Installation and technical manual

Similar documents
gorenje GBFU SIMPLICITY

TECHNICAL PROPERTIES OF THE APPLIANCE

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

17 OPERATING AND INSTALLATION MANUAL - EN

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

Unvented Electric Water Heater 10/15 litre Undersink

Multipoint Technical Data

Flow Factor ~

GLASS HEATER OWNER S MANUAL. Model No. GH-15A

Installation guide COMBI. Before installing read this guide first

Kettle User Manual WKM6306W WKM6306B EN 01M M

Handyflow Undersink HF05MVC

IDNr.: KH /03. Kompernaß Handelsgesellschaft mbh Burgstraße 21 D Bochum UK

Operating instructions

V.lla Pro 5200 R - Cod. M0S Edizione 1H04

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

CSH COMBINED STORAGE HEATERS INSTALLATION INSTRUCTIONS AND USER GUIDE

CONTENTS QUICK REFERENCE GUIDE INSTRUCTIONS FOR USE PROGRAMME CHART BOOKLET

ZIP InLine. Models: ES3, ES4 & ES6. Electronic Instantaneous Water Heaters. ES3, ES4 & ES6 Instructions. V1.09 Page 1 November / 2015

Installation, operating and servicing instructions

Installer manual ELK 213 Immersion heater

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

Single Induction Hob

Instruction Manual. Orayonne. Glass radiation heater

Kettle User Manual WKD6306W WKD6306B EN 01M M

INSTALLATION AND OPERATION MANUAL

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

OPERATING AND INSTALLATION MANUAL

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

AC THOR. Assembly Instructions

KOSPEL S.A KOSZALIN UL. OLCHOWA 1

A few simple steps to ensure perfect water, every time.

HAVERLAND APP. The first self-programmable radiator and control from anywhere in the world INSTRUCTION MANUAL.

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

HEATED COUNTER. Operating Instructions

INDEX WARNINGS AND RECOMMENDATIONS 2 COMPLIANCE DECLARATIONS 3 RANGE AND SIZES 3 ELECTRICITY SUPPLY 3 INSTALLATION 4 INSTRUCTIONS FOR UNINSTALLING

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

Electronically controlled instantaneous water heater. DEX: C models. Instructions for the user

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

Safety and Instruction Manual

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

CONTENTS QUICK REFERENCE GUIDE PROGRAMME CHART

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

ELECTRIC CENTRAL HEATING FLOW BOILER

ЭКСПЛУАТАЦИЯ И МОНТАЖ ПРОТОЧНЫЕ ВОДОНАГРЕВАТЕЛИ С ЭЛЕКТРОННЫМ УПРАВЛЕНИЕМ

V 120 SG - V 160 SG. Instructions for use

Ice Maker. Pour la version française veuillez consulter notre site de web

AC500T, AC1000T, AC1500T, AC2000T

Compact Citrus Juicer

User Manual. Electric Heating Element MEG DRY MOA REG 2 REG 3

INSTANTANEOUS ELECTRIC SHOWER

NEXIUN ANALOGUE INERTIA RADIATOR, PROGRAMMABLE WITH PILOT WIRE INSTALLATION INSTRUCTIONS AND USER GUIDE NEX4PW NEX8PW NEX12PW NEX14PW

Deluxe Ice Crusher. Pour la version française veuillez consulter notre site de web

instructions OIL FILLED RADIATOR V V and V551225

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

Moisture inside the drum is due to final testing.

Moisture inside the drum is due to final testing.

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

INSTRUCTION MANUAL KETTLE

Steam Iron. Techne 500

INSTRUCTIONS AND WARRANTY

INSTALLATION MANUAL GUTHD2. Universal Two Way Digital Thermostatic Valve for Shower Systems

Installation and User Instructions HS10U, HS15U.

Safety and Instruction Manual

INSTRUCTIONS AND WARRANTY

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

EN Variable Temperature Electric Kettle

W Steam Iron User Instructions SHIR01

1.5L Fryer v1.0. Model: SD6060N. Helpline. SD6060N_IM.indd 1 07/10/ :58

Electric Milk Frother

600mm Electric Cooktop with Solid Elements

MHG201 Gas Hob Manual for Installation, Use and Maintenance

INSTALLATION AND MAINTENANCE MANUAL. Alcor FA

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

Apollo Kettle. Pour la version française veuillez consulter notre site de web

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

HOTFLO 10 / 15. Fitting Instructions and User Guide

DIGITAL MODULATING BOILERS

User Instruction Manual

AIR COOLER OPERATING INSTRUCTIONS MODEL NO: ARC-30 ARC-30. Instruction Manual

HOTFLO 10 / 15. Fitting Instructions and User Guide

Steam Station User Manual

kW kW kW kW

Hedge Trimmer. Please read the manual fully before using the appliance and keep the manual safe for future reference.

