Wireless Light Detection Sensor

Similar documents
VDC. Wireless AC Voltage Detection Sensor. The Leader in Low-Cost, Remote Monitoring Solutions. General Description. Monnit Sensor Core Specifications

Wireless DC Voltage Detector

~500 V AC / DC. Wireless 500 VAC/VDC Voltage Meter. The Leader in Low-Cost, Remote Monitoring Solutions. Monnit Sensor Core Specifications

Wireless Duct Temperature Sensor

Wireless Thermocouple Sensor

Wireless 0-5 Volt Meter Sensor

The Leading Enterprise Internet of Things Solution. Wireless Open / Closed Sensors OPEN / CLOSED. Features of Monnit ALTA Sensors. General Description

The Leading Enterprise Internet of Things Solution. Wireless AC Voltage Detection Sensors ( VAC) VOLTAGE DETECT. General Description

The Leading Enterprise Internet of Things Solution. Wireless Dry Contact Sensors. General Description. Features of Monnit ALTA Sensors

The Leading Enterprise Internet of Things Solution. Wireless Duct Temperature Sensors. General Description. Features of Monnit ALTA Sensors

Wireless Water Detection Sensors General Description Features of Monnit ALTA Sensors Water Detection Principle of Operation

The Leading Enterprise Internet of Things Solution. Wireless Thermocouple Sensors. General Description. Features of Monnit ALTA Sensors

The Leading Enterprise Internet of Things Solution. Wireless 0-20 ma Current Meters. General Description. Features of Monnit ALTA Sensors

VDC. The Leading Enterprise Internet of Things Solution. Wireless DC Voltage Detection Sensors (0-50 VDC) General Description

The Leading Enterprise Internet of Things Solution. Wireless Thermocouple Sensors. Features of Monnit ALTA Sensors. General Description

Frequently Asked Questions

Smart Monitoring Systems. for Property Management SMART SOLUTIONS. Property Management DOORS & WINDOWS TEMPERATURES LIGHTS CARBON MONOXIDE

Photoelectric Beam Detector

TotalPac X Single interlock SUREFIRE system

TotalPac X Firecycle III Preaction Double interlock system

HOBO U30 Remote Monitoring Systems

Ion Gateway Cellular Gateway and Wireless Sensors

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

ON THE BUTTON A reference guide to environmental ratings used for push button enclosures

Fiber Optic Cable Fence Disturbance Sensor

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

Architectural and Engineering Specification for a. Flash / Flare

Ross SysCon Control Panels

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

Instruction Manual. Self-Leveling Rotary Laser Level Model Nos and

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY


wireless. web-based. worthy of the name RACO.

Quick Touch Pendant User Guide

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

Architectural and Engineering Specification for a Real-Time Locating System Flare

GLD-30 Gas Leak Detector

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

FLOOD SERIES DATA SHEET

BSC-50 ADU-500. Autonomous RTUs

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

Product Catalogue. Complete Wireless Sensor Solutions SYSTEMS. 100% Peace of Mind! WEB ID WEB ID WEB ID

Selecting an Electrical Enclosure

Temperature Monitoring, Operation and Maintenance of Research Freezers and Refrigerators SOP-TMOMRFR-01

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Industrial Grade Gas Detection

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

LIGHTNING PROTECTION SYSTEM

ACTIVE INFRARED BARRIER

Operation and Maintenance Manual

DD205RF/TX Detector Installation Sheet

DS500. Alarm Sensors (built in) Power. Sounds. Accessories* Attachment

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Custom Duct Heaters. Special Applications

Open-area Smoke Imaging Detection (OSID)

