REMOTE CONTROL FOR CHILLER MYCHILLER

Similar documents
Index. 1. General description of the application Types of units controlled Types of regulation Condensation...

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

CONTENTS SAFETY SYMBOLS... 1 GENERAL WARNINGS... 1 MAIN FEATURES... 2 MAIN FUNCTIONS... 2 USER UNIT... 3

User manual. pco 1 AQUA 4. Polyvalent air cooled heat pump kw AQUA4-CMA-1405-E. lennoxemeia.com

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

Operation manual. Rooftop Packaged Unit

User Manual Ichill 200 L/D (Firmware version 1.7)

CONTROLS MANUAL. CARRIERrtc basic & medium electronic control 48/50 EN/EH 50 HB/HF/NZ/NF. Original document

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

BLAUAIR AUTOMATIC CONTROL SYSTEM

Installation, Programming and Operating Guide for Digital, Programmable Thermostat with Smart Fan Technology. with SFT (Smart Fan Technology )

AC&R Controller RWR Basic Documentation VR2002 for water to water heat pump units

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB

SC Installation, Operation & Application Guide

OPERATION AND MAINTENANCE MANUAL

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

MO n : 12JMC rév A

TH232-AF-230 Installation Instructions

Safety & Installation Instructions

DC 60 & DM 60 displays

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

Product Manual SZ1009

CTT8 TEMPERATURE MONITOR DEVICE

EXPERT TRI-STAR. Temperature controller. User s Manual

Manual for the integration in BMS/GTC

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N

Model: Touch-RS. 1 Touch-RS

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

Service control manual Smart HP. Application FLBB0mHPGU

Standard Chiller Modular HP 1/4 Generic/Bitzer screw compressor and CAREL valve

Halton SAFE / 7.14 user guide and installation instructions

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Refrigerated air dryers

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

Smart Temp. Model

DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive

DAP III Zone Master User s Guide

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

User s guide. Multiple programming Electronic thermostat

Temperature Controller CC24-7 UNIBOX USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

ETN-24-SUPER-PROG (US Program - Celsius)

Product Manual SZ1022/SZ1031/SZ1035/

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

OPERATING INSTRUCTIONS

T600MEP-2 Programmable Economizer Thermostat

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

Products no longer available

USER MANUAL Comfort System4 TM

USER'S OPERATING INSTRUCTIONS

INSTALLATION & USER MANUAL

User manual CLIMATIC 50 - CHILLERS

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

XC1008D -XC1011D- XC1015D and VGC810

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

FPC-02 Series. Installation and Operating manual

T-32-TS Touchscreen Thermostat. Installation Manual

Please read this manual carefully before installation and use.

CLEVER CONTROL Version: V3

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Elegance. SMT-700 User manual. Ver

MCX ELECTRONIC CONTROLLER

LCF Touch Modbus Datasheet Application Security Advice Caution

Standard Air Handling Units

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Technicians Manual Single Compressor

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1)

SC Installation, Operation & Application Guide

EVF818 Installer manual ver. 1.0 Code 144F818E104 EVF818. Split execution controller for temperaturecontrolled

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

Evolution Control. Zone Control Homeowner s Guide

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort

MCX ELECTRONIC CONTROLLER

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

irad Wireless Controller

User Guide for EHE & EHE Programmable Room Thermostat

5-stage compressor racks + 2 converter outputs

User Manual THR870CUK Programmable Thermostat

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

Air-condensed water cooling units and heat pumps YLCA / YLHA PLUS 5 to 27

Basic Plus2 Room Thermostats Floor Heating

Digital Thermostat Models: VS30W and VS30B

/18 (JRK) MTD User Manual OJ Electronics A/S

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

SC Installation, Operation & Application Guide

GreenCon On/Off Room Thermostat

GreenCon On/Off Room Thermostat

IPC108D - IPC108E (V.2.0)

T7351 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS

Transcription:

