13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

OOH740-A9-Ex Multisensor fire detector

OOH740-A9-Ex Multi-sensor fire detector

Input module, input/output module

Input module, input/output modules

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

Multi line separator module

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

ASA linear smoke detector

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

Output module (230 V)

OH110, OP110, HI110 Automatic fire detectors

Interbases. Sinteso FDSB221, FDSB228, FDSB229

FDBZ290 Air sampling smoke detection kit

FDBZ290 Air sampling smoke detection kit

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

Mimic display driver, LED ribbon cable

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

FDCIO223 (ES 45) Transponder

DT1101A / DT1102A / DO110xA Automatic fire detectors

Fire control panels FC360

OH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual

Radio fire detection system

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

SWING radio fire detection system

DM1131 / DM1133 / DM1134 Manual call points

FDCL221-M Multi line separator module

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

Test units and accessories

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

Fire control panels FC726 FC726-XA

FC723 Fire control panel

FC724 Fire control panel

FDBZ290 Air sampling smoke detection kit Technical Manual

FC722 Fire control panel

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

FC724 Fire control panel

FC2040. Fire control panel. Sinteso. FS20 series, MP6

DC1192 Input /Output module

FC722 Fire control panel

OH110, OP110, HI110. Automatic Fire Detectors. Automatic Fire Detector For collective and conventional detector lines

FDCW241 Radio gateway Mounting

DF1101-Ex Infrared flame detector

Fire control panel for modernization

FDOOT221, FDOOT241-A3, FDOOT241-A4, FDOOT241-8, FDOOT241-9, FDOOT241-A9, FDO241, FDO221, FDT241, FDT221 Automatic fire detectors Technical Manual

DOW1171 / DCW1151 Radio fire detection system

FT2080 Fire terminal (Touch) Mounting Installation

FT2080 Fire terminal (Touch) Mounting Installation

FDOOT241-A9-Ex Automatic fire detector Technical Manual

FDCL221-Ex Line adapter (Ex)

FDCL221 Line separator

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Test units and accessories

Synova TM product catalog.

Model OOHC941 ARCHITECT AND ENGINEER SPECIFICATIONS Advanced multi-criteria fire detector that has optical, thermal and CO sensors

FDL241-9 Linear smoke detector Mounting Commissioning

FC2020 Fire control panel

Room thermostat with 24-hour time switch and large LCD

Intelligent Detection Devices

Fire & Security Products. Siemens Building Technologies Group

DF1151-Ex Infrared flame detector

FDS229 Alarm sounder with supplementary optical indication Technical Manual

Cerberus FIT conventional system

FDM273 Radio manual call point Mounting

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

CerberusTM. PRO intelligent protection. A comprehensive fire protection system. Answers for infrastructure.

FD20 Sinteso Detector system

Call stations and extensions

FS20 Fire detection system

FDA241, FDA221 Siemens ASD

FS720 Fire detection system (marine) Technical Manual

Test units and accessories

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

ARCHITECT AND ENGINEER SPECIFICATIONS

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 3: Audible alarm devices

Electronic timeswitch

XC10 combined fire detection and extinguishing control

Cerberus PRO enjoy protecting A comprehensive fire protection system

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

FDCI221, FDCIO221 Input module, input/output module Technical Manual

XC10 combined fire detection and extinguishing control

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

FP120-Z1 Power supply kit A (70 W) Technical Manual

FDA241, FDA221 Siemens ASD

Sinteso TM product catalog.

Fire protection for emergency power supply

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 16: Sound system control and indicating equipment

FC700A Fire detection control unit

Building Technologies. FDUL221 en Line tester operating instructions for electricians

RVL479. Heating Controller. for use with a partner unit

Transcription:

Cerberus PRO OOH740, OOHC740 Automatic fire detectors ASAtechnology For the automatically addressable detector bus C-NET collective / conventional (OOH740 only) Signal processing with ASAtechnology Event-controlled detection behavior Evaluation of the criteria heat, warmth for OOH740, and gas for OOHC740 Quick response to all fires that generate carbon monoxide (CO) for OOHC740 Separate detection of toxic CO for OOHC740 Highly developed immunity to deceptive phenomena Prepared for future requirements thanks to its programmability Address automatically issued during commissioning 2017-10-31 Control Products and Systems

