PRECISION INVERTER-DRIVEN. We Thought of Everything... And Then Some.

Similar documents
A Design So Smart It's Simple. AIR CONDITIONERS & HEAT PUMPS RUUD. We Thought of Everything... And Then Some.

Ruud Ultra Series Variable Speed Heat Pumps

Rheem Prestige Series Variable Speed Heat Pumps

Efficiency Standards By Region

RUUD AIR HANDLERS & COILS

RHEEM 90%+ GAS FURNACES

Rheem Prestige Series Variable Speed Air Conditioners

Rheem Prestige Series Variable Speed Heat Pumps

RHEEM RESIDENTIAL PACKAGE UNITS

PROVIDING EXTRA-HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

Rheem Prestige Series Variable Speed Air Conditioners

Rheem Prestige Series Variable Speed Heat Pumps

Ruud Ultra Series Variable Speed Air Conditioners

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Rheem Ingenuity. Innovation And Then Some. New Prestige Series High Efficiency Water Heaters

AND WORRY-FREE PERFORMANCE

AND WORRY-FREE PERFORMANCE

Ruud Ultra Series Variable Speed Heat Pumps

PROVIDING HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

XC21. XC21 Air Conditioner Up to 20.5 SEER. Home Comfort Systems. The most quiet and efficient central air conditioner you can buy*

HE PROFESSIONAL S CHOICE

YORK AFFINITY VARIABLE CAPACITY RESIDENTIAL SYSTEMS

INTRODUCING YORK AFFINITY VARIABLE CAPACITY RESIDENTIAL SYSTEMS

A heat pump that redefines comfort and efficiency.

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

complete comfort Heat Pumps

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

COLEMAN ECHELON VARIABLE CAPACITY RESIDENTIAL SYSTEMS

AND WORRY-FREE PERFORMANCE

Rheem Prestige Series EcoNet Enabled Modulating Upflow Gas Furnaces

Rheem Classic Plus Series Two-Stage Air Conditioners

cool and comfortable Air Conditioners

complete comfort Heat Pumps

An air conditioner that redefines comfort and efficiency.

Inverter Ducted Split Air Source Heat Pump. Simply Smart. System with Inverter Drive Technology. boschheatingandcooling.com

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

Infinity 19 Heat Pump with Puron Refrigerant

complete comfort Heat Pumps

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Inverter Ducted Split Air Source Heat Pump System with Inverter Drive Technology

TECHNICAL SPECIFICATIONS

Infinity 16 Heat Pump with Puron Refrigerant

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing

The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models

CHAMPION MOMENTUM VARIABLE CAPACITY RESIDENTIAL SYSTEMS

COLEMAN ECHELON VARIABLE CAPACITY RESIDENTIAL SYSTEMS

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

complete comfort Heat Pumps

The XP21 raises the bar for efficiency and comfort.

Two-Stage Heat Pump with Puron

:: welcome to the rebirth of cool The all-new Rheem Commercial Renaissance Line

XP21 The most quiet and efficient heat pump you can buy*

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Ruud Achiever Plus Series Two-Stage Air Conditioners

Reference Copy READ ONLY

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Rheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER

Xc21 air conditioner up to seer Xc21

The XP17 provides comfort without comparison.

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEMS

Ruud Achiever Series Air Conditioners

Evolution Extreme Heat Pump

RUUD 80% GAS FURNACES

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEMS

Infinity 19 Heat Pump with Puron Refrigerant

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

UILT FOR LIFE. YOURS.

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

Featuring... ASZ16 UP TO 16 SEER. ASZ16 Heat Pump

16.0. High-Efficiency Heat Pump Designed with Your Comfort in Mind. Performance Series Heat Pumps with Puron Refrigerant

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Infinity 20. Heat Pump with Greenspeed Intelligence. Variable-Speed, Ultra High-Efficiency Heat Pump with up to 20.0 SEER and 13.