REMOTE CONTROL FOR CHILLER MYCHILLER

GENERAL FEATURES... 3 MAIN FUNCTIONS AND EQUIPMENT:... 3 LCD DISPLAY... 4 KEYBOARD... 5 BOARD CONFIGURATION... 7 LIST OF MAIN PARAMETERS... 7 CONFIGURATION OF MAIN PARAMETERS... 8 CONFIGURATION OF UNIT... 9 LIST OF UNIT PARAMETERS... 9 CONFIGURATION OF UNIT PARAMETERS... 9 UNIT READINGS DISPLAY... 11 READINGS LIST... 11 READING DISPLAY PROCEDURE... 11 SETPOINT CHANGE... 12 TIME BAND CONFIGURATION... 13 (ONLY PLUS VERSION)... 13 GENERAL OPERATION... 13 PROCEDURE FOR ACCESSING TIME BAND PARAMETERS... 14 PARAMETER LIST... 15 PARAMETERS DEFAULT VALUES... 17 DISPLAY OF ACTUAL TIME... 17 N.B. FOR REMOTE CONTROL OF UNITS PROVIDED WITH A PCO PROCESSOR WITH THE CLOCK BOARD INSTALLED, MANAGEMENT OF THE TIME BANDS IS ALSO IMPLEMENTED ON THE BOARD SOFTWARE. IF YOU WISH TO MANAGE THE TIME BAND WITH THE REMOTE CONTROL, THIS FEATURE MUST NOT BE ENABLED AT THE SAME TIME ON THE PCO BOARD.... 17 UNIT ALARMS DISPLAY... 18 COMMUNICATION ERROR... 18 ALARM CODES... 19 N.B. FOR A DETAILED DESCRIPTION OF THE ALARMS, CONSULT THE ELECTRONIC CONTROLLER MANUAL. SERIAL COMMUNICATION... 20 CONNECTION TO RS485 COMMUNICATION NETWORK... 21 MODBUS... 22 LIST OF PCO1/PCOXS SUPERVISION PARAMETERS... 22 (MCE TANDEM / MPE TANDEM / MTE / LCE)... 26 CIRCUIT BOARD... 27 WALL INSTALLATION OF CONTROL... 28 TECHNICAL DATA... 30 RG66006100-Rev.01 2

GENERAL FEATURES The chiller remote control was designed to manage cold-only, heat pump and freecooling units through serial communication. The remote control needs to be connected to the unit by means of the connection bus RS485. The remote control can be interfaced with the electronic controllers Carel μchiller2, μchiller2 SE, pco1 and pcoxs by means of the Modbus protocol. MAIN FUNCTIONS AND EQUIPMENT: Switching the unit on/off. Adjustment of temperature setpoint of evaporator infeed water. Changing summer/winter mode (for heat pumps). Displaying and changing main parameters of unit (differentials, minimum and maximum setpoints). Display of advanced parameters (evaporator outfeed water temperature, condensation pressure). Display of alarms active on unit Voltage-free contact for external consent which can enable or disable unit operation Voltage-free contact to enable economy function remotely Built-in clock (only plus version) ON/OFF management and time band Setpoint (only plus version) RG66006100-Rev.01 3

The control panel includes: LCD display keyboard LCD display L 3 O / N F O F Evaporator infeed water temperature / Serial communication error Room temperature / Alarm Setpoint Unit on Unit off Fan speed (only with pco1 / pcoxs) Operation mode: Cooling. Operation mode: Heating. Defrosting Free Cooling active Alarm present Pump active RG66006100-Rev.01 4

