Cleaning the internal optics surfaces

Similar documents
Administration of AMBISOME Using the GemStar Pump

INSTALLATION INSTRUCTIONS

Deluxe Vapor Steamer. Operations Manual

FRYMASTER TCF. Chicken Fryer

ACME DIAGNOSTICS STANDARD OPERATING PROCEDURE

Instruction Sheet DANGER

Instruction Sheet DANGER

I N ST R UC T I ON. MODEL HAB500 AroMatic TM BREAD SLICERS MODEL FORM (4-99) AROMATIC BREAD SLICER 701 S. RIDGE AVENUE TROY, OHIO

HydroFlux Welder Torch System T0-102 / T0-103

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

Ultrasonic Humidifier

DISPENSE TROUBLESHOOTING INDEX. Hot Tank Descaling Instructions are included in this Troubleshooting section.

UV Lamp and Quartz Sleeve Replacement/Maintenance

CBT LW MAINTENANCE GUIDE

kéìíê~=iqd=qìåöëíéå=dêáåçéê= lééê~íáçåë=j~åì~ä=

Align holes in retainer plate with the bolt holes on the legs. Start the threading the bolts only partially. You may need to pick up

INSTRUCTION MANUAL INSTRUCTION MANUAL. Revolutionary Upright and Portable Wrinkle Removal Machine

Operating / User Manual

Glovebox Usage Manual v1.4. When you enter the lab walk straight to the log book. Enter all information including N2 and O2/H2O levels.

Food Waste Disposer Instruction Manual

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

BMW E36 Thermostat Removal And Coolant Flush

Nilfisk Inc Winnetka Avenue North Minneapolis, MN REV.03( ) VF80189

Instruction Sheet. VIQUA UVMAX Lamp and Quartz Sleeve Replacement

OPERATION & MAINTENANCE MANUAL RHS680

Printer Startup and Demo Build The purpose of this section is to execute the following:

Requests for Daily Care and Maintenance

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

Thermal Stripper, TSAB-40 User Manual

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

Instructions for Use: Fiberscope and LED Light Source

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0

Advisory Bulletin. TB-106 Cleaning and Maintenance For Bobrick B-850, B-855, B-856 or B-858 Automatic Counter-Mounted Soap Dispensers

Thermal Stripper, TSFB-125 User Manual

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

INSTALLATION INSTRUCTIONS

EVAPORATIVE COOL MIST HUMIDIFIER Instruction Manual

Requests for Daily Care and Maintenance

16 OUTDOOR MISTING FAN

Washing Machine OWNER S MANUAL. MODEL:MFW-V1100DDi

OP40R 40cm Remote Control Pedestal Fan

OPERATION MANUAL. LED Coupling OM-TR355E. Please read this operation manual carefully and file for future reference.

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A

STOP ACRYLIC TUB WITH INTEGRAL DRAIN PLANNING BEFORE YOU BEGIN TOOLS AND MATERIALS: GETTING STARTED INSTALLATION INSTRUCTIONS.

Karess ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS

BEFORE OPERATING THE MACHINE: WARNING

Model:WHS-109FB1/WHS-109FW1/WHS-109FSS1

PANACHE ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS

Sanitise Syrup Lines & Valves. Taylor PH61 Cleaning every 14 days

INSTRUCTION MANUAL FOR DUTCHESS MODEL 260 BAGEL & BUN SLICER

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-20B CompriCart

Multi-Mode Electrode pro

HX Field Replacement Kit

Washing Machine OWNER S MANUAL TRWTL-70. Before using your washing machine, please read this manual carefully and keep it for future reference.

Reliability in Laboratory Centrifuges Since Operator s Manual. Models 614B, 614L, 614U/UL and 614V/VL Laboratory Centrifuge. Rev. 5.

FEI Nova 200 Dual Beam system maintenance

USER S GUIDE. ecal lite Software Access Code included! SUBSECTION. Read Guide Before Operating Product. Save Guide For Reference.

THANK YOU. For purchasing the VMI HYBRID TM

CK247 JDW STEAM MOP Instruction Manual

ADAIR ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS 4.0L EXPOSED CLASS FIVE ONE-PIECE TOILET 4.0 K-5306T/K-5306T-S

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

INSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

INSTRUCTIONS FOR OPERATION AND CARE OF

ULTRASONIC HUMIDIFIER WITH ANTIBACTERIAL TANK & BASE Instruction Manual and Warranty Information IM0012A READ AND SAVE THESE INSTRUCTIONS

