LD920. User Manual. H2/N2 Tracer Gas Leak Detector. Detects 5% H2 in 95% Nitrogen Tracer Gas. Made in U.S.A. LeakDetectors-LD920-UserManual.

Similar documents
LD900. User Manual. Refrigerant Gas Leak Detector. Detects all HFO, HFC, HCFC, and CFC Refrigerants including blends. Made in U.S.A.

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

ATD-3698 Refrigerant Gas Leak Detector. Owner s Manual

Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

Operating Instructions. Model: LD3 Dual Mode Refrigerant Gas Leak Detector ROBINAIR.COM

Model: LD7 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

LD-5000 REFRIGERANT LEAK DETECTOR

LD 5000 REFRIGERANT LEAK DETECTOR JB INDUSTRIES INC.

YELLOW JACKET. ACCUPROBE UV and ACCUPROBE II Refrigerant Leak Detector with Heated Sensor. Instruction and Operation Manual

99 Washington Street Melrose, MA Phone Toll Free Visit us at

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

CLI Refrigerant Gas Leak Detector. User s Guide

OPERATING INSTRUCTIONS

Model 850 Investigator s Aid Accelerant and Gas Detector Operation and Maintenance

testo 316-EX gas leak detector Instruction manual

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

III. 99 Washington Street Melrose, MA Phone Toll Free Visit us at OPERATING INSTRUCTIONS

Model C Electronic Nose Accelerant and Gas Detector Operation and Maintenance

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

H-10PM. Refrigerant Leak Detector

NGD8800 USER S MANUAL

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

Instruction Manual Electronic Leak Detector. Bedienungsanleitung Elektronisches Lecksuchgerät. Mode d emploi Détecteur de fuites électronique

GAS-Mate. Combustible Gas Leak Detector

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

SENSIT HXG-2d Combustible Gas Detector

D-TEK Select. Refrigerant Leak Detector

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

Famous Trails Anaheim, California

User Manual. Humidity-Temperature Chart Recorder. Model RH520

REFRIGERANT LEAK DETECTOR

Refrigerant Leak Detector

Refrigerant / Combustibles Leak Detector

HI COD REACTOR and Test Tube Heater 2008 Series

RLD-H10P Refrigerant Leak Detector

Smoke Alarm User s Manual

TEK-Mate. Refrigerant Leak Detector

User Manual SF6 GASCHECK 6000

INSTRUCTION MANUAL CD Fax: (503)

User's Guide. Pinless Moisture Meter. Model MO257

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

For technical support call:

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

Operator's Manual. LIGHTNING 2 Laser Detector

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

RLD-H10G Refrigerant Leak Detectors

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

Portable Air Conditioner

TEK-Mate. Refrigerant Leak Detector

Visit us at

Instruction Manual MSI Sensit HXG

Water Tank Level Monitor

REFRIGERANT LEAK DETECTOR OPERATIONS MANUAL LD-170

WARNING Important Safety Information

OWNER S MANUAL. Fortune Finder Platinum Edition TC-3020 GET THE LATEST UPDATED MANUAL FOR THIS PRODUCT BY VISITING US FREQUENTLY AT

External Wireless Sounder

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

COMPUTHERM Q3 digital room thermostat

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

Combustible Gas Leak Detector Instruction Manual

The Professional Metal Detector OWNER S MANUAL

testo Leakage detector for refrigerants Bedienungsanleitung Instruction manual

aspida User Manual T: +44 (0) F: +44 (0) W: E:

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

Agrifim A675CT Timer. Frequently Asked Questions

How to use Medi-Therm III hyper/hypothermia system

LD200 / RLD400 LD200-G /RLD400-G

LS1. Operator Manual. Kane International Ltd

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET FEATURES

WIDE SEARCH AREA HAND-HELD METAL DETECTION SET

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

4-IN-1 PIN/PAD RH MOISTURE METER

SF 6 -Leak Pointer Operating Manual (original version) Type-No.: R002

This instruction manual explains the use of three models listed on the left.