Compressor active Electrical resistance working Operation with time bands (only plus solo version) Serial communication. The fixed symbol means that the control is in communication with the unit; flashing means there is not connection Backlighting turns on whenever any button is pressed and turns off automatically about 2 minutes after the last key was pressed (only plus version). KEYBOARD ON/OFF key: Switching the unit on/off when changing user parameters, it allows to return to normal operation. the key does not work when the time band ON/OFF (only plus version) or the digital input ON/OFF are active UP and DOWN keys: changes setpoint. used when changing parameters to select the parameters or to change values. When the unit has an alarm, they scroll the active alarm codes SEL key: accesses setpoint change / selection confirmation MODE key: Selection of Heating / Cooling operation mode (only with unit off) VENT key: temporary display of present time (only plus version) ECO key: cancel parameter change RG66006100-Rev.01 5

Active key combinations Access to parameter configuration procedure Access advanced parameters display Access time band parameters (only plus version) RG66006100-Rev.01 6

BOARD CONFIGURATION LIST OF MAIN PARAMETERS SERIAL ADDRESS: sets Modbus address (between 1 and 247) of controlled unit TYPE OF PROCESSOR: selects the type of controller present on the unit 0: μchiller2 1: μchiller2 SE 2: pco1/pco XS 3: μchiller2 (for MPE and MCE tandem units, MTE, LCE chiller) 4: μchiller2 (for MPE and MCE tandem units, MTE, LCE heat pump) 5: μchiller2 SE (for MPE tandem, MCE tandem, MTE, LCE chillers) 6: μchiller2 SE (for MPE tandem, MCE tandem, MTE, LCE heat pumps) TYPE OF UNIT: 0: Chiller 1: Heat Pump NUMBER OF CIRCUITS: sets the number of chiller circuits of the unit (1 or 2) DIGITAL INPUT CONFIGURATION: configuration of DIN 1/2 0: DIN1 = - DIN2 = - 1: DIN1 = On/Off DIN2 = - 2: DIN1 = - DIN2 = Eco 3: DIN1 = On/Off DIN2 = Eco If the digital input is not active, time band or keyboard switching on/off would have no effect. If the digital input Economy function is active, the set temperature will be changed to the minimum limit (for heating) or the maximum limit (for cooling). Both can be changed by the unit parameter menu of the remote control (only for models provided with μchiller 2 or μchiller 2 SE), or else directly on the controlled unit. DIN1 LOGIC: 0: [open/closed] = [Off/On] 1: [open/closed] = [On/Off] DIN2 LOGIC: 0: [open/closed] = [-/ECO] 1: [open/closed] = [ECO/-] RG66006100-Rev.01 7

CONFIGURATION OF MAIN PARAMETERS simultaneously press the keys use the keys to change the value of the display to the value of the password 10, then press. If correct, you can access the parameters use the keys to scroll the various parameters (see Parameter List described above) press to activate the parameter change (the value will flash) use keys to change the value press to save the new value set or to cancel the change once the concerned parameters have been changed, press the key to exit the procedure RG66006100-Rev.01 8

CONFIGURATION OF UNIT The controlled unit configuration can be changed by accessing a further menu. LIST OF UNIT PARAMETERS SUMMER DIFFERENTIAL WINTER DIFFERENTIAL (only if the type of unit is set at heat pump) MINIMUM SUMMER SETPOINT MAXIMUM SUMMER SETPOINT MINIMUM WINTER SETPOINT (only if the type of unit is set at heat pump) MAXIMUM WINTER SETPOINT (only if the type of unit is set at heat pump) N.B. The pco1/pcoxs control units can only change the differentials CONFIGURATION OF UNIT PARAMETERS simultaneously press the keys use the keys to change the value of the display to the value of the password 30, then RG66006100-Rev.01 9

press. If correct, you can access the parameters use the keys to scroll the various parameters (see Unit Parameter List described above) press to activate the parameter change (the value will flash) use keys to change the value press to save the new value set or to cancel the change once the concerned parameters have been changed, press the key to exit the procedure RG66006100-Rev.01 10

