EESTI AKREDITEERIMISKESKUS ESTONIAN ACCREDITATION CENTRE

Similar documents
EESTI AKREDITEERIMISKESKUS

LISA Tallinna Vesi AS akrediteerimistunnistusele nr L065 ANNEX to the accreditation certificate No L065 of Tallinn Water Ltd

EESTI AKREDITEERIMISKESKUS ESTONIAN ACCREDITATION CENTRE

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

EESTI AKREDITEERIMISKESKUS ESTONIAN ACCREDITATION CENTRE

EESTI AKREDITEERIMISKESKUS ESTONIAN ACCREDITATION CENTRE

ESD500. ESD500 Combustible / Toxic Gas Detector

ESD3000 ESD200 Combustible / Toxic Gas Detector

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

SP-220. Features. Combustible handheld gas leakage detector

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Low mg/m

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

GAS DETECTOR ST400EC PART.NO

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

Glenside Environmental Services Ltd

IMO Resolution MSC 61(67): Annex 1: Part 2

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

Portable Instrument Application Guide

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Thermo Scientific TVA2020 Introduction

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Technical manual 2G-TA 04 - Gas

OLC(T) 100 FIXED GAS DETECTOR

3M Oldham OLCT 100. Description. Fixed Gas Detector

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Monitores Personales. Personal Monitor

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Review Fire Test Report

Micro III (Models G203, G203S, and G213) Operation Manual

EAK AKREDITEERITAVAD TAVAD VASTAVUSHINDAMISMENETLUSED EAK INF1 2016

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Explosion protection Marijan Gorše, dipl. ing.

GAS CONDENSING TECHNOLOGY

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

MICRO III (G202 / G202s / G212) Single Gas Detector

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

OXYGEN. 21% in air. Does not burn - Supports combustion. Increased oxygen will intensify burning

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

ACTIVITIES OF THE MEASURING GROUP

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

INTERNATIONAL STANDARD

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

MICRO IV. Operation Manual. Single Gas Detector

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

Sieger Apex. Flexibility that meets your requirements

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

CEM Istanbul - Turkey. True trace emission monitoring system

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

ALTAIR 5X Multigas Detector Product Specification

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

GAS ANALYSIS / DETECTION Gas Detector

Test procedure/ method identification IP 100 (ISO 9096, ČSN EN )

Key Performance. CompactGC 4.0

MSA XCell Sensors. Because every life has a purpose

portable gas analyser

Frequently Asked Questions

STS Directory Accreditation number: STS 0021

PRODUCT CONFORMITY CERTIFICATE

Airborne Hazard Emergency Response

ALTAIR 5X Multigas Detector

Your trusted partner in providing the best fixed Gas Detection Sales and Service in Western Canada

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

APPLICATION DATA SHEET

MICRO IV. Installation & Maintenance Instructions. (G221 / G222 / G223) Single Gas Detector


Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Soft Ionisation Techniques, Terry Whitmore, Hiden Analytical

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

INDUSTRIAL BOILER MACT GUIDELINES

Understanding the Balance

Anorganic Fertilizer. Lenny Sri Nopriani, SP.MP

Know Your Soil Getting the Dirt on Your Dirt FWAA. Dr. Steve Petrie Director of Agronomic Services

Joint Stock Company Alzida Savanorių pr. 221, LT Vilnius, Lithuania

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

Micro IV. Single Gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

Model D12. Digital Gas Transmitter

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

Single Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3

Rol van ISSeP als sectoraal operator

CANADIAN FIRE ALARM ASSOCIATION An Update on Standards, Technologies and Solutions. Smoke Characterization Study

Gas detector tubes are most effective as a reference device for conducting spot checks, which gives an idea of present gas at that moment in time.

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

Monitoring Nutrition for Crops

An easy and flexible way to do gas detection.

