Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH9000 Series ±1.7 %RH Accuracy. Datasheet

Similar documents
Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH6100 Series ±4.0 %RH Accuracy. Datasheet

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6000 Series ±4.5 %RH Accuracy

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

humidity sensors Line Guide FEATURES Honeywell HumidIcon HIH6120/6121 Series

HIH-5030/5031 Series Low Voltage Humidity Sensors

HIH-4030/31 Series Humidity Sensors

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

HIH-4000 Series Humidity Sensors

HIH-4010/4020/4021 Series Humidity Sensors

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

Magnetoresistive Sensor ICs. Nanopower Series. Datasheet

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

HIH-4602-L Series Humidity Sensors


Micropower Omnipolar Digital Hall-Effect Sensor ICs

Application Note Sensors and Flexible Heaters in Ventilator Applications

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

FSS-SMT Series. Low Profile Force Sensor

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Application Note Sensors and Flexible Heaters in Anesthesia Machine Applications

Potential Applications

High Sensitivity Bipolar Latching Digital Hall-Effect Sensor ICs SS360NT/SS360ST/SS460S. Datasheet

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Installation Instructions for the

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

TruStability Board Mount Pressure Sensors

Sensors in Ventilators

FEATURES AND BENEFITS

Supply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F

Application Note Sensors and Flexible Heaters in Sleep Apnea Machines

HIH-4602 A & C Series.

Omnipolar Digital Hall-effect Sensor ICs: SS351AT, SS451A, SS551AT

Airflow Sensors Line Guide

Application Note Honeywell Zephyr Analog and Digital Airflow Sensors: HAF Series-High Accuracy, ±50 SCCM to ±750 SCCM

Force Sensors Line Guide

Quadrature Speed and Direction Sensors

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

Airflow Sensors Line Guide

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

SX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi

Sensor Evaluation Kit, SEK001

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Table 1. Absolute Maximum Ratings. Characteristic. Magnetic flux. ma maximum ±670 ±600 ±670 ± ± ±0.150 ± , , +0.

Magnetoresistive Sensor ICs 2SS52M Series Issue 2. Datasheet. Sensing and Productivity Solutions

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-LP

MICRO SWITCH NT Series

HOA6480 Series Barcode Sensor Infrared Products

HFX Fiber Optic Component 50 Mbps, 650 nm LED

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Installation Instructions for the

High Temperature Industrial VRS Magnetic Speed Sensors

Selecting Honeywell Board Mount Pressure Sensors

MICRO SWITCH NT Series

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

Installation Instructions for the 600 Series Optical Encoders

Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

AMR 4-Pin Quadrature Sensor Integrated Circuit

V-Basic Standard V15 Series

Selecting the right humidity sensor for your application

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

High Sensitivity Latching Digital Hall-effect Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-T3 SS460S-LP

High Sensitivity Latching Digital Hall-effect Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-LP

General Purpose Industrial VRS Magnetic Speed Sensors

WARNING MISUSE OF DOCUMENTATION

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

MSP100 Pressure Transducer

Linear Current Sensors

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy 20 SLPM or 200 SLPM

Issue B. Bipolar Hall-Effect Digital Position Sensor ICs: SS41, SS41-L, SS41-T2, SS41-T3, SS41-S, SS41-SP. Sensing and Internet of Things

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

Interactive Catalog Replaces Catalog Pages

MICRO SWITCH V15W Series Watertight Miniature Switches

MICRO SWITCH GLL Series

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

FR/SR Series. Full Sized, Sealed Rocker Switches SR SERIES FR SERIES DESCRIPTION FR SERIES SR SERIES FEATURES FR SERIES SR SERIES

Intrinsically Safe Transmitters, Option Code 2n

Transportation Attitude Reference System (TARS Series) Ruggedized Inertial Measurement Unit (IMU) Issue 2. Datasheet

Wireless Panel-Mount Monitor

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 4. Datasheet

MICRO SWITCH BAF/DTF Series

Issue 4. Bipolar Hall-Effect Digital Position Sensor ICs: SS40F, SS40AF. Sensing and Internet of Things. Datasheet

MSP100 Pressure Transducer

Board Mount Pressure Sensors Line Guide

Transcription:

Honeywell HumidIcon Digital Humidity/Temperature Sensors HIH9000 Series ±.7 %RH Accuracy Datasheet

Honeywell HumidIcon Digital Humidity/Temperature Sensors Honeywell HumidIcon Digital Humidity/Temperature Sensors, HIH9000 Series, are digital output-type relative humidity (RH) and temperature sensors combined in the same package. These sensors provide an accuracy level of ±.7 %RH. Industry-leading long-term stability Industry-leading reliability Lowest total cost solution True temperature-compensated digital or SPI output Energy efficiency Ultra-small package size and options Other accuracies available: ±2.0 %RH (HIH8000 Series), ±3.0 %RH (HIH7000 Series), ±4.0 %RH (HIH600 Series), and ±4.5 %RH (HIH6000 Series) What makes our sensors better? HIH93 One sensor does the work of two! ±.7 %RH Accuracy (humidity performance) ±0.6 C Accuracy (BFSL) (temperature performance) -40 C to 25 C [-40 F to 257 F] Operating Temp. Range ±.0 %RH Hysteresis HIH930 The series consists of packaging variations, offering customers the ability to choose housing style (SIP 4-Pin or SOIC-8 SMD), filter (hydrophobic filter or no filter), output ( or SPI), and packaging (tape and boxed, tape and reel, or samples on tape). HIH9000 Series Housing, Filter, Output, and Packaging Comparison HIH920 HIH92 Series* Output type Supply voltage Housing style Filter Accuracy Output Packaging HIH920-02-xxxx HIH92-02-xxxx SIP 4-pin SIP 4-pin without filter, non-condensing with filter, condensation resistant 00 to 249 units on tape and boxed, 250 units or more on tape and reel; or 5 sample pieces on tape HIH930-02-xxxx HIH930-000-xxxx digital 2.3 Vdc to 5.5 Vdc SOIC-8 SMD SOIC-8 SMD without filter, non-condensing without filter, non-condensing ±.7 %RH SPI 000 pieces on tape and reel; or 5 sample pieces on tape HIH93-02-xxxx HIH93-000-xxxx SOIC-8 SMD SOIC-8 SMD * See order guide on page for complete catalog listings. with filter, condensation resistant with filter, condensation resistant SPI 000 pieces on tape and reel; or 5 sample pieces on tape INDUSTRY-LEADING reliability ACCuracy packaging long-term stability 2 sensing.honeywell.com

Features and Benefits Industry-leading long-term stability* (.2 %RH over five years) Competitive humidity sensors require a 2 hour at 75 %RH rehydration process (which requires special equipment chambers) to correct reflow temperature offset. Honeywell s sensor also experiences an offset after reflow; however, it only requires a five-hour rehydration under ambient conditions (>50 %RH). Honeywell s industry-leading long-term stability: Minimizes system performance issues Helps support system uptime by eliminating the need to service or replace the sensor during its application life Eliminates the need to regularly recalibrate the sensor in the application, which can be inconvenient and costly ±.7 Industry-leading reliability (MTTF 9,32,507 hr)* Thermoset-polymer capacitive sensing element s multilayer construction provides resistance to most application hazards such as condensation, dust, dirt, oils, and common environmental chemicals, which help provide industry-leading reliability %RH ACCURACY Offers customers the lowest total cost solution. Lowest total cost solution* Honeywell s HumidIcon HIH9000 Series delivers the lowest total cost solution due to the sensor s industry-leading combined humidity/temperature sensor One sensor does the work of two! Combined humidity and temperature sensor Allows the RH measurement to be temperature compensated, and provides a second, standalone temperature sensor output; allows the user to purchase one sensor instead of two Energy efficient* Low supply voltage: Can operate down to 2.3 Vdc, which allows use in low energy and wireless-compatible applications to enhance energy savings and prolong system battery life Low power consumption: The sensor goes into sleep mode when not taking a measurement within the application, consuming only µa of power versus 750 µa in full operation in a battery operated system; sleep mode helps maximize battery life, reduces power supply size, and reduces the application s overall weight *Competitive Differentiator sensing.honeywell.com 3