Properties Design Resistant to environmental and interfering influences such as dust, fibers, insects, moisture, extreme temperatures, electromagnetic interference, corrosive vapors, vibration, artificial aerosols, and atypical fire phenomena Features Shock resistant, protection against sabotage Signal processing with ASAtechnology (Advanced Signal Analysis) Time and process-dependent detection behavior High degree of immunity to faults in power electronics Protected electronics, high-quality components Sophisticated sensors and electronic monitoring The integrated line separator that locates the defective part on the detector bus of the control panel and isolates between two detectors Integrated alarm indicator (AI), 360 visibility Up to two external alarm indicators can be connected per detector Address automatically issued during commissioning Same detector base can be used for every detector type, for surface-mounted and recess-mounted supply lines OOH740 only: Can also be used on a collective detector line or a conventional detector line Eco-friendly Environmentally friendly processing Reusable materials Electronic parts and synthetic materials can be easily separated Use OOH740 multi-sensor fire detector, neural ASA Multi-sensor fire detector consisting of: Point detector Detector dust cap to protect the point detector during the construction phase Functions according to the scattered light principle with two sensors, optical forward and backward scattering Opto-electronic measuring chamber that obstructs disruptive extraneous light but provides excellent detection of both light and dark smoke particles Two additional heat sensors increase the point detector's immunity to deceptive phenomena Can be set as a multi-sensor smoke detector, smoke detector, or heat detector by the software Selectable detection behavior thanks to application-specific ASA parameter sets For early detection of flaming fires of solid and liquid substances, as well as of smoldering fires For early and reliable fire detection in an environment with deceptive phenomena Can be used on an addressed detector line, a collective detector line, or a conventional detector line 2

OOHC740 fire and CO detector, neural ASA Multi-sensor fire detector consisting of: Point detector Detector dust cap to protect the point detector during the construction phase Functions according to the scattered light principle with two sensors, optical forward and backward scattering Opto-electronic measuring chamber that obstructs disruptive extraneous light but provides excellent detection of both light and dark smoke particles Two additional heat sensors and an additional CO sensor increase the point detector's response behavior and immunity to deceptive phenomena Technical message, ambient supervision: Technical message if the temperature or CO concentration exceeds/falls below the preset limits Functions using an electro-chemical CO cell CO concentration alarm is transmitted to an independent technical CO alarm channel Independent processing of the CO signal for the CO alarm channel and CO signal for fire detection Selectable detection behavior of the CO alarm channel, regardless of ASA parameter sets for fire detection Selectable detection behavior thanks to application-specific ASA parameter sets For early detection of smoldering fires that generate CO (e.g., mattress fires in homes) Areas with increased CO exposure, e.g., heating rooms, combustion plants, fermentation plants, garages, automotive workshops, animal stalls, chemical laboratories, or production sites For reliable fire detection in an environment with deceptive phenomena Can be used addressed Detector base DB721 Universal base for all point detectors of the Cerberus PRO FD720 series For recess-mounted supply lines For surface-mounted supply lines with cables up to max. Ø 8 mm The detector base DB721 has a loop contact. When using the DB721, the detector line is also not interrupted when there is no point detector mounted in the detector base. 3

Detector base DB721D Collective mode Universal base for the point detector OOH740 in collective mode (with BS 5839-1) Addressed mode Universal base for the point detector OOH740 of the Cerberus PRO FD720 series When used in the addressed mode, the diode must be removed For recess-mounted supply lines For surface-mounted supply lines with cables up to max. Ø 8 mm The detector base DB721D has a loop contact. When using the DB721D, the detector line is also not interrupted when there is no point detector mounted in the detector base. Detector base DB722 Universal base with base seal for point detectors OH720 and OP720 of the Cerberus PRO FD720 series For recess-mounted supply lines For surface-mounted supply lines with cables up to max. Ø 8 mm The detector base DB722 has a loop contact. When using the DB722, the detector line is also not interrupted when there is no point detector mounted in the detector base. Detector base DB110 (parameter set 1) Universal base for all point detectors of the 110 and OOH740 series Selects parameter set 1 within the point detector For recess-mounted supply lines For surface-mounted supply lines with cables up to max. Ø 8 mm Sounder base DBS720 Addressable sounder base for the acoustic alarm Compatible with all point detectors from the Cerberus PRO FD720 series You will find more information on the sounder base DBS720 in document A6V10218037. Intended use The automatic fire detectors OOH740 and OOHC740 may only be used on a C-NET detector line in a fire detection system FS720 or FC360. The automatic fire detector OOH740 may also be used on a collective detector line or a conventional detector line. 4

