Installation, Operating and Servicing Instructions

Similar documents
User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

User and Installation Instructions. Electric Auto-Fill Water Boilers EB3F, EB4F, EB6F, EB6TF IS339 ECN3539

Installation, Operating and Servicing Instructions. Lynx 400 Electric Salamander Grill LGT

Installation, Operating and Servicing Instructions. Silverlink 600 Electric Pasta Boilers PB33, PB66

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions. Seal Heated Display Bars HB1, HB2, HB3, HB4, LD2, LD3, LD4

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions. Opus 800 Electric Cook & Hold Salamander OE8306

Installation, Operating and Servicing Instructions. Opus 700 Electric Salamander Grill OE7304

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions. Lynx 400 Heavy-Duty Contact Grill GG1, GG1R, GG1P

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions

USER INSTRUCTION MANUAL. Autofill Water Boiler

User and Installation Instructions C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100

INSTALLATION AND USER INSTRUCTIONS

Installation, Operating and Servicing Instructions

INSTALLATION AND USER INSTRUCTIONS

The Professional s Choice

The Professional s Choice

User and Installation Instructions. Opus 700 Electric Salamander Grill OE7304 IS318 ECN3011

Opus 800 Gas Fryers OG8110, OG8110/OP, OG8111, OG8111/OP, OG8111/OP2, OG8106, OG8106/OP, OG8107, OG8107/OP

LT4X AND LT6X Electric Slot Toasters

OE7008 & OE7010 Electric Oven Ranges

Installation, Operating and Servicing Instructions. Opus 800 Gas Open Top Oven Ranges OG8001 & OG8002

The Professional s Choice

MIX Boiler & Font Range Service Manual

INSTALLATION, USER AND SERVICING INSTRUCTIONS FOR ESLR9C OVEN RANGE

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

IS09 ECN2087. EB3, EB4 & EB6 Automatic Fill Water Boilers INSTALLATION, USER & SERVICING INSTRUCTIONS

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

Mira Sport Max with Airboost

User and Installation Instructions. Opus 700 Electric Wet Well Bain Marie OE7601 IS195 ECN2396

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

Autofill counter top water boiler

OPUS Electric Chip Scuttle OE7109 USER /INSTALLATION INSTRUCTIONS

AQUARIUS 45 MARINE SERVICE MANUAL

Mix Boiler & Font Range ( #, #, #, , )

USER INSTRUCTION MANUAL. Autofill Wall Mount Boilers /12/14

INSTALLATION AND USER INSTRUCTIONS COUNTERTOP AND FREE STANDING FRYERS

User and Installation Instructions. Seal Refrigerated Merchandisers

Autofill Wall Mount Boilers

User, Installation and Servicing Instructions. Panther Hot Cupboards GB2, GB3, GBM2, GBM3, GX2, GX3, GM2, GM3 IS70 ECN 1755

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages.

EcoSmart boiler SERVICE MANUAL

Autofill Wall Mount Boilers

Ecoboiler SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

CONTENT PAGE INFORMATION INSTALLATION BREWER SETUP BREWING CLEANING KEY BREWER GRINDER MANUAL MODE DILUTION GRINDER MODE PACKS MODE

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

Autofill Countertop Boilers

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

User Instruction Manual

Zen Boiling Tap Range

Thermostatic Concealed Shower Valve

Fitting Instructions and User Guide

T5 ( ) T10 ( ) PB5 ( ) PB10

UNDERCOUNTER SERVICE MANUAL. Ecoboiler UC4L 2.4kW Ecoboiler UC10L 2.8kW Ecoboiler UC10L 5.6kW Ecosmart UC4L 2.

SUPREME 140, 155, 170

4L Instant Water Boiler Instructions for Use

Actual product may differ from the one illustrated

Hot Chocolate Dispenser

Unvented Electric Water Heater 10/15 litre Undersink

OG7302 Salamander Grill

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

ELECTRIC WATER BOILER

INSTANTANEOUS ELECTRIC SHOWER

Zip Hydroboil. Instant boiling water. Installation and Operating Instructions

Mira Advance THERMOSTATIC ELECTRIC SHOWER. 8.7 and 9.8 kw. These instructions must be left with the user. User Guide W5-A

