Cold Door 2 LED Retrofit Kit Lighting System

Similar documents
Cold Deck Canopy and Shelf Lights and Retrofit Kit

Cold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended

HighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75

Innovative Lighting R-Series Vertical Refrigeration

Innovative Lighting R-Series Overhead LED Conversion Kits

Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits

Dioluce Products Installation Instructions

1 General Description

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

Honeywell Durafit LED Retrofit Kit

1 x4 Dimmable LED RetroFits

HPNLS-RT. Installation Manual

INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

HPNLS-LO. Installation Manual

LED Emergency Battery Backup

EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

LED Flat Panel Retrofit

ProStar Ceiling Fan PS52. Installation Instructions Instrucciones de instalación Instructions d installation

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

Installation Instructions

Service Manual. Model Number: Compact Fireplace DF203A DF2006. UL Part Number to 800

MaxLite LED Vapor Tight Linear Fixture

Installation Instructions

Dimmable LED Retrofit Kit

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

WARNING Risk of fire and electrical shock. DISCONNECT POWER AT ELECTRICAL PANEL before installing or servicing this product.

HP-SUBMERSIBLE. Installation Manual WARNING: DO NOT LIFT FIXTURE BY CABLES.

SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400

Installation Instructions. Tersen. Ratio Canopy 1.5

installation and operation manual for Hunter Ceiling Fans

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

EMERGENCY POWERHUBB NODE INSTALLATION AND OPERATION GUIDE

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

DHL-LP-LED Low Profile LED Linear High/Low Bay

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

DP25 & DR25 RECESSED T-BAR INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

Fillmore Small Pendant Assembly and Installation Instructions

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

Owner s Guide and Installation Manual

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

SERVICE BY QUALIFIED PERSONNEL ONLY

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

EcoBrite Smooth Light LED Light Fixtures

Owner s Guide and Installation Manual

MAXLITE RKT LED Retrofit Kit

Installation Guide. For Model: COS52OSB5CR READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE. net weight of fan: lb (9.9 kg) PRINTED IN CHINA

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

Installation guide. Philips EvoKit LED 2x4 and 2x2

Important Safety Instructions. Important Safety Instructions

LED IMPORTANT SAFETY INSTRUCTIONS

Table of Contents. What to Expect with. Mounting Options. Tools Needed

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

INSTALLATION INSTRUCTIONS

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

MaxLite LED Round Pendant Highbay Series

5LCM52XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : AC-552AL

3CLMR56XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3CLMR56XXD

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

LED RETROFIT SOLUTIONS

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

LED IMPORTANT SAFETY INSTRUCTIONS

LED RETROFIT CONVERSION KITS

14PRR62XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 14PRR62(X)

Juna Ceiling Fan JU54. Installation Instructions Instrucciones de instalación Instructions d installation

1. Basic safety information 3 2. Proper use 3

HIGH LUMINOUS EFFICIENCY

5AZR56XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5AZR56XX

3SKYR56XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 3SKYR56(XXXXX)

Installation Guide. For Models: E-DCF52BNK5C3 E-DCF52FBZ5C3 E-DCF52MWW5C3 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

TSLED STAIRWELL INSTALLATION INSTRUCTIONS

Installation Guide. For Models: E-PD52ABZ5C4 E-PD52BP5C4 E-PD52WW5C4 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

3DIR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3DIR52XXD

Universal Fan and Light Remote Control

Installation Instructions for W2H Series Signals

Solatube Daylight Dimmer Installation Instructions

Innovative Lighting Smooth Light Recessed Luminaires

5DI52XXD/5DI52XXD-L Series Fan UL Model No. : 5DI52. Owner s Guide and Installation Manual

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

3AVOR56XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 3AVOR56XXXXX

MaxLite LED High Bay Fixtures

F.P.O. Installation Guide. For Placement Only

Installation Instructions Labor and Delivery Exam Light Set

Bathroom Exhaust Fan/Fluorescent Light Combination

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

Nuclear Associates

3VNR52/42XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3VNR52XXD / 3VNR42XXD

IMPORTANT SAFETY INSTRUCTIONS:

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

Table of Contents. What to Expect with Your Installation. Tools Needed. Mounting Options. Ceiling Bracket. Wiring.

