Water Leak Detector BA/LDT Accessories Termination and Troubleshooting

Similar documents
Water Leak Detector. Installation and Troubleshooting. Overview

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

Duct and Rough Service Carbon Monoxide Sensor

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

aquilar - leak detection solutions

Installation, Operation and Maintenance Manual

DH500ACDC Intelligent Air Duct Smoke Detector Housing

breeze easytm model # F100-1W

aquilar - leak detection solutions

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Snifter. User Manual. Distributor

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

B.I.C.A Built-In Coffee Appliance

MANUAL RESET ALARM RELEASE

INSTALLATION INSTRUCTIONS

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPSCLCMCQRL Merchandising Hot Cabinets

CC-2222C-PL, CC-2222C-PRL, CC-2222C-PR-2, CC-2222C-PL-2,

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

Ultraviolet Monitoring System. Part Numbers UV/MS-1 V3 UV/MS-2 V3. Installation And Operations Manual

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPS36CLCMQRL i7 Hot Cabinet

MODEL /4" Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload

LIMITED LIFETIME WARRANTY

Installation & Maintenance Instructions

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

STEAMPRO. Steam Generator Troubleshooting and Service Guide

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Gate Operator. Modfications

NS1100 / NS2200 Installation Guide & Owner s Manual

Oxygen (O2) Single-Point Gas Detection System

Macurco HD-11 Hydrogen Gas Detector

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Operations Manual. Motion Detector Module Model ZS10

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS. Aluminum Blinds - Standard - - Lift & Lock -

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

FAUX WOOD BLINDS 2 & 2-1/2 SLAT SIZES

30-YEAR LIMITED WARRANTY

SEC 2000 Millenium Infrared Gas Detector

RKA-LEL Sample Draw Combustible Gas Detector

DETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS

K Series (Model A) Fan Forced Wall Heaters

Two-Channel Gas Controller

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

ImPress IRONING STATION

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

DISHWASHER INSTALLATION INSTRUCTIONS

PO Box 827 Hawley, MN (218) Fax (218)

ELECTRIC STOVE HEATER Models: FS2213B

FLCH4R Garage and Utility Electric Heater

SERIES 500. Installation & Maintenance Instructions. Ceiling Mounted Fan Forced Heater WARNING SAVE THESE INSTRUCTIONS. Recessed Mount.

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Analog Room Pressure Monitor RPC Series

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Versatility. Maximum Energy Savings

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

Side Entry Bushing (SEB) High Temperature Cable Clamp Bushing Installation Instructions

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE

CEILING FAN OWNER'S MANUAL

P4200PM / P5000PM Remote Air Dryer User s Guide

REV: 000. Lumitron/ Luminator

CEILING FAN OWNER S MANUAL

installation and operation manual for Hunter Ceiling Fans

Ceiling Fan Ow n e r s Manual

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

Sintrol Snifter A1+ Manual. Version 1.2.2

DryAire DRYING CABINET

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Features TREASURE HUNTER S CODE OF ETHICS

DIGITAL METERS Large Display Temperature Meters Instruction Manual

CEILING FAN OWNER'S MANUAL

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE

TRADITIONAL CONCEPT INSTRUCTION MANUAL WARRANTY CERTIFICATE

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

User s Manual & Operating Instructions

SOLO OWNERS MANUAL, OPERATING INSTRUCTIONS & INSTALLATION INSTRUCTIONS

The feedhorn heaters consist of heater wire attached to a strap and covered with heatshrink. They are attached to a rib on the feedhorn.

Snifter ATEX22 VERSION. User Manual. Distributor

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario

Series. Access Power Controllers. Installation Guide

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

Transcription:

Overview & Identification The is designed to sense the presence of water and alert a central monitoring system of the potentially destructive situation. Upon water detection, an alarm relay changes state, and a local red LED illuminates. The transmitter can be set for latching alarm or non-latching alarm with normally energized or de-energized operation. An optional remote water sensor is available for small inaccessible locations such as AHU pans or under floor water detection. Fig. 1: Water Leak Detector with Internal Sensor Probe Fig. 2: with Built In Sensor and a 5 Amp Relay in a System Diagram (Side View) Fig. 3: with Remote Spot Sensor (right) and Water Rope Sensor (below) Fig. 4: with Remote Spot Sensor or optional Water Rope Sensor (not shown) and a 5 Amp Relay in a System Diagram (Side View) 1 of 6