Owner s Guide and Installation Manual

5 Maintenance. A November

SUPER NOVA SERIES UV STERILIZER HIGH INTENSITY ULTRAVIOLET STERILIZATION

DISPENSING TROUBLESHOOTING INDEX

Digijock Home Security

Heater with Air Conditioning. E-Series Ford Aeromaster

CBT Bowl & wrap replacement

OPERATION & MAINTENANCE MANUAL AC860

POLYMIX PX-IG 2000 Operating Instructions

FLUSH WATER SAVER DUAL FLUSH KIT

1. CONDITIONS FOR USE 2. SAFETY

Agilent 6400 Series. Maintenance Guide. Agilent Technologies

ADORABLE Ultrasonic Cool Mist Humidifier

3/4.8 AERODYNE 3/4.8L CLASS FIVE+

1500 RPM BURNISHER. Model P WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

CEILING FAN OWNER'S MANUAL

1.5 GALLON ULTRASONIC HUMIDIFIER MODEL # EE-5303W

PERSONAL Ultrasonic Cool Mist Humidifier

Owner s Guide and Installation Manual

LEAK DETECTION KIT. Your Leak Detection Kit should include the following items:

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Jiffy J-2000 Model Steamer FEATURES

Waterless Engine Coolants. General Installation Instructions

MOCCA CUBIC AUS/NZ. 08/53066/0 Issue 2

Falex Thermal Fowling Tester (FT2)

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-12 Task Force Pneumatic Portable Dental System

Altra Series Dampener

CEILING FAN OWNER S MANUAL

Instructions for Coating Fimbel Garage Door Panels

Pet. Easy Guide. VAX Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK - website:

START-UP AND CLEAN-UP PROCEDURES

Funne~ Jiffy J-4000 Model Steamer FEATURES INCLUDES: From the library of: Superior Sewing Machine & Supply LLC

Power Opener Under-The-Cabinet Can Opener

PERFORM Operating Document

FIREPLACE INSTALLATION

Transcription:

Cleaning the internal optics surfaces The face of the fiber-optic assembly and the lens are directly exposed to sample fluids inside the analyzer s flow cell. Automatic rinse cycles use high-pressure rinse water to flush debris from these optics surfaces. However, rinse cycles usually do not prevent the build-up of biological films and mineral deposits on the surfaces. To maintain optimum performance, you must periodically open the analyzer and mechanically clean these surfaces as described below. It s like you can rinse your teeth with water every day, but you really need the dentist to clean them periodically. Note: The Clean parameter is a standard analyzer parameter that indicates the cleanliness of the internal optics. You can view this parameter s value using the Web Interface see Using the Web Interface on page 41. The internal optics should be cleaned at least monthly or when the parameter falls to near 0.45 or sooner if recommended by ZAPS. After a thorough cleaning and calibration, this parameter should increase nearer 1.00. Required materials Caution: When cleaning the optics, use only the tools and supplies included in the ZAPS optics cleaning kit, refill pack, or specified below. Other substances can damage the optical surfaces in the analyzer. The following items are included in the ZAPS optics cleaning kit: Plastic cleaning tool Hex wrench (if needed) Nitrile rubber gloves Optical cleaning wipes Sterile cotton balls Cleaning liquid O-rings In some situations described in the steps below, you may need to supply additional material: CLR Calcium, Lime & Rust Remover from Jelmar or equivalent hard-water cleaner (such as ZEP Calcium, Lime and Rust Remover from Home Depot) A refill pack provides a supply of consumables from the optics cleaning kit. Contact ZAPS Technologies see Getting Support on page 119. Reminder: Every year, get an updated version of the optics cleaning instructions at the following location: www.zapstechnologies.com/wp-content/uploads/ ZAPS_OpticsCleaningInstr.pdf 81

Cleaning process The following steps require an Internet connection to the Web Interface see Using the Web Interface on page 41. Display with Buttons For steps 1 2: Open menu, select Manual Optics Clean. Wait for prompt. Part 1: Use the Web Interface to prepare the analyzer 1. On a computer, log in to the analyzer web server and view the Web Interface screen. Note: In the next step, the analyzer may take up to a minute or longer to respond, depending on the software version. Wait for the analyzer to respond. 2. Go to the Control tab and click Prepare the Station for a Manual Optics Clean. When the preparation is completed and the cleaning steps are displayed, continue below. Caution: During the optics cleaning process, do not turn off or remove power from the analyzer except during annual preventive maintenance. If you turn off the analyzer, the automatic calibration sequence may be disrupted when you resume operation. Part 2: Remove the lens holder 3. Get ready to remove the lens holder: Important: Turn off the sample and rinse-water supply lines. (If the drain line has a shutoff, turn it off also.) Open the analyzer s lower door. Put on a pair of nitrile gloves. Put one or two paper towels inside the bottom of the lower cabinet to catch and clean up the small amount of fluid that will drain out of the flow cell. Caution: When removing or installing the lens holder in the flow cell, do not allow the lens to touch the sides of the flow cell. Any contact may contaminate or damage the lens and require replacement. WARNING: For an analyzer with a motorized lens holder (XR assembly), pictured farther below, (1) do not unplug any of its cables, and (2) do not loosen the four long screws holding the motor. Otherwise, serious damage to the equipment is likely to occur. 82