T-Class AC and HP Units Up to SEER and 9.0 HSPF. Commercial Air Conditioners and Heat Pumps. True performance and rugged durability

DZ20VC HEAT PUMP HIGH-EFFICIENCY, INVERTER TECHNOLOGY UP TO 21 SEER UP TO 10 HSPF VARIABLE-SPEED COMFORTNET COMPATIBLE COMFORT FOR LIFE

ICP Inverter Heat Pump Application Guideline

Residential and Light Commercial Ductless Systems Catalog

TECHNICAL SPECIFICATIONS

Rheem Prestige Series Communicating Two-Stage Variable Speed Multi-Position. Gas Furnaces

The XC17 is an efficiency expert.

Infinity 21 Air Conditioner with Puron Refrigerant

True performance and rugged durability. Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 16.2 SEER

Infinity 18VS. Heat Pump with Variable-Speed Technology. Variable-Speed, High-Efficiency Heat Pump with up to 18.0 SEER and up to 11.

complete comfort Heat Pumps

Come home to perfectly quiet and efficient comfort.

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

:: welcome to the rebirth of cool The all-new Rheem Commercial Renaissance HVAC Line

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

Trane Packaged Systems. Everything comes together perfectly. Read Only

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEMS

Rheem High Efficiency Air Handler

FOR EVERY INDUSTRY. Office. School. Restaurant. Health Care. Retail

incomparably cool XC21 The most quiet and efficient central air conditioner you can buy*

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

PACKAGED DUAL FUEL UNIT ENERGY-EFFICIENT COMPRESSOR. UP TO 14.5 SEER, 8.0 HSPF, 81% AFUE Multi-Position Installation

Goodman 2 Stage Heat Pump Troubleshooting Manual

TRANE XLi HEAT PUMPS THE ALL-SEASON COMFORT OF TRANE. Exceptional heating and cooling all year long READ ONLY

Home Comfort Systems. g60v. The quietest furnace in its class*

Heat Pumps. It feels better every day of the year with READ ONLY

FORCED AIR + HYDRONIC

Water Source Heat Pumps

Transcription:

INVERTER-DRIVEN PRECISION RHEEM PRESTIGE SERIES VARIABLE-SPEED AIR CONDITIONERS & HEAT PUMPS & CLASSIC PLUS THREE-STAGE HEAT PUMPS Classic Plus Series Heat Pumps RP17 Prestige Series Air Conditioners RA20 Prestige Series Heat Pumps RP20 We Thought of Everything... And Then Some. 1

What is 360º+1? For nearly a century, Rheem has been committed to engineering the highestquality, highest-performing, highestefficiency products on the market. Our 360º+1 design philosophy takes Rheem s industry-leading innovation to the next level. We re building advanced 360º Performance, 360º Installability, 360º Serviceability, and 360º Integration into the smallest details of every single product. Then we take it a step further with exclusive PlusOne Advantages designed to make your job easier and your customers experience better than ever before. That s 360º+1. Classic Plus Series Heat Pumps RP17 Prestige Series Air Conditioners RA20 Prestige Series Heat Pumps RP20 Inverter-Driven Solutions from Rheem Led by our innovative Prestige Series models and featuring some of the industry s best efficiencies 1 up to 54% higher for cooling (up to 20 SEER) and 58% higher for heating (up to 13 HSPF on heat pumps) compared to typical designs 2,3 our inverter-driven platform far outpaces singlestage systems, while offering significant benefits over competitive models. For your customers, variable-speed and three-stage inverter-driven technology provides precise, quiet comfort via all-day temperature, humidity, and indoor air quality management enhanced by EcoNet Air + Water Control compatibility. Durable components throughout, including a Copeland Scroll variable-speed compressor, come with a 10-year, limited parts warranty plus a 10-year, conditional unit replacement warranty* for added peace-of-mind. For you, there s exclusive, contractor-friendly features like EcoNet Enabled diagnostics, PlusOne Expanded Valve Space and PlusOne Triple Service Access for faster, easier installation and servicing. And unlike other brands, Rheem s Prestige Series inverter-driven products feature the same high-efficiency ratings across all capacities in a model line 4 so you can give homeowners the right-size unit for their home, without downsizing their energy savings. 1 As compared to SEER ratings for comparable Carrier, Trane, Lennox, York, Goodman, Daikin and Nordyne models ranging between 16 and 25.5 SEER, as of May 2015 2 As compared to standard, 13-SEER-rated air conditioning units 3 As compared to standard, 8.2-HSPF-rated heat pump units *10-year conditional unit replacement on compressor failure; warranty registration required 4 Refers to the full range of 2-, 3-, 4- and 5-ton capacities for Prestige Series models 2

