TECHNICAL SUPPORT MANUAL Fan Coils FVM4X B Series

Similar documents
! CAUTION ! WARNING TABLE OF CONTENTS INTRODUCTION SAFETY CONSIDERATIONS

Service and Maintenance Instructions

WAHL A Product Specifications

REM4P, REM4X. Product Specifications

INSTALLATION INSTRUCTIONS

FEM4X. Product Specifications FAN COILS /14/15

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

FXM4X. Product Specifications FAN COILS FXM4X

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560)

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)

Model Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg)

INSTALLATION INSTRUCTIONS ELECTRIC HEAT ACCESSORY

Installation Instructions

Dimensions H x W x D in. (mm)

MULTI POSITION VARIABLE SPEED BLOWER MOTOR (ECM) SUP15-E230V1 SUP18-E230V1 SUP20-E230V1 SUP23-E230V2 SUP27-E230V2. Models: 240 VAC POWER SUPPLY

Cooling Capacity CFM in. w.c. (125 Pa)

Your safety and the safety of others are very important.

Installation Instructions

FCM4X. Product Specifications

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

T9MPV SmartComfort VS90 Product Specifications

INSTALLATION INSTRUCTIONS TXV Coils EBU, EBA

INSTALLATION INSTRUCTIONS TXV Coils EBD, EBA

Installation Instructions

TSTAT0101SC Recommended (order separately)

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

AVPTC. Air Handlers 1½ to 5 Tons

INSTALLATION INSTRUCTIONS TXV Coils EDM, EDD, EDA

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

SERVICING S-15 CHECKING CAPACITOR

AVPTC Multi-Position, Internal Txv

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

PF1MNB. Sizes 018m071

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHP SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

INSTALLATION INSTRUCTIONS

REPLACEMENT PARTS MANUAL

TSTAT0201CW Recommended (sold separately)

INSTALLATION INSTRUCTIONS

Wt. Lbs Model Number (BTUH) Hz

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

Installation Instructions

Residential Condensed Catalog

INSTALLATION INSTRUCTIONS

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

AVPTC Multi-Position, Internal Txv

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHX SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018

FC9V SERIES 2-STAGE CONDENSING VARIABLE SPEED UPFLOW NATURAL GAS FURNACES (STYLE C)

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

GM9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen (Style D) and 2nd Gen, STYLE B)

INSTALLATION INSTRUCTIONS

POSITION FEM10-M2301CM-A FEM15-M2301CM-A FEM18-M2301CM-A FEM20-M2301CM-A FEM23-M2301CM-A FEM20-M2301DM-A FEM23-M2301DM-A FEM27-M2301DM-A

installation and start-up instructions THERMIDISTAT CONTROL

Field Application of Advanced Residential Air Conditioning Systems

AVPTC. Air Handler 1½ to 5 Tons

REPLACEMENT PARTS MANUAL

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

ECM OPERATION MANUAL

REPLACEMENT PARTS MANUAL

Installation Instructions

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

FC9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen, Style D and 2nd Gen, Style B)

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

INSTALLATION MANUAL SINGLE PIECE VARIABLE SPEED AIR HANDLERS MODELS: AV*(C) SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

AVPTC Multi-Position, Internal Txv

Installation Instruction

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

Installation, Operation and Service Manual

TECHNICAL SPECIFICATIONS B6VMMX

SERVICE AND TECHNICAL SUPPORT MANUAL

Installation Instructions Part No , Part No Part No

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor

15CHPX. DAVE LENNOX SIGNATURE COLLECTION Residential - R-410A - Variable Speed Blower

Installation Guide.

RESIDENTIAL COOLING, HEATING, AND SMALL PACKAGE PRODUCTS CONDENSED CATALOG

REPLACEMENT PARTS MANUAL

CABINET PARTS For Model: KBLC36FTS04 (Stainless Steel)

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

REPLACEMENT PARTS MANUAL

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

FEM10-M2401AM-A FEM15-M2401AM-A FEM18-M2401AM-A FEM20-M2401AM-A FEM23-M2401AM-A FEM20-M2401BM-A FEM23-M2401BM-A FEM27-M2401BM-A

INSTALLATION AND MAINTENANCE INSTRUCTIONS EF Electric Furnace

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

SERVICE AND TECHNICAL SUPPORT MANUAL

Cooling Capacity CFM in. w.c. (125 Pa)