PORTABLE DEW POINT MONITOR

CD100A COMBUSTIBLE GAS DETECTOR

USER MANUAL MINITRACER PORTABLE SNIFFER

Reacti-Therm I and III Heating Modules

SC Installation, Operation & Application Guide

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

User Manual. GPD 3000 e. gas detector

EVac II Programmable Digital Vacuum Gauge

Digital Cooking Thermometer models / 00282

Danfoss gas detection units

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET

CS150 OWNER S MANUAL DISCRIMINATOR METAL DETECTOR

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

Transcription:

LD920 H2/N2 Tracer Gas Leak Detector Detects 5% H2 in 95% Nitrogen Tracer Gas User Manual Made in U.S.A. LeakDetectors-LD920-UserManual.indd 1

INTRODUCTION The LD920 features a long life sensor technology that is designed to detect H2/N2 Tracer Gas mixture. Our unique digital leak size indicator takes the guesswork out of whether to repair a small leak. The digital display is independent from the audio alarm and sensitivity level, allowing the precise pinpointing of the leak source. When used with the H2/N2 Tracer Gas mixture, the LD920 will detect leak rates less than 5 ppm. The 5%H2/ 95%N2 Tracer Gas mixture is consistent with the teaching of EMC Directive 2014/30/EU for use with Low GWP Leak Detection System Tracer Gas. The LD920 does not require rechargeable batteries. FEATURES Unique numeric leak size Indicator Long life, stable sensor H2/N2 sensitivity <5 ppm Automatic calibration and reset to ambient Visual LED leak alarm near sensor 3 adjustable sensitivity levels Low battery indicator True mechanical pump Audio mute function Uses 4 AA alkaline batteries CE Certified Comfortable Sanoprene grip 2-year warranty includes sensor Made in USA 2 LeakDetectors-LD920-UserManual.indd 2

LD920 CONTROL PANEL Digital Leak Size Indicator Low Battery Indicator Sensitivity Level Indicators Audio Mute & Sensitivity Level Selectors Power On/Off OPERATING INSTRUCTIONS 1. TURN ON: Press the ON/OFF button once to turn on and again to turn off. NOTE: Hold button down for approximately 1 second to turn unit off. 2. WARM UP: The detector automatically starts heating the sensor. During the heating cycle, the digital leak size indicator will flash 0 and the detector will sound a slow beep. Warm up time is usually less than 20 seconds. 3. READY: The detector is ready to begin searching for leaks when the flashing 0 stops and the green sensitivity LED turns on. The audio beep increases in frequency and the probe LED begins to blink steadily. 4. SEARCHING: When searching for leaks, move the sensor tip along A/C lines and fittings no further away than 0.4 in. (9.5 mm) and no faster than 3 in./sec. (75 mm/sec.) If the detector alarms, make smaller sweeps back and forth until the leak source can be pin pointed. NOTE: The LD920 only responds to changes in leak concentration. The alarm will re-set automatically if the sensor tip is held at the leak source. If the leak detector has been out of use for an extended period, weeks or months, the following action is recommended. Power on the instrument and allow it to come out of warm up. Then run it with the sensitivity level in the Hi (high) position for several minutes before testing it with the Leak Test Vial. This action will guarantee that the sensor is fully conditioned for maximum response to tracer gas. 3 LeakDetectors-LD920-UserManual.indd 3

LEAK SIZE INDICATOR The digital leak size indicator remains off normally but once a leak is detected, a number from 1-9 will be displayed for all H2/N2 tracer gas regardless of the sensitivity setting. The number will continue to increase or decrease depending on the amount of tracer gas sensed. The maximum value will be displayed once the leak source has been located. The table below can be used to approximate the size of leak: Maximum # Approx. Leak Size Approx. Leak Size Displayed (oz/yr) (g/yr) 1-3 < 0.1 <3 4-6 0.1 to 0.5 3 to 14 7-9 >0.5 >14 LOW BATTERY INDICATOR Replace the 4 AA Alkaline batteries when the red LED on the control panel is lit. Follow battery installation instructions under Maintenance section. AUDIO MUTE FUNCTION To silence or mute the audio beep and alarm signal, press the MUTE button. To restore the audio sound, press the MUTE button again. (Note: a few seconds is required to restore sound if the mute button is pressed in rapid succession.) 4 LeakDetectors-LD920-UserManual.indd 4

