Lovely and flexible Fan Coil Units. GEA Flex-Geko. Solutions for all demands Basic and Comfort. Air Treatment

Similar documents
GEA Fan Coil Units Effective and quiet. Quality in detail GEA Cassette-Geko. Product Brochure

Efficient and comfortable air conditioning solutions for every requirement GEA Flex-Geko Comfort Edition

Product Brochure Fan Coil Units Effective and quiet HyCassette-Geko and Cassette-Geko. Quality as a sign of the times

HyCassette-Geko & Cassette-Geko» Fan Coil Units

Product Brochure Fan coil units Flex-Geko Comfort -Edition. Efficient and comfortable air conditioning solutions for every requirement

Product Brochure Unit heaters for retail and industrie MultiMAXX. Flexible, powerful, diversified

Product Brochure Unit heaters for retail and industrie MultiMAXX. Flexible, powerful, diversified

GEA Air Handling Units Modular configuration. Integrated refrigeration with optimized energy efficiency GEA CAIRplus.

Press Folder IFH/Intherm 2008

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

Grohtherm Wireless! Installation Instructions Pumped High Pressure

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems

Grohtherm Wireless! Installation Instructions Pumped

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES

Product Brochure Air Handling Units with Double-Plate Heat Exchanger CAIRplus SX ECOTWIN cool. Energy efficiency through adiabatic cooling

Intelligent Technology and Timeless Design

Grohtherm Grohtherm 1000

Safe Enclosure Cooling

Heating and Drying Cabinets HeatEvent

Power packs TectoRack. Energy-saving and ecological CO2 power packs

Product Brochure Low-profile air handling units ATpicco. Modular configuration with highly efficient energy recovery

CASSETTE UNIT. Comfort Circle

Multidecks TectoDeck MD4 Leho TectoDeck RI4 Leho. Energy efficiency with a system

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

VERSO Air Handling Units

Heating and Drying Ovens HeatEvent

Helios in a new dimension.

SecurWATCH IP. The safety net for disoriented persons with intelligent additional functions HEALTH CARE

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Control Products & Systems OEM

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Cassette units Model Comfort Circle. - heating - cooling - ventilation

Multideck cabinet. TectoDeck MD2 e-ventus. A multideck breakthrough in energy efficiency

Miele built-in appliances - Warming drawers

McQuay HydroflexTM Residential and Light Commercial Chilled Water System

Technical documentation Fan coil unit

SIMPLICITY OR FULL MODULARITY?

Modular Air Cooled Scroll Chillers

Hi-Pres Cooling Products Catalogue. Product Catalogue

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Integral X-LINE. Security without boundaries. FIRE ALARM.

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Flexible and efficient: Close Climate Control for IT equipment

COOLflow 4E PRODUCT RANGE

SIMPLICITY FULL MODULARITY?

Gas condensing boiler (wall mounted) TopGas

LD200 / RLD400 LD200-G /RLD400-G

maxsys TRIO/DUO BOILER SYSTEM

Conditioning your ambient, maximising your comfort.

Product brochure For a good working environment under extreme conditions Intelligent air treatment with CAIRplus Air Handling Units

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

IT Cooling Solutions. MiniSpace and MiniSpace EC. Reliability for small and medium-sized IT rooms

Oil-injected rotary screw compressors GA GA

Grohtherm 1000 Cosmopolitan. Grohtherm 1000 Cosmopolitan. Design & Quality Engineering GROHE Germany /ÄM /06.12

Freezer and cooler islands TectoFreeze IS1. Reliable islands for chilled and frozen food

Küba SF blastfreezer. High-performance air cooler for blast chilling and shock freezing

Refrigerators and freezers up to 400 litres

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

EP A2 (19) (11) EP A2 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2012/50

Energy efficiency with a system

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Multideck cabinets TectoDeck MD 3 e-visio. Two multideck cabinets in one. Heating systems Industrial systems Refrigeration systems

SUPPLEMENT TO OPERATION MANUAL Modular Air Handling Units CAIRplus ECOTWINcool

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation

BWL air heat pumps BWS brine heat pumps

ENERGY TOP. Condensing boiler solutions

Industrial cooling systems LT

Unit heater with accessories

Advance Split

American Brand with Global Reach. Model: SMLW-SAGL

DEFECTOVISION IR. Non-Destructive Testing of Steel Billets and Tubes

Welcome to Micro-Epsilon

Küba SG commercial

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING.

Installation and User Guide living connect Electronic Radiator Thermostat

30HXC Nominal cooling capacity kw

CONDAIR ME. In-duct evaporative humidifier and cooler Very low energy operation. Humidification and Evaporative Cooling

Heating with pellets kw

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Avensys Avensys FIN EST SLO RUS UAE

Liebert HIROSS for Telecom

Refrigeration dryers with Energy Saving Impulse Technology and Thermal Mass 0,3-27,0 m³/min Purifying your compressed air, increasing your efficiency.