INSTALLATION INSTRUCTIONS Fan Coils FVM2X, FVM4X

Transcription:

Fan Coils FVM4X B Series DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only used on product labels to signify an immediate hazard. The signal words WARNING, CAUTION, and NOTE will be used on product labels and throughout this manual and other manuals that may apply to the product. DANGER Immediate hazards which will result in severe personal injury or death. WARNING Hazards or unsafe practices which could result in severe personal injury or death. CAUTION Hazards or unsafe practices which may result in minor personal injury or product or property damage. NOTE Used to highlight suggestions which will result in enhanced installation, reliability, or operation. Safety Labeling and Signal Words Signal Words in Manuals The signal word WARNING is used throughout this manual in the following manner: WARNING! WARNING The signal word CAUTION is used throughout this manual in the following manner:! CAUTION Signal Words on Product Labeling Signal words are used in combination with colors and/or pictures on product labels. TABLE OF CONTENTS Wiring Diagram... 2 Model Number Identification... 3 Airflow Charts... 4 7 Parts List... 8 10 Exploded Views... 11 14! WARNING ELECTRICAL SHOCK HAZARD Failure to turn off electric power could result in personal injury or death. Before installing or servicing system, turn off main power to the system. There may be more than one disconnect switch, including accessory heater(s). 496 04 5001 00 Sept. 2012

Wiring Diagram 2 496 04 5001 00

F = Fan Coil FAN COIL MODEL NUMBER IDENTIFICATION GUIDE F V M 2 X 2400 B 1 V = Variable speed ECM motor MOTOR TYPE M = Multiposition INSTALLATION TYPE 2 = R 22 4 = Environmentally Sound R 410A REFRIGERANT X = TXV METERING DEVICE 2400 = 24,000 BTUH = 2 tons 3600 = 36,000 BTUH = 3 tons 4800 = 48,000 BTUH = 4 tons 6000 = 60,000 BTUH = 5 tons NOMINAL CAPACITY Sales Code Engineering Revision ACCESSORIES PART NUMBER IDENTIFICATION GUIDE EB AC 01 NCB A EB = Evaporator Blower AC = Accessory 01 = Product Identifier Number NCB = Non Combustible Base Kit DFK = Down Flow Kit PLG = Power Plug (no heat kit) SPK = Single Point Wiring Kit FKS = Filter Kit Small FKM = Filter Kit Medium FKL = Filter Kit Large FKX = Filter Kit Extra Large CTK = Condensate Trap Kit (PVC pipe) Sales Code 496 04 5001 00 3

Fan Coil Size 2400 3600 4800 6000 FAN COIL AIRFLOW DELIVERY (CFM) IN COOLING MODE (A/C OR HP) Outdoor Single Stage Two Stage Cooling Unit Cooling High Low Fan Only Size Nominal Dehum Nominal Dehum Nominal Dehum Low Med Hi 18 525 420 Two Stage outdoor unit not offered 350 420 525 24 700 560 700 560 560 450 350 560 700 30 875 700 Two Stage outdoor unit not offered 440 700 875 36 1050 840 1050 840 840 670 525 840 1050 24 700 560 700 560 560 450 415 560 700 30 875 700 Two Stage outdoor unit not offered 440 700 875 36 1050 840 1050 840 840 670 525 840 1050 42 1225 980 Two Stage outdoor unit not offered 615 980 1225 30 875 700 Two Stage outdoor unit not offered 440 700 875 36 1050 840 1050 840 840 670 525 840 1050 42 1225 980 Two Stage outdoor unit not offered 615 980 1225 48 1400 1120 1400 1120 1120 900 700 1120 1400 36 1050 840 1050 840 840 670 540 840 1050 42 1225 980 Two Stage outdoor unit not offered 615 980 1225 48 1400 1120 1400 1120 1120 900 700 1120 1400 60 1750 1400 1750 1400 1400 1120 875 1400 1750 NOTES: 1. The above airflows result with the AC/HP CFM ADJUST select jumper set on NOM. 2. Airflow can be adjusted +15% or 10% by selecting Hi or Lo respectively for all modes except fan only. 3. Dry coil at 230 volts and with 10kW heater and filter installed. 4. Airflows shown are valid for systems with total static pressure between 0.1 and 0.7 inches water column. Fan Coil Size 2400 3600 4800 6000 Outdoor Unit Size Fan Coil Airflow Delivery (CFM) in Heat Pump Heating Mode Only Single Stage HP Two Stage HP Heating Heating High Low Fan Only Comfort Eff Comfort Eff Comfort Eff Low Med Hi 18 475 525 Two Stage outdoor unit not offered 350 380 475 24 630 700 630 700 505 560 350 505 630 30 785 875 Two Stage outdoor unit not offered 440 630 785 36 945 1050 945 1050 755 840 525 755 945 24 630 700 630 700 505 560 415 505 630 30 785 875 Two Stage outdoor unit not offered 440 630 785 36 945 1050 945 1050 755 840 525 755 945 42 1100 1225 Two Stage outdoor unit not offered 615 880 1100 30 785 875 Two Stage outdoor unit not offered 440 630 785 36 945 1050 945 1050 755 840 525 755 945 42 1100 1225 Two Stage outdoor unit not offered 615 880 1100 48 1260 1400 1260 1400 1010 1120 700 1010 1260 36 945 1050 945 1050 755 840 540 755 945 42 1100 1225 Two Stage outdoor unit not offered 615 880 1100 48 1260 1400 1260 1400 1010 1120 700 1010 1260 60 1575 1750 1575 1750 1260 1400 875 1260 1575 NOTES: 1. The above airflows result with the AC/HP CFM ADJUST select jumper set on NOM. 2. Airflow can be adjusted +15% or 10% by selecting Hi or Lo respectively for all modes except fan only. 3. Dry coil at 230 volts and with 10kW heater and filter installed. 4. Airflows shown are valid for systems with total static pressure between 0.1 and 0.7 inches water column. 4 496 04 5001 00

