Se vuoi ricevere aggiornamenti e novità compila i tuoi dati - In attesa di iniziare

Similar documents
Instrumentation Products and Applications

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Siemens Process Automation End-user Summit- 2011

Product Information to the manual

WAGO-I/O-SYSTEM 750 Explosion Protection via Intrinsic Safety

Basics of Safety Applications

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

The Next Generation Machine Protection System

Basics of Safety Applications

SAFEMASTER PRO. The configurable safety system versatile and extendable. Our experience. Your safety.

Fire and Gas Monitoring Panel ST7-HV

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

SUPREMATouch. Modular Fire & Gas Detection System

Temperature Measurement

Symphony Plus Combustion instruments

SUPREMATouch. Modular Fire & Gas Detection System

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

operational excellence Solutions for

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018

Speed and Frequency Seite 1 von 7

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

Safe area; Zone 1 and Zone 2

SIFLOW FC070 Coriolis mass flow transmitter As easy to install as playing a CD. siflow

For Complete Fire and Gas Solutions

Temperature Measurement Transmitters for field mounting

Connection of CET4-AP to Siemens ET 200S

SIL2-Interface/ -Signal Conditioners Series DuoTec

SITRANS T temperature transmitters A broad product family for every application. sitrans

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

Partners in Process Automation with Emerson Process Management for Intrinsic Safety

TYPE APPROVAL CERTIFICATE

ASIsafe Solution PROFIsafe

Gas Turbine Flame Monitoring

Fire control panel detect 3004 plus and accessories

APPLICATION DATA SHEET

Rosemount 3051CFC Compact Flowmeter

Fire control panels FC726 FC726-XA

Dräger Polytron 7000 Fixed gas detector

explosion protection automation global partner of the process industry

Building system automation. How to use

Temperature measurement with SITRANS T siemens.com/processinstrumentation

Smarter Field Instrumentation Life Cycle Management. Ray Rogowski Global Marketing PMC Instruments

Power & Instrumentation BU

Assembly. Host Sub-D Alarm

Dräger Polytron 8100 EC Detection of toxic gases and vapors

RS485 MODBUS Module 8AI

Fire alarm system EBL512 G3

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

INTERFACE AND SYSTEM SOLUTIONS. Explosion protection for automation

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

Gas Controller Module GC-06

Transmitter Series. Intelligent Transmitter Series Tailor the Measurement to Your Needs INGOLD

Fuji Electric s Approach to Machinery Safety and Functional Safety -Total Safety-

Process Safety - Market Requirements. V.P.Raman Mott MacDonald Pvt. Ltd.

SUPREMATouch Modular Fire & Gas Detection System

APPLICATION DATA SHEET

Dräger Polytron 7000 Detection of toxic gases and oxygen

Operating Instructions Edition 02/2007

Protect your Investment with Safety Manager R160 and Integrated Fire and Solutions

Touchpoint Pro Flexible Gas Control System

Emissions monitoring solutions

designed for rail 5000 Series

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

Industrial Grade Gas Detection Detecting The Difference

Functional Safety Manual June pointek CLS500/LC500

Products and performance

Danfoss gas detection Controller unit

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

On the job around the clock 24/7: Fire detection systems

Application Guideline. FOUNDATION TM fieldbus for LEPIU. Prepared by: Thomas Klatt Business Development Manager

FC723 Fire control panel

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Tank protection example using Simatic

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

Safety in the process industry

Protect your investment with Safety Manager

IGD.CO.UK

HAUBER-Elektronik. Product overview. Condition monitoring Mechanical protection in compliance with DIN ISO 10816

IEC61511 Standard Overview

Level gauges Series LS Level indicator, switch and transmitter for liquids

PROCESS AUTOMATION APPLICATION AND SELECTION GUIDELINE FIELDCONNEX FIELDBUS INFRASTRUCTURE

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Temperature Solutions Line Card

INTERFACE PRODUCTS SYSTEMS AND SOLUTIONS

Wind power Condition Monitoring. Condition Monitoring Systems (CMS) in wind turbines CMS. Authors: Martin Kluge Michael Danitschek

Dräger REGARD 3900 Series Control System

Trusted fault tolerant technology

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Elemec3. Networked Public Address and General Alarm System (PA/GA)

Intelligent sensing for every temperature and condition

your dust explosion protection experts

YOUR PARTNER IN FIRE & GAS DETECTION

Protective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.