4. On the bottom or side of the flow cell (see two examples below), use the knurled knobs or a hex wrench to remove the screws holding the base of the lens holder to the flow cell, then carefully pull the lens holder out of the flow cell. 5. Place the lens holder in a safe place (see the illustrations below): For a fixed lens holder, stand it upright on its base in a safe place where it is protected from accidental contact do not touch or bump the lens. For a motorized lens holder, lay it on its side in the bottom of the lower cabinet do not touch or bump the lens. Do not unplug any of the cables. lens lens holder O-ring motor assembly Fixed lens holder (example) Motorized lens holder Note: If the lens holder was difficult to remove from the flow cell, or if the lens holder or flow cell has any mineral deposits on its surfaces, perform the following steps before continuing the cleaning process: 1. Thoroughly moisten an optical wipe with CLR Calcium, Lime & Rust Remover from Jelmar (or an equivalent hard-water cleaner, such as ZEP Calcium, Lime and Rust Remover). 2. Drape the CLR wipe over the cleaning tool and cotton ball (as shown farther below), then insert the wipe and tool into the flow cell and wipe the inside surfaces. Keep the wipe in contact with the surfaces for about 30 60 seconds. 3. Use the CLR wipe to wipe the lens and holder. Keep the wipe in contact with the surfaces for about 30 60 seconds. After cleaning with CLR, perform all of the optics cleaning steps below this will remove all traces of CLR. 83

Part 3: Clean the fiber-optic surface with cleaning fluid and tool 6. Get ready to clean the fiber-optic surface: Vigorously shake the bottle of cleaning liquid included in the kit. Continue until no deposits remain at the bottom of the bottle. Place a cotton ball in the center of a new optical wipe, then place the cleaning tool so one end touches the cotton ball. If the end of the tool is recessed, put the cotton ball in the recess. Drape the wipe over the full length of the tool. optical wipe cotton ball cleaning tool Caution: Do not touch the fiber-optic surface with your hands or any other material except the special optical wipes provided in this kit. Use only the ZAPS optics cleaning liquid provided in this kit. Any unapproved material or cleaner may contaminate or damage the surface and require replacement. 7. Shake the special cleaning liquid, then use it to soak the wipe at the end of the tool. 8. Insert the cotton-ball end of the tool and wipe into the bottom of the flow cell until it touches the surface of the fiber-optic bundle inside at the top of the flow cell. (If the tool is too long to fit, cut it off shorter.) 9. Twist the tool and wipe several times while pushing inward. Make sure the wipe turns with the tool. Then remove the tool and wipe. 10. Repeat steps 7 9 using a new wipe. Part 4: Clean the lens, holder, and O-ring, then install Caution: Do not touch the lens with your hands, gloves, or any other material except the special optical wipes provided in this kit. Use only the ZAPS optics cleaning liquid provided in this kit. Any unapproved material or cleaner may contaminate or damage the surface and require replacement. Caution: If the lens is partially covered by a plastic cap, clean the exposed surface of the lens using only a clockwise motion. Otherwise, the cap could be loosened or unscrewed. 11. Wet a new optical wipe with the special cleaning liquid, then use it to thoroughly scrub the face of the lens using only finger pressure. 12. Clean the body of the lens holder (the part that fits inside the flow cell) by wiping it with the same optical wipe. 13. If required, remove the old O-ring from the base of the holder and install a new O-ring from the kit. If several sizes are included, choose the same size as the old O-ring. 14. Wipe any debris from the O-ring and insert the lens holder into the flow cell do not touch or bump the lens. 84

15. Install the screws that fasten the holder to the flow cell. Tighten them sequentially to compress the O-ring evenly: Hand-tighten all screws then, for screws with hex-socket heads, tighten about ¼ turn more on each screw using a hex wrench (you should feel increased resistance at each screw). Screws with plain heads Screws with hex-socket heads 16. Get the analyzer ready to restart: In a convenient location, record the date you cleaned the optics. Clean up and close the analyzer cabinet. Turn on the sample and rinse-water supply lines. (If the drain line has a shutoff, turn it on also.) Check for leaks. If the analyzer is powered off, turn it on. Display with Buttons For step 17: Select Done Cleaning. Important: If the display does not show this option, open the menu and select Manual Optics Clean, then select Done Cleaning. Part 5: Restore normal operation 17. On the Control tab of the Web Interface, click Manual Optics Clean Complete. Wait for the progress bar to complete and display the normal Control tab. The status initially shows the calibration activity, then eventually changes back to normal (taking measurements). 18. Check the Web Interface after 15 30 minutes to verify the cleaning was good. Depending on the software version, the calibration could take up to 30 minutes before parameter measurements resume. Caution: During the first 15 30 minutes of the calibration, the analyzer checks the effectiveness of the cleaning. If the cleaning is not adequate, operation stops and a message is displayed on the Web Interface and front-panel display telling you to repeat the entire cleaning process. In this situation, operation will not resume until you clean the optical surfaces thoroughly. Important: Notify ZAPS Technologies if you installed any new hardware as part of this maintenance. ZAPS will update the analyzer software to account for the new hardware. 85