FVM Model Size Outdoor Unit Capacity (BTUH) AIRFLOW DELIVERY (CFM) Electric Heater kw Range 0 5 0 10 0 15 0 20 LO NOM HI LO NOM HI LO NOM HI LO NOM HI 18 625 625 625 675 675 675 * * * * * * 2400 24 650 725 835 * 725 835 875 875 875 * * * 30 815 905 1040 * 905 1040 900 900 1040 1100 1100 1100 36 980 1085 1250 980 1085 1250 980 1085 1250 1100 1100 1250 24 675 725 835 875 875 * * * * * * * 3600 30 815 905 1040 875 905 1040 1100 1100 1100 * * * 36 980 1085 1250 980 1085 1250 1100 1100 1250 1225 1225 1250 42 1140 1270 1460 1140 1270 1460 1140 1270 1460 1225 1270 1460 0 10 0 15 0 20 0 30 30 975 975 1040 1100 1100 1100 * * * * * * 4800 36 980 1085 1250 1100 1100 1250 1250 1250 1250 * * * 42 1140 1270 1460 1140 1270 1460 1250 1270 1460 * * * 48 1305 1450 1665 1305 1450 1665 1305 1450 1665 1500 1500 1665 36 1100 1100 1250 1350 1350 1350 * * * * * * 6000 42 1140 1270 1460 1350 1350 1460 1525 1525 1525 * * * 48 1305 1450 1665 1350 1450 1665 1525 1525 1665 1750 1750 1750 60 1630 1810 2085 1630 1810 2085 1630 1810 2085 1750 1810 2085 * Airflow not recommended for heater/system size NOTE: LO, NOM, and HI refer to AC/HP CFM ADJUST selection on the Fan Control Board. MINIMUM CFM FOR ELECTRIC HEATER APPLICATION FVM Model Size 2400 3600 4800 6000 FVM Model Size Outdoor Unit Size Heater Size kw 5 8, 9, 10 15 18, 20 24, 30 18 625 625 24 650 725 875 30 800 875 875 1040 36 970 970 970 1040 24 675 875 30 800 875 1100 1150 36 975 975 1100 1225 42 1125 1125 1125 1225 30 800 875 875 1150 36 975 975 1100 1225 42 1125 1125 1125 1225 48 1305 1305 1305 1305 1400 36 1100 1100 1350 1350 42 1125 1125 1350 1350 48 1300 1300 1350 1465 1750 60 1625 1625 1625 1750 1750 A/C Minimum CFM when using Electric Heat (CFM) Heater Size kw 5 8, 9, 10 15 18, 20 24, 30 625 625 725 875 2400 3600 675 700 850 1050 4800 Heater Only 675 700 850 1050 1400 6000 1050 1050 1050 1050 1750 NOTES: 1. Heater Only Air conditioner with electric heater application. 2. These airflows are minimum acceptable airflows as UL listed. Actual airflow delivered will be per airflow delivery chart for Electric Heating Modes. 496 04 5001 00 5

