Level Control Systems Serie NT 2000 Manual and documentation

Similar documents
Process Alarm Module RTA 421

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

INSTALLATION AND OPERATING MANUAL

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

Power Supply Display Module PSDM. Installation and Operation Manual

On the job around the clock 24/7: Fire detection systems

Assembly Instruction GfS Door Terminal

Control and Annunciator Panels. Compact systems of signalling and control

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

DICTATOR Hold-Open Systems for Hazardous Areas

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Technical Manual. Level Alarm Unit CARLA & WIDS

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

FIRE DETECTOR TYPE ED816 ZONE 5 ZONE 4 ZONE 6 ZONE 7 FIRE FIRE FIRE FIRE FAULT FAULT FAULT FAULT DISABLED DISABLED DISABLED DISABLED OFF OFF OFF OFF

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

FEC400 Series. Installation Manual

Snifter ATEX22 VERSION. User Manual. Distributor

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

Operation and Installation Instruction Fire Alarm Computer 8000C / M

Operations Manual. Motion Detector Module Model ZS10

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

HEATFAST HF9101-V1 AMBIENT SENSING TRACE HEATING THERMOSTAT

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Conventional Fire Alarm System 2014 V1.2

new new Industrial plugs and sockets

AUDIBLE SIGNALIZATION

Door Release Power Supply

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

APPLICATIONS. With our high quality light curtains we are a trusted, long-term partner of the leading elevator manufacturers.

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

ABLOY FIRE DOOR CLOSING SYSTEMS

Installation, Operating and Maintenance Manual

PROTECT SRB 200EXi-1A

Sounder AX03, AX05. Loud signalling device with 32 different signals. Application. Design. Signalling devices with good directivity

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

D-GF 150. Burner Control for Gas and Oil Burners Flame Sensor D-GF 150 D-LE 103

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Output module (230 V)

AIS750 Series Alarm Annunciator

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

DiMM Unit. LST Digital Interface Monitor Module (LST-DiMM) MAN3109

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

DIGITAL ALARM UNIT Model ALU-AP

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

1. Instruction. 1.5 Warranty Comar Condensatori S.p.A. guarantees its own products for twelve months from purchase

Instruction Manual. Electronic gas and smoke detector GRM

10yr O2NE & Safe-Ox. User Manual

8.0 Table of Contents. Monitoring system WIREM

APPLICATION DATA SHEET

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

DIGITAL LIGHT CONTROLLER

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

A6 Safety Monitoring Device

ECO ETS Electromotive drive

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Installation, Operation and Maintenance Manual

EXTINGUISHING CONTROL PANEL PX2 SERIES

MODEL 5100 VOTING LOGIC MODULE

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

AE-CU Adaptive Escape Routing for Emergency Lighting. From static to adaptive escape routing

SINGLE CHANNEL SYSTEM TWO CHANNEL SYSTEM

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Multi line separator module

Gira nurse call system Installation, start-up, operation. Gira emergency set

Flostop TS D7E and A8E. Operation Manual

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

Alfa Laval Level Switch

IR FLAME DETECTOR RIV-601/F

Chromatographic Air circulated Refrigerator, two-door TC 603

EXTINGUISHING AGENT RELEASE MODULE

Laboratory Refrigerator/Deep Freezer TC 802

SIL2-Interface/ -Signal Conditioners Series DuoTec

EBDSPIR-PRM-LV Product Guide

ZSC100 Gas Detection and Alarm System Controller

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

PRODUCT INFORMATION. Solar DHW storage tank SKL. Technical description. High performance solar tank, bivalent

TER Active Room Temperature Sensor (Controller),

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor

Dryer Systems Heat Regenerating Adsorption Dryers

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

Chromatographic Air circulated Refrigerator, two-door TC 603

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

Gebrauchsanweisung User manual 使用手冊マニュアル

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Transcription:

Nivotec 1 Table of contents Serie NT 000 Page Operation / overview s / functions G Technical data / Components G G Components G Installation / Service G Technische Änderungen vorbehalten. Selbstverständlich sind Gerätevarianten außerhalb der Angaben dieser Geräteinformation möglich. Für Druckfehler kann keine Haftung übernommen werden. Bitte sprechen Sie mit unseren technischen Beratern. ING. ROLF HEUN Meß- Prüf- Regeltechnik GmbH Hufeisen 1 1 Seevetal/Hittfeld Tel: 0--0 Fax: 0-- info@heun-messtechnik.com www.heun-messtechnik.com NT 000 gi page G 1