MODEL 9010/9020 LCD CONTROL UNIT

, CFSE, Senior Manager, ABB Taiwan;, 2011/9/2. Functional Safety. ABB Group September 5, 2011 Slide 1

SITRANS F C MASSFLO Flow metering based on coriolis technology. sitrans f

Transcription:

Se vuoi ricevere aggiornamenti e novità compila i tuoi dati - In attesa di iniziare Inserisci i tuoi dati Cliccando qui Compila i dati

Safety Integrated in SIMATIC PCS 7 In attesa di inizare Verificate se l audio è attivo Disattivate il microfono e la webcam. Ponete delle domande scrivendo nell apposita sezione. Il relatore risponderà a fine presentazione. I vostri suggerimenti sono graditi! Per dare feedback e proporre eventuali argomenti scrivete a simatic.enews.it@siemens.com Per maggiori informazioni: www.siemens.it\simatic-live

Safety Integrated in SIMATIC PCS 7 Soluzioni a sicurezza intrinseca per applicazioni safety in PCS 7

Industries with Intrinsic Safety Requirements

Intrinsic Safety Hazardous Areas and Classification

Installation in Hazardous Areas There is a differentiation between gas and dust areas FM/UL differentiates Class I for gas and Class II for dust The Zone new 2, Zone SIMATIC 1 and Zone 0 solution for Atex hazardous area and fail safe functions Differentiates Zone 2, Zone 1 and Zone 0 for gas in SIMATIC PCS 7 Differentiates Zone 22, Zone 21 and Zone 20 for dust Field devices are available for all Zones SIMATIC Remote I/O is usually for the ET installation 200iSP in Zone 2 (22) F What is about intrinsically safe installation in Zone 1 and 21?

Safety Integrated in SIMATIC PCS 7 SIMATIC ET 200iSP F

Product Overview The first Remote I/O for hazardous areas and safety loops SIL 3

Field installation SIMATIC ET 200iSP is the new standard for distributed I/O in hazardous areas gas and dust Can be mounted directly in zone 1 or 2, zone 21 or 22 and in non hazardous areas Connected sensors and actuators can be located in Zone 0 or 20 Branch Process technique, chemical- and pharmaceutical industry, paint shops, gas turbines, drilling platforms, mills (coal, grain,... ), mines,

Advantages of Fail-Safe Remote I/O in Ex zone Problem-free connection of existing field devices Less wiring No need for marshalling distributors, cable racks, etc. Time saving due to reduced wiring No additional mechanical protection is needed to achieve the Exprotection class High flexibility: quick and easy expansion Low engineering overhead Optimal diagnosis capabilities Cost saving over the complete life-cycle Optimized connection of valves

Fieldbus Isolating Transformer Product name: SIMATIC RS 485-IS Coupler Transforms PROFIBUS DP into intrinsically safe PROFIBUS DP (PROFIBUS RS 485-iS) Enables utilization up to zone 1: from intrinsically safe DP-devices (e.g. ET 200iSP) as repeater installation in zone 2 Order Number 6ES7 972-0AC80-0XA0

Key Features Integrated Diagnostics Intrinsically safe Installation up to Zone 1 Operation Temperature -25 up to 70 C Optimal integration in PCS 7 and others (diagnostic, ) HARTtransparent Intrinsically safe and failsafe Hot swapping + Configuration in Run Redundancy

Modular Modular Individual configuration of the ET 200iSP-station Designed for future expandability Expandable up to 32 modules per ET 200iSP-station Easy software configuration Maximal availability of process due to bit-modularity Diagnostic information from each module and channel More cost effective with mixed module configurations

Fixed Wiring Fixed wiring Cost effect cabinet building Easy to use multi-connector technology Rapid wiring checking without damaging electronic components Reduced installation time due to pre-wired terminal modules Hot Swapping - module replacement during operation Improved availability due to rapid module exchange without tools Safe module swapping with automatic mechanical coding

Fast Installation Snap power supply and PROFIBUS interface terminal modules onto S7-300 DIN rail Snap on terminal modules for the desired number of electronic modules, and push them next to the power supply and PROFIBUS interface terminal modules Now snap on the actual power supply, PROFIBUS interface and electronic modules Finished!