W Steam Iron User Instructions SHIR01

SAFETY AND OPERATING MANUAL. Original instructions 2000W WALLPAPER STRIPPER

User, Installation and Servicing Instructions. Silverlink 600 Gas Griddles GS4 and GS7 IS212 ECN3592

The Classeq under counter range

User, Installation and Servicing Instructions. Opus 700 Gas Griddle OG7201, OG7202, OG7203, OG7204, OG7207, OG7208 IS349 ECN3592

User Guide. Please read carefully before use. Your Hoover Guarantee. Your Hoover Guarantee. Contents. IMPORTANT Safety Reminders

Installation & Operators Manual. The Classeq Pass Through Range

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

EDEN. Installation Instructions. Bath shower manual mixer tap INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

User, Installation, Servicing and Conversion Instructions. Opus 700 Gas Oven Ranges OG7001 & OG7002 IS431 ECN3592

Marco Beverage Systems Ltd.

Zip Hydroboil. Instant boiling water. Installation and Operating Instructions

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Calomax Limited Lupton Avenue, Leeds LS9 7DD Tel Fax

BRITA Filter Jug Kettle

stainless steel jug kettle

KETTLE INSTRUCTION MANUAL

INSTRUCTIONS AND WARRANTY

SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

Transcription:

Installation, Operating and Servicing Instructions Wall Mounted Water Boiler WMB3F/B,WMB3F/W Please make a note of your product details for future use: Date Purchased: Model Number: Serial Number: Dealer: IS 435 ECN 3607 Page 1 of 12

CONTENTS Important Information 2 Warnings and Precautions 3 Technical Data 3 Checklist of Enclosures 3 Installation and Commissioning 3-5 Operating Instructions 5-8 Cleaning 8-9 Servicing, Maintenance and Component Replacement 10 Fault Finding 10 Spare Parts List 11 Accessories 11 Service Information and Guarantee 12 IMPORTANT INFORMATION Read these instructions carefully before using this product, paying particular attention to all sections that carry warning symbols, caution symbols and notices. Ensure that these are understood at all times. WARNING! This symbol is used whenever there is a risk of personal injury. CAUTION! This symbol is used whenever there is a risk of damaging your Lincat product. NOTE: This symbol is used to provide additional information, hints and tips. KEEP THIS MANUAL FOR FUTURE REFERENCE IS 435 ECN 3607 Page 2 of 12

WARNINGS AND PRECAUTIONS This appliance must be installed, commissioned and serviced by a qualified person in accordance with national and local regulations in force in the country of installation. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person. Ensure that the plug/socket is accessible at all times. Strip plastic coating and clean the appliance before use. During operation parts may become hot - avoid accidental contact. Disconnect this appliance before servicing, maintenance or cleaning. This appliance is not suitable for outdoor use. TECHNICAL DATA Model Height (mm) Width (mm) Depth (mm) Weight (kg) WMB3F/B WMB3F/W 415 300 185 8.5 CHECK LIST OF ENCLOSURES Warranty card Instructions manual 44mm diameter rubber grommet IS436 mounting template INSTALLATION AND COMMISSIONING This appliance must be earthed. An equipotential bonding terminal is provided to allow cross bonding with other equipment. No supply cable or connection hose is supplied with this appliance. IS 435 ECN 3607 Page 3 of 12

If replacing the plug connect the terminals as follows: Green and Yellow wire Earth E Blue wire Neutral N Brown wire Live L Means of isolation with at least 3mm contact separation in all poles must be incorporated into the fixed wiring of this appliance. The fixed wiring insulation must be protected by insulated sleeving having a temperature rating of at least 60 Deg C. Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57) Do not re-use old hose sets. Wall installation The boiler must be installed on a vertical concrete/brick wall with the base in a horizontal position. The location must be frost free. Using the template IS436 provided, mark the position of the mounting holes. Drill the holes and insert suitable wall plugs. Remove the glass front /outer body of the boiler by firstly removing the tap, circlip and nut. Remove the screw holding the lower centre trim and remove the centre trim. Finally remove the screw in the top front of the lid and then slide the glass and body assembly up and lift away from the appliance. Secure the boiler to the wall using 5mm (10g) screws. Electrical installation The appliance is supplied with a terminal block suitable for flexible wires up to 6mm 2. Cables may either be threaded through the cut out in the back panel, or via a 20mm diameter glanded bush in the base after removing the smaller knock out panel (Fig 1 B). Connection sequence is: E Earth Green/Yellow Right terminal N Neutral Live Centre terminal L Live Brown Left terminal Power Ratings Model kw Amps WMB3F/B WMB3F/W 3.0 13.0 IS 435 ECN 3607 Page 4 of 12