OPERATING AND INSTALLATION MANUAL

Streamline Undersink. Fitting Instructions and User Guide

Lumiglo Fast Boil Kettle

OPERATING and INSTALLATION MANUAL

Installation and technical manual

1.0 INTRODUCTION 3 TABLE OF CONTENTS 2.0 FOR YOUR SAFETY Warnings and Safety Advice Coolants WARRANTY AND 3 CUSTOMER SERVICE 4.0 INS

Safety and Instruction Manual

Transcription:

Installation and technical manual KSU 2005/3010 KSO 2005/3010 D THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.BE SURE TO OBSERVE ALL LABELS AND WARNINGS ON THE APPLIANCE. Edition:07/16 Id_Nr. 900 350 190

1. Safety Information The appliance may be used by children older than 8 years old, elderly persons and persons with physical, sensory or mental disabilities or lacking experience and knowledge, if they are under supervision or taught about safe use of the appliance and if they are aware of the potential dangers. Children should not play with the appliance. Children should not clean or perform maintenance on the appliance without supervision. Installation should be carried out in accordance with the valid regulations and according to the instructions of the manufacturer and by qualified staff. The water heater is constructed for cross-flow (non-pressure) system of installation! Before connecting it to the power supply, the water heater must be filled with water! If the heater is to be disconnected from the power supply, please drain any water from the heater to prevent freezing. Please do not try to fix any defects of the water heater on your own. Call the nearest authorised service provider. Dear buyer, thank you for purchasing our product. Prior to the installation and first use of the electric water heater, please read these instructions carefully. This water heater has been manufactured in compliance with the relevant standards and tested by the relevant authorities as indicated by the Safety Certificate and the Electromagnetic Compatibility Certificate. The technical characteristics of the product are listed on the label affixed between the inlet and outlet pipes. The installation must be carried out by qualified staff. All repairs and maintenance work within the water heater, e.g. lime removal, must be carried out by an authorised maintenance service provider. 2 Edition: 07/16

2. Operation The nameplate is located outside of the jacket shell between the inlet and outlet pipe. For your safety, the unit has been tested to EN safety regulations accordingly. We recommend the adjustment of the knob to the position "e". Such an adjustment is the most economic, with it the temperature of water shall be approximately 41 C in case of KSO/KSU 2005 or 35 C in case of KSO/KSU 3010, the excretion of limestone and thermal loss shall be smaller as by adjustment to higher temperature (poz. II - 55 C in III - 75 C). KSO - Device KSU - Device Set the temperature position cold Control lamp does not light up position * (star) Anti-freeze protection (15 C) position e EUP temperature 41 C (2005 type) or 35 C (3010 type) position II shower (55 C) position III max. 75 C Component: 1. housing 2. thermal insulation 3. vessel 4. heating element 5. conduit 6. thermoregulator 7. temperature limiter 8. infow pipe 9. drain pipe 10. temperature knob After connecting to the water and power supply, the heater is ready for use. By turning the knob of thermostat at the front side of the protecting cover, the wished temperature of water 75 C is chosen. The operation of electric immersion heaters is shown by pilot light which is lit during the time until the water in the heater is heating to the chosen temperature or to the intended switch off. During the heating the volume of water in the heater is increasing, which causes the dropping of water from the mixing valve. By strong squeezing of the mixing valve the dropping cannot be stopped but the mixing valve can be damaged. When the heater shall not be used during a longer time, its contents must be protected against freezing so that the electricity shall not be switched off, but the thermostat knob shall be adjusted to the position " ". With this adjustment the heater shall maintain 3 Edition: 07/16

the water temperature by approximately 9 C. But when the heater is switched-off the electric network, at risk for freezing, the water must be emptied from it. The outside of the heater is cleaned by mild solution of detergent. The solvents or rough cleaning means should not be used. By regular service check impeccable operation shall be assured and a long lifetime of the heater. The first check must be performed by authorised service workshop after approximately two years after the first connection. At check, it necessary lime stone must be cleaned which with regard to the quality, quality and temperature of the water used is gathered in the inside of the water heater. Service workshop shall after check recommend also the date of next check. Never try to repair any possible faults of the heater by yourself, but inform about it the nearest authorised service workshop. Type KSO for above the sink Type KSU for under the sink. 3. Connecting to the water supply 1 Closing valve 2 Pressure reduction valve 3 Non-return valve 4 Cross-flow mixing tap K Cold water W Hot water 1 Closing valve 2 Pressure reduction valve 3 Non-return valve 4a Cross flow mixing tap K Cold water W Hot water 4 Edition: 07/16