Transcription:

1 (6) EESTI AKREDITEERIMISKESKUS ESTONIAN ACCREDITATION CENTRE Lisa TTÜ energiatehnoloogia instituudi akrediteerimistunnistusele L028 ANNEX to the accreditation certificate L028 of Tallinn University of Technology Department of Energy Technology 1. Akrediteerimisulatus on toodud järgnevas tabelis: Accreditation scope is given in the following table: Kütused, kütuste tuhk, katla sadestised. Solid mineral fuels, fuel ashes, boiler deposits. 1. SiO 2 sisalduse määramine. Determination of SiO 2 (0,3 99,5) % DIN 51729, osa 2 p.1 2. Fe 2O 3 sisalduse määramine. Determination of Fe 2O 3 3. R 2O 3 ja Al 2O 3 sisalduse määramine. Determination of R 2O 3 and Al 2O 3 4. CaO sisalduse määramine. Determination of CaO 5. MgO sisalduse määramine. Determination of MgO 6. Na 2O ja K 2O sisalduse määramine. Determination of Na 2O and K 2O 7. Cl sisalduse määramine. Determination of Cl Bromiidi, kloriidi, fluoriidi, nitraadi, nitriti, fosfaadi ja sulfaadi määramine. Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate 8. Üldväävli sisalduse määramine Eschka meetodil. Determination of sulphur by Eschka method 9. Üldväävli ja kloorisisalduse määramine Determination of total content of sulphur and chlorine Tahked biokütused Solid biofuels Jäätmekütused Solid recovered fuels 10. Sulfaatse väävli sisalduse määramine. Determination of sulphur bonding forms (0,3 50) %. STI-1-2005 Spekrofotomeetriline analüüs Spectrophotometric analysis (0,5 30) % STI-2-2005. (0,5 50) % DIN 51729, osa 6, p.2 Volumetric anal. (0,5 50) % DIN 51729, osa 7, p.2 Volumetric determination (0,5 10) % DIN 51729, osa 8 Leekfotomeetriline analüüs Flame-photometric analysis (< 0,1 10) % EVS-EN 196-2: 2013; ISO 587:1997: Volumetric determination EVS-EN ISO 10304-1:2009 Vedelikkromatograafia Liquid chromatography of ions (0,05 20) % EVS 664:2017 Cl 500 mg/kg >500 mg/kg S 500 mg/kg >500 mg/kg EVS-EN ISO 16994:2016 S -. Cl - Volumetric determination. EVS-EN 15408:2011 (0,05 20) % EVS 664-2017.

2 (6) 11. Tahked biokütused vees lahustuva kloriidi, naatriumi ja kaaliumi sisalduse määramine Solid biofuels - Determination of the water soluble content of chloride sodium and potassium 12. Sõelanalüüs Tahked kütused (solid fluel) Size analysis by sieving 13. Sõelanalüüs Methods for the determination of particle size Tahked biokütused Solid biofuels Jäätmekütused Solid recovered fuels 14. Kütuste tuha sulamiskarakteristikute määramine Determination of ash fusibility. Tahked biokütused. Solid biofuels Method for the determination of ash melting behaviour. Part 1 Characteristic temperatures method 15. Vaba CaO sisalduse määramine. Determination of free CaO Cl 500 mg/kg >500 mg/kg Na,K 100 mg/kg >100 mg/kg < 1350 o C õhu keskkonnas EVS-EN 16995:2015 Cl - Volumetric determinationl. Na ja K Leekfotomeetriline analüüs Flame-fotometric analysis ISO 1953:2015; DIN 66165 1, osa 2 Sõelanalüüs Size analysis Sõelanalüüs Size analysis EVS-EN ISO 17827-1; 2:2016; EVS-EN 15415-1:2011 ISO 540:2008 CEN/TS 15370-1:2006 Instrumentaalne temp.meetod Characteristic temp.method CEN/TR 15404:2010 (0,5 20) % STI 3-2005 ALA CL-A,3,7 Volumetric determination Tahked kütused Solid minerals fuels 16. Tuhasisalduse määramine: Determination of ash content 1. tahkes kütuses (solid fuel) 2. turbas (peat) (0,05 90) % GOST 11022-95, ISO 1171:2010; EVS 669-96 3. biokütuses (biofuel), puidus (wood) (0,1 95) % EVS-EN ISO 18122:2015 4. paberis (paper), papis (board), (0,05 90) ISO 2144:2015; ISO 1762:2015 tselluloosimassis (pulp) % 5. jäätmekütuses (solid recovered fuel) (0,1 95) % EVS-EN 15403:2011 17. Niiskusesisalduse määramine. Determination of moisture content 1. tahkes kütuses (solid fuel) >0,5 % EVS 668-96; ISO 589:2008 met. C; ISO 579:2013(E); ISO 5068:2007 Kuivatuskaal Moisture /Balance HA 300 2. biokütuses (biofuel), puidus (wood) EVS-EN ISO 18134-1:2015 EVS-EN ISO 18134-2:2017 EVS-EN ISO 18134-3:2015 3. paberis, papis, tselluloosimassis EVS-EN ISO 287-2009 4. jäätmekütuses (solid recovered fuel) CEN/TS 15414-1:2010 18. Kütteväärtuse määramine kalorimeetrilise pommi meetodil. Determination of gross calorific value by calorimeter bomb method Tahked biokütused. Solid Biofuels Method for the determination of calorific value. Jäätmekütused.Solid recovered fuels. Ehitusmaterjalide tulekindluse test Reaction to fire tests for building products Determination of the heat of combustion. alates 3,2 MJ/kg (0 3,2) MJ/kg GOST 147-95; EVS-ISO 1928:2016 EVS-EN ISO 18125:2017 EVS-EN 15400:2011 EVS-EN ISO 1716:2010 Kalorimeetrilise pommi meetod Calorimeter bomb method