Water Installation Connection hoses may either be fed through the cutout in the back panel or via the larger of the two knock out panels (Fig 1 A). A blank rubber grommet is supplied and should be cut to fit around the feed pipe and fitted into the appliance base to seal it. The inlet connection point on the inlet solenoid valve is ¾ BSP and should be connected to the mains water supply via an accessible isolating tap. Connect the condensate/overflow pipe (Fig 1 F) to a suitable drain, considering any applicable local water regulations. If required, the internal pipe may be disconnected from the external connector and the pipe extended to pass through the cutout in the back panel and connected to a suitable drain. Ambient temp Deg C Water inlet pressure Bar Water inlet pressure kpa 5 to 30 1 to 8 100 to 800 Turn on the water supply and check for leaks before refitting the outer cover in a reversal of the removal procedure. OPERATING INSTRUCTIONS Only qualified or trained personnel should use this appliance. First Use Switch on both mains water and electricity supplies and leave the boiler for 15 minutes to fill completely. Drain off approximately 3 litres of water to remove any loose carbon particles from the filter. Regular operation The appliance starts automatically shortly after the electrical supply is turned on, filling with water and heating. To ensure that water is always hot, only small quantities are added constantly during the heating cycle. The appliance is designed to be left on permanently, only to be turned off for descaling or maintenance. IS 435 ECN 3607 Page 5 of 12

Adjustment - water temperature, screen backlight and contrast. Fig 1 Consult Fig 1. Turn power off at the mains for 5 seconds and then back on again. When the Filterflow screen is displayed, press and hold the power button (D) until the IS 435 ECN 3607 Page 6 of 12

software version is displayed. Press the function button Fn (E) and the temperature will be displayed. Press the power button to cycle through the values 70 to 96 Deg C. Press the Fn button to select the required value. The backlight adjustment screen is displayed next. Press the power button to cycle through the values 1 to 25. Press the Fn button to select the required value. The contrast adjustment screen is displayed next. Press the power button to cycle through the values 35 to 60. Press the Fn button to select the required value. Press the power button to exit. Standby If the appliance is to be left unused for any length of time, turn the element off by pressing the power button. Filter replacement The filter display shows the estimated life left in the filter cartridge (Fig 2). A reminder message is displayed when the filter needs changing. The boiler can be used without a filter but scale will quickly build up and water taste may be affected. FILTER READY CHANGE FILTER STANDBY CLEAR Fig 2 To replace the filter Twist the base of the filter 90 degrees to the left and carefully lower the filter cartridge out of the appliance. It will contain a small volume of water. Remove the black cap and place it on the new filter. Re-insert the filter into the recess and lock into place by twisting to the right. Press and hold the Fn button for 5 seconds to reset the filter life. IS 435 ECN 3607 Page 7 of 12

Drain off approximately 3 litres of water to remove any loose carbon particles from the filter. CLEANING Do not use a water jet or steam cleaner, and do not immerse this appliance. Clean all panels with warm water and mild detergent, do not use abrasive materials. Dry with a soft cloth. Wipe the dispensing nozzle daily to remove limescale deposits. De-scaling The boiler should be de-scaled regularly to maintain efficient operation and water quality. The frequency depends on the hardness of the water and the timely replacement of the filter. The de-scaling procedure must be performed by trained personnel as it requires the removal of panels from the boiler giving access to live electrical components. De-scaling the boiler at the end of the working day gives the de-scaling agent several hours to work. Lincat recommend our own de-scaling agent MS19, available from our Spares department. Wear protective clothing. Isolate the boiler from the electrical supply. Turn off the power and allow the water to cool to 60 Deg C. Using a 3mm Allen key, remove the screw in the top of the boiler and remove the boiler outer body. Remove the insulation from the top of the tank, then unscrew and remove the tank lid. Add the de-scaling agent slowly to avoid eruption of the water. Follow the manufacturer s instructions. Replace the tank lid and outer body. Attach an Out of Use notice to the boiler to prevent use during de-scaling. Turn on the electricity and allow the boiler to run normally for 30 minutes. Isolate the boiler and allow the water to cool. Remove the outer body and tank lid and inspect the tank and level sensor housings for scale deposits. If necessary, repeat the de-scaling process. IS 435 ECN 3607 Page 8 of 12