1 Nivotec Operation / overview Overview The NT 000 is a control cabinet system for fi ll level display and control which evaluates the normal -0 ma and digital signals of level sensors both acoustically and optically. The fi ll level display is via the Nivotec NT LED display in percentage, height, volume or weight. The -0 ma and digital inputs can be connected from any amount of sensors. It must only be decided whether the inputs are from pure electronic measurement technology or from electromechanical Lot measurement systems. A start button, alarm and end position signal are provided on the front of the control panel user panel for Lot systems; point level sensors such as full and empty are displayed via LEDs on the front of the panel. The NT 000 can also be set up with a shut off valve control, which prevents the fi lling of the wrong silo and overfi lling. The alarm signal "full" is via an acoustic buzzer or via a fl ashing lamp. When the lorry module is included, then the "full" alarm is also integrated into this module. Serie NT 000 electro mechanical Lots ystem shut off valve control NT 000 Schaltschrank Alarm signal "full" shut off valve control NT 000 lorry module The lorry module is mounted on the silo site. We suggest to protect it against snow, rain or sun with a roof. It contains a buzzer or fl ashing light which can be cancelled via a button. Likewise there is an LED for full and empty detection for each silo. Enabling of the shut off valve is also on this module. These ensure that no silo is overfi lled or that the wrong silo is fi lled. For the clamping between the signals / supply voltage, a terminal box is mounted on the silo frame. The Nivotec NT 000 is delivered as a complete system with project specifi c electrical plans. Equipment overview System Control cabinet Input signal Displays Alarm signal "full" on control cabinet Lorry module Shut off valve Control cabinet with module for display and control of the fi ll level and point measurement of silos Project specifi c, complete wired system with electric plans, including the power supply for the measurement technology - -0 ma - digital (potential free or + VDC) - Fill level display LED display Nivotec NT in percentage, height, volume or weight - point level "full" and "empty" via LEDs Full signal via buzzer or blinking lamp, LED for full and empty level; cancelled via button on control cabinet Fill level monitoring during the fi lling; full signal via buzzer or fl ashing lamp; cancelled via button. An LED shows a silo has been cleared for by option shut-off valve. A silo can be cleared for fi lling by a key switch; automatic shut off valve operation when full detection occurs. For connection between the measurement signal and supply voltage on the silo and the silo frame ING. ROLF HEUN Meß- Prüf- Regeltechnik GmbH Hufeisen 1 1 Seevetal/Hittfeld Tel: 0--0 Fax: 0-- info@heun-messtechnik.com www.heun-messtechnik.com page G gi NT 000

Nivotec 1 s / functions Basic equipment Measurement technology Alarm signal "full" Lorry module Function Description Serie NT 000 Control cabinet for mounting on the wall with right hinged door. Per measurement point - one digital display NT Per measurement point, - yellow LED for full signal - red LED for empty signal Main switch is in the control cabinet door Cable glands on the underside of the control cabinet All clamps for the connection of measurement signals, sensor and control cabinet power supplies, earthing etc are supplied in the control cabinet. Project specifi c electrical plans The electronic measurement technology such as Nivowave or Radar, etc can be connected. No extra user modules are necessary in the control cabinet door. By use electromechanical Lot systems such as the UWT SLS 000, a green illuminated start button and a red LED for malfunction signals is included on the control cabinet door. The alarm signal "full" occurs when the full sensor sends a signal during fi lling and is via an acoustic buzzer or optical fl ashing lamp. The alarm signal can be cancelled via a button on the control cabinet door. Either the option buzzer or fl ashing lamp may be chosen. The lorry module contains the alarm signal "full" and shows via LEDs which silos are full and empty. The alarm signals can be cancelled via a button on the lorry module. Additional information The type and dimensions are dependant on the size of the project. The NT as a current loop meter (-0mA) and can be programmed to display the fi ll level in percentage, height, volume or weight. The programming is described in the Nivotec accessories documentation. LEDs illuminate when full or empty signal is received. The number is dependant on the size of the project. The control cabinet runs on 0 VAC. All further modules such as the power supplies, fuses, relays, logic modules, etc are in the cabinet on DIN rails and are internally wired. The electrical plans are prepared to the actual standards and contain all circuit diagrams, cable lists, clamp plans, parts lists and documentation of all components that are contained in the project. When the Lot is started, the green start button illuminates (end stop signal from Lot). Once the measurement is completed, the light is extinguished. Therefore it can be visually seen whether a measurement is in operation or not. The buzzer or fl ashing lamp can be mounted where required. When the shut off valve option is selected, the module shows which silo has been released for fi lling via an LED. The lorry module is typically mounted near the fi lling station. Shut off valve control The terminal box is for the intermediate connections of all signals and power supplies from the silo plant to further evaluations. It is a metal housing with a screw on lid and cable glands on the underside. The valve in the fi lling pipes can be opened before fi lling via a key switch on the control cabinet. Once the silo is detected as full, the valve is automatically closed and therefore prevents overfi lling. The valve can only be reopened via the key switch (eg to blow out the fi lling pipe). The installation is on the silo frame. The cables are laid out according to the electrical plans. The size of the terminal box is dependant on the number and type of the sensors as well as the size of the project. When the lorry module is selected, the silos that have been released for fi lling are shown via an illuminated LED. ING. ROLF HEUN Meß- Prüf- Regeltechnik GmbH Hufeisen 1 1 Seevetal/Hittfeld Tel: 0--0 Fax: 0-- info@heun-messtechnik.com www.heun-messtechnik.com NT 000 gi page G

