Rosemount Analytical Solutions. Emerson Offshore Technology Day March 26th 2015 by Rune Damgaard, Account Manager - Measure & Analyze

Similar documents
Dräger REGARD -1 Control System

Industrial Grade Gas Detection

Industrial Grade Gas Detection

Sieger Apex. Flexibility that meets your requirements

Dräger REGARD -1 Control System

A New Standard of Excellence

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Series 9000 Total Hydrocarbon Analyzer

Dräger QuadGard Control System

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Emission Monitoring System

Autocalibration Systems for In Situ Oxygen Analyzers

Industrial Grade Gas Detection Detecting The Difference

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

HFID Heated Total Hydrocarbon Analyzer Module

Rosemount 1500XA Process Gas Chromatograph

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Chemtron Science Laboratories Pvt. Ltd.

Dräger REGARD -1 Control System

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

DELIVER AS PROMISED A COMMITMENT TO CALIBRATION SERVICES ALL BRANDS & MAKERS PRESSURE / TEMPERATURE GAUGES & CALIBRATORS ULLAGE TAPES

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8310 IR Detection of flammable gases and vapour

APPLICATION DATA SHEET

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

Rosemount 1500XA Process Gas Chromatograph

SUPREMATouch. Modular Fire & Gas Detection System

ULTIMA X5000. MSAX5000.com

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

PRODUCT CATALOGUE. Gas & Air Quality Detectors Controllers Transmitters

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Toxic Gas Detection. Model F12. Toxic Gas Detection

Dräger PIR 3000 Detection of flammable gases and vapours

Sieger fixed gas detection. Fixed protection from hazardous gas

Autronica Fire and Security AS ID:

Process Gas Chromatograph

SUPREMATouch Modular Fire & Gas Detection System

Dependable Solutions for Gas Detection

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

Using the DewTrak II Dew Point/ Humidity Transmitter

MSA Fixed Gas & Flame Detection for the Automotive Industry

Recalibrate the way you look at gas detection

Dräger REGARD 3900 Series Control System

IGD.CO.UK

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Model D12-IR. Digital Gas Transmitter...

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

SUPREMATouch. Modular Fire & Gas Detection System

FPD - Flame Photometric Detector

31/1 ถ.กร งธนบ ร คลองสาน กร งเทพฯ โทร: , , โทรสาร:

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Fixed Gas Detection Equipment

Complete Gas Analysis

Process Gas Chromatograph

Accuracy by Design Products for the HVAC Professional

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

Dew-Point Transmitters and Instruments

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Dust Alert 75. *shown with optional external keypad and display

Dräger X-am 7000 Multi-Gas Detection

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Using the Model 1500 Portable Chilled Mirror Hygrometer

incontrol Systems Inc. Flame and Gas Detection

Process Gas Chromatograph

HIGH CAPACITY PRODUCT LINE

S5000 Gas Monitor. GMS5000.com

Transmitter OCX 4400 THE LATEST BREAKTHROUGH FOR COMBUSTION FLUE GAS ANALYSIS. Product Data Sheet PDS A01 February, 2001

TD80 LEVEL GAUGING & OVERFILL PREVENTION SYSTEM PRODUCT MANUAL SUPPLEMENT. TPM 005 Revision 0.0

Dräger Polytron Pulsar 2 Open Path Gas Detector

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Dräger Polytron 7000 Fixed gas detector

TQ4400 TANKSCAN GAS SAMPLING SYSTEM OPERATING MANUAL

GAS ANALYSIS / DETECTION Gas Detector

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

SOUTH AFRICAN NATIONAL STANDARD

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

Net Safety ST3 XChem Toxic Gas Sensor

931D Style B Process Gas Chromatograph

Recent Improvements in Process GC Instrumentation

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

P R O D U C T D ATA S H E E T

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Gas Chromatography (GC-342)

RESOLUTION MSC.292(87) (adopted on 21 May 2010) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

MONITORING & MEASURING EQUIPMENT FOR EMISSION MONITOR, HAZARD DETECTION & ENERGY OPTIMIZATION VERSION 1. 1

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Zircomat Oxygen Analyzers

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

Dräger PIR 7200 Toxic Gas Detection Transmitter

Figure 1 DirectLine DL423 Sensor. Description, continued

NEBOSH International Technical Certificate in Oil and Gas Operational Safety

HIGH CAPACITY PRODUCT LINE

ALTAIR 5X Multigas Detector Product Specification

Transcription:

Rosemount Analytical Solutions Emerson Offshore Technology Day March 26th 2015 by Rune Damgaard, Account Manager - Measure & Analyze

Innovation applied to Offshore Applications Well head analysis Process GC Sample handling system for well gas. H 2 S analyze. Platform Safety Gas leak detection Aspiration systems Gas/smoke detection for gasturbines, H 2 S drilling areas, ventilations etc Water For reinjection ph / Conductivity / dissolved oxygen Complete systems Quality analysis GC for natural gas quality. C6+, C9+, hydrocarbon dew point.