Type Overview Type Designation Order number Weight [kg] OOH740 Multi-sensor fire detector, ASA S54320-F7-A3 0,124 OOHC740 Fire and CO detector, ASA S54320-F8-A3 0,128 DB721 Detector base with loop contact S54319-F11-A1 0,052 DB721D Detector base with loop contact S54319-F15-A1 0,054 DB722 Detector base S54319-F19-A1 0,052 DB110 Detector base (collective) S54372-F5-A1 0,052 DBS720 Sounder base S54319-F5-A1 0,090 Accessories BA720 Base attachment S54319-F20-A1 0.051 BA721 Base attachment wet S54319-F29-A1 0,272 FDBZ291 Designation plate A5Q00002621 0,002 DBZ1193A Designation plate BPZ:4864330001 0.076 RS720 Detector base seal S54319-F8-A1 0,012 LP720 Detector locking device S54319-F9-A1 0,001 FDBH291 Detector heating unit A5Q00004439 0,015 DBZ1194 Protective cage BPZ:4677110001 0,138 DBZ1190-AA Micro terminal 0.28 0.5 mm² BPZ:4677080001 0,001 DBZ1190-AB Connection terminals 0.5 2.5 mm² BPZ:4942340001 0,001 PSR720-1 Parameter set resistor 33k S54319-F16-A1 0,001 PSR720-2 Parameter set resistor 68k S54319-F17-A1 0,001 Accessories Base attachment BA720 For routing surface-mounted ducts (max. 20 mm) and cable ducts (max. 25 x 15 mm) Detector base mounted quickly: The detector base clicks into place in base attachment BA720. Base attachment wet BA721 Base attachment wet with additional integrated rubber seal for mounting in wet or humid environments For achieving a higher protection category For mounting in wet or humid environments Required when using detector heating unit FDBH291 Required when using protective cage DBZ1194 Mounted between detector base and ceiling Detector base mounted quickly: The detector base simply clicks into place in base attachment wet BA721. 5

Protective cage DBZ1194 To protect the point detector from damage Can only be mounted in combination with base attachment wet BA721 Detector heating unit FDBH291 For operating point detectors in critical ambient conditions during icy conditions or when there is a danger of moisture condensation. Examples of application: Cold stores, attics, loading ramps, cheese cellars Optimum function is only guaranteed in conjunction with base attachment wet BA721. The point detector temperature increases by approximately 2 C over the operating temperature and thus avoids moisture condensation on the detector. Mounted quickly: The detector heating unit clicks into place in the detector base. Designation plate FDBZ291 For labeling with the location address Can only be used without detector base seal FDBZ295 Designation plate DBZ1193A For labeling with the location address Can only be used with base attachment wet BA721 Detector base seal RS720 For achieving a higher IP protection category Mounted between detector base and ceiling 6

Detector locking device LP720 For protection against theft of the point detector Set screw M3 x 12 mm prevents the point detector being unscrewed from the detector base Point detector can only be removed with the appropriate Allen key Parameter set resistor 33k PSR720-1 Prefabricated resistor with flat plugs for use in DB110 and DB721D. Brings the OOH740 in parameter set 1. Parameter set resistor 68k PSR720-2 Prefabricated resistor with flat plugs for use in DB110 and DB721D. Brings the OOH740 in parameter set 2. DBZ1190-AA micro terminal and DBZ1190-AB connection terminal Micro terminal DBZ1190-AA Cable cross section up to max. 0.5 mm² Connection terminal DBZ1190-AB Cable cross section up to max. 2.5 mm² For connecting two external alarm indicators or the cable shielding 7

