PORTABLE DEW POINT MONITOR

Similar documents
HIGH RANGE DIGITAL DEW POINT METER & MONITOR Model #8074 IMS # (TED1-8074)

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

Cool IR. Model C104 - Cooling System. Instruction Manual

MODEL 321/421 NUCLEAR POWER PLANT TRITIUM MONITOR

Heatless Desiccant Compressed Air Dryers

25M01A-100 to 25M01A-199 HSI Single Stage Combination Gas Valve

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

MODEL 421 NUCLEAR POWER PLANT TRITIUM MONITOR

PMT200A SERIES DEHYDRATOR USER MANUAL. Bulletin AE01B-A NOV 05

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

Model OP155 Air Dryer

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

TROUBLESHOOTING GENERAL TROUBLESHOOTING PROBLEM PROBABLE CAUSE CORRECTIVE ACTION

Model 1820 Dehumidifier

Desiccant Drying DRYPOINT XC. efficient low dew point heatless desiccant drying. Truth in Compressed Air.

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

ARES-G2 Rheometer. Site Preparation Guide. Revision A Issued June 2016 Page 1

RLD-H10P Refrigerant Leak Detector

Truck Edition V-220 / V-320 Series Single Temperature Systems TK IM (Rev. 0, 06/17)

MODEL DPS1 Heated Dew Point Measuring System OPERATORS MANUAL

Enclosed Scroll Air Compressor System SES 3-5 HP

SIEMENS SIMATIC HMI TOUCH SCREEN BLOWER PURGE DESICCANT AIR DRYER HMI USER MANUAL V4

Refrigerated Air Dryers

High Output Vacuum/Pressure Pump

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS

Using the Model 1500 Portable Chilled Mirror Hygrometer

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02

TK-5001, Pneumatic Room Thermostats General Instructions GENERAL INFORMATION INSTALLATION

LD920. User Manual. H2/N2 Tracer Gas Leak Detector. Detects 5% H2 in 95% Nitrogen Tracer Gas. Made in U.S.A. LeakDetectors-LD920-UserManual.

RLD-H10G Refrigerant Leak Detectors

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

INSTALLATION INSTRUCTIONS

Standard SPECIFICATIONS FEATURES APPLICATIONS

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

RKA-LEL Sample Draw Combustible Gas Detector

SECTION METERS AND GAGES FOR HVAC PIPING

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

Catalog 9CW-SD-9 Manual Desiccant Dryers Models X0, X0, X0 and X5 Wilkerson's Manual Desiccant Dryers offer the most cost effective method to remove m

Site Specifications for the. INDUSTREX M37 Plus NDT Filmprocessor

MODEL URS-1: FACTORY RETROFIT PROGRAM

DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS

This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified.

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

16. Hose Replacement. Disconnect power supply to the AR400.

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

Membrane Drying DRYPOINT MD. space saving compressed air membrane dryers. Truth in Compressed Air.

Heat Exchanger Block Replacement Instructions

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Norcold Repair Guide for Ice Maker

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

GETZ MANUFACTURING PART NO.: MODEL: SV1 100 PR VACUFILL SYSTEM (Revised 6/7/05)

Caresaver Universal Refrigerant Recovery Unit

FCT-CE SERIES ELECTRIC TILTING KETTLE W/HAND CRANK PARTS AND SERVICE MANUAL

User s Information/Installation Instructions

Hydrogen Generator Model HPNM 1. Instruction manual. 166 Keystone Drive Montgomeryville, PA Phone: Fax:

Air. Pressure. Motion. nnnnnnnn

GETZ EQUIPMENT INNOVATORS PART NO.: 9G58619 MODEL: SV1 150 PR VACUFILL SYSTEM (Revised 2/25/14)

Tank, Heater, and Control Operation Manual REV. E DATE: 04May2015

ECS Pre-Engineered Nitrogen Generator. ECS Pre-Engineered Wall Mount Nitrogen Generator PGEN-10/(PGEN-10E)

UA Series Air Dryers. 10 Year Warranty Limited ( SCFM) Setting a new standard in Quality and Reliability WAS 360

PINNACLE WAREWASH CONTROL By DEMA DP-812-DL-1T DP-813-DLL-1T DP-812-LL-1T DP-813-LLL-1T Introduction

15R HARDWARE INSTALLATION GUIDE

Visit us at testo 835 Infrared and contact thermometer

1.2.3 Returning Instrument for Repair.

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

Hoshizaki America, Inc.