TEPZZ 87_ 6A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

Eurosmart Cosmopolitan. Eurosmart Cosmopolitan. Design & Quality Engineering GROHE Germany /ÄM /10.11

INFO. Compact DUAL. GADC Air Cooler for HFC and CO 2. Dual discharge air cooler with and without integrated condensation water pump.

VERSO Air Handling Units

COMPRESSOR SYSTEMS MADE IN GERMANY G-DRIVE & V-DRIVE SCREW COMPRESSORS

TEMPERATURE SHOCK TEST CHAMBERS

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

GP SERIES Packaged Chillers

The full range of Evaporator Controls from ADAP-KOOL

TopGas Wall Hung Condensing Gas Boiler

Premium freezers combining functionality, elegance and energy efficiency

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

Effective, efficient response for emergency situations Risk Management

Hi-Pres Cooling Products Catalogue

Transcription:

Lovely and flexible Fan Coil Units GEA Flex-Geko Solutions for all demands Basic and Comfort [21 C] 32 db(a) Air Treatment

GEA Flex Fan Coil Units Heating, cooling, and ventilating fast and efficiently Unlike radiators and classical flat radiators, fan coil units not only can heat rooms, but can also cool and ventilate them. With 2-litre units, seasonal switch-over from heating to cooling operations is possible, and vice-versa (by reversing the medium supply). The 4-litre units additionally offer connections for heating and cooling circulation systems, and therefore allow spontaneous change-over between the modes of operation. Fan coil units actively direct the air to be treated through the heat exchanger, with especially effective heating or cooling. They bring room air to the desired temperature faster and operate with smaller heating or cooling surfaces. Their enhanced heat transfer enables lower feed temperatures during heating, and higher feed temperatures during cooling. This minimises losses and saves energy between the boiler or the chiller and the final unit. A choice of fan speeds, as well as valves to regulate the flow volume, enable flexible control of unit output. Adjustable air-outlet grills, in addition, assure uniform distribution of temperaturecontrolled air in the room. Comfortable climate-control solution: VDI 6022 (D) Tested room-air hygiene Seal of hygiene SWKI VA 104-01 (CH) Tested by ILH BERLIN Heating and cooling in one unit Assuring desired room temperature with smaller units Energy saving with lower feed temperatures during heating, and with higher temperatures for cooling Flexible control Recirculated-air units in accordance with VDI 6022 2 PR-2008-0305-GB We reserve the right to make changes without notice Version: 09/2008

Our models in the Basic and Comfort Editions The right version for every requirement The GEA Flex fan coil units are available in the Basic and Comfort Editions. Both of these variations are based on the same equipment platform, and employ this platform with various system components. This enables numerous equipment configurations. Purity and timeless design the Basic variation The Basic Edition model, with modest grey-white enclosure, contains high-quality technology and offers (according to version) connections for hot and/or cold water, a three-speed fan, and an air filter. Various valve types allow coordinated and precise heating and cooling. With its extremely user-friendly control system, the GEA Flex fan coil unit is therefore the perfect starter model for comfortable, decentral climate control of your rooms. Greater expectations in many variations the Comfort Edition The Comfort Edition of the GEA Flex offers additional functions and more features. It enables climate control of rooms in mixedair operation, and treatment of the air with finer filters. According to the requirements, Comfort units offer hot and/or cold water connections. They can be equipped with additional electrical heating, and with an integrated direct evaporator which allows a combination with outdoor split-climate units. The enclosure is designed for various air-intake and -outlet variations, and a light-grey band makes the unit optically even slimmer. The basic edition of the GEA Flex fan coil unit offers reliable technology for many applications. This starter unit is well suited for user-friendly heating and/or cooling, and can be combined with various accessory components. Installation sizes and diversity of performance Both GEA Flex variants, Basic and Comfort, are available in 8 installation sizes with a height beginning at 504 mm, and a uniform depth of 240 mm. The width will vary according to output, between 840 and 1,890 mm. The 8 unit sizes allow a selection that optimally matches the required output. The heating and cooling output ratings lie between 1 and 20 kw*. The circulating air volume coordinated to these output ratings varies between 150 and 1,800 m³/h. The Comfort Edition, with its distinctive light-grey band, can climate-control rooms in mixed-air operation as well. It can be equipped with an additional electrical heater if required. Its various air-intake and -outlet directions guarantee flow-optimised airflow routing for all applications. * Heating: pumped hot water, 70/50 C, tl1 +20 C * Cooling: pumped cold water, 6/12 C, tl1 +27 C, 46% relative humidity PR-2008-0305-GB We reserve the right to make changes without notice Version: 09/2008 3

