NATURAL REFRIGERANT SYSTEMS

Similar documents
SUBCRITICAL & TRANSCRITICAL SYSTEMS

MULTIPLE COMPRESSOR SYSTEMS COMPRESSOR PACKAGES ORIGINAL MANUFACTURED EQUIPMENT. Multiple Compressor Systems BA AUS

AIR COOLED CONDENSING UNIT

COMMECH SERIES AIR CONDITIONING CSH SEMI-HERMETIC SCREW PACKAGES. ORIGINAL MANUFACTURED EQUIPMENT Commech Series New Models BA AUS

LOW PROFILE EVAPORATORS

Kirby Commander Condensing Unit

Parilla Thermal Storage Project Case Study. May Page 1 of 11

Kirby CO 2 Evaporators

500 EX Fusion Compressor Series

Air-Cooled Condensing Units with Compact Screw Compressors

Suction Accumulators. Introduction. Suction Accumulators

TRENDS IN RETAIL INDUSTRY REFRIGERATION & REVIEW OF EUROSHOP 2017 EXHIBITION

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

OPERATING INSTRUCTION

commercial refrigeration products

July 2012 was a significant date for the HVAC and Refrigeration industry as it saw the introduction of the Carbon Tax and the HFC Levy.

OPERATING INSTRUCTIONS

Brazed Plate Heat Exchanger for CO Applications

PACKAGED REFRIGERATION CONDENSING UNITS

compact BOOSTER RACK TRANSCRITICAL CO 2 Cooling capacity LT: from 2 to 130 kw Cooling capacity MT: from 20 to 300 kw

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

Mechanical Systems Mechanical Systems

investment in R&D, the commitment to - name.

PACKAGED REFRIGERATION CONDENSING UNITS

Environmentally friendly refrigeration systems for industrial use

CO2 TRANSCRITICAL BOOSTER SYSTEMS

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

DRYTEC REFRIGERANT DRYERS

PS SERIES PARALLEL RACK SYSTEM GLYCOL CHILLER START UP GUIDE 11/03/2015 Rev 00

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

Rotary Screw Compressors ASD Series

PS SERIES PARALLEL RACK SYSTEM GLYCOL CHILLER START UP GUIDE. Master Rack Compressor Sequencer 7/21/2017

Environmentally friendly systems for convenience stores

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

Use of transcritical CO 2 in industrial applications

Distributed Systems Sales Brochure

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Kirby Drop-In Packaged Refrigeration Units

SEMI-HERMETIC SCREW COMPRESSORS

Air Cooled Scroll Chiller / Heat Pump

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

Air Cooled Packaged Systems AIRAH Back to Basics

EN aquatech.piovan.com

Compressed Air Products

4.1 Refrigeration process comparison

PS SERIES PARALLEL RACK SYSTEM START UP GUIDE

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

Commercial CO 2 Refrigeration Systems

COMPACT CSL range 3-20 HP

Scroll Water Cooled Chiller

With the world-renowned SIGMA PROFILE

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

ROOFTOP PACKAGED AIR CONDITIONERS

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models)

Air-Cooled Condensing Units with Bitzer Compressors

2. CURRICULUM. Sl. No.

Emerson R290 Solutions for Commercial Refrigeration Applications

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

Owner s Manual Therma-Stor II Heat Recovery System

SCR ROTARY SCREW AIR COMPRESSORS

APPLICATION OF HYDROCARBON REFRIGERANTS IN LOW TEMPERATURE CASCADE SYSTEMS

Technical Bulletin (TB-0037)

Pool heating, efficiently

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Refrigerant Type Heat Recovery Unit for Temperature & Humidity Control Room

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

CO 2 transcritical FTE System Full Transcritical Efficiency

Leadership, Innovation, Advanced Technology Synergise Here!