AIRFLOW PERFORMANCE CFM RANGE Fan Coil Size Use with Outdoor Unit Size CFM Range 2400 18, 24, 30, 36 350 1200 3600 24, 30, 36, 42 415 1400 4800 30, 36, 42, 48 425 1600 6000 36, 42, 48, 60 540 2000 SEQUENCE OF OPERATION FVM fan coils will supply airflow in a range which is more than twice the range of a standard fan coil. Each fan coil size is designed to provide nominal cooling capacities at 50 F evaporator temperature and the required airflow in order to match with any of four (4) different air conditioner or heat pump outdoor unit sizes. Refer to Airflow Performance (above) for the CFM range for the different FVM fan coils. The blower motor is a true variable speed motor designed to deliver constant CFM. Constant CFM is valid for systems with total external static pressure between 0.1 and 0.7 inches water column. A. CONTINUOUS FAN Thermostat close circuit R to G. Blower runs at continuous fan airflow. B. COOLING MODE SINGLE STAGE If indoor temperature is above temperature set point and humidity is below humidity set point, thermostat closes circuits R to G, R to Y/Y2 and R to O. NOTE: For single stage systems, do not use the Y1 terminal. Fan coil delivers single stage cooling airflow. C. COOLING MODE TWO STAGE First stage (low) cooling: Thermostat closes circuits to R to G, R to O, and R to Y1. Fan coil delivers low stage cooling airflow. Second stage (high) cooling: Thermostat closes circuits to R to G, R to O, R to Y1, and R to Y/Y2. Fan coil delivers high stage cooling airflow. D. COOLING MODE DEHUMIDIFICATION NOTE: FVM4X**B* Dehumidification functionality has changed from previous fan coil series Enhanced Dehu midification requires removing J1 jumper to activate the dehumidification mode, and install humidistat con trol between terminals R & Dh terminals (see page 6 Humidistat Wiring for De Humidify Mode). If indoor temperature is above temperature set point and humidity is above humidity set point, thermostat closes circuits R to G, R to Y/Y2 and R to O and humidistat opens R to DH. E. ELECTRIC HEAT HEATING MODE Thermostat closes circuit R to W/W1, or W2 Fan coil delivers the selected electric heat airflow. F. HEAT PUMP HEATING MODE SINGLE STAGE Thermostat closes circuits R to G and R to Y/Y2. NOTE: For single stage systems, do not use the Y1 terminal. Fan coil delivers single stage heat pump heating airflow. G. HEAT PUMP HEATING MODE TWO STAGE First stage (low) heating: Thermostat closes circuits R to G and R to Y1. Fan coil delivers low stage heating airflow. Second stage (high) heating: Thermostat closes R to G, R to Y1 and R to Y/Y2. Fan coil delivers high stage heating airflow. H. HEAT PUMP HEATING WITH AUXILIARY ELEC- TRIC HEAT Thermostat closes circuits R to G, R to Y/Y2 and/or R to Y1 with R to W/W1 or W2 (and R to O in the case of defrost). If the thermostat calls for electric heat when the heat pump is operating in heating or defrost, the motor will modify the airflow if necessary. The motor will provide an airflow which is safe for the operation of the electric heat. That airflow is the greater of the heat pump heating airflow and the electric heat only airflow.! CAUTION ELECTRICAL SHOCK or UNIT DAMAGE HAZARD Failure to carefully read and follow this CAUTION may result in equipment malfunction, property damage, personal injury and/or death. Disconnect power to unit before removing or replacing connectors or servicing motor. Wait at least five (5) minutes after disconnecting power before opening motor. The fan coil delivers airflow which is approximately 80% of the nominal cooling airflow to increase the latent capacity of the system. 6 496 04 5001 00

