FOREFRONT AT THE OF PROTECTION

Similar documents
w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

automatic FiReFighTing SYSTeMS in PainT booths

AUTOMATIC FIREFIGHTING SYSTEMS IN HOSPITALS

AUTOMATIC FIREFIGHTING SYSTEMS IN KITCHENS

THE IDEAL SOLUTION FOR KITCHENS

SAFETY THE BEST FOR YOUR EQUIPMENT

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

What is HI-FOG? The natural enemy of fire

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

PROTECCIÓN DE RIESGOS ESPECIALES AUTOMATIC FIREFIGHTING SYSTEMS IN VEHICLES. con tubo de detección

Fire protection for buildings

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

PHIREX AUSTRALIA. FOGEX & MISTEX WATER MIST FIRE PROTECTION

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen

Performance Based Fire Protection With Water Mist

Case study: EconAqua water mist sprinkler system

WATER MIST CONVENTION AND EXHIBITION

Water Mist Fire Suppression

FIGHTING FIRE as easy as blowing out a match

Identify RISKS. Design SOLUTIONS. Prevent DISASTERS

Approved products and systems for water mist systems and VdS 3188 for planning and installation

The History of IWMA. 18th International Water Mist Conference will (IWMC) take place in London on 19th & 20th September 2018

PREVENT SYSTEMS WHEN SAFETY IS TAKEN SERIOUSLY

MORE THAN JUST FIRE PROTECTION

GAS EXTINGUISHING SYSTEM INERT GAS. Argotec with carbon dioxide. Safe for certain.

Nessie High Pressure Water Mist Components for Fire Fighting

Fire Protection of Hotels. With SEM-SAFE High-Pressure Water Mist System

Water Mist System. Principle of Water mist evolves from combination of 3 main effects:

PHIREX AUSTRALIA CATALOGUE & DATA SHEETS. April 2005, Rev 2. Fogex Water Mist Fire Protection System Components PHX-3064

MORE THAN JUST FIRE PROTECTION

Carbon Dioxide Extinguishing Systems Fighting fire with CO2

Watermist Applications and Approvals

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

CO2 COCO GAS FLOODING SYSTEM

Fire suppression systems for server rooms and data centres

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen

Control and extinguishing by water mist

High-Pressure Water Mist systems for the protection of shopping centres in historical city centres

CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML

Low Pressure INNOVATIVE FIRE PROTECTION SOLUTIONS in the. Woodworking Industry INNOVATIVE FIRE PROTECTION. VID Fire-Kill. Denmark.

What extinguishes fires without pressure peaks?

Report on First Revision June 2014 NFPA 5000

ODS & SGG Alternatives for the Fire Protection Industry 2018

BOC FS125 The Fire Extinguishing Solution

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems

Welcome to Argonite fire protection from Ginge-Kerr

An Overview of Extinguishing Systems for Computer Equipment

WAS STARTED BY CARLOS BAHAMONDES MASAFIERRO

Watermist Fire Protection of Plant Rooms

Proven Fire Fighting Efficiency for Large Transformers with High Pressure Water Mist

CERTIFICATE OF FIRE APPROVAL

LPG ProteK. for commercial kitchens

KD Innovative extinguishing with Novec TM 1230 by 3M TM

Tudor House, Kingsway Business Park Oldfield Road, Hampton, Middlesex, TW12 2HD Phone: +44 (0) Website:

VELMIST. System Mgły Wodnej Niskociśnieniowej

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

Element C3.4 Fire Fighting Equipment

FIRE SUPPRESSION SYSTEM

CO 2 Fire Extinguishing Systems

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

Press Presse Press Presse

Safe, Effective, Environment-friendly

Fire Suppression Systems

Application of BS 8489 to the Protection of Generator Enclosures. IWMA, BRE 22 nd March 2017 Dr Tim Nichols CPhys FIFireE

Water mist fire suppression systems. Minifog EconAqua Water mist sprinkler systems

NOTHING BURNS BRIGHTER THAN OUR COMMITMENT TO MEETING YOUR NEEDS.

Jonathan Redding Area Sales Manager FOGTEC Fire Protection Cologne, Germany

Installation and Maintenance Requirements

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

High flying fire protection HI-FOG for aircraft hangars

STANDARDS FOR ACTIVE FIRE PROTECTION. Stewart Kidd Loss Prevention Consultancy Ltd

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS)

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

XC10 combined fire detection and extinguishing control

Our Mission. About Us. To create awareness of the essentiality attached to a firefighting system, as an important requisite in everyday life and loss

WATER SPRAY EXTINGUISHING SYSTEMS

Fire fighting excellence. HI-FOG water mist fire protection

Fire fighting excellence. HI-FOG water mist fire protection

FIRE STOP 200/30. High technology system for first attack of fire with high pressure nebulized water (Water mist) FD 907. Ed.