Mounting Place the transmitter in a location where a water leak is likely to cause damage such as a cooling coil pan, a hot water tank pan, under a sink, under an elevated floor, or in a drop ceiling under pipes. The transmitter can be independently mounted in a visible location by using a remote water sensor and waterproof cable as shown in Fig. 4. Terminate the transmitter as shown in the termination section. 1. Set the transmitter where water is most likely to be a problem or in the collection pan under the water coil or heater (Fig. 5). Alternatively the water sensor can be attached to the pan edge with two set screws (Fig. 6). Do not over tighten or puncture the pan. Alternatively a remote water sensor can be attached to the pan or floor with mounting tape (Fig. 7). Clean surface thoroughly before setting the sensor in place and push sensor down firmly. Mount the detector enclosure in a visible location within cable length of the remote water sensor. Alternatively a remote water sensor can be attached to the floor with screws (Fig. 8). Mount the detector enclosure in a more visible location within cable length of the remote water sensor. Alternatively the rope water sensor can be laid on the floor or under pipes as shown in Figs. 10, 11, 12 & 13. Cable clamps can be used to secure the sensor to the floor. 2. Adjust the depth screw on the sensor probe in the middle of the open enclosure to the alarm depth (Fig. 5). If using a remote water sensor, adjust the depth screw as shown in Fig. 9. The rope sensor detects water 1/8 off the floor and has no adjustment. 3. Run the cable to the transmitter location leaving enough slack to terminate and allow for some repositioning as needed. Use a strain relief on the entering cable so the wires do not tug on the terminals directly. 4. Terminate and configure in accordance with the termination section. Fig. 5: Leak Detector with Sensor in a BAPI-Box Pan edge mounting screws Detection depth adjust screw Fig. 6: Water Sensor Pan Rim Mounting Firmly push down on clean surface Fig. 7: Remote Water Sensor Tape Mount Fig. 8: Remote Water Sensor Floor Mount Installer-provided mounting screws Fig. 9: Remote Water Sensor Depth Adjusting Detection depth adjust screw Reference probe Detection depth adjust from 1/16 to 1/2 depth Up Down 1. Loosen wing nut. 2. Set the required depth of the sensor probe screw using a #2 Phillips screwdriver. 3. Hold the sensor probe screw stationary with the screwdriver. 4. Turn the wing nut down the probe screw until it engages the plastic. 5. Tighten the wing nut 1/4 turn into the plastic. 2 of 6

Mounting continued... Fig. 10: Hot Water Tank Pan Mounting Fig. 11: Sub-Floor Sensor Mounting Fig. 12: Vertical Pipe Sensor Mounting The following combinations of sensors can be used: 1. Two rope sensors with a combined length of no more than 100. 2. Two spot sensors with a combined length of no more than 75. 3. One spot sensor with a maximum length of 25 and one rope sensor of no more than 50. Note: Shielded or twisted pair wire cannot be used to extend the sensor wires. This applies to both the remote spot sensor as well as the rope sensor. Fig. 13: Horizontal Pipe Sensor Mounting 3 of 6

Wiring and Termination Terminal Description A...Water Sensor (No polarity to water sensor cable) B...Water Sensor (No polarity to water sensor cable) NC2*...Alarm Contact 2, Normally Closed to C2 when De-energized C2...Alarm Contact 2, Common NO2...Alarm Contact 2, Normally Open to C2 when De-energized NC1*...Alarm Contact 1, Normally Closed to C1 when De-energized C1...Alarm Contact 1, Common NO1...Alarm Contact 1, Normally Open to C1 when De-energized GND/NEU Power supply ground/neutral Fig. 14: Leak Detector Circuit Board V+/HOT...Power supply input 24VAC/VDC +/- 10% *Not used for low current relay version, SPST, Form A Sensitivity Adjustment for 10 and 100 Remote Rope Sensors The unit s leak detection sensitivity is set at the factory. However, for the 10 and 100 remote rope sensors, the sensitivity may need to be adjusted in the field. If you are using a 10 remote rope and it won t respond, rotate the sensitivity adjustment potentiometer 5 turns counterclockwise. If you are using a 100 remote rope and it is too sensitive, then rotate the sensitivity adjustment potentiometer 5 turns clockwise. Sensitivity Adjustment Potentiometer Fig. 15: Leak Detector Circuit Board 4 of 6

