FGT5 & FGT6 Gelation Timer. Instructions for use

Similar documents
Water Bath SWB1 SWB2 SWB3 SWB1D SWB2D SWB3D. Instructions for use Version 2.0. water bath SWB2D. mains on on. press to set. set. off.

Recirculating Cooler SRC14

Analog Melting Point Apparatus

Instruction Manual JEN0002 / Version 1.0. Peltier Accessory

Aluminum Heating Mantles

73 Series Spectrophotometer. Accessory fitting and operation manual

INSTRUCTION MANUAL (English version) Water still

Hotplate Stirrers. with BioCote antimicrobial protection

MICRO-KJELDAHL EQUIPMENT ( MM SERIES ) OPERATING AND SAFETY INSTRUCTIONS

Instruction Manual ET0002 / Version 1.0. Heating Tape

ELECTRIC BUNSEN INSTRUCTION BOOK. BA6101, BA6101/C, BA6101x1, BA6101x3. Page 1 of 20 M6877 Issue 9.6

PARAFFIN SECTION MOUNTING BATH

MD-MINI Dry Bath. Instruction Manual

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

Dry Bath Heating Systems

CR2003 ROBERTS. 3 band Auto set PLL Synthesised Clock Radio. Sound for Generations. Please read this manual before use

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

FastGene Plate Centrifuge. Instruction Manual. Catalog No. NG

Techne Dri-Block range. Premium products at affordable prices. Adjustable safety cut-out New countdown timer. 230V and 115V variants

User Instruction Manual

Digital Heat Block User Manual

Stomacher User Instructions

PAC1500Xi PORTABLE APPLIANCE CHECKER

Reacti-Therm I and III Heating/Stirring Modules

Reacti-Therm I and III Heating Modules

INSTALLATION AND USER INSTRUCTIONS COUNTERTOP AND FREE STANDING FRYERS

OPERATING INSTRUCTIONS FOR LEEC AUTOMATIC CO2 INCUBATORS. MODELS GA2000 and GA2010 MODELS GA3000 and GA3010 With Infrared CO2 detectors CONTENTS

HIn3550 Magnetic Field Monitor User's Manual

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

Shaking Hot Tubs. Orbital / Reciprocating Shaking Water Bath Liter 115V S 28 Liter 115V Liter 230V

wan Travel Kettle designed for life For model: SK27010N v3.2 SK27010N.indd 1 12/02/ :12

ES-20 Orbital Shaker-Incubator

Operator s Manual. IP-100 Immersion Probe Cooler

TTT Digital Incubator

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

TC-PLUS Thermal Cyclers

Goggle Sanitizer Cabinet

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

Optimax Refrigerated Retail Merchandisers

Corning LSE Digital Dry Bath Heater

User Instruction Manual

Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate

Kettle User Manual WKD6306W WKD6306B EN 01M M

Assembly and Operating

CR9934 ROBERTS. PLL Dual Alarm Clock Radio. Sound for Generations. Please read this manual before use

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN

Thermo-Sealer. Manual Heat Sealer. User Manual

Optimax Refrigerated Retail Merchandisers

Instruction Manual. Mini Hotplate Mini Stirrer Mini Hotplate Stirrer

SAFEVIEW-MINI2 TRANSILLUMINATOR

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

1.7 Litre Kettle v1.1. Model: SK34010 (all colours) Help line. SK34010_IM.indd 1 13/04/ :22

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

WITH OMRON E5CC CONTROL

Peltier cooler/heater PCH-1 / PCH-2

CR9986. Please read this manual before use. Dual Alarm CD Clock Radio 5/19/2005, 8:28 AM. Sound for Generations ROBERTS. CR9986 Rev 1.

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Setting the Timer...

Water Kettle. User Manual

LC3000 Level Controller Installation and Maintenance Instructions

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory)

User Guide. for the Beacon ProActTM 200 System

20 LITRE DEHUMIDIFIER

CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

Drying Cabinet With Timer

Kettle User Manual WKM6306W WKM6306B EN 01M M

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

TRAVELMATE FRIDGE FREEZER Instruction Manual

Pasto Sous vide water bath

ER MANUAL FOR YOUR BAUMATIC

Operator s Manual. Histology Bath

NEW products for 2012

Deaf & Hearing Impaired RadioLINK Alarm System

Mini Tower Fan NSMTF-18

CARIBBEAN REFRIGERATED TOPPERS

555 Hotplate 565 Magnetic Stirrer 575 Hotplate-Stirrer

Corning LSE Benchtop Shaking Incubator

User and Installation Instructions C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100

Digital 7 Square Plate Magnetic Stirrer

Instruction Manual. Please read these instructions and the Safety section carefully before using your refrigerator.

