Cold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended

Similar documents
Cold Deck Canopy and Shelf Lights and Retrofit Kit

Cold Door 2 LED Retrofit Kit Lighting System

HighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75

Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits

Innovative Lighting R-Series Vertical Refrigeration

Innovative Lighting R-Series Overhead LED Conversion Kits

Dioluce Products Installation Instructions

INSTALLATION INSTRUCTIONS

1 General Description

EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy

1 x4 Dimmable LED RetroFits

Installation Instructions

Owner s Guide and Installation Manual

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

Honeywell Durafit LED Retrofit Kit

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

installation and operation manual for Hunter Ceiling Fans

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Owner s Guide and Installation Manual

EcoBrite Smooth Light LED Light Fixtures

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

Table of Contents. What to Expect with. Mounting Options. Tools Needed

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

Owner s Guide and Installation Manual

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

LED Flat Panel Retrofit

Owner s Guide and Installation Manual

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

Owner s Guide and Installation Manual

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Type 2 Models. Owner s Guide and Installation Manual. English Español

Installation Instructions for W2H Series Signals

Table of Contents. What to Expect with Your Installation. Tools Needed. Mounting Options. Ceiling Bracket. Wiring.

Installation Guide. For Models: E-PD52ABZ5C4 E-PD52BP5C4 E-PD52WW5C4 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

WAILEA OWNER S MANUAL

Installation Instructions

3DIR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3DIR52XXD

Installation Instructions

Installation Instructions. Tersen. Ratio Canopy 1.5

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

5LCM52XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : AC-552AL

F.P.O. Installation Guide. For Placement Only

Owner s Guide and Installation Manual

14PRR62XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 14PRR62(X)

HPNLS-RT. Installation Manual

Fillmore Small Pendant Assembly and Installation Instructions

Installation Guide. For Models: E-DCF52BNK5C3 E-DCF52FBZ5C3 E-DCF52MWW5C3 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

LED IMPORTANT SAFETY INSTRUCTIONS

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Owner s Guide and Installation Manual

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Downrod. Canopy.

5AZR56XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5AZR56XX

CONTENTS BEFORE YOU BEGIN

LED IMPORTANT SAFETY INSTRUCTIONS

ST. KITTS CEILING FAN

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

Table of Contents What to Expect with Your Installation. Tools Needed. Motor Housing.

Installation Instructions

Installation and Operation Manual For Hunter Ceiling Fans

Table of Contents. 1 M /10/14 Casablanca Fan Company. What to Expect with Tools Needed.

Installation Guide. For Models: E-MLV36BNK4LK1 E-MLV36ESP4LK1 E-MLV36WW4LK1 READ THESE INSTRUCTIONS AND AND SAVE THEM FOR FUTURE USE

3SKYR56XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 3SKYR56(XXXXX)

3VNR52/42XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3VNR52XXD / 3VNR42XXD

5GFR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5GFR52XXD

Installation Guide. For Model: COS52OSB5CR READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE. net weight of fan: lb (9.9 kg) PRINTED IN CHINA

TSLED STAIRWELL INSTALLATION INSTRUCTIONS

ProStar Ceiling Fan PS52. Installation Instructions Instrucciones de instalación Instructions d installation

INSTALLATION INSTRUCTIONS

Table of Contents What to Expect with. Mounting Options. Tools Needed. Downrod. Blades

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

3AVOR56XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 3AVOR56XXXXX

L A signature series TA T N E RE O, A L L A T S IN

3CLMR56XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3CLMR56XXD

LaceyTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

LED Emergency Battery Backup

3MAVR60XXD Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 3MAVR60XXD

GRANDE OWNER S MANUAL

Hanson LED C e i l i n g F a n

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

LED IMPORTANT SAFETY INSTRUCTIONS

DRAIN WATER TEMPERING INSTALL

DRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

Please read and save these instructions. Should you have any questions or difficulty installing your fan, call us first!