Features and Benefits HIGH RESOLUTION High 4-bit humidity sensor resolution and 4-bit temperature sensor resolution within the application help the user s system detect the smallest relative humidity or temperature change Free up PCB space. Reduce costs. True, temperature-compensated digital or SPI output* Typically allows the customer to remove the components associated with signal conditioning from the PCB to free up space and reduce costs associated with those components (e.g., acquisition, inventory, assembly). True, temperaturecompensated digital or SPI output often eliminates problems that could occur from having multiple signal conditioning components across the PCB, as well as simplifies integration to the microprocessor, eliminating the need for customerimplemented, complex signal conditioning Choose options to best fit the application. HOUSING STYLE SOIC-8 SMD (Surface Mount Device) or SIP 4 Pin; ultra-small size allows for flexibility of use within the application, occupies less space on the PCB, and typically simplifies placement on crowded PCBs or in small devices; industry standard design simplifies design-in filter Available with hydrophobic filter and condensation-resistance, allowing for use in many condensing environments, or without hydrophobic filter, non-condensing Tape AND reel Allows for use in high volume, automated pick-and-place manufacturing, eliminating lead misalignment to the PCB and helping the customer to reduce manufacturing costs Wide operating temperature range -40 C to 25 C [-40 F to 257 F] allows for use in many applications Optional one or two %RH level alarm outputs Provides the ability to monitor whether the RH level has exceeded or fallen below predetermined and critical levels within the application Multi-function ASIC Delivers flexibility within the application by lowering or eliminating the risk and cost of OEM calibration RoHS and WEEE compliant, Halogen Free 4 sensing.honeywell.com *Competitive Differentiator

Potential Applications INDUSTRIAL HVAC/R May be used to provide precise RH and temperature measurement in air conditioning/air movement systems, enthalpy sensing, thermostats, humidifiers/ dehumidifiers, and humidistats to maintain occupant comfort and ideal storage humidity/temperature while achieving low energy consumption, supporting system accuracy and warranty requirements, maximizing system uptime, and improving overall system quality. AIR COMPRESSORS May be used to provide precise RH measurement in compressed air lines, allowing the system to remove any condensation; dry compressed air is critical for customer process control measurement. weather stations May be used to provide precise RH and temperature measurement in ground-based and airborne weather stations, allowing real time and highly accurate monitoring/ reporting of actual weather conditions. telecom cabinets May be used to provide precise RH and temperature measurement in the telecom cabinet HVAC system; maintaining proper temperature and humidity levels in the cabinet provides maximum system uptime and performance. INDUSTRIAL incubators/microenvironments May be used to provide optimal temperature and RH levels to support critical processes and experiments, enhancing process efficiency with desired climate conditions. MEDICAL RESPIRATORY THERAPY May be used to provide precise RH and temperature measurement in sleep apnea machines and ventilators, enhancing patient comfort, safety and treatment effectiveness with warm and humidified air. incubators/microenvironments May be used to provide optimal temperature and RH levels to support critical processes and experiments, enhancing process efficiency with desired climate conditions. sensing.honeywell.com 5