UNIT READINGS DISPLAY Allows to display some values read by the controlled unit. READINGS LIST CURRENT SETPOINT (can be changed by compensations set on the unit) EVAPORATOR OUTFEED WATER TEMPERATURE CIRCUIT 1 CONDENSATION PRESSURE CIRCUIT 1 EVAPORATOR OUTFEED WATER TEMPERATURE CIRCUIT 2 (only if the number of circuits is set at 2) CONDENSATION PRESSURE CIRCUIT 2 (only if the number of circuits is set at 2) READING DISPLAY PROCEDURE simultaneously press the keys to access the readings use the keys to scroll the various parameters (see Readings List described above) press the key to return to the initial screen. RG66006100-Rev.01 11

SETPOINT CHANGE In order to change the evaporator infeed water temperature setpoint, press the key with the control lit (the setpoint will begin to flash) use keys to change the value press the key to store the value. N.B. The set temperature cannot be changed if the time band setpoint management is active or if the remote economy function is active. Should this feature be enabled but not active, the setpoint will continue to be changed with the abovementioned procedure. RG66006100-Rev.01 12

TIME BAND CONFIGURATION (Only plus version) GENERAL OPERATION Time band configuration is performed by setting the relevant parameters (H parameters) properly and in the correct sequence. Procedure for accessing the parameters and the meaning of each parameter will be described in the following chapters. Two time band operation types can be set: ON/OFF time programming: each time band corresponds to the On or Off status of the control. Therefore, the control turns on or off automatically depending on the time band it is in. This feature has no effect if the digital input On/Off function is enabled. Room temperature SET time programming: each time band is associated with a SUMMER SET temperature (for cooling) and a WINTER SET temperature (for heating). They are used automatically by the control as the Set temperature depending on the time band and operation mode it is in. This feature has no effect if the digital input Economy function is active. Two daily profiles can be defined, each of which is divided into three time bands. One or more profiles can be associated to each day of the week. Daily profile 1: ON/OFF = H12 SET SU ON/OFF = H13 SET SUM = H19 SET WIN = H25 ON/OFF = H14 SET SUM = H20 SET WIN = H26 BAND 1 BAND 2 BAND 3 00:00 Hr1 Hr2 23:59 (H04:H05) (H06:H07) Daily profile 2: SUM = H21 SET WIN = H27 SET BAND 4 BAND 5 BAND 6 00:00 Hr3 Hr4 23:59 (H08:H09) (H10:H11) RG66006100-Rev.01 13

PROCEDURE FOR ACCESSING TIME BAND PARAMETERS simultaneously press the keys and use the keys to change the value of the display to the value of the password 5, then press. If correct, you can access the parameters press to activate the parameter change (the value will flash) use keys to change the value press to save the new value set or to cancel the change if the value set for H00 is different than 000, use the keys to scroll the various parameters available (see Parameter List ) once the concerned parameters have been changed, press the key to exit the procedure RG66006100-Rev.01 14

PARAMETER LIST Time band configuration is performed by setting the parameters found one at a time by scrolling with the arrows. Attention: there are 37 parameters on a whole, but not all of them are accessible. Whether some parameters are displayed or not depends on the value assigned to the first parameter (H00), namely based on the type of operation selected. In detail: if H00=1 (ON/OFF mode) the parameters from H18 to H29 are not displayed if H00=2 (SET mode) the parameters from H12 to H17 are not displayed if H00=0 time band mode is disabled and therefore only H00 is displayed The 37 parameters are described hereafter in order: H00 = ENABLING AND OPERATION MODE H00=0 : time bands disabled H00=1 : time bands with ON/OFF H00=2 : time bands with SET temperature CLO: DAY: H01 = HOUR of control clock H02 = MINUTES of control clock H03 = DAY OF THE WEEK Hr1: H04 = HOUR (0-23) of TIME 1 H05 = MINUTES (0-59) of TIME 1 Hr2: H06 = HOUR (0-23) of TIME 2 H07 = MINUTES (0-59) of TIME 2 Hr3: H08 = HOUR (0-23) of TIME 3 H09 = MINUTES (0-59) of TIME 3 Hr4: H10 = HOUR (0-23) of TIME 4 H11 = MINUTES (0-59) of TIME 4 SP1: H12 = STATUS (ON or OFF) of BAND 1 H13 = STATUS (ON or OFF) of BAND 2 H14 = STATUS (ON or OFF) of BAND 3 H15 = STATUS (ON or OFF) of BAND 4 H16 = STATUS (ON or OFF) of BAND 5 H17 = STATUS (ON or OFF) of BAND 6 RG66006100-Rev.01 15