Equipped for virtually every use With GEA Flex fan coil units, you can flexibly plan for every application As a result of their modular concept, GEA Flex fan coil units can be employed for many and various applications. These models are effective with wall or ceiling installation. They function highly satisfactorily on a stand-alone basis with enclosure, or can be mounted virtually invisibly as base units, with the required air outlets, behind a wall or above a suspended ceiling. The GEA MATRIX control system, integrated as desired, adapts to each and every functionality. The operator control units with or without integrated timer switches provide the interface to the user. The control units can be installed in the units themselves, or externally. Satisfies virtually all requirements: Flexible setup and installation variations Integration possible behind walls or above suspended ceilings The GEA MATRIX control system, adapted to the required functionalities Integration into the building-services management system via various interfaces Combination with other fan coil units or GEA products Flex units with primary-air connection can be easily combined with a central ventilation system. The control interfaces likewise allow uncomplicated integration into the building-services management system. GEA Flex fan coil units heat, cool, and ventilate offices, sales rooms, and public facilities. Prominent hotel chains use them gladly owing to their quiet and reliable operation. With their cost-effective operation and flexible application possibilities, GEA Flex fan coil units set standards for advanced climate-control solutions. 4 PR-2008-0305-GB We reserve the right to make changes without notice Version: 09/2008

Wall and ceiling models Basic Edition Already with the Basic Edition of GEA Flex fan coil units, the most common requirements for climate control of rooms can be quietly and reliably satisfied. These robust units are highly effective for typical flush-mounted applications. Only recirculated-air operation Basic model shown here: without enclosure ceiling version four-pipe system valves mounted The Basic Edition has been designed for heating or cooling in recirculated-air mode. It is effective for all applications for which a standard flush-mounted situation exists: for example, under windows. The horizontal ceiling installation is ideally suited, for example, for shops, workshops, and other rooms where floor space is at a premium. Wall and ceiling models Comfort Edition The Comfort Edition of GEA Flex fan coil units satisfies requirements, for example, in which mixed-air options are desired or where quiet heating and cooling are expected. They are also ideally suited for cases in which exceptional installation situations prevail. Recirculated- or mixed-air operation Basic mixed-air model shown here: without enclosure wall version four-pipe system valves mounted The many possible intake- and outlet-air combinations, and the extremely quiet fans, mean that Comfort Edition models are something special. The possibility of ordering these models with mixed-air operation, and/or with electrical heating, expands their application spectrum. In addition, the great diversity of accessories and the availability of various control modules all mean that the Comfort Edition satisfies practically all situations. PR-2008-0305-GB We reserve the right to make changes without notice Version: 09/2008 5

Whether at home, at work, or in a hotel: GEA fan coil units reliably assure feel-good room climate. High-performance fans take the room quickly to the desired temperature, and quietly maintain it at the required level. Basic or Comfort > the requirement decides [One equipment platform] [8 installation sizes] [2- and 4-pipe systems] [150 1,800 m³/h] [1 20 kw] [Heating, cooling, and ventilation] With high-performance functions for feel-good climate 6 PR-2008-0305-GB We reserve the right to make changes without notice Version: 09/2008

GEA Flex Fan Coil Units Enclosures 1 4 5 6 7 8 1 4 5 6 7 8 Air intake on the narrow side; air outlet on the narrow side. For recirculated-air operation with wall or ceiling installation. Free air suction required approx. 10 cm from the building. Without feet. Air intake on the narrow side; air outlet on the front side. For recirculated-air operation with wall or ceiling installation. Free air suction required approx. 10 cm from the building. Without feet. Air intake on the front side; air outlet on the narrow side. For recirculated-air operations with wall, ceiling, or floor installation. For setup open in the room: with optional back wall or narrow-side cover panel. Intake-air opening with grill integrated into the enclosure. Without feet. Air intake on the front side; air outlet on the front side. For recirculated-air operations with wall, ceiling, or floor installation. Intake-air opening with grill integrated into the enclosure. Without feet. Air intake on the front side; air outlet on the narrow side. For recirculated-air operations with wall, ceiling, or floor installation. With feet intake-air opening without grill. Air intake on the front side air outlet on the front side. For recirculated-air operations with wall, ceiling, or floor installation. With feet. Intake-air opening without grill. Air intake on the front side air outlet on the narrow side. For recirculated- or mixed-air operations with wall, ceiling, or floor installation. With feet. Mixed-air intake opening integrated with grill. Intake of outside air on the rear side, without grill. Air intake on the front side air outlet on the front side. For recirculated- or mixed-air operations with wall, ceiling, or floor installation. With feet. Mixed-air intake opening integrated with grill. Intake of outside air on the rear side, without grill. 1 4 5 6 7 8 PR-2008-0305-GB We reserve the right to make changes without notice Version: 09/2008 7