FAN CONTROL BOARD J2 JUMPER PULL FOR HEAT STAGING SEC1 SEC2 J1 PULL WHEN ATTACHING DEHUMIDIFICATION CONTROL LOW VOLTAGE SCREW TERMINALS DH DEHUMIDIFICATION INPUT AUX HEAT KW/CFM R 24 VAC HOT J2 W 1 AUXILARY HEAT STAGE 1 VIO AC/HP SIZE W2 AUXILIARY HEAT STAGE 2 BLU Y1 LOW STAGE COMPRESSOR ORN SYSTEM TYPE AC HP COMFORT HP EFF Y/Y2 SINGLE OR HI STAGE COMPRESSOR AC/HP CFM ADJUST NOM LO HI G FAN BLK ON/OFF DELAY O REVERSING VALVE 0 90 30 90 0 0 ENH C COMMON WHT LO CONTINUOUS FAN MED HI YEL AUX1 HUM1 YEL CEBD430226 01B CESS430226 01B AUX2 HUM2 G Y/Y2 W 2 24V DH 24VAC PIN 12 HEATER/MOTOR GRY 16 15 14 13 12 11 10 9 12 PIN CONNECTOR (PL 1) PIN 1 8 7 6 5 4 C 2 1 Y 1 16 PIN PLUG C W 1 C Humidistat Wiring for De Humidify Mode BOARD TERMINAL BLOCK J1 DH HUMIDISTAT REMOVE JUMPER R TROUBLESHOOTING ECM MOTOR AND CONTROLS SEE INSTALLATION INSTRUCTIONS FOR TROUBLESHOOTING INFORMATION. 496 04 5001 00 7

FCM4X PARTS LIST KEY NO. DESCRIPTION PART NO. FVM4X2400BT1 FVM4X3600BT1 FVM4X4800BT1 FVM4X6000BT1 01 BLOWER ASY 1183569 1 - - - 01 BLOWER ASY 1183570-1 - - 01 BLOWER ASY 1183571 - - 1-01 BLOWER ASY 1183572 - - - 1 02 TRANS 208/230>24 40VA 1170676 1 1 1 1 03 BOARD CIRCUIT CONTROL 1185358 1 1 1 1 04 HARNESS ASSY BLOWER 1171676 1 1 1 1 05 FILTER HH 21.5X16.375X1 1171652 1 - - - 05 FILTER HH 21.5X19.875X1 1171653-1 1-05 FILTER HH 21.5X23.3125X1 1171654 - - - 1 06 VALVE EXPANSION 1172348 1 - - - 06 VALVE EXPANSION 1172349-1 - - 06 VALVE EXPANSION 1172350 - - 1 1 07 COIL AND HDR ASY 1183574 1 - - - 07 COIL AND HDR ASY 1179023-1 - - 07 COIL AND HDR ASY 1179025 - - 1-07 COIL AND HDR ASY 1179026 - - - 1 08 STRAINER 1171740 1 1 1 1 09 PAN DRAIN 1179727 1 - - - 09 PAN DRAIN 1179674 - - 1-09 PAN DRAIN 1179728 - - - 1 10 CNDS PAN ASY 1179675 1 - - - 10 CNDS PAN ASY 1179731-1 - - 10 CNDS PAN ASY 1179676 - - 1-10 CNDS PAN ASY 1179677 - - - 1 11 WHEEL DD9X7X1/2 CW CV 1171744 1 - - - 11 WHEEL DD10X9X1/2 CW CV 1171741-1 1 1 12 MOTOR ½ HP 1185246 1 - - - 12 MOTOR ½ HP 1185247-1 - - 12 MOTOR ½ HP 1185248 - - 1-12 MOTOR ¾ HP 1185249 - - - 1 12A MODULE CONTROL 1176245 1 - - - 12A MODULE CONTROL 1176246-1 - - 12A MODULE CONTROL 1176247 - - 1-12A MODULE CONTROL 1176248 - - - 1 12B MTR BLR 1/115 1/2 1240 GE VARI 1172828 1 1 1-12B MTR BLR 1/115.75/1 1240 GEVAR 1172829 - - - 1 13 HARNESS ASSY UNIT 1174913 1 1 1 1 14 PANEL CUTOFF BLWR 1171571 1 - - - 14 PANEL CUTOFF BLWR 1171568-1 1 1 15 LUG GROUND 1170677 1 1 1 1 8 496 04 5001 00

