Contact person Date Reference Page Christian Larsson P01958A 1 (3) Safety

Similar documents
Contact person Date Reference Page Henrik Andersson F (4) Electronics

Contact person Date Reference Page Richard Johansson P (2) Fire Research

EU-TYPE EXAMINATION CERTIFICATE

Annex of the certificate (Page 1/7) Accreditation Scope

Type: Play house Length: 1195 mm Width: 1195 mm Height: 1740 mm Materials: 18,7 mm laminated wood

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

SKG-IKOB Certificatie B.V. Trading under the names SKG, IKOB-BKB and SKW Certificatie

Contact person Date Reference Page Daniel Månsson P07886C-rev2 1 (14) Energy and bioeconomy

FG-400:2. Product registration Anti-intruder products applicable to burglary and thefts insurance. Gyldig fra

Contents CONTENTS FOREWORD REGISTRATION REGISTRATION PERIOD DISCONTINUATION OF PERFORMANCE SPECIFICATIONS...

Contact person Date Reference Page Daniel Månsson P07886E-rev2 1 (14) Energy and bioeconomy

CEN/TC 33 - Doors, windows, shutters, building hardware and curtain walling. EN 107:1980 Methods of testing windows - Mechanical test 89/106/EEC

Contact person Date Reference Page Björn Folkeson P (14) Energy and bioeconomy

Contact person Date Reference Page Daniel Månsson P07886B-rev2 1 (14) Energy and bioeconomy

Contact person Date Reference Page Björn Folkeson P (15) Energy and bioeconomy

BURGLAR, BALLISTIC, BLAST & FIRE RESISTANT SYSTEMS

ETEM SECURITY. for private and professional use

Contact person Date Reference Page Alen Rakovic P (19) Fire Research

Contact person RISE Date Reference Page Björn Folkeson P (13) Energy and circular economy

Contact person RISE Date Reference Page Daniel Månsson P (13) Energy and circular economy

6915 Highway 225, Deer Park, TX 77536

SLIP RESISTANCE TESTING OF ENDURO-MESH PANEL

Contact person RISE Date Reference Page. Daniel Månsson P (13) Energy and circular economy

General test 74 Thermal properties 75 Fire windows 75 Sound reduction 76 Safety 76 CWCT accreditation 77 Resistance to forced entry (SBD) 78

Contact person Date Reference Page Daniel Månsson P (13) Energy and circular economy

Contact person RISE Date Reference Page Björn Folkeson P03675B 1 (11) Energy and circular economy

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

ISO CERTIFICATE nr/ no.5690 M. SP Sveriges Tekniska Forskningsinstitut

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

ISO INTERNATIONAL STANDARD. Fire-fighting hoses Rubber and plastics suction hoses and hose assemblies

Contents EN :2006+A2:2016 (E)

V DG UV Test. EC-Type Examination (Module B) Certificate. Certificate No A.1/3.34 Fire resisting divisions for high speed craft

gb# DG UV Test EC-Type Examination (Module B) Certificate Certificate No A.1/3.34 Fire resisting divisions for high speed craft

Drawer fronts: 16 mm particleboard Doors: 16 mm particleboard This report covers the models Nonstop, Sprinter, Genese

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

SPCR 183. RISE Research Institutes of Sweden AB Certification SPCR

GASTEC QA. Approval Requirements 31-2

Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves.

Fire and Security Products and Services

GUIDELINIE ECB S R10. March European Certification Body GmbH

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

TEST REPORT. Glass mosaic, 25 mm x 25 mm. Ref.: -- Serie: Code laboratory: 38-16

BRL-K774/ Evaluation guideline. for the Kiwa product certificate for Compression fittings to tighten with matching clamping device

gb# DG UV Test EC-Type Examination (Module B) Certificate Certificate No A.1/3.34 Fire resisting divisions for high speed craft

TEST REPORT No

P.O. Box NL-2665 ZN Bleiswijk Brandpuntlaan Zuid 16 - NL-2665 NZ Bleiswijk The Netherlands