Comfort: Perfectly-Sized for all Conditions 3600 RPM Variable-speed system adjusts speed to meet demand, for always Seasonal, 24-Hour Cooling & Heating Requirements for the Home: Operation "right-sized" performance Winter Variable-Sp Building Lo Single-Sta COOL COLD FRIGID Single-Stage System Variable-speed system adjusts speed to meet demand, for always "right-sized" performance COOL COLD FRIGID COOL COLD FRIGID Winter Single-Stage System 3600 RPM Single-Stage System 3600 RPM Variable-Sp Building Lo Single-Sta Single-Stage System Single-Stage System Variable-speed system adjusts A variable-speed unitspeed adjusts its speed based on current outdoor and indoor conditions, delivering precisely the correct amount of to satisfy the home to meet demand, for always "right-sized" performance Variable-speed system adjusts building load and speed perfectly maintaining the thermostat setpoint. to meet demand, for always "right-sized" performance Savings: Top-of-the-Line Efficiency Single-Stage System A typical variable-speed unit is capable of modulating its capacity to meet building loads under outdoor temperatures as low as 70 F in heating mode to as high as 107 F in cooling mode. While modulating, these systems can achieve up to 39 EER 2.4 times the energy efficiency of a single-stage unit under the same conditions. Because inverter-driven solutions operate more efficiently, they perform better AND save on energy costs. Annual Energy Cost Savings for Rheem Heat Pumps: 6.8-HSPF Baseline* 4-Ton 2-Ton 5-Ton 3-Ton 4-Ton 5-Ton Annual Energy Cost Savings for Rheem Air Conditioners: 2-Ton 3-Ton Unit Capacity Unit Capacity 10-SEER Baseline* 900 400 400 900 800 372 223 200 149 100 700 298 600 500 Savings (USD) 200 300 Savings (USD) Savings (USD) 300 298 223 400 149 300 228 200 100 100 0 600 816 680 680 547 547 500 456 400 319 300 476 340 476 456 340 319 2-Ton 3-Ton http://bit.ly/energystar-heatpumps Air Conditioners: 0 10.06.8 (Baseline)13.0 10.0 HSPF HSPF 4-Ton For more information on operating costs and payback schedules, please visit the EPA s ENERGY STAR websites: Heat Pumps: 228 200 100 0 0 10.0 (Baseline) 20.0 10.0 (Baseline) 20.0 6.8 (Baseline) SEER SEER Unit Capacity 816 800 372 700 13.0 http://bit.ly/energystar-airconditioners 5-Ton 900 816 * Most commonly replaced system. Energy savings shown are calculated per AHRI (Air-Conditioning, Heating, and Refrigeration 800 400 Institute) annual operating costs and represent372 directional numbers most applicable to typical cooling and heating requirements 680 700 within the mid-latitudes of the U.S. 298 300 223 200 ngs (USD) s (USD) Winter 3600 RPM Savings (USD) COOL COLD FRIGID MILD WARM HOT Variable-speed system adjusts speed to meet demand, for always "right-sized" performance Variable-speed system adjusts speed to meet demand, for always 12:00 PM "right-sized" performance 3600 RPM 3600 RPM MILD WARM HOT MILD WARM HOT Summer Summer MILD WARM HOT Summer 600 500 400 547 456 476 3

