Fortimo LED Line Gen2 Module

Similar documents
Fortimo LED Line High Flux Module

ELLA ID. High CRI, High lm/w OptoDrive LED-module

CLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights.

Maxos LED General Lighting innovative, flexible solution delivers ideal light output

Technical application guide

DOME SERIES. Data will be subject to change without notice. COMMERCIAL 1

LUXCOMFO TM LED Flood Light Datasheet

Technical application guide

Philips MASTER LEDbulb DIM W & W E27/B K 230 V

Technical Application. Guide for LDN-PL W LED Panel Light LDN-PL W-A LDN-PL W-A-D

CoreLine Waterproof the clear choice for LED

Technical Application Guide for UP-SHINE LED Track Light

Product Description. Features. Table of Contents. CLM-DS08 Rev 11. Product family data sheet. Source with

CoreLine Batten the clear choice for LED

TRMUNV220ACXXXA UNIVERSAL VOLTAGE HIGHBAY RETROFIT KIT

Philips MASTER LEDbulb 7-40 W and W E27/B K 230 V

Table of Contents. Product Description. Features. CLM-DS08 Rev 9A. Product family data sheet. Source with. Characteristics - WhiteLight Dimming...

Sylproof Superia LED G2

Technical Application Guide for UP-SHINE LED Panel Light

Technical Application Guide for PHILIPS LED Lamps

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-E

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-L

OLUX LED Flood Light OSRAM. Datasheet APPLICATIONS.

HEP Tech Co., Ltd. Company Profile

Technical Application Guide for UP-SHINE LED Frameless Panel Light

Vaya Linear LP, White & Mono

CoreLine Panel the clear choice for LED

Technical Application Guide for UP-SHINE LED wall lamp UP-WL08-8W

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

Recessed and surface mounted LED downlight family

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight

Flow LED robust and streamlined

Technical Application Guide for UP-SHINE LED Panel Light

Flow LED robust and streamlined

Technical Application Guide for UP-SHINE LED Downlight

UniStreet simple, costeffective. range. UniStreet. Benefits. Features. Application. Specifications

Technical Application LED Pendant Light LUZ-PL W-W

FDV BA- Lighting AS BA24-CL76-8WD

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

SmartBalance Free Floor Standing. combining performance with smart design. Benefits. Features. Application. Specifications

Lum. Flux** [lm] 6500 K 1700 lm

Safety Certification of Solid-State Lighting Products. September 23, 2009 Todd Straka Director - Lighting Services

ArtLED Gallery and Museum Spotlights

ClearAccent - Affordable recessed LED spot

Affordable and reliable energy saving LED Lighting Luminaires

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-B

Technical Application Guide for UP-SHINE LED Frameless Panel Light UP-PL W-P

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-S3.

Technical Application Guide for UP-SHINE LED Spotlight

E10 & L9 Low Wattage Light Cone Data

TECHNICAL SHEET. Road and residential lighting luminaire MATRIX-S-01 60LED. About the product MATRIX-S LED

Technical Application Guide for UP-SHINE LED Ceiling light

performance PowerBalance, surface mounted Benefits Features Application Specifications

Technical Application Guide for UPSHINE LED Ceiling light

Technical Application Guide for UP-SHINE LED Panel Light

Excellence in LED Lighting. e-solis Edge Lit LED Panels.

Data Sheet Version 1.0

SmartBalance Free Floor Standing combining performance with smart design

Ledinaire Batten Simply great LED

Technical Application Guide for UP-SHINE LED Panel Light

LED A Lamp B2B A60 Filament 60W E27

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-AN

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

LED HIGH BAY LINEAR ECO SERIES

Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012

Product Specifications MaxLumen MRI LED Diffused Lighting

Medical LED. Superbly balanced and colour corrected LED-modules for medical use.

LED Reliability and Current Standards for Measurement

Cove Light AC Dim. Electrical Protection Class II, cetlus. Compatible with and controlled by leading/trailing edge phase-cut dimmers

Urbanlite. We light your world IK08 IP

Premier External TD. Installation Manual INS352-3

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

Optical benefits associated with PrismaLED technology. Enhanced Lumen Maintenance due to self cleaning design.

TECHNICAL SHEET. Road and street lighting luminaire MATRIX-01 LED MATRIX LED MATRIX LED. About the product

1. Key Features and Benefits

LED Golf Light B2C Frosted E14 40W

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

CoreLine Wall-mounted the clear choice for LED

LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright

ipanel LED Panel Light

LED Panel Light E830J

Challenges in SSL Design and Photometric testing Gautam Brahmbhatt, Head Technical (Verification Service)

LED Product Catalogue

K L Lead LV 3 Integrated K C Center K E End K S Solo. 2700K and 3500K not available with.