H18 = SUMMER SET temperature of BAND 1 SP2: H19 = SUMMER SET temperature of BAND 2 SP3: H20 = SUMMER SET temperature of BAND 3 SP4: H21 = SUMMER SET temperature of BAND 4 SP5: H22 = SUMMER SET temperature of BAND 5 SP6: H23 = SUMMER SET temperature of BAND 6 SP1: H24 = WINTER SET temperature of BAND 1 SP2: H25 = WINTER SET temperature of BAND 2 SP3: H26 = WINTER SET temperature of BAND 3 SP4: H27 = WINTER SET temperature of BAND 4 SP5: H28 = WINTER SET temperature of BAND 5 SP6: H29 = WINTER SET temperature of BAND 6 Mon: Tue: Wed: Thu: Fri: Sat: Sun: H30 = daily profile (1 or 2) of MONDAY H31 = daily profile (1 or 2) of TUESDAY H32 = daily profile (1 or 2) of WEDNESDAY H33 = daily profile (1 or 2) of THURSDAY H34 = daily profile (1 or 2) of FRIDAY H35 = daily profile (1 or 2) of SATURDAY H36 = daily profile (1 or 2) of SUNDAY H37 = 24H or 12H display RG66006100-Rev.01 16

PARAMETERS DEFAULT VALUES H00 = 0 (time bands disabled) Hr1 = 06:00 Hr2 = 22:00 Hr3 = 08:00 Hr4 = 20:00 H12 = OFF H13 = ON H14 = OFF H15 = OFF H16 = ON H17 = OFF H18-H23 = 12 C H24-H29 = 45 C H30-H34 = 1 H35-H36 = 2 H37 = 24H If the 12H display is set (parameter 37), inside the configuration parameters from H01 to H 11 (except H03) the progressive parameter number is not displayed except for the AM/PM time. DISPLAY OF ACTUAL TIME If the time bands are enabled, when the thermostat is on, the clock symbol will always be displayed and the correctness of the set time can be checked (only for a few instants) by pressing the key N.B. For remote control of units provided with a pco processor with the clock board installed, management of the time bands is also implemented on the board software. If you wish to manage the time band with the Remote Control, this feature must not be enabled at the same time on the pco board. RG66006100-Rev.01 17

UNIT ALARMS DISPLAY Should the controlled unit be in alarm status, the symbol and a flashing error code will appear on the display. This condition will continue until the alarm has terminated or has been deactivated by acting directly on the controller installed on the unit. In order to scroll all the active alarms, use the keys. COMMUNICATION ERROR Should serial communication between the Remote Control and the controlled unit be cut, the display will show an error message accompanied by the corresponding symbol flashing. If communication is restored, the symbol will quit flashing and the evaporator infeed water temperature will return on the display. RG66006100-Rev.01 18