Improved Built-in Indoor Air Quality Because of longer runtimes, inverter-driven technology allows for improved filtering and cycling of clean air, and controls humidity, resulting in better comfort and indoor air quality overall. Summer Cooling Load Profile: Relative Humidity Relative Humidity MUGGY COMFORTABLE 12:00 a.m. 6:00 a.m. 12:00 p.m. 6:00 p.m. 11:00 p.m. Time of Day Single-stage setpoint control Two-stage setpoint control Variable-speed setpoint control Setpoint Single-stage systems (represented by the orange line graph) can only operate at one speed, and are either on or off. When the system is off, humidity levels can increase because no moisture is being removed from the home in the off cycle. This means these systems struggle to first reach a humidity setpoint (represented by the gray dashed line) and then maintain that point as conditions change throughout the day. While better than single-stage systems due to their ability to operate at two on speeds (in addition to off), two-stage systems (red line) are not able to achieve the precision of variable-speed systems (navy line). Because they operate using a longer, more efficient on cycle constantly adjusting their performance to match surrounding conditions variable-speed systems are able to quickly reach and then consistently maintain a humidity setpoint. Superior comfort and efficiency, plus all the Performance, Installability, and Serviceability you expect from Rheem. 4

Rheem Products Featuring Inverter-Driven Technology Two-Stage Cooling from Rheem RP20 RP17 RA20 RA17 NOMINAL SIZES 2-, 3-, 4- & 5-ton models 2-, 3-, 4- & 5-ton models 2-, 3-, 4- & 5-ton models 2-, 3-, 4- & 5-ton models HSPF RATING Up to 13 HSPF Up to 11 HSPF SEER RATING Up to 20 SEER 17 SEER across all capacities Up to 20 SEER Up to 17 SEER MOTOR TYPE ECM Motor Standard PSC Motor (single-speed) ECM Motor Standard PSC Motor (single-speed) VALVE TYPE Indoor/Outdoor EEV (Electronic Expansion Valve) Indoor/Outdoor EEV (Electronic Expansion Valve) Indoor EEV (Electronic Expansion Valve) Indoor EEV (Electronic Expansion Valve) COMPRESSOR TYPE Copeland Scroll variable-speed compressor Copeland Scroll variable-speed compressor Copeland Scroll variable-speed compressor Copeland Scroll UltraTech compressor AVAILABLE SPEEDS Variable speeds from 1200 RPM to 7000 RPM 3 speeds: low, medium, high Variable speeds from 1800 RPM to 7000 RPM 2 speeds: medium, high RHEEM LIMITED WARRANTY 10-year conditional unit replacement warranty; 10-year limited parts warranty* 10-year conditional unit replacement warranty; 10-year limited parts warranty* 10-year conditional unit replacement warranty; 10-year limited parts warranty* 10-year conditional unit replacement warranty; 10-year limited parts warranty* ECONET COMPATIBILITY EcoNet Enabled** EcoNet Enabled** EcoNet Enabled** EcoNet Enabled** SYSTEM COMPATIBLE AIR HANDLERS Enabled RHMV (variablespeed) air handler Enabled RH2T (2-speed) and RHMV (variablespeed) air handlers Enabled RHMV (variablespeed) air handler Enabled RH2T (2-speed) and RHMV air handlers SYSTEM COMPATIBLE GAS FURNACES Enabled R802V furnace or R97V/R96V furnace/rcf coil with EEV when dual-fuel system is required Enabled R802V furnace or R97V/R96V furnace/rcf coil with EEV when dual-fuel system is required Enabled R802V furnace or R97V/R96V furnaces/rcf coil with EEV Enabled R802V furnace or R97V/R96V furnace/rcf coil with EEV *Refer to the full Limited Warranty Certificate for complete details. Conditional warranties require registration. **Purchase and installation of EcoNet WiFi Kit and EcoNet Control Center required. WiFi broadband Internet connection required. Must be paired with EcoNet Enabled furnace or air handler. 5