Water Mist and Heritage Buildings Case - St. Mark s Dome, Venice

Update on European Standardization Work

An experimental study of the impact of tunnel suppression on tunnel ventilation

Development and Full-Scale Tests of a Water Mist System inside High Speed Trains

Fire protection solutions for ships and offshore facilities

Deluge & Preac tion Systems

How can you minimize consequential damages in case of a fire?

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.

High pressure water mist sprinkler system for fighting fires

FIRE PROTECTION, NATURALLY AQUASONIC Water-Atomizing Fire Suppression System

Shalaby Institute of Fire Protection Heyrothsberge, Germany.

Water Mist v Sprinklers

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017

ISO INTERNATIONAL STANDARD. Ships and marine technology Fire-extinguishing systems for protection of galley cooking equipment

PAFSS Fire Suppression Systems from Jactone. Automatic Fixed Fire Suppression Systems. JACTONE.COM/PAFSS +44 (0)

3M Novec Fire Protection Fluid

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT

Transcription:

AT THE FOREFRONT OF PROTECTION SIEX WF B combines the benefits of water as an extinguishing agent with the most innovative advances to achieve fire protection causing the least possible damage and exceeding the highest expectations. The basic aim is to achieve the highest efficiency in fire protection while ensuring responsible and sustainable use of water. The SIEX water mist range includes units specially designed for each specific protection need. They adapt to the requirements for the control, suppression or extinguishing of fire, addressing any specific project limitations.

The CYLINDER BANKS store the extinguishing agent and propel it using pressurized nitrogen. Within the same assembly, some cylinders store water and other auxiliary cylinders store the propellant. It improves on traditional sprinkler systems, suitable for more applications, many of them with special features. In addition, the resumption of activity after discharge is much less expensive and faster thanks to the minimal impact involved, since the damage caused by water, smoke and fire is minimal. SIEX, aware of current fire protection needs, has developed (through its R&D and innovation department) a technology that exceeds the traditional extinguishing methods and water mist systems available on the market. By spraying this substance in such small particles, the environment is cooled significantly without damaging the equipment. Likewise, the high-velocity discharge reaches the seat of the fire more effectively. IT ENSURES MORE EFFICIENT COVERAGE OF HAZARDS PREVIOUSLY PROTECTED BY SPRINKLERS. IT CAN ALSO BE INSTALLED IN OTHER HAZARDS WITH MORE SPECIFIC FEATURES SUCH AS ESCALATORS, ELECTRICAL TRANSFORMERS, ETC.

Purpose of water mist systems Fire control Fire suppression Fire extinguishing Limiting the growth of the fire until manual extinguishing intervention. Extended discharge. Sharp reduction in the rate of heat emitted by the fire during the discharge time. Complete extinguishing of the fire and danger of reignition with reduced discharges.

tests, approvals and certificates Our equipment has obtained the major international certificates issued by the most prestigious agencies in its field: VdS, FM*, Lloyd s Register, DNV and Bureau Veritas. We have done so by testing all our products in internationally recognized laboratories such as VTT and SINTEF, thus objectively demonstrating the quality of our water mist systems. They are approved according to the IMO MSC/Circ. 913 standard in marine systems, for use in local application and approval for use in public spaces, storage areas, cabins and corridors, as per IMO Resol. A.800 and IMO MSC.265 (84). It is also approved as per the MSC/Circ. 1165 for machinery spaces. It is also approved for land systems for use in public spaces (apartments, banks, schools, conference rooms, stations, churches, prisons, etc.), offices and cable tunnels according to standard and technical specification CEN TS 14972, and certified by VdS. The components have been approved by the VdS and CO MSC/ Cir. 1165 directives. The SIEX water mist system has also been successfully tested for use in SINTEF-equipped tunnels. Our company is also ISO 9001:2000 and ISO 14001:2004 certified for Quality and the Environment. SIEX CONSTANTLY UNDERTAKES TO OBTAIN CERTIFICATIONS THAT MEET GROWING MARKET DEMANDS, OFFERING OUR CUS- TOMERS THE MOST COMPETITIVE PRODUCTS AND ENSURING MAXIMUM EFFICIENCY. IMO MSC/Circ. 1165 IMO MSC.265(84) IMO MSC/Circ. 913 IMO Resol. A.800 CEN 14972 VdS / FM* ISO 9001:2000 ISO 14001:2004 (*FM IN PROCESS)

CYLINDER CYLINDER BANK SIEX WF B with CYLINDER storage is the best option when water demand does not exceed 850 litres. We have a variety of cylinder sizes to optimize the assembly, depending on the hydraulic calculation. All cylinders feature an internal anti-corrosion treatment. Like all our systems, every component is manufactured to the highest quality standards and European directives. To protect small enclosures or hazards, a modular unit can be used where the cylinder is already pressurized with nitrogen and requires minimal storage space. Cylinder banks can protect larger areas. For these systems, we use only cylinders charged only with nitrogen at 200 bar, pressurizing the water cylinders. One gas cylinder is required for the discharge of three water cylinders of equal size. A nitrogen-charged pilot cylinder can be included for activating the entire system. A retarder can be connected to this component in order to facilitate personnel evacuation.