ALARM CODES μchiller 2 / μchiller 2 SE C1 : Circuit 1 alarm (high pressure / low pressure / circuit breaker / anti-freeze) C2 : Circuit 2 alarm (high pressure / low pressure / circuit breaker / anti-freeze) HP1 : Circuit 1 pressure switch high pressure alarm LP1 : Circuit 1 pressure switch low pressure alarm HP2 : Circuit 2 pressure switch high pressure alarm LP2 : Circuit 2 pressure switch low pressure alarm FLO : Water flow alarm Prb : Probe alarm Hrc : Compressor operation time threshold overcome warning pco1 / pcoxs FLO : Water flow alarm tin : Evaporator infeed water temperature probe alarm to1 : Evaporator outfeed water temperature probe alarm circuit 1 to2 : Evaporator outfeed water temperature probe alarm circuit 2 Pr1 : Condensation pressure probe alarm - circuit 1 Pr2 : Condensation pressure probe alarm - circuit 2 tfc : Freecooling temperature probe alarm AMB : Outdoor temperature probe alarm LP1 : Low pressure alarm - circuit 1 LP2 : Low pressure alarm - circuit 2 HP1 : High pressure alarm - circuit 1 HP2 : High pressure alarm - circuit 2 th1 : Circuit breaker alarm circuit 1 th2 : Circuit breaker alarm circuit 2 RG66006100-Rev.01 19

Ft1 : Fan circuit breaker alarm bench 1 Ft2 : Fan circuit breaker alarm bench 2 Pt1 : Pump 1 circuit breaker alarm Pt2 : Pump 2 circuit breaker alarm PHS : Phase direction alarm AF1 : Anti-freeze alarm circuit 1 AF2 : Anti-freeze alarm circuit 2 dig : Digital alarm Hrc : Compressor operation time threshold overcome warning N.B. For a detailed description of the alarms, consult the electronic controller manual. RG66006100-Rev.01 20

SERIAL COMMUNICATION CONNECTION TO RS485 COMMUNICATION NETWORK The Bus communication network is made up of a two-wire shielded cable connected directly to the RS485 serial ports of the remote control (A, B and GND terminals). For the network, use a two-conductor twisted shielded AWG 22-24 cable with less than 50 pf/m capacity between the wires. For connection with pco1 / pcoxs controllers, a RS 485 serial board is required; for connection with μchiller 2 / μchiller 2 SE controllers, the 485 serial option is required, with key input connection. RG66006100-Rev.01 21

MODBUS The protocol implemented in the control is Modbus RTU (9600, N, 8, 2) on RS485 IMPLEMENTED FUNCTIONS 0x01: Read Coil Status 0x02: Read Input Status 0x03: Read Holding Registers 0x04: Read Input Registers 0x05: Force Single Coil 0x10: Write Multiple registers IMPLEMENTED EXCEPTIONS Exception Code 02: Invalidate data address LIST OF PCO1/PCOXS SUPERVISION PARAMETERS ADDRESS COIL TYPE 1 Unit status R/W 2 Summer/Winter R/W 31 Compressor 1 R 32 Compressor 2 R 33 Compressor 3 R 34 Compressor 4 R 35 Compressor 5 R 36 Compressor 6 R 37 Compressor 7 R 38 Compressor 8 R 41 Pump 1 R 42 Pump 2 R 43 Bench fans 1 R 44 Bench fans 2 R 45 Resistance R 56 Circuit 1 defrost R 57 Circuit 2 defrost R 62 General alarm R 71 Dig. inputs alarm R 72 Pump 1 circuit breaker alarm R 73 Pump 2 circuit breaker alarm R 74 Flow alarm R 75 Tin probe alarm R 76 Tout1 probe alarm R 77 Tout2 probe alarm R 78 Pcond.1 probe alarm R 79 Pcond.2 probe alarm R 80 Tfc probe alarm R 82 Text probe alarm R 83 Circ.1 LP alarm R 84 Circ.2 LP alarm R 85 Circ.1 HP alarm R RG66006100-Rev.01 22