Inverter-Driven Technology EcoNet Enabled, Inverter-Driven Rheem Prestige Series Heat Pumps and Air Conditioners, and Classic Plus Series Three-Stage Heat Pumps, are able to operate at a wide range of speeds in order to precisely adapt their cooling capacities (and, in the case of heat pumps, heating capacities as well) to current conditions and demands. How It Works 10 1 6 The EcoNet Enabled, inverter-driven Rheem Prestige Series Variable Speed Heat Pump (1) incorporates a outdoor unit control (VSODU) (2) that continuously monitors the EcoNet control center s (3) temperature and humidity set point, suction pressure (4), suction temperature (5), outdoor coil temperature (6) and outdoor temperature (7) and feeds this information to the Inverter Control Motor Drive (8). The Inverter Control Motor Drive is electrically protected by the low pass filter (9) that only permits the passage of a 60-hertz signal to the Inverter Control Motor Drive, the Choke (10) that absorbs power spikes that could occur, and the Ferrite Rings (11) that prevent electrical noise. The Inverter Control Motor Drive converts AC to DC power, sends it to the Copeland Scroll variable-speed compressor (12) Brushless Permanent Magnet Motor (BPM), dynamically adjusting its speed. The Copeland Scroll variable-speed compressor is protected by a Suction Accumulator (13), preventing liquid refrigerant from entering the compressor. Simultaneously the VSODU control transmits the electrical input to the ECM outdoor fan motor, (14) which is equipped with the latest swept wing fan technology (15) and the Electronic Expansion Valve (EEV), (16) which syncs up with the compressor speed to deliver the exact capacity the home needs to meet its comfort requirements. The result of this advanced technology is significantly improved energy efficiency and comfort. 7 9 2 8 11 19 12 5 16 18 6

14 15 4 13 The New Composite Base Pan (17) dampens sound, captures louver panels, eliminates corrosion, and reduces number of fasteners needed. PlusOne Expanded Valve Space 3"-4" and -5" service valve space (18) provides a minimum working area of 27-square-inches for easier access. PlusOne Triple Service Access 15"-wide, industry-leading corner service access (19) makes repairs easier and faster. The two-fastener removable corner allows optimal access to internal unit components. Individual louver panels come out once fastener is removed for faster coil cleaning and easier cabinet reassembly. PlusOne Energy Efficiency offers minimum of 20-SEER and 13-HSPF system performance across all capacities. EcoNet (3) is an innovative technology exclusively from Rheem that will allow monitoring and control of Rheem air conditioning, heating and water heating systems all from a single access point, whether customers are home or away. This will allow products that feature EcoNet technology to work together to ensure optimal performance and energy efficiencies in the home. 3 17 7

H E A T I N G C O O L I N G + W A T E R H E A T I N G Why Rheem? Relationship, Dedication and Innovation Rheem makes customers our first priority. Our approach as a company is to keep the dialogue ongoing and to listen. Then act. The innovations we ve developed throughout the years in both the HVAC and water heating industries are a direct result of that process. And we have a long list of industry firsts to show for it, with more to come. Rheem is dedicated to providing the products your customers need and the opportunities you want to expand your offerings and increase profitability. That s the Rheem 360 +1 approach to partnership. Learn more at MyRheem.com/360 In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. www.myrheem.com Rheem Heating, Cooling & Water Heating P.O. Box 17010 Fort Smith, Arkansas, 72917 Rheem Canada Ltd./Ltée 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 05P Printed in the U.S.A. 12/15 WP Form No. M11-1912 8