Transcription:

PAGE 1 OF 6 General Information Cold Door 2 is intended for use inside commercial refrigeration cases with packed foods only. Cold Door 2 LED luminaire should only be used with SloanLED 100 Watt 24 VDC Power Supply or an approved equivalent. Use only a damp cloth and mild cleaning agent to clean Cold Door 2. The Cold Door 2 Retrofit Kit (retrofit kit), in the context of this guide, is the entire component parts needed, including these installation instructions, for a retrofit luminaire conversion. Retrofit luminaire conversion is the act of modifying, with the parts provided in the retrofit kit, a luminaire already manufactured and in service in order to convert the luminaire to a LED light source from its original light source. The refrigerated display merchandiser is considered the luminaire in this context, and the complete retrofit kit is assembled during the audit of each merchandiser, on site, prior to installation. Tools and Accessories Recommended Do not cut or remove existing primary case wiring. Tools and connections shown are for secondary connections: Gloves, safety glasses, flat and Phillips head screwdrivers, ¾ or 1 in (19 or 25 mm) self-drilling/self-tapping #8 or #10 pan or hex head screws, angle drill is required (standard cordless drills will not work), measuring tape, electrical tape, wire strippers, twist-on or push-in UL Listed wire connectors, tie-wraps, and 18 gauge wire.

1. Power Supply 2. Center Clip 3. Clip 4. Power Controller 5. Dimming Controller 6. Motion Sensor 7. Cold Door 2 Center 8. Cold Door 2 9. Retrofit Sticker PAGE 2 OF 6 1 2 3 4 5 6 (optional) (optional) 8 7 9 Check inventory of retrofit equipment prior to dismantling current lighting system in refrigerated case. Identify required quantity of Cold Door 2 Centers and s and power supplies. e power supply is needed for one to five doors in most configurations. Five door cases/frames with Cold Door 2 using 6 ft (1800 mm) or greater length luminaires require two power supplies. FOR YOUR SAFETY Read and observe all NOTES, CAUTIONS and WARNINGS shown throughout these instructions. Installation to be performed by factory trained service personnel only. For use inside commercial refrigeration cases with packaged foods only. Gloves and safety glasses or goggles should be worn while performing installation. This product is UL listed for dry and damp locations. Electrical specifications per luminaire: maximum 1.0 A, 24 VDC, Class 2 circuit. The Cold Door 2 retrofit kit, also known as Retrofit LED Panels, may be employed as replacement panels for any UL Listed Commercial Refrigerators & Freezers, Door Frame type. WARNING Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and components. WARNING Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of Refrigerator/Freezer electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. WARNING Risk of fire or electric shock. Install this kit only in Refrigerators/Freezers that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire. ly those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installation. Do not leave any other open holes in an enclosure of wiring or electrical components. WARNING To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY UL OR AUTHORITIES HAVING JURISDICTION. Place Retrofit Sticker next to power switch on the refrigerator or freezer case.

LED Light Directivity Center Light LED Light Placement Center PAGE 3 OF 6 Center Light Cold Door 2 Center luminaires emit light on both sides. Cold Door 2 luminaires emit light in one direction only. luminaires can go on right or left sides of refrigerator case. NOTE: Pay careful attention to orientation of end luminaire directivity during installation. Preparation for Install WARNING: Risk of electrical shock. Locate main circuit breaker panel, de-energize, and perform lockout/tagout prior to retrofitting case. All primary wiring must be done by a licensed electrician. 1. Remove fluorescent lamp fixtures on all doors to be retrofitted (metal clips, lens cover, lamp holders and reflector, if installed). 2. Open raceways to expose all primary wiring, secondary wiring, and ballasts. These will either be in door mullions or behind the lower panel in the electrical raceway, depending on case model type. 3. Disconnect both primary and secondary wiring from all ballasts. Remove secondary wiring from refrigerated case.