Optimal integration Integration in PCS 7 (and in STEP 7) and other control systems CFC-driver integrated in PCS 7 Parameterise all station features with: PCS 7 V7.1 SP3 PDM Communication set-up with PCS 7/STEP 7 Producer and user information is saved in the module PROFIBUS based #1 field bus world wide DPV1-Integration

Diagnostics Fault diagnosis Extensive diagnostic information channel slot module System diagnostic information for internal/external failures Pass through of status, warning and other information from HART-devices to process control system CFC-drivers for diagnostics in SIMATIC PCS 7 included Producer and user information are saved in the module

Installation Line Monitoring and Safety Standard installation without ET 200iSP F Line Monitoring Zone 2 Sensor Barrier AI Communication CPU Communication DO Barrier Actuator PFD SYS = PFD S +PFD L +PFD FE PFD S = PFD Sensor +PFD Barrier PFD L = PFD AI +PFD CPU +PFD DO +PFD Com PFD FE = PFD Barrier + PFD Actuator

Installation Line Monitoring and Safety Installation with ET 200iSP F Line Monitoring Sensor AI Communication CPU Communication DO Actuator Zone 2 Zone 0 Zone 1 Zone 1 Zone 0 PFD SYS = PFD S +PFD L +PFD FE PFD S = PFD Sensor PFD L = PFD AI +PFD CPU +PFD DO +PFD Com PFD FE = PFD Actuator

Redundancy for Higher Availability and Reliability Power Supply Redundant or single power supply Independent on the communication interfaces Communication Using standard PROFIBUS PROFISafe for safety Redundant or single FMR FMR (Flexible Modular Redundancy) is fully supported Use Redundancy only where required No specific and additional communication cables

Redundancy on the IO - Level Increased availability and reliability Due redundant IO channels with redundant sensors Separate modules are recommended Separate modules and sensors are the key for higher availability and reliability Voting in CPU With CFC blocks

SIMATIC PCS 7 Totally Integrated Automation Standard and seamless integration in PCS 7 (and in STEP 7)

Parameterization with PDM integrated in PCS 7 Easy parameterization with PDM for HART-Devices for ET 200iSP connected to non Simatic Master Systems for ET 200iSP in former versions of PCS 7

Diagnostics PCS 7 Maintenance Station Diagnostic information about Power Supply Interface Module IO Module Short circuit and wire break

Failsafe IO Modules Digital Input Module F-DI8 NAMUR, 6ES7138-7FN00-0AB0 Digital Ouput Module F-DO4, 17,4V DC 40mA, 6ES7138-7FD00-0AB0 Analogue Input Module F-AI4 HART, 6ES7138-7FA00-0AB0

Failsafe IO Modules Failsafe Modules for installation up to Ex-Zone 1 / 21; up to SIL 3 Digital Input Modul 8 F-DI NAMUR Digital Output Modul 4 F DO Analog Input Modul 4 F-AI HART Line monitoring in Ex area up to the sensor / actuator Benefit in terms of SIL-Calculation, because of integrated Ex-Barrieres Mixed installation with standard modules (on standard TM ) Complete portfolio Failsafe modules for direct Zone 1 installation First in World, failsafe peripherie for installation in Ex-Zone 1 / 21 up to SIL3

F-DI8 NAMUR Digital Input Module F-DI8 NAMUR 8 channel NAMUR (up to 8 x 1oo1 or 4 x 1oo2) Pulse Stretching Increase the length of the pulse to a defined time Discrepancy check between two channels with sensor type changeover contact Time stamp function FW update via Engineering System Diagnostic / Line Monitoring Short Circuit Wire Break Flutter monitoring

F-DO4 17,4V DC 40mA Digital Ouput Module F-DO4, 17,4V DC 40mA Applicable for intrinsically safe actuators, solenoid valve, DC relay Max. output current 80 ma due parallel connection of the actuator Short circuit, overload and wire break diagnostics Diagnostics LEDs Internal diagnostics buffer Identification data I&M FW update via Engineering

F-AI4 HART Analogue Input Module F-AI4 HART Applicable for intrinsically safe failsafe transmitter HART functionality 4 channels for input ranges 0...20 ma/4...20 ma or 4...20mA with HART Monitoring of overflow and underflow Short circuit and wire break diagnostics Internal diagnostics buffer FW update via Engineering

Accessories

Thank you for your attention! Nicola Iovine PCS 7 Technical Consultant I IA AS PCS 7 E-Mail: nicola.iovine@siemens.com