HIH9000 Series ±.7 %RH Accuracy Table. Environmental Specifications Characteristic Condition Min. Typ. Max. Unit Operating temperature range powered -40 [-40] 25 [257] C [ F] Operating humidity range powered 0 00 %RH Storage temperature range unpowered -40 [-40] 25 [257] C [ F] Storage humidity range 30 50 %RH Soldering temperature: manual automated 4 s reflow peak 30 s reflow peak 350 [662] 260 [500] ESD MIL-STD 883H, Method 305.7 ±4 kv Latch-up immunity ±00 ma Shock MIL-STD 202G, Method 23D, Test Condition C, half-sine, 6 ms ±3 perpendicular axis, 3 shock 00 g pulses per axis Vibration MIL-STD 202G, Method 204D, Test Condition D, 0 Hz to 2000 Hz 20 g Light sensitivity exposed to 50 lumens yellow light; exhibited no change in output Reliability (MTTF) 9,32,507 hr C [ F] Table 2. Humidity Performance Specifications Characteristic Condition Min. Typ. Max. Unit Supply voltage variation effect on humidity 2.3 Vdc to 5.5 Vdc 0..5 %RH/V Compensated humidity range 5 C to 50 C [4 F to 22 F] 0 90 %RH Compensated temp. range 5 [4] 50 [22] C [ F] Resolution 4 bit ADC resolution 0.04 %RH Accuracy 2 25 C [77 F] rising RH ±.7 %RH Maximal accuracy ±3.0 %RH Hysteresis ±.0 %RH Long term stability 50 %RH, 25 C [77 F], 5 years ±0.05 ±.2 %RH Response time t 63 % 8 s Impact of soldering IPC/EIA/JEDEC J-STD-020D, peak temp. of 260 C [500 F] ±2.5 %RH Notes: Conversion Formulas: 4 bit ADC output for humidity to %RH: 4 bit ADC output for temperature conversion to C: Humidity_4_bit_ADC_output Humidity (%RH) = x 00 Temperature (C ) = Temperature_4_bit_ADC_output x 65 40 2 4 2 2 4 2 2 Accuracy is specified at the typical supply voltage of 3.3 Vdc and at 25 C [77 F]. It is the maximum deviation from the ideal transfer function of relative humidity measured over the compensated humidity range of 0 %RH to 90 %RH. 6 sensing.honeywell.com

Honeywell HumidIcon Digital Humidity/Temperature Sensors Table 3. Temperature Performance Specifications Characteristic Condition Min. Typ. Max. Unit Supply voltage variation effect on temperature 2.3 Vdc to 5.5 Vdc 0..0 C/V Compensated temp. range 5 [4] 50 [22] C [ F] Resolution 4 bit ADC resolution 0.025 C Accuracy (BFSL) 5 C to 50 C [4 F to 22 F] ±0.6 C Long term stability 25 C for 5 years ±0.05 C/yr Response time t 63 % 30 s Impact of soldering IPC/EIA/JEDEC J-STD-020D, peak temp. of 260 C [500 F] ±0. C Note: Accuracy is specified over the compensated temperature range. Table 4. Current Consumption Characteristic V DD Abbr. Condition Typ. Max. Unit Sleep current 3.3 I SLEEP 0.6 µa Supply current: SPI 3.3 3.3 I DD I DD 4 bit fastest update, no sleep 4 bit fastest update, no sleep 0.65 0.75 ma ma Table 5. Input and Output Characteristics Characteristic Abbr. Condition Min. Typ. Max. Unit Supply voltage V DD 2.3 3.3 5.5 Vdc Low level output voltage V OL I OL = 2.8 ma min. 20 % V DD High level output voltage V OH I OH = -2.8 ma min. 80 % V DD Low level input voltage V IL 20 % V DD High level input voltage V IH 80 % V DD Pull-up resistor: SPI (for SS only) R P R SS 2.2 0 Table 6. Measurement Timing Characteristic Abbr. Condition Min. Typ. Max. Unit Start-up time (power-on to data ready) Update rate T STA 4 bit TH and 4 bit humidity resolution 50 60 ms application dependent: measurements are taken only when the application requests them sensing.honeywell.com 7

HIH9000 Series ±.7 %RH Accuracy Figure. Timing Diagram SDA t LOW t SUDAT t HDSTA t BUS SCL t HDSTA t HDDAT t HIGH t SUSTA t SUSTO Characteristic Abbr. Min. Typ. Max. Unit SCL clock frequency F SCL 00 400 khz Start condition hold time relative to SCL edge t HDSTA 0. µs Minimum SCL clock low width t LOW 0.6 µs Minimum SCL clock high width t HIGH 0.6 µs Start condition setup time relative to SCL edge t SUSTA 0. µs Data hold time on SDA relative to SCL edge t HDDAT 0 0.5 µs Data setup time on SDA relative to SCL edge t SUDAT 0. µs Stop condition setup time on SCL t SUSTO 0. µs Bus free time between stop and start condition t BUS µs Note: Combined low and high widths must equal or exceed minimum SCL period. Figure 2. SPI Timing Diagram t HDSS t HIGH t LOW SCLK MISO HiZ HiZ t CLKD t CLKD t SUSS SS t BUS Characteristic Abbr. Min. Typ. Max. Unit SCLK clock frequency f SCL 50 800 khz SS drop to first clock edge t HDSS 2.5 μs Minimum SCLK clock low width t LOW 0.6 μs Minimum SCLK clock high width t HIGH 0.6 μs Clock edge to data transition t CLKD 0 0.5 μs Rise of SS relative to last clock edge t SUSS 0. μs Bus free time between rise and fall of SS t BUS 2 µs Note: Combined low and high widths must equal or exceed minimum SCLK period. 8 sensing.honeywell.com