CoreLine Recessed Spot the clear choice for LED

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

Reflector T2 and GU10 6,000 hours

TECHNICAL SHEET. Road and street lighting luminaire DELFIN-03 30LED 60LED. About the product DELFIN-03 30LED, DELFIN-03-60LED

SECTION INTERIOR LIGHTING

Dimmable LED Retrofit Kit

ProAir an unrivalled combination of light quality and efficiency

Product Specifications

Lumination LED Luminaires

Less hassle, More savings

Overview of International Lighting Standards Steve Coyne Director, Light Naturally UNEP Consultant

LEDVANCE Downlight L DIM

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

LED Seamless VaporProof Fixture Installation Instruction

The Commercial LED Lighting Specialist

Transcription:

Fortimo LED Line Gen2 Module Fortimo LED Line 1ft 650lm 3R LV2 Fortimo LED Line systems are designed to replace fluorescent lighting in new luminaires. Fortimo LED Line Gen 2 systems are designed to replace conventional lighting in both fixed and dimmable luminaires. This latest generation is characterized by breakthrough high energy efficiency levels, up to 144 Lm/W. Fortimo LED Line systems also offer high quality white light in terms of color rendition and color consistency and are part of the Fortimo future proof promise. The Fortimo LED Line 3R system has been designed for applications where diffused lighting where energy efficiency and glare control are important. Benefits Increased energy efficiency Improved luminaire manufacturability Improved temperature management Applicable for all fluorescent luminaires Systems with Xitanium drivers 5-year limited system warranty Applications General lighting applications in office, retail, industry Ideal for applications requiring diffuse light Features Module efficiency up to 144 lm/w Introduction of push-in connectors increasing flexibility and enabling usage of bulk wiring and automated wiring High quality of white light

Commercial product name 12NC Fortimo LED line 1ft 650lm 830 3R LV2 9290 008 55803 Fortimo LED line 1ft 650lm 835 3R LV2 9290 008 55903 Fortimo LED line 1ft 650lm 840 3R LV2 9290 008 56003 Fortimo LED line 1ft 650lm 850 3R LV2 9290 008 56103 Optical characteristics - table per CCT 1, 2 Fortimo LED line 1ft 650lm 830 3R LV2 Parameter Min Approx. Max Unit Luminous flux 2 560 605 655 lm Module efficiency 122 134 145 lm/w Correlated color temperature (CCT) 3 3000 K Correlated color temperature (CCT) 4 3060 K Color coordinates (CIEx, CIEy) (0.433, 0.403) - Color consistency 5 3.5 SDCM CRI 80 - Radiation angle 120 deg Fortimo LED line 1ft 650lm 835 3R LV2 Parameter Min Approx. Max Unit Luminous flux 2 590 640 685 lm Module efficiency 127 139 151 lm/w Correlated color temperature (CCT) 3 3500 K Correlated color temperature (CCT) 4 3480 K Color coordinates (CIEx, CIEy) (0.407, 0.392) - Color consistency 5 3.5 SDCM CRI 80 - Radiation angle 120 deg Relative intensity (a.u) 1 0.8 0.6 0.4 0.2 0 380 430 480 530 580 630 680 730 780 830 Wavelength (nm) 3000K 3500K 2

Fortimo LED line 1ft 650lm 840 3R LV2 Parameter Min Approx. Max Unit Luminous flux 2 605 650 700 lm Module efficiency 130 143 155 lm/w Correlated color temperature (CCT) 3 4000 K Correlated color temperature (CCT) 4 4010 K Color coordinates (CIEx, CIEy) (0.381, 0.380) - Color consistency 5 3.5 SDCM CRI 80 - Radiation angle 120 deg Fortimo LED line 1ft 650lm 850 3R LV2 Parameter Min Approx. Max Unit Luminous flux 2 615 665 715 lm Module efficiency 131 144 156 lm/w Correlated color temperature (CCT) 3 5000 K Correlated color temperature (CCT) 4 5070 K Color coordinates (CIEx, CIEy) (0.343, 0.353) - Color consistency 5 3.5 SDCM CRI 80 - Radiation angle 120 deg Relative intensity (a.u) 1 0.8 0.6 0.4 0.2 Beam shape The Philips Fortimo LED Line Module generates a Lambertian beam shape, which is a pragmatic starting point for OEMs wishing to design secondary optics. 0 380 430 480 530 580 630 680 730 780 120 180 120 840 Wavelength (nm) 90 90 4000K 60 100 60 200 300 30 (cd/1000 lm 30 300 0 L.O.R.= 1.00 0-180 90-270 90-270 lmax 5000K 1, 2, 3, 4, 5, can be found on page 7 3