Product Data Sheet Adsorption Dryer DPS (A)

SAHARA SERIES DryLine DEHYDRATOR USER MANUAL

SAHARA2A-HP SERIES DryLine DEHYDRATOR USER MANUAL

Waveguide Dehydrators

Apex E Quick Installation Guide

Dissolved Oxygen Sensors

Moduflex. Desiccant Air Dryer P3TJA13A1AN - P3TJA13A7AN. USER GUIDE (Original Language) Dry Air System NL DE FR FI SV NO DA EL ES PT IT PL SK CS ET HU

ASTRO EXPRESS 2 HOT WATER DELIVERY SYSTEM

FOT-100. Fiber Optic Temperature Sensor User s Manual P/N: I3A-110

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

ECS Pre-Engineered Nitrogen Generator. ECS Pre-Engineered Wall Mount Nitrogen Generator PGEN-3/(PGEN-3E) PGEN-5/(PGEN-5E)

Thermo Scientific Air Cadet

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Model 1870F Dehumidifier Installation and Operating Manual

Liquid Helium Level Instruments

R11B EN. Operating Manual English. RackCDU (InRackCDU) Operating Manual. History: Date: Notes: Revision: 21-Dec First Release 1.

Hoshizaki America, Inc.

347002K/177002K/34900

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Isco 3700ZR Sampler. Manual Set

CA5000 Liquid CO 2 Freezer Backup System

DHR Accessories Requirements. Site Preparation Guide

MANUAL CONTROL HEATING, VENTILATION, AND AIR CONDITIONING SYSTEM

SERVICE MANUAL FOR MODEL RM-10

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

Transcription:

PORTABLE DEW POINT MONITOR MODEL 8072, 8072-230VAC (units made after 2002) Table of Contents INTRODUCTION... 2 SPECIFICATIONS:... 2 OPERATION... 3 Dryer Output Sampling... 3 Hopper Output Sampling... 3 Recorder Output Connection... 4 CALIBRATION & MAINTENANCE... 4 Dry-Down Test... 4 Replacement Parts... 4 Alarm Set Point Adjustment... 5 F to C Display Change... 6 Sensor Replacement Procedure... 6 Electronic Test Procedure... 6 ADDENDUM Wiring Diagram Drawing No. 6392NWD Assembly Drawing No. 8072ASSY PLASTIC PROCESS EQUIPMENT, INC. 8303 CORPORATE PARK DRIVE MACEDONIA, OHIO 44056 PHONE: (800) 362-0706 FAX: (800) 223-8305 MANUAL/8072PPE_E February 2011

INTRODUCTION The 8072 Dew Point Monitor is ideal for checking the operation of a dryer or confirming the dryness of plastic resin in a hopper. The monitor draws process air from the dryer or hopper into an internal manifold containing a sensor which provides dew point measurement. SPECIFICATIONS: Dew Point Range -40 F to +15 F (-40 C to -9 C) Sensor Part # Accuracy Alarm Set Point Recorder Output 1205DM ±3 F -10 F (-23 C) Adjustable 4-20mA scaled as -40 F to +70 F (0-5V optional) ma = DP + 67.5 or V = DP + 40 6.875 22-40 F = 4mA or 0V 70 F = 20mA or 5V Indicators Power Requirements Power Consumption Pump Specifications Dimensions Weight GREEN LIGHT during "dry" condition RED LIGHT and BEEPER during high dew point 115VAC +10% (230VAC optional) 50/60Hz 5 Watts Flow: 2.5 L/min (0.08 SCFM) Vacuum: 6.8" of Hg Pressure: 3.2 psi (All pump specifications are nominal) 8072 Carrying Case - 9" x 12-1/2" x 5" Deep 8 lbs. shipping 2

OPERATION The 8072 is designed to sample process air at a pressure between -1 psig and +7psig. This range of air pressure is typical of that found in a plastics drying system. If you are sampling compressed air, consult factory for other model options. The plastic tubing supplied with this monitor can withstand temperatures up to 275ºF. Higher temperature air can be cooled to a safe level by sampling through a short length of copper tubing. Older models with built-in copper cooling coils are supplied with clear PVC tubing. This tubing should be limited to 180ºF. NOTE: For best sensor life and response time, avoid sampling ambient air of high humidity. Leave unit off when not monitoring a dryer or hopper. Some units have a brass selector valve on the side panel. This valve should remain closed during any operation to prevent ambient air from leaking into the sensor manifold. The 8072 is packaged for convenient spot checking of dryers or hopper systems, but it can be used continuously to monitor process conditions, with the beeper indicating excessive moisture. Dryer Output Sampling The performance of a dryer can be evaluated by measuring the dew point of its output air. 1. Connect the 8072 sample tubing to a point in the drier s output. Make sure not to exceed the supplied tubing temperature rating. 2. Turn on the 8072 and allow the reading to stabilize. It can take 10 minutes or more for the unit to stabilize when first used. You can silence the beeper with the switch on the side of the panel. A constant high reading on the 8072 may indicate a malfunctioning dryer or one that is overloaded by damp material in the hopper. Hopper Output Sampling Dryness of material in a hopper can be checked by measuring the dew point of air exiting the hopper. When a hopper is initially loaded with material, high dew points at the hopper air return are normal while moisture is removed. It can take significant time to dry material in some systems. 1. Connect the 8072 sample tubing to a point in the hopper s air output. Make sure not to exceed the supplied tubing temperature rating. 2. Turn on the 8072 and allow the reading to stabilize. Plastics processing can proceed when the dew point reading is low enough for your material. 3

