. pursues a policy of continuing improvement in the design and performance of its products. The right is therefore reserved to vary specification without notice. Ideal Installer/Technical Helpline Tel: 01482 498663 www.idealboilers.com