GEA MATRIX intelligent control technology Just the right turn for the right room climate If requested as option, the proven GEA MATRIX control unit will be integrated into the GEA Flex fan coil units at the factory. Your benefit: only completely tested equipment will be supplied to your construction site. Comprehensive control possibilities: GEA MATRIX is available in configuration levels 500, 2000, 3000, or 4000, with adaptation to the various possible applications. A version can be supplied for hotel applications, for example: as well as a Basic version for cost-optimised budgets. Control functions in various expansion stages Bus interfaces to other equipment units Plug-and-play functionality Energy-optimised equipment operation Equipment ready to operate Highly competent service Global add-on modules LON interface Service tool Most of the versions are provided as default with the two-cable GEA MATRIX dual-cable bus system, through which all GEA MATRIX units can communicate with each other. As a result, it is simple to implement daytime and nighttime switching actions, or to control pumps and collect error messages at a single point. GEA MATRIX can also be connected to higher-level bus systems. In addition, GEA MATRIX assures energy-optimized operation of GEA Flex fan coil units. A coordinated switch-over function, for example, prevents heating and cooling circulation systems from working against each other. By means of the summer compensation function, GEA MATRIX takes outside-temperature influences into account and prevents energy-intensive climate control. Hardware and software are developed entirely at GEA. As a result of close collaboration in the company, GEA engineers can systematically adjust the control system to match every component and in turn optimally exploit the possibilities of the fan coil units. GEA support staff also profit from this arrangement by being able to quickly and expertly react in case of any questions. Numerous additional global modules are available as function expansions of the standard local connections. Examples here are: intra-group GEA MATRIX control units and clock modules, modules for activation control of exhaust-air fans and chillers, expansion of analogue or digital input and output signals, 0 10-V outputs for valves, and integration into a LON bus system in accordance with the LonWorks standard. Starting with MATRIX 2000, all modules can be simply integrated via the MATRIX.Net bus system. In addition, the service tools MATRIX.PDA and MATRIX.PC can be used for parameterisation, facility commissioning, maintenance, and data recording from the MATRIX control system. 8 PR-2008-0305-GB We reserve the right to make changes without notice Version: 09/2008

Control unit for MATRIX 500 Control unit for MATRIX 2000 MATRIX OP5 MATRIX OP21 Enclosure without display, pure white Recirculated-air mode, IP 20 protection class Desired-temperature setting Fan-speed selection for permanent duty Button for temperature-reduction mode LED for operation/malfunction/ext. influence Integrated room-temperature sensor Same as the OP5 control unit, but with: Fan-speed selection switch for permanent / automatic operation MATRIX.Net data bus Network connection for MATRIX add-on modules via OP21 control unit Control units for MATRIX 3000 and MATRIX 4000 MATRIX OP30 without buttons MATRIX OP31 with temp.-reduction button Enclosure without display, pure white Recirculated-air, IP 20 protection class Desired-temperature setting Fan-speed selection switch for permanent / automatic operation LED for operation/malfunction/ext. influence Integrated room-temperature sensor MATRIX OP44 Same as the OP31 control unit, but with: Selection switching for heating / cooling / automatic operation Selection switching for recirculated-air / mixed-air modes of operation All units without display. Protective hood as option. MATRIX OP50 without clock MATRIX OP51 with clock Enclosure without display, pure white Recirculated-air / mixed-air modes of operation IP 20 enclosure protection class Operation by rotary navigator LCD display with plain text Status report by pictograms MATRIX.IR infrared remote control unit Functions as for the OP44 control unit, but: Without operational/malfunction reports Without report of external influence Without integrated room sensor Black enclosure, similar to RAL 9004 LCD display, 45 x 30 mm Effective range = approx. 20 m Integrated room-temperature sensor GEA thermostat / compact switch units CMS / CMT / CET series: extremely simple control units are also available for minimal control-function requirements (for systems based on pumped hot water and pumped cold water). PR-2008-0305-GB We reserve the right to make changes without notice Version: 09/2008 9

Overview of systems and performance ratings GEA Flex-Geko Air Heating Cooling Basic Edition Installed sizes flow rating rating Fan speeds 1-2 - 3 1... 8 in m 3 / h in kw in kw Recirculated air Typ Performance rating min max min max min max Pumped hot water / pumped cold water Heating with pumped hot water U0W 1 180 1800 2.0 19.5 Cooling with pumped cold water UW0 1 180 1800 1.1 10.7 Cooling with pumped cold water or heating with pumped hot water (change over) Cooling with pumped cold water and heating with pumped hot water (4-pipe system) UWC 1 180 1800 2.0 19.5 1.1 10.7 UWW 1 175 1780 0.7 7.0 1.1 9.1 See pages 12 and 13 for the output ratings in the individual fan-speed levels. Air Heating Cooling Comfort-Edition Installed sizes flow rating rating Fan speeds 1-2 - 3 1... 8 in m 3 / h in kw in kw Recirculated air / mixed air Typ Performance rating min max min max min max Pumped hot water / pumped cold water Heating with pumped hot water U0W / M0W 1 150 1820 1.7 19.6 Cooling with pumped cold water UW0 / MW0 1 150 1820 1.0 10.8 Cooling with pumped cold water or heating with pumped hot water (change over) Cooling with pumped cold water and heating with pumped hot water (4-pipe system) UWC / MWC 1 150 1820 1.7 19.6 1.0 10.8 UWW / MWW 1 145 1800 0.6 7.2 1.0 9.1 Pumped hot water / pumped cold water / electrical heating Electrical heating U0E / M0E 1 270 1820 2.1 12.4 Heating with pumped hot water + 2.3 18.1 U0F / M0F 1 220 1820 electrical booster heating 0.9 4.1 Cooling with pumped cold water or heating 2.3 18.1 UWB / MWB 1 220 1820 with pumped hot water + electrical heating 0.9 4.1 1.2 9.6 Cooling with pumped cold water and heating with electrical heating UWE / MWE 1 220 1820 0.9 4.1 1.2 9.6 Cooling and heating with cold and hot water UWF 0.9 7.2 1 215 1800 (4-pipe system) + electrical heating (only recirculated air) 0.9 4.1 1.2 7.6 Refrigerant: R410A / pumped hot water Cooling with R410A refrigerant UD0 / MD0 1 270 1820 1.2 7.1 Cooling with R410A refrigerant and heating with pumped hot water UDW / MDW 1 270 1800 1.0 7.2 1.0 4.9 Heating with pumped hot water: 70/50 C, tl1 +20 C; cooling with pumped cold water: 6/12 C, tl1 +27 C, 46% relative humidity; refrigerant: R410A, to +10 C See page 11 for data on the sound emission *The U s in the Type column above stand for recirculated air. M stands for mixed air 10 PR-2008-0305-GB We reserve the right to make changes without notice Version: 09/2008