Recorder Output Connection The 4-20mA output jack on the front panel allows continuous monitoring of dew point over a period of time. The supplied mating connector can be wired as needed. Pin 1: Pin 2: 4-20mA signal ground CALIBRATION & MAINTENANCE Dry-Down Test Verify the Dew Point Monitor's ability to read dry air by performing the following steps: Note: the supplied desiccant cartridge should be blue in color. After repeated use the desiccant will turn pink. The desiccant can be recharged by removing one end cap, emptying the contents into a Pyrex glass container, and baking at 350ºF or microwaving until blue. 1. Make sure the supplied desiccant cartridge is dry (contents should be blue in color). 2. Connect one end of the desiccant cartridge to the sample air inlet tubing and the other end to the pump vent tubing. 3. Turn the power on and allow 5-10 minutes for the reading to stabilize. A dry desiccant cartridge will produce a dew point of -20ºF to -40ºF. If Dew Point Monitor reading doesn't respond by indicating a low dew point, contact Plastic Process Equipment for factory service. Replacement Parts DTR-30...Desiccant Tube 1205DM...Hygrosensor 3305005... In-Line Air Filter 4

Alarm Set Point Adjustment The dew point at which an alarm occurs can be changed. The unit must be opened for this procedure so remove power before proceeding. Remove the four nuts and screws that hold the panel in the case. Remove the panel and look at the PC board. WARNING THE FOLLOWING PROCEDURE IS PERFORMED WITH POWER APPLIED. TO PREVENT SHOCK, DO NOT TOUCH ANY TERMINALS INSIDE THE DEW POINT MONITOR. Apply power to the unit and turn it on with care, making sure not to touch any electrical components inside. Locate the display function switch (S1) near the upper left corner of the PC board. Note that only one position of this switch should be ON at a time. Switch the OPER position of S1 to OFF and the SET1 position to ON. Adjust SET1 potentiometer to the desired alarm set-point as shown on the LED display. S1 setting for alarm set-point view and adjustment When finished adjusting the alarm set-point, return S1 to the default operating mode by switching OPER position ON and all others OFF as shown below: OPER SET1 SET2 OPER SET1 SET2 S1 S1 S1 setting for normal operation Remove power to the unit before assembling the panel back in its case. 5

F to C Display Change The unit must be opened for this procedure so remove power before proceeding. Remove the four nuts and screws that hold the panel in the case. Remove the panel and look at the PC board. To change the digital display to C, move jumpers J6, J7, and J8 (if present) to the C position. Sensor Replacement Procedure Replacement of the sensor is recommended on a yearly basis. Remove power to the Dew Point Monitor before servicing. 1. Remove the panel from instrument case. 2. Disconnect the sensor cable from the manifold. 3. Remove the hex nut and slide the sensor and socket out of the manifold. 4. Remove old sensor from socket and press the new sensor into the socket. Then slide the sensor and socket into the manifold. 5. Replace and hand-tighten the hex nut. 6. Install panel in instrument case. Electronic Test Procedure This procedure checks the operation of the circuit. Perform this procedure if display does not respond to the Dry-Down Test described earlier and if the electronics are suspect. WARNING THE FOLLOWING PROCEDURE IS PERFORMED WITH POWER APPLIED. TO PREVENT SHOCK, DO NOT TOUCH ANY TERMINALS INSIDE THE DEW POINT MONITOR. 1. Remove the panel from its case and disconnect the sensor cable from the sensor manifold. 2. Connect the dew point monitor to power and turn it on. With sensor cable disconnected, the dew point monitor should read -40 F +2 F. 3. Place a jumper across the sensor cable. The dew point monitor should read +15 F +2 F. If display fails to read these values, contact Plastic Process Equipment for factory service. 6