Honeywell HumidIcon Digital Humidity/Temperature Sensors Figure 3. SOIC-8 SMD Typical Application Circuits SPI VSUPPLY = 2.3 Vdc to 5.5 Vdc VSUPPLY = 2.3 Vdc to 5.5 Vdc Digital Humidity/Temp. Sensor 8 3 VDD SCL 2.2 2.2 Digital Humidity/Temp. Sensor 8 3 VDD SS 0 0.22 µf 0. µf 2 VCORE VSS 4 SDA 6 AL_L LED 2 V 0.22 µf 0. µf 2 VCORE VSS 4 SCLK 5 MISO GND 7 NC AL_H 5 GND GND 7 NC AL_L 6 LED Figure 4. SOIC-8 SMD Mounting Dimensions, PCB Landing Pattern and Pinout [For reference only: mm/[in].) Mounting Landing Pattern 4,90 [0.93] 8 7 6 5,905 [0.075] 0,5 [0.006] 8X 0,6 [0.024] 8X 2,03 [0.08] 3,90 [0.53] 6,0 [0.236] 4X 4,9 [0.93],27 [0.050] 2 3 4 0.4 [0.06] 2,055 [0.08] 0,203 [0.0080] 6X,27 [0.05] Pinout for Versions Pinout for SPI Versions Pin ASIC Pad Description Pin ASIC Pad Description V CORE connect via 0. µf to ground V CORE connect via 0. µf to ground 2 V SS supply ground 2 V SS supply ground 3 SCL clock 3 SS slave select (Input) 4 SDA data 4 SCLK serial clock 5 AL_H alarm output high 5 MISO master-in-slave-out 6 AL_L alarm output low 6 AL_L alarm output low 7 NC not connected externally 7 NC not connected externally 8 V DD supply voltage, connect via 0.22 µf to ground 8 V DD supply voltage, connect via 0.22 µf to ground Do not connect Pin(s) 5 and/or 6 if the built-in alarm feature is not desired. Do not connect Pin 6 if the built-in alarm feature is not desired. Tape and Reel,50 [0.059] 4,00 [0.57],75 [0.069] 0,29 [0.0] 3 [0.5] 2.00 [0.472] 5,50 [0.26] 02 [4.0] 8,00 [0.35] 2,58 [0.02] 330 [3,0] 7,4 [0.68] sensing.honeywell.com 9

HIH9000 Series ±.7 %RH Accuracy Figure 5. SIP 4 Pin Typical Application Circuit VSUPPLY = 2.3 Vdc to 5.5 Vdc Digital Humidity/Temp. Sensor SCL 3 VDD 2.2 2.2 0.22 µf 2 VSS SDA 4 GND Figure 6. SIP 4 Pin Mounting Dimensions, PCB Landing Pattern and Pinout [For reference only: mm/[in].) Mounting 3,90 [0.53] 4,90 [0.93] 0,063 [0.0025],905 [0.075] Landing Pattern,05 DIA. [0.040],27 [0.050] 0,65 DIA. [0.025] 5,0 [0.97],27 [0.050] 2 3 4 0.4 [0.06],20 [0.047] PCB 8,9 [0.35],2-2,0 [0.05-0.08] 0,203 [0.0080] Pin ASIC Pad Description V DD connect via 0.22 µf to ground 2 V SS supply ground 3 SCL clock 4 SDA data Tape and Reel,50 [0.059] 4,00 [0.57],75 [0.069] 0,32 [0.03] 3 [0.5] 6,00 [0.630] 5,00 [0.97] 02 [4.0] 8,00 [0.35] 2,6 [0.03] 330 [3,0] 2,4 [0.84] For orders of 250 to 000 units 0 sensing.honeywell.com