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

Owner s Guide and Installation Manual

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Preparation. Downrod. Maintenance.

installation and operation manual for Hunter Ceiling Fans

IMPORTANT SAFETY INSTRUCTIONS:

LED IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

Juna Ceiling Fan JU54. Installation Instructions Instrucciones de instalación Instructions d installation

Ceiling Fan Installation Instructions

SPECTRE BY. D778,422; D779,052; D779,093; D792,577; Add'l U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE

Transcription:

General Information Cold Deck FIT LED lighting systems are intended for use inside of commercial refrigerated display merchandisers for food zone, splash zone, and non-food zones only. Cold Deck FIT LED lighting systems are Class 2 low voltage luminaires intended to replace standard fluorescent fixtures in refrigerated multi-deck merchandisers after electronic ballasts have been replaced by SloanLED 24 VDC power supplies. WARNING Risk of Fire or Electric Shock. Not for direct replacement of Fluorescent Lamps. Use only with SloanLED Power Supply (P/N 701936, or 701895-24W, or 701895-24C or 410175). Use only a damp cloth and mild cleaning agent to clean Cold Deck FIT luminaires. Cold Deck FIT Retrofit Kit (retrofit kit), in the context of this guide, is all of the component parts needed, including these installation instructions, for a retrofit luminaire conversion. Retrofit luminaire conversion is the act of modifying, with the parts provided in the retrofit kit, a luminaire already manufactured and in service in order to convert the luminaire to a LED light source from its original light source. The refrigerated display merchandiser is considered the luminaire in this context, and the complete retrofit kit is assembled during the audit of each merchandiser, on site, prior to installation. Tools and Accessories Recommended Do not remove existing primary merchandiser wiring. Tools and connections shown are for primary connections: Gloves, safety glasses, flat and Phillips head screwdrivers, screws, standard drill, measuring tape, electrical tape, wire strippers, twist-on or push-in UL Listed wire connectors, tie-wraps, and UL Listed 18 gauge wires (multiple colors such as white, black, blue, and red are useful to avoid confusion, but not required). Items Purchased for Installation 1. Cold Deck FIT Canopy Light 2. Cold Deck FIT Shelf Light 3. Stand-off Clips 4. Power Supplies 5. Retrofit Sticker 6. Dimming Controller (optional) 7. Motion Sensor (optional, Wide Angle shown) 8. Clip Spanner Wrench 9. Tombstone Retrofit Grommets (2 included) 1 2 3 4 5 6 7 8 9 Check to ensure correct count of bill of materials prior to removing installed lamps and ballasts. NOTE: Cold Deck FIT Canopy Lights are intended to be used in canopy of multi-deck merchandisers only. Any attempt to install these luminaires into trough or under shelving may cause damage to merchandiser and/or performance may not match literature specifications. Cold Deck FIT Shelf Lights may be installed under shelving. PAGE 1 OF 7

Luminaire Directivity Cold Deck FIT Canopy Light Cold Deck FIT Shelf Light Luminaire Placement Canopy Shelves For Your Safety Read and understand all instructions in this installation guide prior to retrofitting any refrigerated display merchandiser. Read and observe all NOTES, CAUTIONS, and WARNINGS shown throughout these instructions. Installation must be performed by trained service personnel only. Cold Deck FIT Retrofit Kit (retrofit kit) is UL Classified; luminaires are UL Listed for dry, damp, and wet locations, as well as food zone, splash zone, and non-food zones in commercial refrigerated display merchandisers. Gloves and safety glasses should be worn at all times during installation. Safety goggles are recommended during power supply installation. Retrofit kit electrical input specifications: Up to 1.4 A Max, 100-240 VAC. Retrofit kit electrical output specifications: Up to 3.7 A, 100 W, 24 VDC, Class 2 circuit. Retrofit kit is accepted as a component of a luminaire where suitability of combination shall be determined by CSA or authorities having jurisdiction (Canada only). Do not make or alter any open holes in an enclosure of wiring or electrical components during installation. ly open holes indicated in photographs and/or drawings may be made or altered as a result of retrofit kit installation. Do not leave any other open holes in an enclosure of wiring or electrical components. WARNING To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. WARNING Risk of fire or electrical shock. Luminaire wiring, LED Driver, or other electrical parts may be damaged when drilling for installation of retrofit kit. Inspect wiring and components for damage. WARNING Risk of fire or electrical shock. Install this retrofit kit only in luminaires that have constructional features and dimensions shown in photographs and/or drawings. WARNING Risk of fire or electrical shock. Install this retrofit kit only in luminaires used in refrigerated display merchandisers that have constructional features and dimensions shown in photographs and/or drawings. INSTALLATION OF THIS RETROFIT ASSEMBLY REQUIRES A PERSON FAMILIAR WITH CONSTRUCTION AND OPERATION OF FLUORESCENT LIGHTING LUMINAIRE ELECTRICAL SYSTEMS AND HAZARD INVOLVED. WARNING Risk of fire or electrical shock. Retrofit kit installation requires knowledge of fluorescent lighting luminaire electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. Install to NEC, state, and local regulations. ce conversion is complete, adhere sticker provided that says This luminaire has been modified and can no longer operate originally intended lamp near lamp on/off switch located in refrigerated display merchandiser. PAGE 2 OF 7