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

INSTRUCTIONS AND WARRANTY

Operation Manual Vortex mixer unitexer 1

EM, SERIES ELECTROMANTLES. INSTRUCTION BOOK

USER MANUAL LEEC CLASSIC INCUBATOR. C100, C157 and C330

identity installation & maintenance instructions customer/technical services guarantee

User Instruction Manual

Low Speed Centrifuge. Model XC-2415 Model XC-2450 Operating Manual

LABORATORY ILLUMINATED FLOTATION BATH

RETAIL MERCHANDISING UNITS

ROBERTS. FM / MW dual alarm clock radio with instant time set. Please read this manual before use

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

MS200/300/400 Hotplate Magnetic Stirrer Instruction Manual

Commercial Fan Heater

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

Operating & Maintenance Instructions 750 Vacuum Forming Machine

Alarm Tone Generator Model AG17

Transcription:

FGT5 & FGT6 Gelation Timer Instructions for use

English CLAMPING BAR PADDLE CONNECTOR PADDLE 1. Introduction Thank you for purchasing this piece of Techne equipment. To get the best performance from the equipment please read these instructions carefully before use. For your own safety and that of others please read and understand the safety advice given below before using the equipment. Before discarding the packaging check that all parts are present and correct.

2. Safety Advice before use If the equipment is not used in the manner described in this manual and with accessories other than those recommended by Barloworld Scientific the protection provided might be impaired. This equipment is designed to operate under the following conditions: - For indoor use only Use in a well ventilated area Ambient temperature range +5 C to +40 C Altitude to 2000m Relative humidity not exceeding 80% Mains supply fluctuation not exceeding 10% Over-voltage category II IEC60364-4-443 Pollution degree 2 Use with a minimum distance all around of 200mm from walls or other items The unit should be carried using both hands. Do not use in a hazardous atmospheres or with hazardous materials. Never move or carry the unit when in use or connected to the mains electricity supply. In the case of mains interruption, the unit will not restart on restoration of the electricity supply. In the case of mains interruption, the unit will reset on restoration of the electricity supply. 3. General Description The Techne Gelation Timer is the ideal instrument for accurate measurement and quality control for the gelation of resin or adhesive based samples in the laboratory. Before leaving the factory each instrument is calibrated and certificated. All models have digital timers, with the output time in 1 minute increments up to 9999 minutes, for the 1 RPM model (GT5), and in tenths of a minute up to 999.9 minutes, for the 10 RPM model (GT6). Accuracy of indicated gelation time is ±2% at a specific temperature. 4. Preparation for Use All models 4.1 Electrical Installation THIS INSTRUMENT MUST BE EARTHED Before connection please read and understand these instructions and ensure that the line supply corresponds to that shown on the rating plate. Voltage variants for these instruments are 230V 50Hz, 230V 60Hz, 120V 50Hz & 120V 60Hz. The power consumption of each unit is 5W. This unit is supplied with a mains lead which requires a rewirable mains plug to be fitted. IT IS IMPORTANT THAT THIS OPERATION SHOULD ONLY BE UNDERTAKEN BY A QUALIFIED ELECTRICIAN NOTE: Refer to the equipment s rating plate to ensure that the plug and fusing are suitable for the voltage and wattage stated. The wires in the mains cable are coloured as follows:

LIVE - BROWN NEUTRAL BLUE EARTH - GREEN/YELLOW The appropriate mains plug should be connected to the instrument BEFORE connection to the mains supply. Should the mains lead need replacement a cable of 0.5mm 2 to BS6500 & CENELEC HD21.5 should be used. IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN 4.2 To use the Gelation Timer mount the instrument clamping post onto a suitable retort stand or fixture at the desired height for operation. Ensure that the instrument is clamped firmly. 4.3 Screw the appropriate paddle to the end of the paddle connector on the sliding contact. 4.4 Connect the instrument to the electricity supply and switch on. 4.5 The instrument will perform an automatic self test at switch on. All segments will illuminate momentarily before displaying a single zero on the right hand side, a buzzer will sound and the LED should illuminate green. The gelation timer is now ready to use. 5. Operation DISPLAY LED START & RESTART BUTTON HOLD & STOP BUTTON 5.1 Sample preparation. The test requires about 100ml of sample in a container at least 38mm internal diameter. The top of the paddle stroke should be not less than 32mm below the sample surface and the bottom of stroke not closer than 13mm to the bottom of the container. Standard sample cups for use with the instrument are available (catalogue number F7846).