Self-Leveling Five-Beam Laser Pointer Model No Instruction Manual

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

ALTAIR 5X Multigas Detector Product Specification


Macurco HD-11 Hydrogen Gas Detector

Essential Insight.mesh Wireless System,

Toxic Gas Detection. Model F12. Toxic Gas Detection

Helical Coil Heaters. Hot Oil Heaters Booster Heaters. CEI Enterprises

Mobeye CM2410 GSM fire alarm communicator

DATAssure. Laboratory wireless alarm & monitoring system

REMOTE MONITORING AND ALARM SYSTEM

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

Quick Touch Pendant. Quick Touch Pendant. Battery

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

ENCLOSURE COOLING. Glossary

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

environmental chambers for Battery testing

Fire Alarm System Accessories

Honeywell Temperature & Humidity Sensor with LCD

Vive PowPak Fixture Controls

Monnit Wireless Local Alert. User s Guide

Filtrex A Smoke Detector for Difficult Environments

Preliminary. SmarteLight v1.2 Manual. Revision: 1.0 Date: 12/4/2012. Revision: 1.0 Page i OmniSite

EWR2 WIRELESS SIGNAL REPEATER

GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Custom Duct Heaters. Special Applications

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Тел: Моб: Skype: Discoverytelecom Mail: EWK2 EWK2A WIRELESS KEYFOB

Arlo Wire-Free Smart Security Lights. No cords. No wires. No worries. 100% Wire-Free. Fully Customizable. Works with Arlo Camera Systems

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Direct Draw Equipment

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

Hazardous area descriptions

IN A BOX. User Manual YOUR HOME SECURITY SYSTEM. curv360.co.uk. Support APP remote arm/disarm, parameter settings and accessories management

Motorised Infrared Optical Beam Smoke Detector. User Guide

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

Transcription:

The Leader in Low-Cost, Remote Monitoring Solutions Wireless Light Detection Sensor LIGHT DETECTION General Description The Wireless Light Detection Sensor detects the presence of light. Features Detects presence of light Principle of Operation Free imonnit basic online wireless sensor monitoring and notification system to configure sensors, view data and set alerts via SMS text and email. The Wireless Light Detection Sensor uses a photo resistor to detect the presence of light around the device. The sensor returns a value of light or no-light to the imonnit Online Sensor Monitoring and Notification System. The data is stored in the online system and can be reviewed and exported as a data sheet or graph. Notifications can be set up through the online system to alert the user when light is present or not with the ability to only notify within time of day parameters. S( λ) rel - Relative Spectral Sensitivity 20019 1.0 0.9 0. 8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 300 400 500 600 700 800 900 1000 1100 λ - Wavelength (nm) Fig. 1 - Relative Spectral Sensitivity vs. Wavelength Monnit Sensor Core Specifications : 250-300 ft. (non-line-of-sight / indoors through walls, ceilings & floors) * Communication: RF 900, 920, 868 and 433 MHz Power: Replaceable batteries (optimized for long battery life, line-power and solar (Industrial only) options are available. Battery Life (at 1 hour heartbeat setting): ** Coin Cell > 2-3 years. AA battery > 4-8 years Industrial > 4-8 years * Actual range may vary depending on environment. ** Battery life is determined by sensor reporting frequency and other variables. Example Applications Facilities management. Commercial property management. Home light monitoring. Small business light monitoring. And many more... 0 10 20 30 S rel - Relative Sensitivity 1.0 0.9 0. 8 0.7 40 50 60 70 80 ϕ - Angular Displacement 20160 0.6 0.4 0.2 0. 2 - Relative Radiant Sensitivity vs. Angular Displacement

1.125 in (28.575 mm) 2.0 in (50.8 mm) 0.875 in (22.225 mm) Wireless Light Detection Sensor (Coin Cell) - Technical Specifications Current Consumption 6 µa (accelerometer listening for vibrations) 0.7 µa (sleep mode after measurement) Operating Temperature Range (Board Circuitry and Coin Cell) -7 C to +60 C (20 F to +140 F) ** Optimal Battery Temperature Range (Coin Cell) PinchPower Enclosure +10 C to +50 C (+50 F to +122 F) 0.7 oz Range may vary according to environmental variables. _ CR2032 BATTERY CR2032 BATTERY + Pinch (press in on the sides) Pull (sensor away from base) Press (sensor back into base) PAGE 2