Preparation for Installation Multi-deck Merchandiser Canopy Canopy Shelves Front rail 1. Warning: Risk of electrical shock. Locate main circuit breaker panel, de-energize, and perform lockout/tagout prior to retrofitting merchandiser. All primary wiring must be done by a licensed electrician. 2. Prior to beginning work, perform an audit and visual inspection of refrigerated display case to be retrofitted. Locate and note original equipment manufacturer's (OEM) part number and serial number. If possible, obtain and review OEM's set up and installation manual, specifically sections that relate to location of power switch, number and location of all fluorescent lamp holders and ballasts, and wiring diagram. If no OEM documentation can be obtained, case must be visually inspected prior to installation. Locate all pairs of fluorescent lamp holders and note number and locations. Lamp holders are normally in canopy, under shelves, and in front rail. A typical 12' (3600 mm) merchandiser will have between 15 and 27 pairs of lamp holders, and will have five (5) to nine (9) ballasts to power them (in a ratio of 3:1). CAUTION: All ballasts must be located and removed during retrofit procedure. If all ballasts cannot be located, stop retrofitting procedure and contact OEM for assistance. 3. As required, remove fluorescent bulbs and reflectors (if present) from canopy, under shelves, and inside front rail. Dispose of bulbs per local, state, or federal regulations. Refer to http://lamprecycle.org for guidance. 4. Determine angle of light channel. Using a plumb-bob or other method, determine angle of inclination and record. Check for features on light channel which may cause an obstruction of light pattern from luminaire. If an obstruction is present, measure height and note. Ensure that luminaire can be installed at this height while remaining behind canopy fascia after installation. NOTE: If light channel is angled, a pilot hole should be marked and drilled prior to drilling screws in. Canopy Lights may have pilot holes drilled prior to closing light channel if required. Possible obstruction height, y y Measure this angle θ Ensure luminaire is hidden behind this feature Determine light channel geometry. 5. Determine proper configuration of angled Stand-off Clips needed for given merchandiser construction. Each angled Stand-off Clip imparts a 5 angle on Canopy Lights. If clips are stacked facing same way, angle progressively increases with each clip in 5 increments. If clips are stacked in an alternating orientation (front to back), total angle that canopy is held at zero and clips become a 0.5" (12.7 mm) stand-off. NOTE: Configurations are additive. alternating # of alternating Stand-off Clips incline # of inclining progressive Stand-off Clips Angle measured, θ combination Stand-off height, y 0 1 5 0.25 0 2 10 0.50 2 0 0 0.50 4 0 0 1.00 2 2 10 1.00 Create 3 sets of clips per canopy light. 6. Remove electrical raceway cover. With some merchandisers, raceway cover may be entire canopy panel. Refer to OEM's manual for instructions on how to access existing ballasts for canopy and shelf lights. CAUTION: Weight of canopy panel and bundled wiring may cause panel to swing down upon removal of final screw. Dust and debris may have accumulated on panel since original installation. Safety goggles are recommended. PAGE 3 OF 7