5.2 Starting Gelation. Having prepared the sample in the manner described, gelation time measurement can be started in one of the following ways :- 5.2.1 If you want to set up your sample under the paddle, start reaction and gelation timer simultaneously: Press the start button once. This starts the timer incrementing, the LED will flash Green and the paddle will start to reciprocate (up and down). When the sample has gelated to the extent that paddle movement is halted (circuit is closed), the timer is stopped along with the paddle, the buzzer sounds and the display will alternate between the word GEL and the indicated gelation time. This is the normal gelation mode. 5.2.2 Alternatively, if you want to start the timer as soon as the sample reaction is started: Press the Hold button once as soon as the sample is mixed, the timer starts incrementing (as gelation has started), the LED will illuminate Red, the paddle will reciprocate (up and down) and the display will alternate between the word HOLD and accumulated time. If the paddle switch is closed in the HOLD state the timer is not stopped and the paddle continues to reciprocate. This allows you time to place the sample under the paddle and get ready for gelation measurement. To commence gelation measurement once everything is set up, just press Start button once and then follow instructions shown above in 5.2.1 5.3 Accidental tripping during gelation measurement. If the paddle is accidentally tripped during gelation, the timer can be restarted by pressing Restart button once. Note: that the timer is restarted from when it was stopped, therefore the elapsed time between stopping and restarting the timer is not recorded. 5.4 Stopping during gelation measurement. The instrument can be stopped during gelation by pressing the Stop button once. The paddle stops reciprocating, the LED is extinguished and the word STOP is indicated on the display. To restart the gelation process just press the Restart button once. Note: While in stop mode, the timer will continue to run, and when restarted will indicate actual gelation time. However, if the Stop button is pressed a second time, having just stopped it, the timer will reset and the instrument will enter the Hold state, (see 5.2.2 above). 6. Maintenance, Servicing & Repair WARNING: Ensure the unit is disconnected from the mains electricity supply before attempting maintenance or servicing. This range of equipment does not require routine servicing. The only maintenance required is to clean external surfaces with a damp cloth and mild detergent. Spillages or splashes should be cleaned up straightaway after isolating the unit from the mains electricity supply. 6.1 Repairs Any repairs or replacement of parts MUST be undertaken by suitably qualified personnel. Only spare parts supplied or specified by Barloworld Scientific Ltd. or its agent should be used. Fitting of non-approved parts may affect the performance of the safety features designed into the instrument. For a comprehensive list of parts required by service engineers conducting internal repairs, or to receive a service manual, please contact the Sales Department of Barloworld Scientific Ltd quoting both the model and serial number. If in any doubt please contact the Service Department of Barloworld Scientific Ltd. 6.2 Calibration Your Gelation Timer has been carefully factory calibrated and is provided with a calibration certificate. If you require your unit to be re-calibrated at any time, please contact our Service Department of Barloworld Scientific Ltd.

6.3 Accessories A range of accessories detailed below is available for use with the Gelation Timer. Description Catalog Number Code 22mm Stainless Steel Plunger 6020985 F0985 19mm Stainless Steel Plunger 6020979 F0979 16mm Stainless Steel Plunger 6020982 F0982 Pack of 100 Disposable Plungers 6021794 F1794 Disposable Plunger Adaptor 6001795 F1795 Pack of 240 Sample Cups 6027846 F7846 7. Warranty Barloworld Scientific Ltd warrants this instrument to be free from defects in material and workmanship, when used under normal laboratory conditions, for a period of three (3) years. In the event of a justified claim, Barloworld Scientific will replace any defective component or replace the unit free of charge. This warranty does NOT apply if damage is caused by fire, accident, misuse, neglect, incorrect adjustment or repair, damage caused by installation, adaptation, modification, fitting of non-approved parts or repair by unauthorized personnel. Barloworld Scientific Ltd. Stone, Staffordshire ST15 0SA United Kingdom Tel: +44 (0) 1785 812121 Fax: +44 (0) 1785 813748 e-mail: techne@barloworldscientific.com www.barloworldscientific.com Barloworld Scientific Ltd Beacon Road, Stone, Staffordshire ST15 0SA, United Kingdom Tel: +44 (0)1785 812121 Fax: +44 (0)1785 813748 www.barloworld-scientific.com Barloworld Scientific France Ltd BP 79-77793, Nemours Cedex, France Tel: +33 1 64 45 13 13 Fax: +33 1 64 45 13 00 e-mail: bibby@bibby-sterilin.fr Techne Inc 3 Terri Lane Suite 10 Burlington NJ 08016 United States Tel: (toll free) 800-225-9243 Fax: 609-589-2571 e-mail: labproducts@techneusa.com www.techneusa.com Barloworld Scientific Italia Ltd Via Alcide de Gasperi 56 20077 Riozzo Di Cerro Al Lambro Milano Italy Tel: +392 983 8969 Fax: +392 982 30211 www.bibby-sterilin.it Afora S.A. Calle Aribau 240 08006 Barcelona Spain Tel: +343 93-306 98 00 Fax: +343 93-306 98 23 e-mail: marketing@afora.com www.afora.com