PRICE CHOPPER SARATOGA, NY. First cascade supermarket system in North America Installed and Started March of 2008

MSRW MINI SERIES. Modular Water Cooled Scroll Chiller MSRW075 MSRW085 Nominal Capacity 73 to 1312 kw(r) Issue: 2.0 Date 07/08

Chapter 4 Compressors Overview & System Annual Power Consumption

Atlas Copco. Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp)

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning

Kramersaver Air Cooled Condensing Units

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

THE INSTITUTE OF REFRIGERATION

Rotary Screw Compressors SK Series

Installation, Start-Up and Service Instructions

A Complete Line Of Remote Rack Refrigeration Systems

ENTHALPY TD SERIES CONDENSING UNITS. Enthalpy. Semi Hermetic TD Series Condensing Units (Medium / Low Temperature)

AE Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Refrigeration Technology in Building Services Engineering

Outdoor Condensing Unit - ZX Range. High Efficiency In Compact Design

Copeland Scroll Outdoor Refrigeration Unit

Effective and energy-conscious temperature control. Significantly increasing productivity. integrat Segmented mould temperature control

Screw Compressors ESN Fixed Speed & VS 250 Variable Speed

2-STAGE SEMI-HERMETIC

General Guidance. The easiest way to establish the amount of refrigerant in the system is to use data supplied by the manufacturer:

Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems

Powerful and reliable. Also for high ambient temperatures. weco Compact chillers

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp)

PULSE WIDTH MODULATING VALVES

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ


Smardt vs. McQuay Comparison of Standard Options and Other Benefits < 400 tons

Transcription:

R744 CO 2 SYSTEMS NATURAL REFRIGERANT SYSTEMS SINGLE & MULTIPLE COMPRESSOR SYSTEMS SUB-CRITICAL / TRANS-CRITICAL ORIGINAL MANUFACTURED EQUIPMENT R744 CO2 SYSTEMS

In 2004 BITZER Australia introduced the Enviro-Cold CO2 System to the Australian Refrigeration Industry. This was the first step in utilising CO2 in commercial refrigeration systems in Australia since the conception of refrigeration as we know it today. Since this time BITZER Australia has improved our systems to where we are today. This document provides an overall look at the full range of CO2 engineered equipment manufactured by BITZER Australia. The range includes: Generation 6 DX Hybrid Generation 7 Flooded Sub Critical Modular Cascade R134a / R744 Cobalt Unit R744 Sub Critical High Ambient R744 Booster Rack Each product has been specifically designed to suit a particular application with efficiency and safety at the forefront of our designs. Trans-Critical Development BITZER Australia continues to invest in further advancements of trans-critical CO2. Realising the increase in governmental and public awareness about issues concerning global warming potential BITZER has produced a high ambient R744 Booster System design. The purpose of this development is to provide a higher Seasonal Energy Efficiency Ratio (S.E.E.R) compared to all other systems. Further information relating to High Ambient R744 Booster Rack can be found on pgs. 13-14. Research and Development - BITZER Australia BITZER Australia has created two state of the art research and development laboratories across the two manufacturing facilities in Australia. Both facilities have fully operation R744 / CO2 plants specialising in testing compressor packages combined with heat exchange equipment. This enables BITZER to fully test and run all equipment before going to market. With this knowledge BITZER can also provide the technical support when commissioning your product for the first time. 2

CO 2 Compressor Features The BITZER Semi Hermetic reciprocating SL compressors for CO2 are the heart of BITZER Australia s R744 / CO2 natural refrigerant equipment range. The compressor range offers cooling capacity from 1.9KW to 82 KW for sub critical applications. The compressor series is characterised by improved energy efficiency, extended application limits up to a higher condensing temperature, and a permitted pressure load at the high side of 53 resp. 30 bar. The Special Highlights Highly efficient and robust working valves Advanced centrifugal lubrication system by dynamic disc Specially adapted motor version for condensing temperatures up to tc = 15 C Wear-resistant drive gear with further developed multilayer bearings Special POE oil Housing with high strength pressure High pressure side up to 53 bar Low pressure side up to 30 bar 3