LATCH UP TEST REPORT

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

Requirements specification physical protection, in order to receive a National Indemnity

European Parliament and of the Council with regard to energy labelling of residential ventilation units. (Text with EEA relevance) (2016/C 416/06)

ISO INTERNATIONAL STANDARD. Geotechnical investigation and testing Field testing Part 1: Electrical cone and piezocone penetration test

Full-scale test of fire detection in a facade using heat detection cable and flame detector

STÅLPROFILSYSTEM SP 35000

Shops and Businesses Page 1/5

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

For each product, the standard or normative document and certification scheme in accordance with ISO/IEC are listed below. normative document

EC DECLARATION OF CONFORMITY

This document is a preview generated by EVS

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

TFI Report Classification

NOVOLAY secure. PYRANOVA secure. Special glass types with outstanding safety properties

ADDITIONAL REQUIREMENTS

Specimen delivery date: Test date: Sampling: The test specimen sampled by customer. Order description N o 152/

Analysis Report

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13

On Electromagnetic Compatibility

Fire damper DESIGN GENERAL FIRE CELL DIVISION DISTRIBUTION OF RESPONSIBILITIES FIRE PROTECTION DOCUMENTATION HAGAB FIRE DAMPER DESIGN

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415

ISO INTERNATIONAL STANDARD

GASTEC QA. Approval Requirements 31-1

American National Standard

GASTEC QA. Evaluation Guideline KE 192. Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment

Certificate of constancy of performance

POLYMER MANAGEMENT IN DIFFERENT INDUSTRIES

Fapim spa. Dutch Buildings Decree SKG ENG. Building hardware

G4S ACADEMY BURGLAR-RESISTANT GLASS DISPLAY CASES & EXHIBITION ROOMS

Perform on-site emergency troubleshooting, programming, and repair of our fire alarm, burglar alarm, access control and video surveillance systems.

25 th November Title:

SVENSK STANDARD SS-EN Fönster Mjuk och tung stöt Provningsmetod, säkerhetskrav och klassificering

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

ISO 9001 CERTIFIKAT CERTIFICATE. nr/no Härmed intygas att:/this is to certify that:

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

ANSI/AHRI Standard 1351 (SI) 2014 Standard for Mechanical Performance Rating of Central Station Air-handling Unit Casings

CERTIFICATE OF COMPLIANCE

ISO INTERNATIONAL STANDARD. Determination of the resistance to jet fires of passive fire protection materials Part 1: General requirements

Testing of dehumidifiers (1 appendix)

Amendment to Test Report

dhf General Information Automated Gates Guidance for enforcement bodies

G4S ACADEMY STANDARDS COMPARISON KEY

T.Y.C. BROTHER IND. CO., LTD.

Transcription:

issued by an Accredited Testing Laboratory Contact person Christian Larsson 2016-09-05 6P01958A 1 (3) Safety +46 10 516 57 61 Christian.Larsson@sp.se Accred. No. 1002 Testing ISO/IEC 17025 Olar-Portconsult AS Smalvollveien 26-28 NO-0667 Oslo Norge Test of burglary resistance according to SS-EN 1627 (2 appendices) Summary A burglary resistance test of Olar-portconsult AS roller shutter designated OMEGA FG Klasse 2 has been performed according to SS-EN 1627:2011 RC2. The test object fulfilled the requirements according to SS-EN 1627:2011 RC2 from the outside and inside for niche mounting and wall mounting. The report is not and should not be invoked as an approval or certification of the product. 1 Introduction By commission of Olar-portconsult AS a burglary resistance test of a roller shutter have been performed in accordance with SS-EN 1627:2011 RC2. The purpose of the test was to evaluate if the test object fulfilled the requirements for classification RC2. 2 Test object Tested object: Manufacturer: Description of the sample: Total width: Total height: Drawings: Type of lock: Assembly instruction: Roller shutter OMEGA FG Klasse 2 configuration according to drawing in appendix 1. Mortise lock in the centre of the bottom beam is not necessary to fulfil RC2. Olar Industrier AS Roller Shutter, classed as a group 3 product according to SS- EN 1627:2011. 5000 mm. 2750 mm. See appendix 1. 2 pcs padlock Class 3 according to SSF 014 one on each side confirming to Annex B, Table B.1 in EN 1627:2011. An assembly instruction giving the minimum amount of information according to SS-EN 1627 is enclosed to the documentation, see appendix 2. Postal address Office location Phone / Fax / E-mail Laboratories are accredited by the Swedish Board for Accreditation and SP Box 857 SE-501 15 BORÅS Sweden Brinellgatan 4 SE-501 15 BORÅS +46 10 516 50 00 +46 33 13 55 02 info@sp.se Conformity Assessment (SWEDAC) under the terms of Swedish legislation. This report may not be reproduced other than in full, except with the prior written approval of the issuing laboratory.