NOZZLES Designed using the latest technology for creating and spraying micro droplets, our nozzles are a critical system component. Specifically designed for each hazard (previously analyzed in-depth and comprehensively), they are checked and certified according to various tests performed in Europe s most prestigious certification laboratories, according to the most demanding and stringent guidelines. They can be adapted to both total flooding and local application, and installation can involve either open or closed nozzles. These spray nozzles are approved for a wide variety of hazards, designed specifically for each type of application. For this reason there are different models with different flow rates, coverage angles and installation heights, depending on what needs to be protected. The nozzles ensure a proper and homogeneous distribution of the water mist discharge. This is achieved thanks to the effect of pressure and the break up of water into micro-droplets, ensuring optimal spraying for controlling, suppressing or extinguishing every type of fire, resulting from extensive and deep in-depth research rch and development.

ACTIVATION METHOD Depending on the application to be protected, SIEX designs its equipment for dry pipe, preaction or wet pipe systems. DRY PIPE systems are those which are empty of water prior to detection and activation. They are installed with OPEN NOZZLES. This mechanism can also be installed with CLOSED NOZZLES, in which case it becomes a PREACTION SYSTEM. The pipe is filled with water after fire detection, but the nozzle discharges only when the temperature increases (as a result of the fire) and the heat-sensitive bulb of the spray nozzle breaks. This prevents false alarms and water mist is discharged only in the fire-affected area. In WET PIPE SYSTEMS, the pipework is always charged with water pressurized at the pilot pressure, which is discharged when the heat-sensitive bulb breaks.

WHAT ARE THE OPERATING PRINCIPLES OF THE EXTINGUISHING AGENT? The key principle of fire suppression with water mist is COOLING, drastically reducing the fire heat. The smaller droplet size, compared to traditional equipment, results in a larger exchange surface, which enhances the absorption of heat energy and generates greater amounts of vapour, which results in an additional effect of OXYGEN DISPLACEMENT. RADIATION ATTENUATION also takes place, as the spread of fire to other areas is limited and fire is prevented from spreading to intact combustible areas. This mechanism itself is not an extinguishing element, but it is essential for preventing the fire from spreading.

APPLICATIONS for total flooding Archives and libraries Computer Rooms Offices Warehouses and factories Shopping centres Hospitals Hotels and schools Telecommunication systems

for local application Cable ducts Transformers and turbines Paint booths Escalators Kitchen hoods Wind turbines

BENEFITS OF THE SYSTEM The reason why water mist is becoming so widely used is the system s features, which make it the best solution for many different types of applications of varying sizes. On many other occasions, it is the only technically feasible solution due to its adaptability. Also stands out from sprinklers: ENVIRONMENTAL COMMITMENT. It uses up to ten times less water. Energy consumption is zero because water mist is discharged by means of pressurized inert gas. EASY TO INSTALL. Thanks to the optimized use of water, smaller-diameter pipes are used. Installation is faster and more reliable because pipes can be bent.

HIGH SUPPRESSION AND EXTINGUISHING POWER. LOCAL APPLICATIONS The specific surface area of water mist systems is much greater than traditional sprinkler systems. Due to the greater active surface area, the exchange of fire heat is also higher. The design of our nozzles allows water mist discharge to focus on a specific hazard, achieving optimum extinguishing efficiency at a lower cost compared to other total flooding systems. SPECIAL APPLICATIONS SYSTEM APPEARANCE Water mist systems are flexible enough to be used for hazards with unique configurations such as: escalators, robotic parking garages, etc. beyond the protection scope of traditional systems. In systems where piping is visible, the small and stainless steel pipe used has no adverse impact on the appearance of the area. Fewer nozzles are required to cover the same hazards. LESS DAMAGE TO EQUIPMENT HARMLESS TO HUMANS It reduces losses in materials exposed to the hazard, since the system involves no water soaking, unlike sprinklers, and it drags down smoke produced by the fire. It is specially designed for occupied areas. Although the mist produced after discharge is intense, people can still breathe normally and evacuate the enclosure safely.

SIEX C. Merindad de Montija nº 6 P.I. Villalonquéjar 09001 Burgos (SPAIN) TLFNO: +34 947 28 11 08 WEB: WWW.SIEX2001.COM SIEX es una marca registrada. La documentación descrita en este documento es únicamente orientativa. Para la instalación de todos los sistemas SIEX, debe recurrirse a la información técnica. SIEX no se hace responsable de la utilización que terceros puedan dar a esta información. SIEX se reserva el derecho a realizar cualquier cambio tanto en las capacidades como en las características de sus equipos