Generation 6 DX Hybrid The Generation 6 (Gen 6) Low temperature R744 parallel compressor plant is the latest DX CO2 cascade system being manufactured by BITZER Australia. The Gen 6 is a cascade plant with CO2 cascade BPHE s condensers / R134a evaporating. This plant is connected to a dedicated BITZER R134a medium temperature plant. The system has key features as standard to benefit the end user and enable the system to operate as efficiently as possible. As seen in the attached drawings the air cooled de-superheater is attached to the rear of the rack fully piped and factory tested (remote fitment is possible). This reduces the high temperature system load and improves system stability / operation. In addition a hot water heat reclaimed brazed plate heat exchanger can also be fitted. Utilising this heat exchanger not only assists in removing pressure and temperature for the high side of the discharge of the CO2 plant but also provides free hot water to your facility. The system is proven technology and is commonly being used throughout supermarket and commercial plants around Australia. Features of the Gen 6 BITZER Semi Hermetic reciprocating SL compressors Compact design Easy to Service (Component accessibility) Rectangular robust frame concept, 2, 3 & 4 compressor option Solid steel construction Reduced footprint & overall dimension Compressor sub frame c/w engineered vibration mounts Quiet operation under all conditions Improved Commissioning & service access Simple transport crate design Hot Water BPHE (optional) Pressure vessels manufactured to AS 1210 & AS 2971 where applicable BITZER dual Liquid and Suction insulated header design All pipework insulated with minimum 25mm foam insulation with moulded inserts Metal clad thermal insulated suction header / accumulator 6 x 40 bar relief valves c/w changeover manifold for vessel relief valve 1 x 25 bar relief valve HP & LP Bleed / Solenoids Air Cooled De superheater installed on the rack (Remote fitment optional) Compressor and system pressure controls Emergency Cooling BPHE & Optional BITZER Integral Emergency cooling condensing unit Liquid Line By Pass Circuit 4

Generation 6 - Dimensional Data 8 7 6 5 3 4 2 1 F 1647 F E E 2543 D C C 1260 1990 D B B 305 1455 1150 00 REV. NEW DRAWINGS ECN DESCRIPTION Bitzer Australia Pty Ltd REFRIGERATION & GENERAL ENGINEERS A THE HEART OF FRESHNESS Drawn By: JX PRIVATE BAG No 7, St MARYS N.S.W 2760, Ph 02 8801 9300 FAX: 61 02 9673 4698, ACN 057 670 023, ABN 70 057 670 023 Date Drawn: 30/4/13 Checked By: CO2 DX RACK WITH T91-302 - COLES SPEC, WITHOUT HOT WATER 8 7 6 5 4 3 2 JX 30/4/13 BB 30/4/13 BY DATE CHECK DATE U.N.O TOLERANCES DECIMAL ` 1.0mm ONE DECIMAL ` 0.5mm TWO DECIMALS ` 0.2mm Third Angle Manufactured Part Purchased Part Prototype Part Scale: Not To Scale Date Checked: Sheet Number: Material: Drawing Number: 1/ 1 TBA Finish: Thickness: 1 Note drawing indicates optional accessories: Emergency Cooled Condensing Unit Hot water BPHE De-superheater fitted 5 A