2016-09-05 6P01958A 2 (3) 3 Test method and performance Test method: Test date: 2016-02-11. Test facility: Test leader: Time keeper: Tester: Ambient temperature: 20.5º C. Relative humidity: 38 %. 4 Test results Burglary resistance test according to: SS-EN 1628:2011 Pedestrian door sets, windows, curtain walling, grilles and shutters Burglar Resistance Test method for the determination of resistance under static load. SS-EN 1629:2011 Pedestrian door sets, windows, curtain walling, grilles and shutters Burglar Resistance Test method for the determination of resistance under dynamic loading. SS-EN 1630:2011 Pedestrian door sets, windows, curtain walling, grilles and shutters Burglar Resistance Test method for the determination of resistance to manual burglary attempts. SP Safety Mechanics Research in Borås, Sweden. Christian Larsson. Lars-Ove Johansson and Christian Larsson. Christian Larsson and Lars-Ove Johansson. The test results shown in this report refer only to the tested objects and are valid only in the condition the test was performed. 4.1 Static load in accordance with SS-EN 1628 Table 1. Static load in accordance with SS-EN 1628 RC2 Loading Position Test load Limiting value Result points [kn] F1.1 Side 3 30 OK F1 Side 3 10 mm OK F2 Center 1.5 10 mm OK F2 Center down 1.5 10 mm OK F3 Center 3 Gap gauge C (50 mm) OK F3 Corner 3 Gap gauge C (50 mm) OK The requirements in SS-EN 1627 for static load resistance class RC2 were fulfilled. 4.2 Dynamic load in accordance with SS-EN 1629 Table 2. Dynamic load in accordance with SS-EN 1629 RC2 Mass of the impactor: 50 kg Drop height [mm] 450 mm The requirements in SS-EN 1627 for dynamic load resistance class RC2 were fulfilled.

2016-09-05 6P01958A 3 (3) 4.3 Manual burglary attempts in accordance with SS-EN 1630 Table 3. Manual burglary attempts in accordance with SS-EN 1630 Zone of attack Used tools Operative time Description [min s ] Accessible opening Pipe wrench, > 3 OK for RC2 side. polygrip, knife Accessible opening Pipe wrench, > 3 OK for RC2 center. Breaking the side try to bend out the panels. polygrip, knife Screwdriver > 3 OK for RC2 Locks and electrical switch. Screwdriver and hammer > 3 OK for RC2 The requirements in SS-EN 1627 for manually burglary resistance class RC 2 were fulfilled. 4.4 Classification The test specimen was subjected to the described tests defined in SS-EN 1627: 2011 and was judged to fulfil the requirements of resistance class given below from the outside and inside for niche mounting and wall mounting. RC2 Any additional change in design / construction is only allowed upon written permission and/or testing by the testing laboratory (see SS-EN 1627 Annex D). 5 Measurement uncertainty The measurement uncertainty for the applied load is 1.3% and for deformation measurement 1.6 %. Safety - Mechanics Research Performed by Examined by Signature_1 Christian Larsson Signature_2 Peter Blomgren Appendices 1: Drawing 2: Technical documentation

2016-09-05 6P01958A 1 (1) Appendix 1

2016-09-05 6P01958A 1 (2) Appendix 2

2016-09-05 6P01958A 2 (2) Appendix 2