2.470 2.470 4.375 3.295 1.111 1.111 Wireless Light Detection Sensor (AA) - Technical Specifications Current Consumption 6 µa (accelerometer listening for vibrations) Operating Temperature Range (Board Circuitry and Batteries) Optimal Battery Temperature Range (AA) 0.7 µa (sleep mode after measurement) -18 C to 55 C (0 F to 130 F) using alkaline -40 C to 60 C (-40 F to 140 F) using lithium ** +10 C to +50 C (+50 F to +122 F) 3.7 oz. Range may vary according to environmental variables. Power Options Two replaceable 1.5V AA sized batteries are included with the standard model. A line-power version with battery backup is also available - allowing it to be powered by a standard 3.0-3.6V power supply and use the internal batteries if there is a power interruption. Power options must be selected at time of purchase as the internal hardware of the sensor must be changed to support the selected power requirements. PAGE 3

Industrial Wireless Sensor 2.316 in (58.84 mm) 3.701 in (94.0 mm) Height: 1.378 in (35.0 mm) Wireless Light Detection Sensor (Industrial) - Technical Specifications Current Consumption 0.7 µa (sleep mode) Operating Temperature Range (Board Circuitry and Battery) Included Battery Max Temperature Range: -40 C to +85 C (-40 F to +185 F) ** Capacity: 1800 mah Optional Solar Feature Solar Panel: 5VDC / 30mA (53mm x 30mm) Charging Temperature Range: 0 C to 45 C (32 F to 113 F) Max Temperature Range: -20 C to 60 C (-4 F to 140 F) Included Rechargeable Battery: 600 mah / >2000 Charge Cycles (80% of initial capacity) Enclosure Rating NEMA 1, 2, 4, 4x, 12 and 13 rated, sealed and weather proof UL Rating UL Listed to UL508-4x specifications (File E194432) 4.7 oz Range may vary according to environmental variables. Solar Power Option Monnit Industrial Sensors are powered by a replaceable 3.6V Lithium battery (included). An optional solar powered version is also available. The solar powered sensor uses a Lithium Iron Phosphate rechargeable battery in conjunction with a solar power cell to extend battery life. PAGE 4

Notes: Commercial Grade Sensors Monnit commercial grade sensors are designed for applications in ordinary environments (normal room temperature, humidity and atmospheric pressure). Do not use these sensors under the following conditions as these factors can deteriorate the product characteristics and cause failures and burn-out. Corrosive gas or deoxidizing gas - chlorine gas, hydrogen sulfide gas, ammonia gas, sulfuric acid gas, nitric oxides gas, etc.) Volatile or flammable gas Dusty conditions Under low or high pressure Wet or excessively humid locations Places with salt water, oils chemical liquids or organic solvents Where there are excessively strong vibrations Other places where similar hazardous conditions exist Use these products within the specified temperature range. Higher temperature may cause deterioration of the characteristics or the material quality. Industrial Grade Sensors - Type 1, 2, 4, 4X, 12 and 13 NEMA Rated Enclosure Monnit s Industrial sensors are enclosed in reliable, weatherproof NEMA rated enclosures. Our NEMA rated enclosures are constructed for both indoor or outdoor use and protect the sensor circuitry against the ingress of solid foreign objects like dust as well as the damaging effects of water (rain, sleet, snow, splashing water, and hose directed water). Safe from falling dirt Protects against wind-blown dust Protects against rain, sleet, snow, splashing water, and hose directed water Increased level of corrosion resistance Will remain undamaged by ice formation on the enclosure For more information about our products or to place an order, please contact our sales department at 801-561-5555. Visit us on the web at www.monnit.com. Monnit Corporation 3400 South West Temple Salt Lake City, UT 84115 801-561-5555 www.monnit.com Monnit, imonnit and all other trademarks are property of Monnit, Corp. 2018 Monnit Corp. All Rights Reserved. MDS-010-1B (1/18)