GEA Flex-Geko Noise emission in db(a) Basic Edition installed sizes 1 2 3 4 5 6 7 8 Fan speeds 1-2 - 3 At air flow of: Fan speed 1 m 3 / h 180 190 330 380 400 520 570 590 Acoustic power level Lw 33 33 33 35 35 36 36 36 Acoustic pressure level* Lp * 24 24 24 26 26 27 28 27 At air flow of: Fan speed 2 m 3 / h 260 290 490 540 560 740 790 940 Acoustic power level Lw 41 43 44 44 44 44 45 45 Acoustic pressure level* Lp * 33 34 35 35 35 35 36 37 At air flow of: Fan speed 3 m 3 / h 490 520 860 960 990 1310 1410 1800 Acoustic power level Lw 57 57 59 60 60 62 62 63 Acoustic pressure level* Lp * 48 49 51 51 51 54 53 54 Comfort Edition installed sizes 1 2 3 4 5 6 7 8 Fan speeds 1-2 - 3-4 - 5 At air flow of: Fan speed 1 m 3 / h 150 160 280 290 300 430 460 590 Acoustic power level Lw < 30 < 30 30 < 30 < 30 33 33 34 Acoustic pressure level* Lp * 21 < 20 21 20 < 20 24 24 25 At air flow of: Fan speed 3 m 3 / h 270 280 470 490 520 750 770 970 Acoustic power level Lw 42 42 43 41 42 46 46 46 Acoustic pressure level* Lp * 33 33 34 32 34 38 38 37 At air flow of: Fan speed 5 m 3 / h 530 540 890 990 1010 1310 1420 1820 Acoustic power level Lw 58 58 59 58 59 62 62 61 Acoustic pressure level* Lp * 50 49 51 50 51 54 53 53 * Conditions for measurement of acoustic pressure level Lp: Measuring interval = 5 m. Room volume = 100 m³. Reverberation period = 0.5 s. Directional factor = 4 (quarter-sphere sound emission) PR-2008-0305-GB We reserve the right to make changes without notice Version: 09/2008 11

Performance ratings Basic Edition Basic Edition Installed size 1 2 3 4 5 6 7 8 Capacity stage 1 Min. fan-speed level = 1 2 pipes Air flow m 3 / h 180 190 330 380 400 520 570 590 Heating U0W / UWC kw 2.0 2.3 3.6 4.3 4.7 5.6 6.3 6.8 Cooling UW0 / UWC kw 1.1 1.2 1.9 2.4 2.7 3.0 3.4 3.7 4 pipes Air flow m 3 / h 175 185 325 370 390 515 565 585 Heating UWW kw 0.7 1.1 1.8 2.3 2.5 3.2 3.7 3.9 Cooling UWW kw 1.1 1.2 2.0 2.4 2.5 3.3 3.7 3.8 Max. fan-speed level = 3 2 pipes Air flow m 3 / h 490 520 860 960 990 1310 1410 1800 Heating U0W / UWC kw 3.8 4.6 6.7 7.9 8.8 10.5 11.6 14.3 Cooling UW0 / UWC kw 1.9 2.3 3.4 4.1 4.6 5.2 5.9 7.2 4 pipes Air flow m 3 / h 485 515 850 945 975 1300 1395 1780 Heating UWW kw 1.4 1.9 3.0 3.7 4.2 5.3 5.9 7.1 Cooling UWW kw 1.9 2.2 3.5 4.2 4.4 5.7 6.3 7.2 Basic Edition Installed size 1 2 3 4 5 6 7 8 Capacity stage 2 Min. fan-speed level = 1 2 pipes Air flow m 3 / h 175 185 325 370 390 515 565 585 Heating U0W / UWC kw 2.2 2.6 4.2 5.0 5.4 6.7 7.4 7.9 Cooling UW0 / UWC kw 1.2 1.5 2.3 2.8 3.2 3.5 4.1 4.5 4 pipes Air flow m 3 / h 170 185 310 345 370 500 545 570 Heating UWW kw 0.9 1.2 1.9 2.2 2.5 3.0 3.4 3.7 Cooling UWW kw 1.1 1.4 2.1 2.6 2.9 3.3 3.7 4.1 Max. fan-speed level = 3 2 pipes Air flow m 3 / h 485 515 850 945 975 1300 1395 1780 Heating U0W / UWC kw 4.7 5.6 8.5 9.9 10.8 13.1 14.6 17.9 Cooling UW0 / UWC kw 2.4 3.1 4.4 5.4 6.0 6.8 7.7 9.6 4 pipes Air flow m 3 / h 470 505 815 890 920 1255 1350 1700 Heizen UWW kw 1.6 2.2 3.3 3.9 4.4 5.1 5.8 7.0 Cooling UWW kw 2.2 2.9 4.2 5.0 5.6 6.4 7.3 9.1 Basic Edition Installed size 1 2 3 4 5 6 7 8 Capacity stage 3 Min. fan-speed level = 1 2 pipes Air flow m 3 / h 170 185 310 345 370 500 545 570 Heating U0W / UWC kw 2.4 2.6 4.4 5.0 5.4 6.8 7.6 8.1 Cooling UW0 / UWC kw 1.3 1.5 2.5 2.9 3.3 3.5 4.1 4.6 Max. fan-speed level = 3 2 pipes Air flow m 3 / h 470 505 815 890 920 1255 1350 1700 Heating U0W / UWC kw 5.2 6.0 9.4 10.6 11.6 14.3 15.8 19.5 Cooling UW0 / UWC kw 2.9 3.3 5.2 6.0 6.5 7.6 8.6 10.7 Heating with pumped hot water: 70/50 C, tl1 +20 C; cooling with pumped cold water: 6/12 C, tl1 +27 C, 46% relative humidity 12 PR-2008-0305-GB We reserve the right to make changes without notice Version: 09/2008