Set Up and Commissioning Indication/Controls Description Red LED...LED illuminates when water is detected Green LED...LED illuminates when normal power is applied Reset Button...Resets latching alarm contact (only if water is no longer present) Latching Relay...Left side of J1 set to top two pins listed as L Non-Latching Relay...Left side of J1 set to bottom two pins listed as N (Default) Supervised Relay***...Right side of J1 set to top two pins listed as S (Default) Unsupervised Relay...Right side of J1 set to bottom two pins listed as U *** Supervised means the relay is energized when not in alarm and the relay de-energizes on a power failure or alarm. 1. After the unit is installed and wired, turn on the power. (24VAC/VDC +/- 10%) 2. Check that the green LED is on. If it is not on, check the power source. 3. Dampen a cloth or sponge and touch both the sensor probe tip and the sensor base. An alarm should occur within 5 seconds. 4. The red LED should illuminate and the relay(s) should de-energize, or energize if set up as unsupervised. (To check relay status, measure the resistance at the relay contacts or monitor the status from the BAS screen.) 5. Remove the dampened rag or sponge to clear the alarm. If the unit is set up for a non-latching relay (J1 jumper across the N pins), the red LED and relay(s) will energize, or de-energize if set up as a unsupervised relay. If the unit is set up for a latching relay (J1 jumper across the L pins), the operator must push the reset switch on the detector board or interrupt power to clear the alarm. 6. Check the depth screw (see Mounting Section) to be sure it s at the appropriate water depth for alarm. Operation Sequence When power is applied, the green LED will illuminate and and the unit will start to detect for water at the sensor probe. When there is no detection of water (normal condition), the relays are not in an alarm state and the red LED remains off. For units set up in the unsupervised relay mode, the relays are de-energized. For units set up in the supervised relay mode (default), the relays will be energized. (Note: When there is a loss of power, a supervised relay will drop out indicating a water detection alarm.) Within 5 seconds of water detection, the relays go into an alarm state and the red LED illuminates. For units set up in the unsupervised relay mode, the relays are energized. For units set up in the supervised relay mode (default), the relays are de-energized. If the unit is in non-latching or auto-reset (default) operation, then the alarm state will automatically reset when the water has dried up. If the unit is in latching or manual-reset operation, then the unit will stay in an alarm state until the reset button is pressed or power is cycled. If there is still water detected during a reset button push, the unit will not reset. If there is still water detected after a power interrupt, the unit will initiate another alarm within 5 seconds. Diagnostics Possible Problem Green LED Not On Red LED Not Working Or Relay Not Energizing. Unit Will Not Reset Possible Solution 1. Check for proper power to the unit (see power specs on back page). 1. Check for proper power to the unit (see power specs on back page). 2. Check if water is touching the sensor probe and reference probe. 3. Adjust sensor probe depth. 4. For rope sensor units, check the sensitivity adjustment as described on page 4. 1. Check for the presence of water or debris touching the two sensor probes. 2. Be sure the sensor wires are not shorted. 3. If the L pins on J1 are shorted, push the reset button or cycle power. 4. For rope sensor units, check the sensitivity adjustment as described on page 4. 5 of 6

Maintenance Check the water sensor probe once a year to be sure there is no dirt or debris collected around the probes. Dirt or debris around the probes may cause nuisance alarms in moist situations. Change the service intervals depending on environmental conditions. In very clean conditions the probe may never need maintenance. Rope sensor may be wiped down with isopropyl alcohol, warm soapy water on a cotton cloth or placed in a dishwasher. Cautions/Warnings This unit is not intended to be a safety device. In no event shall BAPI or its officers, directors, employees or agents be liable to any company or individual for any indirect, incidental, special, exemplary, punitive or consequential damages including, without limitation, economic or commercial losses, arising out of or resulting from the misuse of this water detector as a safety device. Specifications Power: 24VAC/VDC +/- 10% 5 Amp Relays: 4 Watt/ 4 VA max 0.5 Amp Relays: 2 Watt/ 2 VA max (not intended to switch a load) Wiring: Relays Transmitter Mounting: Sensor: Standard Optional Optional Flex Connector or Liquid Tight Fitting Up to 6 wires 2 wires for Power Lays in the pan or attached with a pan edge hook with screws Single SS probe from bottom of BB with adjustable depth screw from.063 to.84 Remote water sensor with depth screw with adjustable depth from 1/16 to 1/2 Remote long line water sensor (Rope) Detects water over the full length at depths >0.125. Note: 100 ft maximum including non-sensing extension cable. Detector Transmitter: Alarm Contacts LDT1: One SPST, 0.5A relay output, 10W max LDT2: Two SPST, 0.5A relay outputs, 10W max LDT3: One SPDT, 5A relay output LDT4: Two SPDT, 5A relay outputs Indication Reset Action SPST or SPDT, 30 VAC/DC max Selectable as normally Energized or De-energized 1 Green Power LED, 1 Red Alarm LED If latching, local push button or power interrupt Sensor Reaction Responds to presence of water within 5 seconds Termination: Agency: Terminal strip, 4-10 terminals, 12-24AWG RoHS, UL94V-0, UV-rated in Enclosure Set Up: BB Sensor Remote Sensor Latching Jumper Adjustable depth from.063 to.84 ( 1/16th default) Adjustment depth from 1/16 to 1/2 ( 1/16th default) Latching Version - Stays energized after water has dried up Non-Latching Version (default) - Alarm follows wet or dry surface Supervision Supervised Version (default) - Jumper De-energized when in alarm. Note: Relay will drop out on loss of power indicating a water detection alarm. Unsupervised Version - Energized when in alarm. Enclosure Ratings: Remote Sensor Submersible, w/fep plenumrated, waterproof cable Rope Sensor Plenum rated Transmitter BAPI-Box, NEMA 4 Ambient: Remote Sensor -40 to 185ºF (-40 to 85ºC), 0 to 100%RH, Condensing Transmitter (BB) -40 to 185ºF (-40 to 85ºC), 0 to 95%RH, Non-condensing Rope Sensor 32 to 167ºF (0 to 75ºC), 0 to 95%RH, Non-condensing Enclosure Materials: Remote Sensor Aluminum bracket w/abs plastic shell Transmitter (BB) Polycarbonate Note: This unit is not intended to be a safety device. 6 of 6