86 Circ.2 HP alarm R 91 Circ.1 circuit breaker alarm R 92 Circ.2 circuit breaker alarm R 93 Fan.1 circuit breaker alarm R 94 Fan 2 circuit breaker alarm R 97 Phase direction alarm R 98 Ev. anti-freeze alarm 1 R 99 Ev. anti-freeze alarm 2 R 100 Compr. threshold overcoming 1 R 101 Compr. threshold overcoming 2 R 102 Compr. threshold overcoming 3 R 103 Compr. threshold overcoming 4 R 104 Compr. threshold overcoming 5 R 105 Compr. threshold overcoming 6 R 106 Compr. threshold overcoming 7 R 107 Compr. threshold overcoming 8 R ADDRESS REGISTER TYPE 1 Cond. 1 pressure R 2 Cond. 2 pressure R 3 IN water temp R 4 OUT 1 water temp R 5 OUT 2 water temp R 6 Outdoor temp R 8 Active Setpoint R 13 Minimum summer set R 14 Maximum summer set R 15 Minimum winter set R 16 Maximum winter set R 31 Summer Setpoint R/W 32 Winter Setpoint R/W 33 Summer Differential R/W 34 Winter Differential R/W LIST OF μchiller 2 supervision parameters ADDRESS COIL TYPE 31 Circ. 1 alarm 1 R 32 Circ. 1 alarm 2 R 35 General alarm R RG66006100-Rev.01 23

36 Probe alarm R 37 Compr. time overcoming R 44 Flow meter alarm R 45 Circ.1 HP alarm R 46 Circ.1 LP alarm R 49 Compressor 1 R/W 50 Resistance 1 R/W 51 Pump R/W 53 Digital alarm R/W 54 Unit status R/W 55 Summer/Winter R/W 58 Circ. 2 HP alarm 2 R 59 Circ. 2 LP alarm 2 R 62 Compressor 2 R/W 63 Resistance 2 R/W ADDRESS REGISTER TYPE 41 Summer Setpoint R/W 42 Summer Differential R/W 43 Winter Setpoint R/W 44 Winter Differential R/W 47 Minimum summer set R/W 48 Maximum summer set R/W 49 Minimum winter set R/W 50 Maximum winter set R/W 70 IN water temp R 71 OUT water temp R 72 Outdoor temp R 73 Cond. pressure R 232 Defrost R LIST OF μchiller 2 SE supervision parameters ADDRESS COIL TYPE 41 Circ. 1 alarm 1 R 42 Circ. 1 alarm 2 R 45 General alarm R 46 Probe alarm R 47 Compr. time overcoming R 54 Flow meter alarm R 55 Circ.1 HP alarm R 56 Circ.1 LP alarm R 59 Compressor 1 R/W 60 Resistance 1 R/W 61 Pump R/W 63 Digital alarm R/W 64 Unit status R/W 65 Summer/Winter R/W 68 Circ. 2 HP alarm 2 R 69 Circ. 2 LP alarm 2 R 72 Compressor 2 R/W 73 Resistance 2 R/W RG66006100-Rev.01 24

ADDRESS REGISTER TYPE 41 Summer Setpoint R/W 42 Summer Differential R/W 43 Winter Setpoint R/W 44 Winter Differential R/W 47 Minimum summer set R/W 48 Maximum summer set R/W 49 Minimum winter set R/W 50 Maximum winter set R/W 102 IN water temp R 103 OUT water temp R 104 Outdoor temp R 105 Cond. pressure R 341 Defrost R LIST OF μchiller 2 supervision parameters (MCE TANDEM / MPE TANDEM / MTE / LCE) ADDRESS COIL TYPE 31 Circ. 1 alarm 1 R 32 Circ. 1 alarm 2 R 35 General alarm R 36 Probe alarm R 37 Compr. time overcoming R 44 Flow meter alarm R 45 Circ.1 HP alarm R 46 Circ.1 LP alarm R 49 Compressor 1 R/W 50 Resistance 1 R/W 51 Pump R/W 52 Compressor 2 R/W 53 Digital alarm R/W 54 Unit status R/W 55 Summer/Winter R/W 58 Circ. 2 HP alarm 2 R 59 Circ. 2 LP alarm 2 R 62 Compressor 3 R/W 63 Resistance 2 R/W 65 Compressor 4 R/W ADDRESS REGISTER TYPE 41 Summer Setpoint R/W 42 Summer Differential R/W 43 Winter Setpoint R/W 44 Winter Differential R/W 47 Minimum summer set R/W 48 Maximum summer set R/W 49 Minimum winter set R/W 50 Maximum winter set R/W RG66006100-Rev.01 25