Electrical characteristics 1 Parameter Min Typ Max Unit Forward voltage 30.3 31.7 33.2 V Power consumption 4.4 4,6 4.8 W Minimum dimming for performance 10 % Number of parallel modules per chain 6 Bins 2 (F and G) Lifetime 1, 6 Parameter Min Typ Max Unit Lumen maintenance B50L70 50,000 hrs Δu'v at 6,000 hours 0.007 - Critical failures no spec known % Parameter Nominal 7 Life 8 Max 9 Tc [ C] 35 56 80 Current [ma] 144 225 285 Performance at I life and Tc life Flux [lm] Efficiency [lm/w] 3000K 880 121 3500K 925 126 4000K 945 129 5000K 970 130 Abs max ratings Parameter Min Typ Max Unit Current Imax 285 ma Case temperature Tc max 80 C ESD (direct contact) 8 kv ESD (air) 15 kv Isolation breakdown voltage 500 Vdc Ambient temperature -20 C Wiring Specification item Value Unit Condition Input wire cross-section 0.2 0.75 mm 2 solid and fine stranded 18 24 AWG Input wire strip length 6 7 mm Tested cable length* 4000 mm Total length of wiring including LED modules, one way * Note: connector suited for robot wiring* Note: connector 6, 7, 8, 9, can be found on page 7 4

Mechanical characteristics Parameter Min Typ Max Unit Length 279.75 280 280.25 mm Width 54.8 55 55.2 mm Height excl. connector 1.5 1.65 1.8 mm Height incl. connector 5.8 6.15 6.5 mm Warpage (IPC-TM-650) 2.1 mm Note: Bow & Twist of the PCB after production tested and released according IPC-TM-650 2.4.22 280 26 55 40 20 IN IN OUT OUT A A (2:1) Ø 0.25 49 76 26 80 7.75 1.5 Ø4.75 4.24 0.9 1.65 5.99 Hole allows wire feed through Connector, suited for robot wiring Polarity sensitive Screw hole (4x) Connector, suited for robot wiring Polarity sensitive IN IN OUT OUT Module specific info sticker Tc point Approbation and conformity marks Area suited for clamping (4x) 5

Tuning information Flux and efficacy versus current Relative value (%) 160% 150% 140% 130% 120% 110% 90% 80% 70% 60% 0.05 0.10 0.15 0.20 0.25 LED line current (A) Luminous flux Efficacy Flux and efficacy versus temperature at Tc Relative value (%) 104% 103% 102% 101% 99% 98% 97% 96% 95% 94% 20 30 40 50 60 70 80 Tcase ( C) Luminous flux Efficacy 6

Application information Compliance and approval IEC / EN 62031, IEC / EN 62471 10 11 Environmental REACH 12 Application information Zhaga Designation of the ECG housing (book-1 / annex C) Designation of the Book-7 LLE category BL4 L28W6 Luminous Flux category CCT category C006 4000 K CRI 80 The position of the temperature measurement point tp same as Tc point The value of tp, max 56 The value of tp, headroom - IP rating Overheating protection Luminaire class No IP rating No protection UL Class 2/ IEC Class II or Class III 1. Current specifications are subject to change, for the latest specifications, please contact your local Philips sales representative. 2. Photometric testing consistent with CIE 127:2007 2nd Edition 3. CCT for characterisation. Complies with ANSIC78.377A Specifications 4. CCT of Target Color Point 5. Production units will fall between +/- 0.2 of listed value. Note: 3.5 SDCM color consistency specification may not be sufficient for applications that are sensitive to color differences like wall washers, which typically require 2 SDCM. 6. Average rated life is based one engineering data testing and probability analysis. The hours are at the B50, L70 point - 50,000 hours life with 70% lumen maintenance at Tc point of 56 C for 3R and 61 C for 1R 7. Nominal value at which performance is specified 8. Value at which lifetime is specified 9. Maximum value for safety 10. Philips Fortimo Module is a Zhaga certified light engine. For more information visit www.zhagastandard.org 11. Indicates that the LEDs are components recognized with UL and complies with UL8750 Standard for LEDs 12. Restrictions on Hazardous Substances (RoHS) is a European directive (2002/95/EC) designed to limit the content of 6 substances [lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB), and polybrominated diphenyl ethers (PBDE)] in electrical and electronic products. For products used in North America compliance to RoHS is voluntary and self-certified 7

Lumen maintenance Lumen maintenace B10/B50 Fortimo LED line 1 ft 650 lm 3R LV2 Lumen maintenance (%) Ref: 18W T8 B10 B50 Specification cation Min.B50L70 0% Lumen depreciation (%) 30,000 hours proven by certified laboratory 0% The B10 and B50 graphs show expected lumen maintenance at current life and Tc life 0 10,000 20,000 30,000 40,000 50,000 60,000 Operating lifetime (hours) Lumen maintenace T-case Fortimo LED line 1 ft 650 lm 3R LV2 Lumen maintenance (%) Tc max 80 C Tc nom 35 C Tc life 56 C Specification cation Min.B50L70 0% Lumen depreciation (%) 30,000 hours proven by certified laboratory 0% The B50 graphs show expected lumen maintenance at current life 0 10,000 20,000 30,000 40,000 50,000 60,000 Operating lifetime (hours) 2013 Koninklijke Philips N.V. All rights reserved. Specifications are subject to change without notice. LE-6001-A 07/13 Philips Lighting Company A Division of Philips North America 10275 W. Higgins Road Rosemont, IL 60018 Tel: 800-322-2086 Fax: 888-423-1882 Customer Support/Customer Care: 800-372-3331 www.philips.com/ledmodulesna