Comfort Edition Performance ratings Comfort Edition Installed size 1 2 3 4 5 6 7 8 Capacity stage 1 Min. fan-speed level = 1 2 pipes Air flow m 3 / h 150 160 280 290 300 430 460 590 Heating U0W / UWC kw 1.7 2.0 3.2 3.5 3.7 4.9 5.4 6.8 Cooling UW0 / UWC kw 1.0 1.1 1.7 2.0 2.1 2.6 2.9 3.7 4 pipes Air flow m 3 / h 145 155 275 285 295 425 455 575 Heizen UWW kw 0.6 1.0 1.7 1.9 2.1 2.9 3.2 3.9 Cooling UWW kw 0.9 1.0 1.8 2.0 2.0 2.8 3.2 3.7 Max. fan-speed level = 5 2 pipes Air flow m 3 / h 530 540 890 990 1010 1310 1420 1820 Heating U0W / UWC kw 3.9 4.7 6.8 8.1 8.8 10.5 11.7 14.4 Cooling UW0 / UWC kw 2.0 2.4 3.4 4.1 4.7 5.2 5.9 7.3 4 pipes Air flow m 3 / h 525 535 880 980 1000 1295 1405 1800 Heating UWW kw 1.4 2.0 3.1 3.7 4.2 5.3 5.9 7.2 Cooling UWW kw 2.0 2.3 3.5 4.3 4.5 5.7 6.4 7.3 Comfort Edition Installed size 1 2 3 4 5 6 7 8 Capacity stage 2 Min. fan-speed level = 1 2 pipes Air flow m 3 / h 145 155 275 285 295 425 455 575 Heating U0W / UWC kw 1.9 2.2 3.7 4.0 4.3 5.7 6.2 7.8 Cooling UW0 / UWC kw 1.0 1.3 2.1 2.3 2.6 3.0 3.5 4.4 4 pipes Air flow m 3 / h 145 155 265 280 290 415 445 545 Heating UWW kw 0.8 1.0 1.7 2.0 2.1 2.7 3.0 3.6 Cooling UWW kw 1.0 1.2 1.9 2.2 2.4 2.7 3.1 4.0 Max. fan-speed level = 5 2 pipes Air flow m 3 / h 525 535 880 980 1000 1295 1405 1800 Heating U0W / UWC kw 5.0 5.8 8.8 10.1 11.0 13.1 14.6 18.1 Cooling UW0 / UWC kw 2.5 3.1 4.5 5.5 6.1 6.8 7.8 9.6 4 pipes Air flow m 3 / h 510 525 845 950 975 1245 1360 1710 Heating UWW kw 1.7 2.2 3.3 4.0 4.5 5.1 5.8 7.0 Cooling UWW kw 2.3 3.0 4.3 5.2 5.8 6.4 7.4 9.1 Comfort Edition Installed size 1 2 3 4 5 6 7 8 Capacity stage 3 Min. fan-speed level = 1 2 pipes Air flow m 3 / h 145 155 265 280 285 415 445 545 Heating U0W / UWC kw 2.0 2.2 3.8 4.1 4.3 5.7 6.4 7.7 Cooling UW0 / UWC kw 1.2 1.3 2.2 2.4 2.6 3.1 3.4 4.4 Max. fan-speed level = 5 2 pipes Air flow m 3 / h 510 525 845 950 970 1245 1360 1710 Heating U0W / UWC kw 5.5 6.2 9.6 11.1 12.0 14.2 15.9 19.6 Cooling UW0 / UWC kw 3.0 3.4 5.3 6.2 6.7 7.6 8.7 10.8 Heating with pumped hot water: 70/50 C, tl1 +20 C; cooling with pumped cold water: 6/12 C, tl1 +27 C, 46% relative humidity. Models with different output ratings are available upon request for systems with electrical heating and direct evaporators. PR-2008-0305-GB We reserve the right to make changes without notice Version: 09/2008 13