3 (6) 19. Lendosade sisalduse määramine. Determination of volatile matter 20. Karbonaatse CO 2 sisalduse määramine. Determination of carbon dioxide content of the carbonates 21. Püriitväävli sisaldus. Determination of sulphur bonding forms 22. ph määramine Determination of ph ph määramine leostusmeetodiga Determination of ph by leaching test 23. Kuumutuskao määramine Determination of loss on ignition Sõelanalüüs (size analysis by sieving) ISO 562:2010 GOST 6382-2001 ISO 5071-1:2013 (0,5 90) % EVS-EN ISO 18123:2015 (1,0 50) % ISO 925:97 (0,1 5) % EVS 664:2017 meetod a Kütused, kütuste tuhk, katla sadestised, turvas, pinnas Solid mineral fuels, fuel ashes, boiler deposits, peat, soil Grillsüsi Barbecue charcoal 24. Niiskus (determination of moisture) Tuhasisaldus (determination of ash contest) Lendosad (determination of volatile matter) Seotud süsinik (determination of fixed carbon) 0,5 % 0,1 % alates 5 % Isesüttivustemperatuur. (ing for selfheating subtances) Vedelkütused 25. Niiskuse sisalduse määramine Determination of moisture content 26. Kütteväärtuse määramine kalorimeetrilise pommi meetodil. Determination of gross calorific value by calorimetric bomb method 27. Väävlisisalduse määramine põletamisega kalorimeetrilises pommis. Determination of sulphur by calorimetric bomb method 28. Kustumiskiiruse määramine Reactivity 29. Mehhaanilise vastupidavuse määramine Determination of mechanical duralibility 4 12 ISO 10390:2005 Instrumentaalne meetod Instrumental method EVS-EN 12457-2:2003 (0,1 90) % EVS-EN 196-2 p.7:2013 s ISO 579:2013(E) ISO 1171:2010 ISO 562:2010 Arvutuslik (juhend) Matematical calculation (guide) Sõelanal. Size analysis EVS-EN 1860-2:2005, ISO 1953:2015 UP 1361 Part III, section 33.3 STI 3-16 Petroleum products 0,5 % STI 4-16 gravimetric determination Alates 3200 J/g GOST 21261-91 Kalorimeetrilise pommi meetod Calorimetric bomb method (0,05 5) % GOST 3877-88 kaalanalüüsiga gravimetric determination Ehituslubi Building lime 80 o C 30 min Pelletid Pellets EVS-EN 459-2:2010 p.6.6 < 100 % EVS-EN ISO 17831-1:2015 kaalanalüüs gravimetric determination