1 Nivotec Technical data / components Technical data Serie NT 000 Housing Dimensions The dimensions of the control cabinet module, lorry module and terminal box are dependant on the number of measurement points and the option selections. Generally the cabinets are for wall mounting. Should it be required, it is possible to supply a control cabinet mounted on a stand. Material Steel, Colour RAL 0 Protection class Control cabinet IP Lorry module IP IP Supply voltage Input voltage 0 VAC Control voltage VDC Current consumption Dependant on the number of measurement points and the selection of options. Fuse The fusing is dependant on the project specifi c current loads. Display module LED display Nivotec NT (see documentation NT ) Lamps LED in housing red and yellow Operating conditions Temperature 0 to 0 C Components NT 000 control cabinet page G ING. ROLF HEUN Meß- Prüf- Regeltechnik GmbH Hufeisen 1 1 Seevetal/Hittfeld Tel: 0--0 Fax: 0-- info@heun-messtechnik.com www.heun-messtechnik.com gi NT 000

Nivotec 1 Components Serie NT 000 NT 000 Lorry module The component numbers correspond to the provided labelling on the control cabinet, lorry module and terminal box drawings. No Group Labelling Components 1 Housing without Rittal AE or Häwa, with right hinged swing door, RAL 0 (Screw on lid for terminal box) Silo No. Silo x PVC white, black writing LED display without Nivotec NT, -0 ma Start button electromechanical Lot system START Green colour, lights up for the end stop signal Display silo full FULL LED yellow Display silo empty EMPTY LED red Display malfunction electromechanical Lot system Malfunction LED red Main switch without Type Moeller, red/yellow Cancellation of buzzer or fl ashing light ALARM OFF Black colour Buzzer without Type Eichhoff / Friedland 0 VAC Flashing lamp without Type Werma / Moeller red colour Key switch Filling enabled Type Moeller 1 Display - fi lling enabled FILLING LED green ENABLED All displays LED lights, Type Moeller All buttons Type Moeller Name plates PVC white, black writing Clamps Type Wago Fuses Type ABB FI switches Type ABB Relays Type SHC / Schrack Logic modules Type Siemens ING. ROLF HEUN Meß- Prüf- Regeltechnik GmbH Hufeisen 1 1 Seevetal/Hittfeld Tel: 0--0 Fax: 0-- info@heun-messtechnik.com www.heun-messtechnik.com NT 000 gi page G

1 Nivotec Installation / Service Safety instructions: Serie NT 000 - The installation of the Nivotec NT 000 system can only be carried out by suitably qualifi ed persons. - The cabling and wiring must be carried out in accordance with the delivered electrical plans. - Other cable may only be used when approved in advance by UWT - The installation of the modules must take into account the housing protection classes. - The system NT 000 has no ATEX approval. If it is needed it must be discussed with UWT staff during the discussion of your project requirements. Service: The qualifi ed service staff at UWT can install and carry out the initial setup of the Nivotec systems as well as all level measurement technology in both a professional and qualifi ed manner. You will receive an acceptance test report as well as user documentation for the ongoing support of your system. Please contact a member of the UWT sales or service team to discuss your requirements. page G ING. ROLF HEUN Meß- Prüf- Regeltechnik GmbH Hufeisen 1 1 Seevetal/Hittfeld Tel: 0--0 Fax: 0-- info@heun-messtechnik.com www.heun-messtechnik.com gi NT 000