Drain and flush all de-scaling agent from the tank completely as follows: Unscrew the drain plug (beneath the grommet Fig 1 G) using a 24mm spanner to hold the plug and a 21mm socket on a ratchet (Fig 3) to remove it from the bottom of the tank. Drain all the water out. Fig 3 Flush out the tank with clean water. When empty, replace the drain plug and replace the grommet. Replace the tank lid, ensuring the gasket seals the top of the tank correctly. Refit the outer cover and turn the boiler on. IS 435 ECN 3607 Page 9 of 12

SERVICING, MAINTENANCE AND COMPONENT REPLACEMENT All servicing, maintenance and component replacement on this appliance should be carried out by one of our recommended service engineers. FAULT FINDING The control panel displays information that can help with fault diagnosis. Before calling for service, draw off a litre of water, clear the fault code by pressing the Fn button and turn the boiler off and on again at the supply. If the fault persists, call service for advice. Message displayed Possible causes Corrective action FILTER STANDBY FILTER STANDBY FILTER STANDBY FILTER STANDBY CAUTION SEE MANUAL FAULT SEE MANUAL DESCALE CLEAR NO WATER CLEAR NOT HEATING FAULT SEE MANUAL CLEAR THERMISTOR FAULT SEE MANUAL Scale on level sensors Boiler overfilling Water turned off Inlet hose kinked or blocked Water pressure too high or low Drain valve open Boil dry/overheat protector tripped Temperature sensor fault Element failed PCB fault Faulty or loose connection Temperature sensor fault Descale Check water inlet valve Check water supply and drain valve Call service if fault persists Call service IS 435 ECN 3607 Page 10 of 12

SPARE PARTS LIST Part Number Description Used on CO252 Compression stop end EL277 Element FH02 Filter head only WMB3F/B, WMB3F/W GA56 Tank gasket GF01 Glass front WMB3F/B GF02 Glass front WMB3F/W LE47 Level sensor insulator LE48 Upper level sensor LE51 Lower level sensor PR73 Circuit board SI01 Sensor isolator SL20 Tap nut SL21 Tap circlip SL34 Tap body WMB3F/B, WMB3F/W SO24 Solenoid SW88 Momentary switch TE40 Terminal block TH87 95 Deg cutout TH88 120 Deg cutout TH98 Thermistor ACCESSORIES DR72 FC02 MS19 Part Number Drip tray Filter cartridge De-scaler Description IS 435 ECN 3607 Page 11 of 12

SERVICE INFORMATION For help with the installation, maintenance and use of your Lincat equipment, please contact our service department: UK: 01522 875520 For non-uk customers, please contact your local Lincat dealer All service work, other than routine cleaning should be carried out by one of our authorised service agents. We cannot accept responsibility for work carried out by other persons. To ensure your service enquiry is handled as efficiently as possible, please tell us: Brief details of the problem Product code Type number Serial number All available on serial plate Lincat reserve the right to carry out any work under warranty, given reasonable access to the appliance, during normal working hours, Monday to Friday, 08:30 to 17:00. GUARANTEE This unit carries a comprehensive UK mainland 2 year warranty. The guarantee is in addition to, and does not diminish your statutory or legal rights. The guarantee does not cover: Accidental damage, misuse or use not in accordance with the manufacturer s instructions Consumable items (such as filters, glass, bulbs, slot toaster elements and door seals.) Damage due to incorrect installation, modification, unauthorised service work or damage due to scale, food debris build-up, etc. The manufacturer disclaims any liability for incidental, or consequential damages. Attendance is based on reasonable access to the appliance to allow the authorised technician to carry out the warranty work. Service calls to equipment under warranty will be carried out in accordance with the conditions of sale. Unless otherwise specified, a maximum of 15 minutes of administrative time, not spent directly carrying out servicing work, is provided for within the warranty. Any requirement for staff attending the call to spend greater time than 15 minutes due to administrative requirements, such as on health and safety risk assessments, will be chargeable at the prevailing rate. IS 435 ECN 3607 Page 12 of 12