70 IN water temp R 71 OUT water temp R 72 Outdoor temp R 73 Cond. pressure R 232 Defrost R LIST OF μchiller 2 SE supervision parameters (MCE TANDEM / MPE TANDEM / MTE / LCE) ADDRESS COIL TYPE 41 Circ. 1 alarm 1 R 42 Circ. 1 alarm 2 R 45 General alarm R 46 Probe alarm R 47 Compr. time overcoming R 54 Flow meter alarm R 55 Circ.1 HP alarm R 56 Circ.1 LP alarm R 59 Compressor 1 R/W 60 Resistance 1 R/W 61 Pump R/W 62 Compressor 2 R/W 63 Digital alarm R/W 64 Unit status R/W 65 Summer/Winter R/W 68 Circ. 2 HP alarm 2 R 69 Circ. 2 LP alarm 2 R 72 Compressor 3 R/W 73 Resistance 2 R/W 75 Compressor 4 R/W ADDRESS REGISTER TYPE 41 Summer Setpoint R/W 42 Summer Differential R/W 43 Winter Setpoint R/W 44 Winter Differential R/W 47 Minimum summer set R/W 48 Maximum summer set R/W 49 Minimum winter set R/W 50 Maximum winter set R/W 102 IN water temp R 103 OUT water temp R 104 Outdoor temp R 105 Cond. pressure R 341 Defrost R RG66006100-Rev.01 26

CIRCUIT BOARD S E Where A-B-GND RS 485 N Neutral L Phase PE Earth DI1 Dig.1 input CI12 Common dig.1-2 DI2 Dig.2 input NB: o o o for power connection, use 1 mm 2 section cable for digital inputs, use AWG 24 cables for probe extensions and RS485, use AWG 24 shielded cables RG66006100-Rev.01 27

WALL INSTALLATION OF CONTROL NB: for wall installation, it is recommended to use an electrical box behind the control to house the wires. NB: before installation, carefully remove the protective film on the display. Film removal may cause dark halos to show up on the display which will disappear in a few seconds and are not a sign of a defect. Instructions for wall installation 1. Remove the control's closing screw. Fig. 1 2. If a 503 electrical enclosure is used, pass the cables through the slot at the bottom of the control and use the holes provided for fastening. Fig. 2 RG66006100-Rev.01 28

3. Otherwise drill holes in the wall where you would like to install the control, matching the fastening slots (5 x 8 mm) at the bottom of the control. Pass the cables through the slots at the bottom and fix it to the previously drilled holes in the wall with screws. Fig. 3 4. Perform the electrical connections on the terminal board following the relative electrical layout. 5. Close the control fastening the screw removed in point 1. RG66006100-Rev.01 29

TECHNICAL DATA Power supply Operating temp Storage temp Relay Connectors Digital inputs 90-250Vac 50/60Hz Power 8W Protective fuse: 500mA delayed Range 0-50 C Range -10-60 Normal Open 5A @ 240V (Resistive) Insulation: coil-contacts distance 8mm 4000V coil-relay dielettric Max room temperature: 105 C 250V 10A Voltage-free contact Closing current 2mA Max closing resistance 50 Ohm RG66006100-Rev.01 30

NOTES

Company UNI EN ISO 9001 and OHSAS 18001 certified 40010 Bentivoglio (BO) Via Romagnoli 12/a Tel. 051/8908111 Fax. 051/8908122 www.galletti.it