Generation 7 Flooded Sub-Critical The Generation 7 (Gen 7) R134a Flooded / R744 Rack System have been designed to reduce stress on brazed plate heat exchangers with a passive R134a fully flooded / R744 thermosiphon operation. The R744 thermosiphons vapour from the top of the liquid receiver and condenses the vapour in the primary side of the BPHE returning liquid to the vessel. The R134a separation vessels floods the secondary side of the BPHE thermo siphoning back to the top of the separation vessel.the new design reduces commissioning time and provides more stable operation under all conditions as the discharge gas is diffused into the liquid refrigerant within the liquid receiver via a BITZER designed sparge tube assembly. Adding innovation to the package is the flexibility of having the compressor package and vessel package on separate frames. They can be connected front to back for a conventional installation, installed side by side or L shape to meet plant room dimensions. This also eases onsite installation. int. Features BITZER Semi Hermetic reciprocating SL compressors 2 Frame Concept with multiple mounting positions Compressor sub frame c/w engineered vibration mounts Metal clad thermal insulated suction header / accumulator 5 x 40 bar relief valves c/w changeover manifold for vessel relief valve 1 x 25 bar relief valve Easy to Service (Component accessibility) Rectangular frame concept, 2, 3 & 4 compressor option Solid steel construction Reduced footprint & overall dimension Pressure vessels manufactured to AS 1210 & AS2971 where applicable Liquid Line by pass circuit BITZER dual Liquid and Suction insulated header design Liquid separation vessel R134a c/w level probe and level switch Liquid receiver c/w low level indicator 6

Generation 7 - Dimensional Drawings 1385 1950 2331 2050 2138 1600 Note drawing indicates optional accessories: BITZER Emergency Cooled Condensing Unit Hot water BPHE 7

Modular Cascade R134a / R744 The newly developed Cascade solution by BITZER Australia provides the combination of low side R744 /CO2 and R134a high side systems into the one compact unit. This provides contractors and end users a robust construction with compact dimensions. Utilising the new SL series R744 compressors for the low temperature cascade and optimised Ecoline series for the R134a high stage and medium temperature application, this compact package delivers efficiency and energy savings with a reduced Global Warming Potential. BITZER Semi Hermetic reciprocating SL compressors BITZER Ecoline Semi Hermetic reciprocating compressors Metal clad thermal insulated suction drier / accumulator 6 x 40 bar relief valves c/w changeover manifold for vessel relief valve 1 x 25 bar relief valve Easy to Service (Component accessibility) Rectangular frame concept, 2, 3 & 4 compressor option Solid steel construction Reduced footprint & overall dimension Pressure vessels manufactured to AS 1210 *AS 2971 where applicable 8

Dimensional Drawings 8 6 7 5 4 3 2 F 1100 E 1194 3000 D 2068 1325 1941 C B 00 REV. NEW DRAWINGS ECN DESCRIPTION Bitzer Australia Pty Ltd REFRIGERATION & GENERAL ENGINEERS A THE HEART OF FRESHNESS Drawn By: JX PRIVATE BAG No 7, St MARYS N.S.W 2760, Ph 02 8801 9300 FAX: 61 02 9673 4698, ACN 057 670 023, ABN 70 057 670 023 Date Drawn: 31/7/13 Checked By: CASCADE 2 TIER RACK - R134A LOWER LAYER, CO2 UPPER LAYER 8 7 6 5 4 3 2 9 U ON TW T Date Materia Finish: Thickn

Cobalt Unit - R744 Sub-Critical The BITZER Australia Cobalt Unit is a self-contained small capacity DX CO2 Cascade low temperature system. It is designed to be close coupled to the evaporator and connected to a high side medium ring main. It has been designed to be low height so it can be installed above freezer rooms or close to cabinets. There is also the opportunity to have a dual unit which provides 2 individual circuits which can operate at differing suction temperatures. The unit has also been built around a small foot print making it perfect to fit into tight spaces. Single Cobalt Units Model Number 2MSL-07K // V10T 2KSL-1K // V10T 2HSL-3K // V25T 2FSL-4K // V200T 2DSL-5K // V200T 2CSL-6K // V200T Nominal Capacity 3.62 kw 6.00 kw 9.88 kw 14.91 kw 22.00 kw 26.7 kw Dual Cobalt Units Model Number Nominal Capacity 2 x 2MSL-07K // V10T 7.24 kw 2 x 2KSL-1K // V10T 12.00 kw 2 x 2HSL-3K // V25T 19.76 kw 2 x 2FSL-4K // V200T 29.82 kw 2 x 2DSL-5K // V200T 44.00 kw 2 x 2CSL-6K // V200T 55.20 kw Nominal Capacity given at -27 C SST, -2 C SCT Features: Electrical Board option with control of EX valve R744 high pressure vent solenoid Off cycle solenoid R744 access valves 7 Litre liquid receiver Suction to liquid plate heat exchanger Single relief valve High pressure vent control Reduced footprint & overall dimension Pressure vessels manufactured to AS 1210 *AS 2971 where applicable 10