PAGE 4 OF 6 Installation Ballast Output Secondary New Secondary wire Secondary CAUTION: Power supplies should not be mounted near any other heat generating element. Ballast Input Primary Primary Primary wire e power supply is needed for one to five doors in most configurations. NOTE: Five door cases/frames with Cold Door 2 using 6 ft (1800 mm) or greater length luminaires require two power supplies. 4. Remove installed ballast(s). Choose one former ballast location for power supply to be installed in. Mount power supply with two self drilling/self tapping screws through tabs in both end caps. Note: Primary Wiring Connections CAUTION: Primary and secondary wiring need to be physically separated inside of the raceway. AC Neutral to Power Supply White AC Line to Power Supply Black Earth Ground to Power Supply Green SECONDARY SIDE 5. Connect 120/240 VAC 50-60 Hz to power supply s primary wires (refer to wire description on power supply label). Use UL listed twist-on or push-in connectors for connections. Follow connector manufacturer s instructions. 6. Installation with optional Power Controller or Dimming Controller: The Power Controller or Dimming Controller is connected to secondary side of power supply. Cat 5 cable for dimming may run behind panel and outside of case if required. CAUTION: All primary connections including grounding must comply with all national and local codes and/or requirements. Have a licensed electrician connect primary wires. NOTE: e Power Controller or Dimming Controller required per power supply. A Power Controller and Dimming Controller should not be used together.

Mounting 6-12 in (150-300 mm) from top PAGE 5 OF 6 7. Mount luminaire by screwing a ¾ in (19 mm) self-drilling/self-tapping screw into mullion through bracket in top and bottom end cap. If interference is experienced between light and mullion, refer to steps 8 and 9. Otherwise continue to step 10. 6-12 in (150-300 mm) from top 8. Alternate Mounting: Attach mounting clips as shown in diagrams. Use 1 in (25 mm), self-drilling/self-tapping screws. Stainless steel screws are recommended. 9. Alternate Mounting Continued: Snap luminaire into mounting clips. Fix vertical position of lights by screwing a ¾ in (19 mm) self-drilling/self-tapping screw into mullion through bracket in bottom end cap. CAT 5 Cable DM PS WARNING: Risk of electrical shock. Unused wires on Cold Door 2 luminaires must be individually capped off or removed. DM PS 10. Run new secondary wire from power supply through holes in door frame mullions to luminaire. 11. Re-energize power circuit after installation is complete. Check secondary current of each power supply to ensure it is not overloaded per rating on label. Replace all covers and guards that were removed during preparation and installation.

PAGE 6 OF 6 Power Controller Settings Level Merchandising Setting () SW1 SW2 Percent of Full Energy Saver ON OFF 50% Standard OFF ON 75% MerchandiserMax ON ON 100% Factory setting Dimming Controller Settings Power Controller P/N 701929 Dimming Controller P/N 701890-PWR Merchandising Setting () Dim Mode Level SW 1 SW 2 Percent of Full SW 3 SW 4 SW 3 Off SW 4 SW 3 SW 4 Off Energy Saver ON OFF 50% 15% 0% 0% Standard OFF ON 75% 30% 7.5% 0% MerchandiserMax ON ON 100% 55% 25% 15% Factory setting is 100%, 0% Dimming. Selectable Duty Cycle output via SW 1 and SW 2 ( level when shopper in area). Default setting from factory is standard. Selectable Duty Cycle output via SW 3 and SW 4 (brightness level when no shoppers in area). Percentage values represent brightness and power of maximum system load. Removal Instructions 1. De-energize system as outlined in Preparation for Install section on page two of this installation guide and undo electrical connections to LED lights. 2a. Remove lower, then upper mounting screws in end caps while supporting light. 2b. For alternate mounting method, using a flat tip screwdriver, insert tip between mounting clip and LED light to pry from clip edge. 3. Repeat process for remaining lights. Make sure to continually support LED lights with a free hand during removal. 4. Open mullions or raceway, remove power supplies. 5. Cap or remove all primary wires. US patents and foreign patents pending NSF/ANSI 2 Customer service and technical support 888.747.4LED (888.747.4533) SloanLED.com info@sloanled.com P/N 401408 Rev D 2017-04-07 Europe: Customer service and technical support +31 88 12 44 900 SloanLED.com Europe@SloanLED.com