4 (6) Orgaanilised ja anorgaanilised tahked ja vedelad ained, mittehomogeensed ja kergelt lenduvad ained Organic and inorganic solid and liquid substances 30. C, H, N, S ja O määramine elementaaranalüsaatoriga. Determination of C, H, N, S, and O with elemental analyser 31. Üldise C, H ja N määramine tahketes biokütustes-instrumentaalsel meetodil Solid biofuels- Determination of total content of C, H, and N instrumental methods 32. C, H ja N määramine jäätmekütustes-instrumentaalsel meetodil. Solid recovered fuels. Determination of C, H and N - instr. methods Instrumentaalne meetod Instrumental method (0,03 20) mg Elementar analyser kasutusjuhend EVS-ISO 29541:2015 C>0,1 % N>0,01 % H>0,1 % EVS-EN ISO 16948:2015 EVS-EN 15407:2011 Ehitus- ja isolatsioonimaterjalid Building and Insulation materials 1 Soojusjuhtivusteguri määramine Thermal conductivity testing (0,005 0,35) W/(m K) Mõõtemääramatus* Uncertainty* Märkus: mõõtemääramatus on esitatud laiendmääramatusena U (k=2) normaaljaotuse järgi Statsionaarsete saasteallikate õhuheitmed 3 % EVS-EN 12667:2001, 1. Hapnik, O 2 (0,2 25) vol-% Oxygen 2. Süsinikdioksiid, CO 2 (0,2 25) vol-% Carbon dioxide 3. Süsinikmonooksiid, CO (2 5000) ppm Carbon monoxide 4. Lämmastikoksiid, NO (2 500) ppm Nitrogen oxide 5. Lämmastikdioksiid, NO 2 (2 100) ppm Nitrogen dioxide 6. Lämmastikoksiid, N 2O (2 100) ppm Nitrous oxide 7. Vääveldioksiid, SO 2 (2 2000) ppm Sulpfur dioxide 8. Vääveltrioksiid; SO 3 (2 200) ppm Sulpfur trioxide 9. Vesinik kloriidhape ; HCl (2 300) ppm Hydrogen chloride 10. Tsüaanvesinik; HCN (2 300) ppm Hydrogen cyanide 11. Amoniaak; NH 3 Ammonia (2 300) ppm Analüsaatori Gasmet DX4000N kasutusjuhend EN 15259:2007-10

Statsionaarsete saasteallikate õhuheitmed 5 (6), 12. Vesinikfluoriidhape; HF (2 100) ppm Hydrogen fluoride 13. Metaan; CH 4 (2 500) ppm Methane 14. Etaan; C 2H 6 (2 100) ppm Ethane 15. Propaan; C 3H 8 (2 100) ppm Propane 16. Etüleen; C 2H 4 (2 100) ppm Ethylene 17. Benzeen; C6H6 Benzene 18. Metüül merkaptaan; CH 3SH Methyl mercaptan (2 100) ppm (2 1000) ppm 19. Dimetüül sulfiid; C 2H 6S (2 1000) ppm Dimethyl sulfide 20. Dimetüül disulfiid; C 2H 6S 2 (2 1000) ppm Dimethyl disulfide 21. Formaldehüüd; CHOH (2 100) ppm Formaldehyde 22. Atsetoon; C 3H 6O Acetone 23. Veeaur Water vapour 24. PM 2,5 / PM 10 ja summaarsete tahkete osakeste kontsentratsiooni mõõtmine suitsugaasides Determination of PM 2,5 / PM 10 and TSP in flue gases and emissions using EMES 3866 25. Gaasilise keskkonna temperatuuri mõõtmine Temperature of gaseous environment 26. Põlemisgaasides summaarsete lenduvate orgaaniliste ühendite masskontsentratsiooni määramine kasutades leek ionisatsioon meetodit (FID) Determination of total gaseous organic carbon in flue gases using continuous flame ionisatsion detector method (FID (2 100) ppm (0,4 40) vol% 1 mg/m 3 100 g/m 3 EVS-EN 13284-1: 2002 VDI 2066 / part 10 (-20 +1150) C EN 15259:2007-10 EVS-EN 60584-1:2013 EVS-EN 60584-3:2008 (0,5 10) mg/m 3 (5 100) mg/m 3 (50 1000) mg/m 3 (500 10000) mg/m 3 EVS-EN 12619:2013 EN 15259:2007-10 Õhuheitmete labor vastab CEN/TS 15675:2007 nõuetele Laboratory has competence according to CEN/TS 15675:2007

6 (6) 2. tamist teostav struktuuriüksus: Part of legal entity that provides testing: TTÜ energiatehnoloogia instituut, kütuse ja õhuemissiooni teadus- ja katselabor Laboratory of Fuel and Air Emission Analysis, Tallinn University of Technology Department of Energy Technology Aadress : Laboratory address: Ehitajate tee 5, Tallinn 19086 3. Labor on akrediteeritud standardi EVS-EN ISO/IEC 17025:2006 nõuete suhtes Laboratory is accredited against the requirements of standard EVS-EN ISO/IEC 17025:2006 Märkus: käesolev lisa asendab 18.05.2017 väljaantud lisa seoses akrediteerimisulatuse täpsustamisega Note: this annex replaces annex issued on 18.05.2017 due to the specification of accreditation scope K. Saarniit K. Tõugu EAK juhataja Peaassessor Director Lead assessor Tallinn, 25.09.2017