Remove Ballasts and Install Power Supply 7. Cutting primary and secondary wires at ballast, remove installed ballasts and install appropriate number of power supplies based on respective number of Canopy and Shelf Lights. Canopy Shelf LAMP #1 LAMP #1 LAMP #1 LAMP #1 LAMP #1 LAMP #1 LAMP #1 Typical wiring diagram for a 12' (3600 mm) multi-deck merchandiser before retrofit conversion, with three (3) rows of canopy lamps and lamp holders along with four (4) rows of three (3) shelves. CAUTION: Power supplies should not be mounted near any other heat generating element. 8. Connect primary power to power supply (refer to wire description on power supply label). Use UL Listed twist-on or push-in connectors for connections. Follow connector manufacturer's instructions. Table 1 Cold Deck FIT maximum lights per power supply 701895 Series/701936 Canopy Shelf 4' (1200 mm) 3 12 3' (910 mm) 4 16 410175 Series Canopy Shelf 4' (1200 mm) 3 0 3' (910 mm) 4 0 NOTE: Any combination of lights may be used up to a total of 90 W on a 701895-24C, 701895-24W, or 701936 power supply, or 36 W on a 410175 power supply. NOTE: ly one (1) Canopy Light is required to replace up to three (3) fluorescent lamps in canopy. NOTE: PRIMARY WIRING CONNECTIONS: AC Neutral to Power Supply White; AC Line to Power Supply Black; Earth Ground to Power Supply Green. PAGE 4 OF 7

Remove Ballasts and Install Power Supplies (cont.) 9. Optional - Install Dimming Controller and Motion Sensor: Connect Dimming Controller to secondary side of power supply. Use Cat 5 cable to connect Motion Sensor to Dimming Controller. 11. Energize system and test lamp holders for electrical shock hazard. Ensure that no unused wires are exposed after installing power supply. Re-energize system via power switch. Using a voltmeter or multimeter, check for voltage, both AC and DC, between fluorescent lamp holders for all shelf and canopy lights. Measurements should read 24 VDC ± 0.25 V and there should be 0 VAC ± 1 VAC. CAUTION: Primary and secondary wiring needs to be physically separated inside of raceway. NOTE: e (1) Dimming Controller required per power supply. NOTE: If AC voltage measured, line voltage is present on low voltage side of system. De-energize system and troubleshoot accordingly. Install Canopy Lights Typical wiring diagrams for a 12 (3600 mm) retrofitted multi-deck merchandiser with three (3) Canopy Lights and four (4) Shelf Lights with dimming. 10. Attach secondary wiring to power supply: Connect all RED wires from removed ballasts to RED output wire on power supply (or DC) and all BLUE wires from removed ballasts to BLACK output wire on power supply secondary. Use Terminal blocks for easier power supply connections. NOTE: All tombstones should be connected to secondary of power supply. 12. With raceway still open, locate all pairs of tombstones. Push tombstones back out of dropped canopy. Cut tombstones off secondary wiring. 13. Attach Stand-off Clips as shown in diagram.use appropriate length (based on number of Stand-off Clips required from Step 5), self-drilling/self-tapping, #8 or #10, pan or hex head screws. 14. Affix appropriate configuration of Stand-off Clips for centerline-line mounting of Canopy Light. PAGE 5 OF 7

