STAINLESS STEEL TRAP VALVE STATION

Similar documents
Hydrocarbon & Chemical Processing Solutions

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Intelligent Refrigeration Solutions

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

Intelligent System Solutions Steam Air Hot Water

THERMODYNAMIC STEAM TRAPS

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

Our Know-How. Your Peace of Mind. Steam Solutions

LIQUIDATOR UMT-TD Series Thermodynamic

Pure Performance For Steam Mains and Tracers

Steam Traps and Steam Specialties

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

THERMODYNAMIC STEAM TRAPS

Installation and Testing of Inverted Bucket Steam Traps Manual

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

Pump & Trap Combinations

CD-33/CD-33S Controlled Disc Steam Traps

Liquid Drainers LIQUID DRAINERS

THERMOSTATIC STEAM TRAPS

Yarway Narvik Steam Desuperheater Series 4300 TempLow

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Pure Performance For Steam Mains and Tracers

Series 1140 and 1141 Temperature Regulators

LIQUIDATOR 450 SERIES

UNIVERSAL STYLE STEAM TRAPS WU450 Series

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

SECTION Pipeline Ancillaries

THE THERMOSTATIC STEAM TRAP

High Pressure Water - Descale Valves - VXXX Series. Quad-S TM Poppet Cartridge Zero Leakage, Media Piloted Raw Water Operation

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV

Installation and Maintenance "L" and "LS" Series

Economical and simplified solutions that offer quality and optimum steam trap service.

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

APPLICATION GUIDELINES STEAM MAIN DRAINAGE

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

LEVEL SENSED DRAINS KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP 50 KAPTIV-CS-HP 500 NUFORS-CR MAGY-UL

STEAM TRAPS

Disc Type Steam Trap TSD-42

DRYAIRE DESICCANT SYSTEM MODEL 6760

TIMER CONTROLLED DRAINS

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

THERMODYNAMIC STEAM TRAP

Chapter 2.3: Steam System

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Air Vents AV-392. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps.

GESTRA. Program for Universal Connections. The Smart Solutions

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

Bringing Energy Down to Earth

KEEP YOUR TRAP SHUT OR GET THE CONDENSATE OUT

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP NUFORS-CR MAGY-UL MAGY COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS LEVEL SENSED DRAINS

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

How to Trap: Trap Selection and Safety Factors

STEAM CONSERVATION GUIDELINES

F-P, F-L, FT-P AND FT-L SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL

Threaded. Flanged. Model PSH. Primary Secondary Header A-451

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

The right trap for the right application.

Flow Control for Fire Protection

Inverted Bucket Steam Traps

Pressure Swing Desiccant Dryers

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Hoffman Specialty General Catalog

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

Steam Trap Selection

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

Insty-Pac Steam Humidifiers

Why steam trap survey?

How to Trap: Installation and Testing

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Refrigerant Valves/Accessories

EXTERNALLY HEATED DESICCANT AIR DRYERS. GEHD Series

Fisher Means Control. Introducing a new standard in self-powered temperature control valves. FISHERregulators.com

LONGONI ENGINEERING SRL

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

InterSeptor Centrifugal Separators Operating & Maintenance Manual

Steam Conservation Guidelines for Condensate Drainage Steam Trap Sizing and Selection.

KPS-DS, KLS-DS, KPT-DS AND KLT-DS SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL

Product Family Overview

INSTALLATION, OPERATION

PIP PNE00004 Steam Trap Guidelines

EXTERNALLY HEATED BLOWER PURGE DESICCANT AIR DRYERS. GBPD Series

HumidiPack,HumidiPackPlus and HumidiPackPlus CF Steam Humidifier Systems

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

Transcription:

STAINLESS STEEL TRAP VALVE STATION MAKES A LONG STORY... 36 [914 MM]...SHORT. 4.75 [121 MM]

THE INNOVATION IS INTEGRATION Armstrong stainless steel Trap Valve Station (TVS) reduces your costs for installation, maintenance and energy by integrating the steam trap and valves into a single, spacesaving package. Our patented TVS transforms a long, complicated, installation process into a much simpler, more compact task while eliminating numerous potential leak points in piping, and providing all the functions of multiple components in a smaller, smarter unit. Armstrong TVS dramatically shortens installations for even simple piping arrangements, replacing lengthy procedures like valve-nipple-strainer-nippletrap-nipple-valve with a far simpler, pipe-tvs-pipe. THE ADVANTAGES OF ARMSTRONG STAINLESS STEEL TVS INCLUDE: Reduced costs Provides savings by eliminating potential leak points and reducing installation and maintenance time. Simplicity Eliminates procurement and assembly of many individual components. Multiple functions Includes test and strainer blowdown valves and accommodates Armstrong Intelligent Monitoring AIM remote steam trap monitoring and testing devices. Reduced design time Permits combining products with exact face-to-face dimensions. Quality assurance Our TVS is backed by a three-year no leak guarantee. Easy, in-line repairability with maximum safety Allows isolation at point of service with upstream/downstream depressurization; removal of two bolts allows the steam trap to be serviced. Installation versatility Adaptable to any manufacturer s two-bolt steam trap and piping configuration; and fits all connection specifications for installations, including a flanged spool piece, npt, or sw. Simplified trap testing Includes enhanced capability to check trap operation and a built-in method to block and bleed traps.