Prior to the electric connection, the heater must be obligatorily filled with water. By first filling the faucet for the hot water upon the mixing tap must be opened. The heater is filled with water when the water starts to run through the outlet pipe of the mixing tap. If the heater at connection would not be filled with water, at first switching-on the damage of thermal fuse shall occur and the heater shall not operate at all. 4. Connecting the water heater to the power supply network Connection of the water heater to the electric network must be performed according to standards for electric installation. The heater shall be connected to electric power supply over electric cable with plug. If the built-in cable shall be replaced with a new longer, the built-in cable may be removed and the new connecting cable inserted where the cable wires shall be screwed to the connection terminal. In order to do this the plastic lining of the water heater must be removed. This is done so that at first the plate is removed, inserted in the front side of the plastic lining. The plate is released so that in the slot between the inserted plate and the plastic lining at first at the thermostat knob and on the side in front of the knob cautiously a screwdriver is pushed in. When the plate is released at both sides, it can then be removed by hand. Than the thermostat knob is removed and the screw under the knob is unscrewed. At last also all four screws for fixing of plastic lining are unscrewed and the lining removed. 1 Thermostat 2 Thermal cut-off 3 Heating element 4 Pilot lamp 5 Connection terminal L Live conductor N Neutral conductor PE Earthing conductor Never try to repair any possible faults of the heater by yourself, but inform about it the nearest authorised service workshop. The water heater shall be built in according to the drawing and table with dimensions in a premise where there is no frost, as close as possible to the water outlets. It has to be fitted to the wall using appropriate wall screws with a minimum diameter of 5 mm. With regard to the needs, you can chose execution above the sink (KSO 2005 / KSO 3010) or an execution under the sink (KSU 2005 / KSU 3010). 5 Edition: 07/16

Mounting dimensions: Model Article Nr. A B C D E KSO 2005 250 580 301 256 390 213 264 KSU 2005 250 580 300 256 390 213 138 Modell Article Nr. A B C D E KSO 3010 250 580 100 310 471 265 371 KSU 3010 250 580 150 310 471 265 196 Technical datas Modell KSO 2005 KSU 2005 KSO 3010 KSU 3010 Volume [Litre] 5 5 10 10 Declared load profile XXS XXS XXS XXS Energy efficiency class 1) A A A A Water heating energy efficiency 32 35 35,3 35,1 (nwh) 1) [%] Annual electricity consumption [kwh] 525 527 523 525 Daily electricity consumption 3) [kwh] 2,475 2,49 2,464 2,477 Weight / filled [kg] 3,5/8,5 3,5/8,5 4/14 4/14 Input [kw] 2 Supply voltage [V~] 230 Protection class I Protection IP 24 Warm-up time from 10 C to 65 C [min] 10 10 20 22 Water pressure min. [bar] 0,5 Water pressure max. [bar] 5 Temperature setting of the e* thermostat Mixed water quantity at 40 C 2) [l] 10 10 17,2 16,4 Standby power consumption at 65 C [kwh / 24h] and room temperature of 20 C 0,28 0,33 0,5 0,52 1) Commission Regulation EU 812/2013; EN 50440 2) These values apply to the mixing of the water from the water pipe of about 10 C and the hot water from the hot water storage at a water temperature of about 65 C.EN 50440 *) Position "e" of knob means setting temperature of about 41 C at 5l device and 35 C at 10l device 6 Edition: 07/16

TECHNOTHERM Kundendienst: Fon: 0911 937 83 210 Lucht LHZ Elektroheizung GmbH & Co. KG Obere Hauptstr. 61 09232 Hartmannsdorf Fon: 03722 63370 Fax: 03722 633720 E-mail: info@technotherm.de Web: www.technotherm.de 7 Edition: 07/16