Install Canopy Lights (cont.) Install Shelf Lights 21. If case was left re-energized from previous step, de-energize case again, performing lockout/ tag out as required. 22. Locate all pairs of tombstones in shelving, and corresponding raceways that support tombstones. 23. Remove electrical raceway that houses incumbent lamp holder. Cut wires from base of lamp holder/tombstone, remove lamp holder. 15. Lock Canopy Light into place using Clip Spanner Wrench. 24. Place Shelf Lights. Shelf Lights initial method of attachment is via magnets, with primary method of securement via screws through end caps. Place Shelf Lights on flat surface that fully engages as many magnets as possible. Shelf Lights can be placed up to 12" (300 mm) away from fluorescent lamp holders. Mechanically fasten luminaires into place by screwing through holes in end caps using an appropriate fastener and if necessary, slide silicone grommet onto luminaire cable. NOTE: Do not install lights in such a way that raceway becomes inaccessible in following steps. 25. Connect appropriate wires to flying lead from LED luminaire using twist-on or push in UL listed wire connectors. Connections should be RED-to RED and BLACK-to-BLUE. Replace raceway in its original location. NOTE: Make all secondary connections inside of raceway. 16. Secure Canopy Light by installing appropriate length mounting screws through end cap mounting slots. 17. Close holes created in canopy. Place tombstone retrofit grommets on luminaire leads, and thread leads and grommets into open side of canopy, closing those holes and protecting cabling. Ensure that no new holes were created during retrofit. Plug all other holes with appropriate hole plugs. 18. Connect lights. Connections should be RED-to-RED, and BLACKto-BLUE. Repeat for as many canopy lights as needed. It does not matter which pair of wires are chosen, only that corresponding colors are correlated correctly. Cap any unused wires. 26. Close holes created in shelving, if any. Push silicone tombstone retrofit grommets into place in raceways as needed. Ensure that no new holes were created during retrofit. 27. Replace electrical raceway. Ensure all wires are clear of pinching. Use tie-wraps to help organize and secure wires, if necessary. Turn on System 28. Energize main circuit breaker. Confirm proper luminaire operation. 19. Power check for canopy lights. Perform an ON/OFF check to ensure all connections are made properly. 20. Replace electrical raceway cover. Ensure all wires are clear of pinching; pinched wires will cause panel to close improperly. Use tiewraps to help organize and secure wires if necessary. Replace screws removed in Step 5 of this installation guide. This completes installation of Canopy only lights. If this completes your retrofit, permanently re-energize circuit breaker. If Open Deck Merchandiser also has shelf lights to retrofit, proceed to following section. PAGE 6 OF 7

Dimming Controller Settings Factory setting is 100% Brightness, 0% Dimming. Merchandising Setting (Brightness) Brightness Level SW 1 SW 2 Percent of Full Brightness SW 3 SW 4 Dim Mode SW 3 Off SW 4 SW 3 Energy Saver ON OFF 50% 15% 0% 0% Standard OFF ON 75% 30% 7.5% 0% MerchandiserMax ON ON 100% 55% 25% 15% SW 4 Off Selectable Duty Cycle output via SW 1 and SW 2 (Brightness level when shopper in area). Selectable Duty Cycle output via SW 3 and SW 4 (brightness level when no shoppers in area). Percentage values represent brightness and power of maximum system load. Dimming Controller 701890-PWR Removal Instructions 1. De-energize system as outlined in Preparation for Install section on Page 3 of this installation manual and undo electrical connections to LED lights. 2. Grab light with a free hand. 3. For Canopy Lights: Using wrench provided, disengage center mounting clip. Using appropriate sized screwdriver or nut driver, remove mounting hardware and remove luminaire from merchandiser. For Shelf Lights: Remove mounting hardware. Disengage mounting magnets from under-shelf and remove luminaire from merchandiser. Optional Dimming Control Part Number Dimming Controller 701890-PWR Motion Sensor, Standard 400661 Motion Sensor, Wide Angle 400964 See datasheet for further details. Datasheet available at SloanLED.com. 4. Repeat process for remaining lights. Make sure to continually support LED lights with a free hand during removal. 5. Open electrical raceway cover and remove power supplies. 6. Cap or remove all primary wires. Cold Deck FIT is covered by US and foreign patents pending. NSF/ANSI 2 UL Retrofit file number: E355292 UL Low Voltage Luminaires and Fittings file number: E329727 UL NSF/ANSI 2 file number: SA33165 Customer service and technical support 888.747.4LED (888.747.4533) SloanLED.com info@sloanled.com Europe: Customer service and technical support +31 88 12 44 900 SloanLED.com Europe@SloanLED.com P/N 402023 Rev D 2017-11-15 PAGE 7 OF 7