ADJUSTING SENSITIVITY LEVELS The leak detector will default to the NORM sensitivity level automatically once the unit comes out of the warm up cycle and the green LED will turn on. To change sensitivity levels, press the SENS once for HI sensitivity (red LED will turn on) and again for LO sensitivity (yellow LED will turn on). LEAK TEST VIAL The leak detector includes a Leak Test Vial that allows the user to make sure the detector is performing properly. To test: 1. Remove the colored label dot in the center of the screw cap to expose the vent hole in the top of the screw cap. (see fig. below). 2. Turn on the leak detector and allow the instrument to complete the warm up cycle. 3. Place the sensor close to the small hole in the top of the Leak Test Vial. The beep rate should increase and the Digital Leak Size Indicator should display a number from 3-6 indicating that the sensor and the electronics are working properly. Remove label dot over vent hole before testing Vial cap with vent hole Expiration date on label NOTE: Replace the Test Vial back in the nylon bag when not in use to extend the shelf life. Replace Test Vial when the green color is less than ¼ full or at the time of the expiration date. 5 LeakDetectors-LD920-UserManual.indd 5

BATTERY MAINTENANCE Install Batteries: Remove screw located at rear end of unit and pull down hinged battery door to open as shown. Always insert all four batteries into the battery compartment in the same direction. Note: polarity mark on the inside of the battery door for proper battery orientation. Polarity mark SENSOR MAINTENANCE Replace Filter: Unscrew sensor tip as shown to replace filter. Replace filter whenever it becomes visibly dirty or every 2 to 3 months depending on use. Replace Sensor: Remove sensor by pulling out of socket. Install the new sensor by aligning the Keyway notch in sensor cover with the raised keyway on sensor socket holder (see figure below). Note: Do not force sensor into socket. Misalignment can damage the sensor pins. Unscrew tip to replace filter Filter Push straight on (do not twist) to install sensor Keyway alignment Pull straight out (do not twist) to remove sensor IMPORTANT: The instrument s software is designed to alert the user if the sensor is dislodged or defective. If the sensor is not fully inserted into the six-pin socket, or if it is defective, the instrument will not come out of the Warm Up mode for proper operation when the power button is turned on. Additionally, if the instrument becomes unstable during its operation, it is an indication that the sensor may be defective or dislodged. 6 LeakDetectors-LD920-UserManual.indd 6

PRODUCT SPECIFICATIONS Model # LD920 Name Sensitivity Sensor Life Response Time Power Supply Battery Life Warm up time Probe length Leak Detector, H2/N2 Tracer Gas < 5 ppm or 2 g/yr R134a equivalent > 300 hours Instantaneous 4 AA Alkaline batteries 4-6 hours continuous < 20 seconds 17 inches (43.8cm) Numerical Display 7 segment digital display (1 to 9) Weight, lbs. Warranty TRACER GAS DETECTION 1.5 lbs. (0.68kg) 2 years (includes sensor) Tracer Gas consists of a non-toxic, non-flammable, environmentally friendly (nonpolluting) mixture of 5% Hydrogen and 95% Nitrogen. For this reason, the Tracer Gas can be released into the environment after the leak detection procedure is completed. The 5%H2/95%N2 Tracer Gas mixture is consistent with the teaching of EMC Directive 2014/30/EU for use with Low GWP Leak Detection System Tracer Gas. The LD920 detects the Hydrogen component of the tracer and because Hydrogen molecules are so small, it is an ideal gas for leak detection. The Tracer Gas is charged into an empty system at a pressure of approximately 75 psi (5bar). As Hydrogen is lighter than air, always probe slightly above the suspected leak area. Once the source of the leak is located and repaired, the Tracer Gas can be released and the system can be recharged again with refrigerant. A final check should be performed using a certified refrigerant gas leak detector such as the Imperial LD900. NOTE: Run engine with air conditioner on briefly to properly distribute the H2/N2 Tracer Gas. 7 LeakDetectors-LD920-UserManual.indd 7

REPLACEMENT PARTS Item H2/N2 Sensor with Sensor Tip and Filter Sensor Filters (5 pack) Leak Test Vial Parts Kit (includes H2/N2 sensor with sensor tip, test vial, & filter kit) Carrying Case Sensor Tip with Filter Part Number S77704 S77695 S77705 S77706 S77707 S77698 WARRANTY The LD920 H2/N2 Tracer Gas Leak Detector is warranted to be free of defects in materials and workmanship for a period of two years from the date of purchase. This warranty applies to all repairable instruments that have not been tampered with or damaged through improper use including unauthorized opening of the unit. Tools should be returned to the buyer s place of purchase. SERVICE/TECHNICAL QUESTIONS CALL TOLL FREE: 888.467.8665 www.imperial-tools.com info@stridetool.com 30333 Emerald Valley Pkwy. Glenwillow, Ohio 44139 888.467.8665 LeakDetectors-LD920-UserManual.indd 1