Base units dimensions and weights (mass) GEA Flex-Geko Comfort Basic Comfort Installation Recirculated air Mixed air weight weight sizes mm mm mm mm kg kg Wall units 225 Height Height Width Depth Max Max 471 1 470 596 761 225... 237 13 18 2 470 596 911 225... 237 14 22 3 470 596 1061 225... 237 18 27 4 470 596 1211 225... 237 21 32 5 470 596 1361 225... 237 24 36 6 470 596 1511 225... 237 28 42 R e c i rc u l ate d a i r B a sic a nd Comfort 225 (228**) 35 108 471 125 7 470 596 1661 225... 237 30 46 8 470 596 1881 225... 237 35 52 Mixed air Comfort Edition The dimensions of the recirculated-air unit with 125-mm supporting feet are the same as those of the mixed-air unit. Enclosures dimensions and weights (mass) Comfort Basic Comfort Installation Recirculated air Mixed air weight weight sizes mm mm mm mm kg kg Height Height Width Depth Max Max Enclosures Basic and Comfort Editions Recirculated-air wall unit 1 504 629 840 240 9 9 2 504 629 990 240 10 10 1 240 3 504 629 1140 240 11 11 4 504 629 1290 240 12 12 5 504 629 1440 240 13 13 6 504 629 1590 240 14 14 7 504 629 1740 240 15 15 8 504 629 1890 240 16 16 The dimensions of the recirculated-air unit with 125-mm supporting feet are the same as those of the mixed-air unit. Without feet; without intakeair grill 5 With feet; without intake-air grill 7 504 240 504 629 125 240 504 629 104 125 With feet; with intake-air grill Enclosures Comfort Edition Recirculated-air wall unit Enclosures Comfort Edition Mixed-air wall unit 240 4 6 7 8 240 120 120 240 240 120 504 92 504 629 629 504 104 629 504 104 125 125 125 Without feet; with intake-air grill in the enclosure With feet; without intake-air grill With feet; with intake-air grill Air outlet on narrow side With feet; with intake-air grill Air outlet on front side 14 PR-2008-0305-GB We reserve the right to make changes without notice Version: 09/2008

GEA Flex-Geko Enclosures without supporting feet Intake-air and outlet-air variations Recirculated Outlet-air grill Outlet-air grill Wall and ceiling models air-units of plastic of aluminium Comfort I Basic Δ For views, see page 7 Adjustable Not adjustable Intake narrow side Outlet narrow side Intake narrow side Outlet front side Intake front side Outlet narrow side Intake front side Outlet front side Intake front side Outlet narrow side With cover panel Intake front side Outlet narrow side With rear-wall panel 41 2 3 4 3 3 Enclosures with supporting feet Intake-air and outlet-air variations Mixed-air Recirculated Outlet-air grill Outlet-air grill Wall and ceiling models units air-units of plastic of aluminium Comfort I Basic Δ For views, see page 7 Adjustable Not adjustable Intake front side Outlet narrow side Without intake grill Intake front side Outlet front side Without intake grill Intake front side Outlet narrow side With intake grill Intake front side Outlet front side With intake grill 5 6 7 8 Accessories Accessories Air-intake side Wall and ceiling models Comfort I Basic Δ Intake-air box with primary-air fittings Intake-air box with round intake fittings DN 200 enclosure cover for round fittings Intake-air bend Intake-air sailcloth fittings Connection piece for intake-air sailcloth fittings Intake-air telescopic fittings Intake-air noise suppressor for recirculated-air Intake-air noise suppressor for mixed-air units Built-in wall frame for fresh-air fittings Weather-protection grill, RAL 9002, painted Built-in wall frame for weather-protection grill Spare filter, G1 Spare filter, G2, G3 Outlet-air side Wall and ceiling models Comfort I Basic Δ Outlet-air box with primary-air fittings, not insulated Outlet-air box with primary-air fittings, insulated Outlet-air box with round outlet-air fittings, not insulated Outlet-air box with round outlet-air fittings, insulated DN 200 enclosure cover for round fittings Air-outlet bend, not insulated Air-outlet bend, insulated Outlet-air sailcloth fittings Telescopic outlet-air fittings Outlet-air noise-suppressor fittings Image brochure Application brochures Product brochures Data & Facts and operation manuals (available only as PDF) You are on this level of our documentation structure. You can order at no charge from the first 3 levels as printed copies, under: info@gea-airtreatment.com. You can download all brochures as PDF files from the following Internet site: www.gea-airtreatment.com. PR-2008-0305-GB We reserve the right to make changes without notice Version: 09/2008 15