Honeywell HumidIcon Digital Humidity/Temperature Sensors Order Guide Catalog Listing HIH920-02-00 HIH920-02-00S HIH92-02-00 HIH92-02-00S HIH930-000-00 HIH930-000-00S HIH930-02-00 HIH930-02-00S HIH93-000-00 HIH93-000-00S HIH93-02-00 HIH93-02-00S Description Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH9000 Series,, ±.7 %RH accuracy, SIP 4 Pin, without filter, non-condensing, 00 units on tape Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH9000 Series,, ±.7 %RH accuracy, SIP 4 Pin, without filter, non-condensing, five units on tape (sample) Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH9000 Series,, ±.7 %RH accuracy, SIP 4 Pin, with filter, condensation-resistant, 00 units on tape Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH9000 Series,, ±.7 %RH accuracy, SIP 4 Pin, with filter, condensation-resistant, five units on tape (sample) Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH9000 Series, SPI, ±.7 %RH accuracy, SOIC-8 SMD, without filter, non-condensing, 000 units on tape and reel Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH9000 Series, SPI, ±.7 %RH accuracy SOIC-8 SMD, without filter, non-condensing, five units on tape (sample) Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH9000 Series,, ±.7 %RH accuracy, SOIC-8 SMD, without filter, non-condensing, 000 units on tape and reel Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH9000 Series,, ±.7 %RH accuracy, SOIC-8 SMD, without filter, non-condensing, five units on tape (sample) Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH9000 Series, SPI, ±.7 %RH accuracy, SOIC-8 SMD, with filter, condensation-resistant, 000 units on tape and reel Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH9000 Series, SPI, ±.7 %RH accuracy, SOIC-8 SMD, with filter, condensation-resistant, five units on tape (sample) Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH9000 Series,, ±.7 %RH accuracy, SOIC-8 SMD, with filter, condensation-resistant, 000 units on tape and reel Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH9000 Series,, ±.7 %RH accuracy, SOIC-8 SMD, with filter, condensation-resistant, five units on tape (sample) Orders of 250 units or more are packaged on tape and reel. sensing.honeywell.com

HIH9000 Series ±.7 %RH Accuracy SENSOR REHYDRATION NOTICE: SENSOR REHYDRATION Exposure to elevated temperatures, such as those experienced during solder reflow, may dry out the sensing element. It is recommended that the sensor be allowed time to rehydrate after soldering or other high temperature/dry exposures. Exposure to these conditions will not permanently damage the sensor. It will generally return to its factory-calibrated value after rehydration. If rehydration is not performed, the sensor may read a slight offset that slowly disappears over time as the sensor becomes exposed to ambient conditions. Conversely, extended exposure to condensing and high humidity environments (>90 %RH) may cause a revisable shift in readings which will generally return to normal after the sensor has been allowed to dry off. To rehydrate the sensor, expose it to room temperature under ambient conditions (>50 %RH) for a minimum of five hours. ADDITIONAL INFORMATION The following associated literature is available on the Web: Product installation instructions Product application note Application sheets: Humidity Sensor Performance Characteristics Humidity Sensor Theory and Behavior Humidity Sensor Moisture and Psychrometrics Humidity Sensor Chemical Resistivity Thermoset Polymer-Based Capacitive Sensors Technical Notes: Communication with the Honeywell HumidIcon Digital Humidity/Temperature Sensors SPI Communication with the Honeywell HumidIcon Digital Humidity/Temperature Sensors Using Alarms on the Honeywell HumidIcon Digital Humidity/Temperature Sensors Entering and Using Command Mode on the Honeywell HumidIcon Digital Humidity/Temperature Sensors WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell website, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. 2 sensing.honeywell.com

Find out more Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. To learn more about Honeywell s sensing and control products, call +-85-235-6847 or -800-537-6945, visit sensing.honeywell.com, or e- mail inquiries to info.sc@honeywell.com Sensing and Control Honeywell 985 Douglas Drive North Golden Valley, MN 55422 honeywell.com 009076-6-EN September 203 Copyright 203 Honeywell International Inc. All rights reserved.