Rosemount Analytical Business Unit Rosemount Analytical Gas Analysers Systems and Solutions Instruments Fire and Gas Detection Process Gas Chromatographs Standard Solutions Liquid Panels and Natural Gas Systems Liquid Sensors and Transmitters Flame Detection Continuous Gas Analysers Bespoke Systems and Solutions Combustion Analysers Flammable and Toxic Gas Monitoring

Process Analysis for Liquids and Gases Liquid sensors Systems Process gas analysers Combustion analyzers GC Gas detection

Injection Water Analysis ph, Conductivity and Dissolved Oxygen

DO /ph / Cond analyze system SS 316 Cabinet with SHS Sample Handling System inside heated box The sample handling system includes: - isolating valve - pressure gauge - filter - pressure regulator with pressure gauge - check valve (for overpressure in the system) - flow meter with needle valve - sensor flow cell (plastic material) - Material after customers choice. Slide 6

DO(ppb) analyze system for injection water Ultrasonic Gas Leak Detection

GDU Incus: Key features Uses floating piezo ceramic sensing heads Detects flammable, toxic or asphyxiant gas Large detection area (40m) Calibrated for life Fully sealed Flexible mounting Continuous self test HART Slide 8

Emersons Process Gas chromatograph Model 500 installed at North Alwyn, North Sea since 1990. Slide 9

- The Gold Standard C6+ 3 minute +/- 0.01 % HV in controlled environment +/- 0.015 % HV in -20 to 60 C C9+ HCDP 5 minute +/- 0.0125 % HV in controlled environment +/- 0.025 % in -20 to 60 C HC Dew Point Calculation Thermal Conductivity Detector (TCD) Flame Ionization Detector (FID) Flame Photometric Detector (FPD) 90 to 240 VAC or 24 VDC 4 streams or optional 8 streams Optional Full color LCD [File Name or Event] Emerson Confidential 27-Jun-01, Slide 10 10

370XA Gas Chromatograph Smaller, Simpler, and Smarter C6+ Analysis Unique Maintainable Module Full Function Local Operator Interface Trusted Danalyzer C6+ 4-minute Analysis

Preemraff, Reflux, 2 sample streams Emerson make over 100 gas- and liquid system every year in Europe.

Aspiration systems

Aspiration Systems Aspirators are instrument air driven sampling systems for gas and/or smoke detection. Emerson/Grovely are the Aspirator supplier of choice in the UK offshore market. Nearly 800 systems sold. Shell, ExxonMobil, Chevron, ConocoPhillips, Total, Gazprom, Petrobras, Statoil and Marathon are users. Slide 14

Emerson/Groveley GDA Gas & Smoke Aspirators Instrument Air driven sampling systems. Can be used with any vendors optical smoke, toxic & flammable gas detectors Design reduces compression fittings, hence maintenance Modular design (up to 5 channels) Custom Built from standard parts Suitable for use in Zones 1 or 2 Slide 15

Emerson/Groveley GDA Gas & Smoke Aspirators Application examples: Ingress of flamable/toxic gas/smoke into HVAC Ducts Flamable gas in riser caissons Protection of Safe Refuges H2S around drilling areas Gas build up beneath gas tight floors Gas build up in Cargo Holds and ballast tanks Slide 16

Emission monitoring Gasturbines NOx, CO, CO 2, SO 2 and O 2

MLT or X-Stream Process Gasanalyzers Emission monitoring of NOx, CO, CO 2, SO 2 and O 2. Complete systems with sample probe, heated tube, internal sample handling system. 3000 systems world wide Zero/Span Auto

X-Stream Enhanced Gasanalyzers Analyzes up to four components Offers dualcompartment version with separated physics and electronics Includes a web browser interface with data, calibration and event logger

MLT Multicomponent Gasanalyzers Analyzes up to five components in a single/dual compartment enclosure (IP65) Front-panel display and key pad

Airborne Particle Monitor and Oil Mist Detector (APM) The Net Safety Millennium Airborne Particle Monitor and Oil Mist Detector (APM) is a specially designed instrument using infrared and optical detection technology to monitor ambient air for the presence of any type of particulate matter.

PRIMARY FEATURES ROBUST DESIGN FOR USE IN EXTREME INDUSTRIAL AND MARINE APPLICATIONS FIELD SELECTABLE SENSITIVITY NOT EFFECTED BY AIR VELOCITY ANALOG 4-20mA AND 3 FORM C RELAY OUTPUTS LOCAL AND REMOTE RESET CAPABILITY TO CLEAR LATCHED ALARMS AND FAULT IDENTIFICATION GLOBAL CERTIFICATIONS

APM applikationer HVAC, smoke detection in ventilation. Marine application, load-and unload of oil Gasturbines, oil leakge in bearings. Battery rooms, toxic gas after short circuit

Thank You for Attending and enjoy the rest of the conference Our global customer knowledge sharing event and technology exhibition. 300+ papers and work shops.