Customer proximity, sales structures Reachable always and everywhere! A B BG BIH BY CH CZ CZ D D D GEA Klimatechnik GmbH & Co KG A-4673 Gaspoltshofen Tel. +43 / 7735 / 8000-0 GEA Happel Belgium N. V. B-1130 Brussels Tel. +32 / 2 / 2406161 EVISS Ltd. BG-7000 Rousse Tel. +359 / 82 / 81000 GEA Klimatechnik GmbH & Co KG RS-11070 Novi Beograd Tel. +381 / 11 / 3193955 GEA Klimatechnik UAB LT-01141 Vilnius Tel. +370 / 5 / 2106060 ATC Klimatec Schweiz AG CH-3065 Bolligen-Station Tel. +41 / 31 / 9171919 GEA LVZ, a.s. CZ-46312 Liberec Tel. +420 / 48 / 5225-111 GEA Klimatizace spol. s r.o. CZ-46312 Liberec Tel. +420 / 48 / 5225-303 GEA Happel Klimatechnik GmbH D-44625 Herne Tel. +49 / 2325 / 468-00 GEA Happel Wieland GmbH D-44625 Herne Tel. +49 / 2325 / 468-754 GEA Deichmann Umwelttechnik GmbH D-36179 Bebra Tel. +49 / 6622 / 504-0 The complete addresses are available on the Internet under: www.gea-air-eco2nomy.com. D D DK E EST F F FIN GB GEA Delbag Lufttechnik GmbH D-44625 Herne Tel. +49 / 2325 / 468-700 GEA Delbag-Luftfilter Vertriebsgesellschaft mbh D-10709 Berlin Tel. +49 / 30 / 43592-3 GEA Klimateknik ApS DK-2610 Rødovre Tel. +45 / 38 / 887070 GEA Air Treatment Marketing Services Int. GmbH oficina España E-28036 Madrid Tel. +34 / 91 / 3837701 GEA Klimatechnik UAB LT-01141 Vilnius Tel. +370 / 5 / 2106060 GEA Delbag Filtration de l air F-77450 Montry Tel. +33 / 1 / 60043355 GEA Happel France sarl F-59436 Roncq Cedex Tel. +33 / 3 / 20689020 OY TEKNOCALOR AB FIN-01300 Vantaa Tel. + 358 / 10 / 8201100 GEA Denco Ltd. UK-HR4 8DS Hereford Tel. +44 / 1432 / 277 277 H HR IE IS L LT LV MWE N NL GEA Klimatechnika Kft H-1037 Budapest Tel. +36 / 1 / 4393200 GEA Klima-rashladna tehnika d.o.o. HR-10000 Zagreb Tel. +385 / 1 / 6064900 Aspect Environmental Ltd. Ardee, Co. Louth Ireland Tel. +353 / 41 / 6858983 Rafn Jensson IS-110 Reykjavik Tel. +354 / 56 / 780-30 GEA Happel Luxembourg L-4940 Bascharage Tel. +352 / 26 / 502970 GEA Klimatechnik UAB LT-01141 Vilnius Tel. +370 / 5 / 2106060 GEA Klimatechnik UAB LT-01141 Vilnius Tel. +370 / 5 / 2106060 GEA Klimatechnik GmbH & Co KG RS-110 70 Novi Beograd Tel. +381 / 11 / 3193955 GEA Klimaprodukter AS N-0484 Oslo Tel. +47 / 220 / 27990 GEA Happel Nederland B.V. NL-2909 LL Capelle a/d Ijssel Tel. +31 / 10 / 2350606 P PL RO RUS S SK SLO SRB TR UA UAE Nónio, Lda. P-1269-090 Lisboa Tel. +351 / 21 / 3826160 GEA Klimatyzacja Sp. z o.o. PL-54610 Wroclaw Tel. +48 / 71 / 3737952 GEA Klimatechnik s.r.l. RO-300222 Timisoara Tel. +40 / 356 / 423703 GEA Klimatechnik GmbH & Co KG RU-105094 Moskva Tel. +7 / 495 / 9566674 GEA EXOS Ventilation AB S-74528 Enköping Tel. +46 / 171 / 85530 GEA Klimatizácia s.r.o. SK-83104 Bratislava Tel. +421 / 7 / 44457917 GEA Klimatizacijska Tehnika d.o.o. SI-1000 Ljubljana Tel. +386 / 1 / 2573850 GEA Klimatechnik GmbH & Co KG RS-11070 Novi Beograd Tel. +381 / 11 / 3193955 GEA ISISAN TR-80700 Balmumcu Istanbul Tel. +90 / 212 / 2757171 GEA Ukraina t.o.v. UA-01135 Kyiv Tel. +38 / 044 / 4619356 GEA Air Treatment Middle East UAE-Dubai Tel. +971 / 4 / 887 3881 VDI 6022 (D) Tested room-air hygiene Seal of hygiene SWKI VA 104-01 (CH) Tested by ILH BERLIN PR - 2008-0305-GB Subject to modification Issue 09/2008 Copyright GEA Air Treatment www.gea-air-eco2nomy.com