FCM4X PARTS LIST (continued) KEY NO. DESCRIPTION PART NO. FVM4X2400BT1 FVM4X3600BT1 FVM4X4800BT1 FVM4X6000BT1 16 DISTRIBUTOR ASY 1171924 1 - - - 16 DISTRIBUTOR ASY 1172888-1 - - 16 DISTRIBUTOR ASY 1171606 - - 1-16 DISTRIBUTOR ASY 1171605 - - - 1 A PANEL TOP 1172364 1 - - - A PANEL TOP 1172335-1 1 - A PANEL TOP 1172336 - - - 1 AA PLATE HEATER 1171584 1 - - - AA PLATE HEATER 1171581-1 1 - AA PLATE HEATER 1171582 - - - 1 B DOOR LOWER 1172369 1 - - - B DOOR LOWER 1172340-1 - - B DOOR ASSY LOWER 1173795 - - 1 - B DOOR LOWER 1172342 - - - 1 BB DECK BLOWER 1171586 1 - - - BB DECK BLOWER 1171588-1 1 - BB DECK BLOWER 1171589 - - - 1 C DOOR UPPER 1172380 1 - - - C DOOR UPPER 1172346-1 - - C DOOR ASSY UPPER 1173796 - - 1 - C DOOR UPPER 1172347 - - - 1 CC BRACKET COIL 1171650-1 - - D DOOR FITTING 1172344 1-1 1 D DOOR FITTING 1172339-1 - - E DOOR FILTER 1171934 1 - - - E DOOR FILTER 1171935-1 1 - E DOOR FILTER 1171936 - - - 1 EE EXTENSION COIL 1171580-1 - - F BRACKET PCB 1171922 1 1 1 1 FF SUPPORT COIL 1171667-1 - - G BAFFLE DIFFUSER 1171569 2 2 2 2 GG BAFFLE COIL 1171644-1 - - H SPRING FILTER 1172554 1 1 1 1 HH SUPPORT COND PAN 1171664-1 - - J TUBE DRAIN 1172337 1-1 1 JJ CHANNEL COND 1171645-1 - - K GROMMET SUCTION 1171622 1 1 1 - K GROMMET SUCTION 1173772 - - - 1 L PLUG BUTTON 1173764 1-1 1 LL FITTING DRAIN 1171636 1-1 1 M SUPPORT BRACKET 1172636 - - 1 1 496 04 5001 00 9

FCM4X PARTS LIST (continued) KEY NO. DESCRIPTION PART NO. FVM4X2400BT1 FVM4X3600BT1 FVM4X4800BT1 FVM4X6000BT1 MM FITTING DRAIN 1171635 1-1 1 PP CAP END 1174949 1-1 1 N BRACKET COIL 1171574 1-2 2 RR CAP END 1174950 1-1 1 P BRACKET COIL 1171575 1-2 2 Q SHIELD COND PAN 1172328 1 1 2 2 R AIR SEAL ASY 1171640 1 - - - R AIR SEAL ASY 1171641 - - 1 1 S TROUGH CNDS 1171920 1 - - - S TROUGH CNDS 1171638 - - 1 1 T TROUGH CNDS 1171637 1-1 1 U BAFFLE DRIP 1171921 1 - - - U BAFFLE DRIP 1171647 - - 2 - U BAFFLE DRIP 1171648 - - - 2 V RING DRIP 1171649 1-1 - V RING DRIP 1172329 - - - 1 W BAND MOTOR MOUNT 1171733 1 1 1 1 X KIT HSG/WHEEL 9 X 7 1174921 1 - - - X KIT HSG/WHEEL 10 X 9 1174922-1 1 1 Y ARM & GROM ASSY 1173746 3 3 3 3 Z SCREW 1170636 3 3 3 3 Parts Not Shown )( GROMMET 1171737 1 1 1 1 )( GROMMET LIQUID 1171620 1 1 1 1 )( PAINT DARK GREY 16OZ AEROSOL S 1171357 1 1 1 1 )( FUSE 1171735 1 1 1 1 10 496 04 5001 00

NOTE: This illustration is for reference only. Your unit may differ in appearance or may not include all components shown. A C B H D 15 K AA G BB 5 1 E 496 04 5001 00 11

NOTE: This illustration is for reference only. Your unit may differ in appearance or may not include all components shown. 7 R LL RR T MM PP S M 6 U 7 L Q V 10 N P 9 8 J 16 496 04 5001 00 12

NOTE: This illustration is for reference only. Your unit may differ in appearance or may not include all components shown. CC EE GG 7 JJ DD FF HH 10 16 8 6 496 04 5001 00 13

NOTE: This illustration is for reference only. Your unit may differ in appearance or may not include all components shown. 2 F 15 3 W 4 14 Y 11 13 Z X 12 496 04 5001 00 14