Cobalt - Dimensional Drawings 808 670 1078 11

Booster Rack - A New Generation Two-Stage CO 2 Trans-Critical System BITZER CO2 BOOSTER RACK is a new generation of 2-stage CO2 trans-critical system in Australia. It comprises of a LT system, a MT system and a Parallel Compression system. Comparing to a standard Flash Gas Bypass CO2 trans-critical booster/cascade system currently on the market, BITZER CO2 BOOSTER RACK will produce a better Seasonal Energy Efficiency Ratio (SEER) thanks to the principle of thermodynamics for parallel compression. In other words, end users of Bitzer Australia products will benefit from consuming less energy while helping environment preservation. BITZER CO2 BOOSTER RACK is able to offer popular options such as hot gas defrost on LT evaporators, and heat reclaim from high/low side systems, etc. With two on-aboard pressure vessels, a numerous of potential opportunities could be created, for example, A/C load via a flooded BPHE. The standard features are: High stage compressor capable of handling high stage load including flash gas should the parallel compressor fail An external parallel compressor for optimising flash gas vapour duty High side heat reclaim capability Gas cooler with on-board hydro-spray system R134a emergency cooling system on MT receiver LT discharge gas for hot gas defrost on LT evaporators CAREL HP valves, receiver pressure valves, and CAREL valve drivers CAREL rack controllers and cool room controllers 12

Dimensional Drawings 2000 2450 1212 13

Additional Gen 7 Mounting Configurations 1385 1950 2331 800 949 4100 14

Dual Cobalt - R744 Sub-Critical Unit 8 7 6 5 4 3 2 906 1014 740 1780 1980 U.N.O TOLERA DECIMAL ` 1. Bitzer Australia Pty Ltd ONE DECIMAL ` REFRIGERATION & GENERAL ENGINEERS PRIVATE BAG No 7, St MARYS N.S.W 2760, Ph 02 8801 9300 THE HEART OF FRESHNESS FAX: 61 02 9673 4698, ACN 057 670 023, ABN 70 057 670 023 Drawn By: Date Drawn: Checked By: TWO DECIMALS Date Checked: Material: Finish: Third Angle Thickness: 8 7 6 5 4 3 2 15

BITZER Australia Pty Limited 134 Dunheved Circuit, St Marys, NSW 2760 Australia tel +61 (2) 8801 9300 fax +61 (2) 9673 4698 info@bitzer.com.au Victoria tel +61 (3) 8326 8200 fax +61 (3) 9310 2520 Queensland tel +61 (7) 3725 1360 fax +61 (7) 3274 3621 South Australia tel +61 (8) 8345 6110 fax +61 (8) 8268 4555 Western Australia tel +61 (8) 6350 6297 fax +61 (8) 9359 2077 BITZER New Zealand BITZER Australia Pty Ltd 9a Douglas Alexander Parade Rosedale 0632 North Shore City New Zealand tel +64 9 415 2030 www.bitzeravp.com.au www.bitzer.com.au In the interest of continuous improvement BITZER reserves the right to change the specifications or design of any of its products without notice. The BITZER Symbol, Name BITZER and model numbers are registered trade marks. All products manufactured are pending design and specification registration and must not be copied or duplicated in any way. Please note: The ISO Certification applies to New South Wales and Victoria branches only. 05.2014