ARMSTRONG INVERTED BUCKET STEAM TRAP Invented by Armstrong in 1911, the Inverted Bucket (IB) Steam Trap has been proven to seal better, last years longer and outperform any other type of trap on the market today. Engineered for a longer, more efficient service life, Armstrong IB Steam Traps continue to conserve energy, even in the presence of wear. With fewer costs for replacement parts, installation and downtime, the long-term savings and value they provide can be dramatic. Lightweight and compact, Armstrong IB Steam Traps are tamperproof, corrosion-resistant and can withstand freeze-ups without damage. Armstrong is so sure of their performance that we guarantee them against leaks for three years. ARMSTRONG IB STEAM TRAPS ARE YOUR MOST EFFECTIVE CHOICE FOR BEST PRACTICE ENERGY MANAGEMENT. BENEFITS INCLUDE: Longest service life of any type steam trap Proven energy conservation Dependable operation because there s nothing to stick, bind or clog Purging action due to snap opening of the valve Continuous automatic air and CO2 venting Excellent operation against back pressure Resistance to damage from water hammer Freedom from dirt problems

SAFETY, SAVINGS AND SIMPLIFICATION ARMSTRONG 360 CONNECTOR Armstrong 360 Connector enables simple installation of the Armstrong IB Steam Trap into any piping configuration, with little or no repiping. Our universal connector brings together a stainless steel IB Steam Trap and piston valves in a variety of practical combinations. In fact, we can meet the specifications for any type of steam trap. The standard version of the stainless steel TVS uses the connector block to merge a steam trap and two shutoff valves into one integrated unit. The connector block can also accommodate two additional valves. Options include: a bleed valve depressurizes the trap before it is removed from the connector block; a test valve is used to test and evaluate trap operation. TEST AND SAVE Steam trap testing is a wellaccepted component of aggressive energy management, and it is essential to the efficiency of a well-designed and properly maintained steam system. Armstrong TVS allows you to test your steam traps with greater safety and accuracy, while providing substantial savings in time and labor cost. To see how important reliable steam trap monitoring can be, consider the following example: A 3/16 (4.8 mm) orifice leaking 100 lb (45 kg) of steam per hour at 50 psi (3.4 bar) will squander $4,380 worth of energy in one year, assuming a steam cost of $10/1,000 lb (450 kg). Most experts agree that testing steam traps with test valves is the most reliable method because it permits you to check trap discharge visually. Test valves allow you to see evidence of trap failure that is difficult to detect with other test methods. The sooner you can see a problem, the sooner you can begin saving the precious energy that failed traps waste. Armstrong TVS enhances your ability to check trap operation and it provides a built-in way to block and bleed traps for maximum safety and ease of maintenance. Safety, savings and simplification are the benefits of TVS when it comes to routine trap testing. Not only does our TVS simplify installation and maintenance, it also makes regular testing simpler, safer and quicker saving you both time and money.

THE PROOF IS IN THE PISTON VALVE We chose a piston valve to integrate the IB Steam Trap with the TVS because it is the only type of valve capable of matching our IB Steam Trap in terms of reliability and energy efficiency. The piston valve features excellent sealing characteristics in steam service and has no gland packing, making it a frequent choice for steam systems. Even with no maintenance, leakage to atmosphere is extremely rare. The elastic contact between piston and valve sealing rings provides a perfect tightness, both in-line and to atmosphere. Benefits include dual sealing action, automatic retightening and in-line repairability. Steam system valves, whatever their design, are used to isolate steam and condensate lines, or when a faulty steam trap needs to be removed from the line. This means that valves stay in the open position for long periods and are nearly always in contact with the atmosphere. So when the valves need to be closed, they can often prove difficult to operate. Our experience and the demands from end users for energy efficiency have led us to a sealing system designed especially for steam service. OPEN POSITION CLOSED POSITION Dual sealing action The piston valve is a seatless valve which includes two graphite and stainless steel valve sealing rings that seal the stem and function as a valve seat. This combination provides longterm protection against leaks to the atmosphere and downstream piping. Self-cleaning action Stainless steel piston slides without rotating between the two valve sealing rings, preventing dirt from damaging the sealing surfaces Sealing integrity Flexible disc springs automatically provide leak tightness by exerting pressure which keeps the upper and lower valve sealing rings compressed at all times. Sealing tightness is assured by the compression of the sealing rings against the piston and the valve body. This combination of disc springs and dual valve seal rings protects against expansion and contraction due to heating and cooling. This assures dependable operation, even after years of service. Protected valve stem The valve stem and sealing surfaces are completely protected from dirt and corrosion by the stem cap, whether in an open or closed position. In-line repairability All valve components may be easily replaced in-line. Long-term operation Piston valve design assures actuation even after many years without operation.

INTELLIGENT SOULUTIONS IN STEAM, AIR, AND HOT WATER Armstrong International 816 Maple St., Three Rivers, MI 49093 Phone: 269-273-1415 456 7891 Fax: 269-278-6555 armstronginternational.com Armstrong International, Inc. Catalog No. 109 8M 9/97 Printed in U.S.A.