Notes Installation Easy mounting Universal detector base Two break-out points for surface-mounted cable entry at the side. Max. cable diameter: 8 mm. Extra-large opening for single recess-mounted cable entry. Extra-long mounting slits allow existing drill holes from other systems to be reused. Screw terminals for conductors up to max. 1.6 mm² Space for auxiliary terminals: 2x micro terminals DBZ1190-AA and 2x connection terminals DBZ1190-AB The detector can be screwed into the base easily either manually or using the detector exchanger DX791 and the corresponding adapter FDUD491. The internal alarm indicator is centered in the detector, which makes alignment of the point detector superfluous. 2 3 1 1 4 6 7 3 5 1 Detector base 5 Mounting slits 2 Auxiliary terminals DBZ1190-AA, DBZ1190-AB 3 Screw terminals for detector line and external alarm indicator 4 Opening for cable entry 6 Point detector 7 Internal alarm indicator Disposal The device is considered an electronic device for disposal in accordance with the European Guidelines and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Dispose of empty batteries in designated collection points. 8

Technical data OOH740 OOHC740 Operating voltage (modulated) DC 12 33 V DC 12 33 V Operating current (quiescent) ~170...250 µa ~300...380 µa Max. number of external alarm indicators that can be connected 2 2 Operating temperature -25 +55 C -10...+50 C Storage temperature -30...+70 C -20...+55 C Air humidity (short-term moisture condensation permitted) 95 % rel. 95 % rel. Communication protocol C-NET, collective, or conventional C-NET Color ~RAL 9010 pure white ~RAL 9010 pure white Weight 0.100 kg 0.100 kg Protection category (IEC 60529) IP40 IP40 Protection category (IEC 60529) with detector base seal RS720/BA721 IP44 Standards CEA 4021, EN 54-5, EN 54-7, EN 54-17 Approvals VdS LPCB FM DNV GL (marine) G211070 126bh/05 3051081 45 246 16 HH IP44 CEA 4021, EN 54-5, EN 54-7, EN 54-17 G211047 126bh/06 - - Permissible wind speed Max. 5 m/s Max. 5 m/s C-NET system compatibility FC720, FC360 Collective system compatibility FC10/FC120-11 0786 OOH740 Siemens Switzerland Ltd; Gubelstrasse 22 CH-6301 Zug Technical data: see doc. A6V10305793 OOH740 - Smoke/heat detector incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-5 / EN 54-7 / EN 54-17 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0786-CPR-21094; DoC No.: CED-OOH740 11 0786 OOHC740 Siemens Switzerland Ltd; Gubelstrasse 22 CH-6301 Zug Technical data: see doc. A6V10305793 OOHC740 - Smoke/heat detector incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-5 / EN 54-7 / EN 54-17 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0786-CPR-21067; DoC No.: CED-OOHC740 9

Dimensional drawings 106 OOH740 106 OOHC740 43 43 OOH740 with base DB72x or DB110 117 OOHC740 with base DB72x 117 49 49 Product documentation Document ID Title 008115 Installation Detector heating FDBH291 A6V10200373 A6V10203222 A6V10218037 A6V10229261 A6V10305793 A6V10393192 A6V10406006 A6V10882301 Installation Detector base with loop contact DB721, DB722, detector base DB720, sounder base DBS720, detector base seal RS720, detector locking device LP720, base attachment BA720 Data Sheet Testequipment and accessories FDUL221, DX791, RE6, RE7T, RE8ST, RE8STCO, FDUM29x, LE3, StabexHF Technical Manual Sounder base DBS720 List of compatibility (for 'Cerberus PRO' product line) Technical Manual Automatic fire detectors OOH740, OOHC740 List of compatibility (for 'Cerberus FIT' product line) Installation Base attachment wet BA721, Detector designation plate DBZ1193A, Protective cage DBZ1194, EMC-protective cage FDBZ294 List of compatibility (for 'FC360' product line) Issued by Siemens Switzerland Ltd Division International Headquarters Gubelstrasse 22 CH-6300 Zug Tel. +41 58 724 2424 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2011 Technical specifications and availability subject to change without notice. 10 Document ID Manual FD720 Edition 2017-10-31 Register 2