Adtemp TM 427 TempleTouch TM Thermometer USE, CARE & MAINTENANCE

Similar documents
Adtemp TM ULTRA 417 Digital Fever Thermometer USE, CARE & MAINTENANCE

Adtemp TM II 412 Digital Fever Thermometer USE, CARE & MAINTENANCE

Adtemp TM V 418N Digital Fever Thermometer USE, CARE & MAINTENANCE

Instructions. Consumer Info-Line

Forehead Infrared Thermometer

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION

User Manual. Non-contact Infrared Thermometer.

By cmlam at 2:33 pm, Dec 12, 2017

Non-Touch Thermometer. User Manual. ARC Devices Ltd.

SensorTouch TEMPLE THERMOMETER FAST & EASY GUARANTEED ACCURACY HF370/HF375. Gentle stroke of forehead measures temperature

No Touch Thermometer

Kinsa Smart Ear ThermometerTM Instructions For Use

Insta-ThermTM. All-in-One Thermometer. Instructions. Ear Forehead Ambient Room Temperature

CLETEF-786. Infrared Thermometer Instruction Manual

NON-TOUCH THERMOMETER User Manual

KNOW YOUR ELEKTRA HEALTH THERMOMETER. ON / OFF Button

CareTemp Touch Free Thermometer. Directions for use

Forehead Thermometer Instruction Manual

La Crosse Technology WT-8002U. Digital Clock with Indoor Temperature

Thermometer with Wired Sensor

Indoor/Outdoor Temperature Alert

BIG DISPLAY ALARM CLOCK USER MANUAL

(Place Logo from Lab here)

Digital Refrigerator/Freezer Thermometer model 00986

Digital Cooking Thermometer models / 00282

Thermometer with Probe model 00891A

SC Installation, Operation & Application Guide

Thermometer model 02059

Health & Safety Kit. Digital Bath and Room Thermometer FlexiSafe Fever Alarm Thermometer Nasal Decongester

Local air conditioner

Components of the device. Appearance of the device. ihealth thermometer User s manual LED screen. Manufacturer info. LED screen.

SpotOn Temperature Monitoring System. SpotOn. Temperature Monitoring System. Model 370 Installation and Service Manual

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

Portable Air-conditioner Use and Care Manual

100 Ft. LASER DISTANCE METER

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

Portable Air-conditioner

IMPORTANT SAFEGUARDS IMPORTANT INSTRUCTIONS PRECISION HEAT TM DIGITAL HEATER FAN READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

ELECTRIC FIREPLACE OWNER S MANUAL

TRANQUILITY ADVANCED HEATING SYSTEM

INSTRUCTIONS FOR. Wireless Refrigerator Freezer Thermometer (#10378)

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

Personal Security Glass Vibration Alarm User Manual. Do not use in wet locations

WS-9023U 915 MHz Wireless Weather Station. Instruction Manual

WARNING Important Safety Information

Meat Thermometer with Wireless Display model 01185

Users Manual. Air Velocity Meter

Dual Channels - TENS Electronic Pulse Massager Unit Model No.: MT-5180

Humidity Monitor model 01080

Personal Security. Water Leak Alarm. User s Manual

RECHARGEABLE CLIPPER LI ION RECHARGEABLE CLIPPER INSTRUCTIONS

Alice. In Wall Recessed Electric Fireplace Model Number: (EF172B, EF173B, EF174B, EF175B, EF176B) OWNER S MANUAL

WS-8300U 915 MHz Wireless Weather Station Instruction Manual

Line Voltage Non- Programmable Thermostat Installation Instructions & User Guide

Contents. English. French. Spanish

u Do not use the appliance if any part is damaged or defective. u Do not short battery terminals. u Do not charge batteries.

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

Rechargeable Trimmer. Rechargeable Trimmer Instructions

FEATURES AND SPECIFICATIONS

USER MANUAL. heart rate monitor. measure your heart rate for a better, healthier you! JoinWeGo.com

Reverse Cycle Split System Air Conditioner

USER MANUAL Digital CO Monitor Model CO30

Alice In Wall Recessed Electric Fireplace

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

WS-9117U-IT Wireless 915 MHz Temperature Station. Instruction Manual

WARNING Important Safety Information

User Manual. 40 Tower Fan MODEL: WFTR40W

TIF9055 Programmable. Owner s Manual Manual del Propietario Manuel du propriétaire Benutzerhandbuch Manuale del proprietario

MODEL# GSI180 FRUIT DESSERT MAKER HEALTHY DESSERTS. PHOTO OF PRODUCT

USER'S GUIDE 15E5 SERIES V

Wireless Humidity/ Temperature Monitor Remote Wireless Sensor

IMPORTANT SAFEGUARDS IMPORTANT INSTRUCTIONS DIGITAL LOW PROFILE HEATER READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Dual-Mode Infrared Thermometer Instruction Manual

HI COD REACTOR and Test Tube Heater 2008 Series

Model: 1001T/LCD-A INSTALLATION AND OPERATING INSTRUCTIONS

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

1600 Watt Professional

Comfort System T-21-P Touchscreen Thermostat Installation Manual

WARNING Important Safety Information

HANDHELD FABRIC STEAMER.

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

Forehead Thermometer Instruction manual

BIONAIRE HEATER. Instruction Leaflet. pure indoor living MODEL: BCH4130. Read instructions before operating. Retain for future reference.

portable induction cooktop Instruction Booklet Model ID1350

AlcoBlow. User Handbook

Ultrasonic Humidifier

Service Centers: Conair Consumer Products Inc. 156 Parkshore Drive. Brampton, Ontario L6T 5M1

WIRELESS THERMO-HYGROMETER Instructions manual Cat. No. WS9070IT+

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

Time Now Corporation. Invisible Clock - General Information. Alarm Switch. Timing Functions - Your Invisible Clock has four timing modes

Smart Temp. ApolloP/n Installation Manual. Version 1.0

English. Instruction and operation manual S 530. Leak detector for pneumatic systems

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

English. Instruction and operation manual S 530. Leak detector for pneumatic systems

BBQ THERMOMETER DESCRIPTION OF PARTS. MODEL NO.: AW129/AWR129 Instruction Manual

GHC Thermee Non-Contact Forehead Thermometer Instruction manual V2.5

Transcription:

Adtemp TM 427 TempleTouch TM Thermometer USE, CARE & MAINTENANCE

Intended Use: A Temple Touch thermometer is a device which enables accurate body temperature measurements obtained by using a unique probe, which measures the heat flow from the blood vessels to the skin and converts it to body temperature from the temple area in approximately 6-8 seconds. Safety Information: High, prolonged fever requires immediate medical attention, especially for young children. Do not allow children to take their temperatures unattended. Read the enclosed instructions carefully to ensure accurate temperature readings. Temperature readings are affected by many factors including exercise, drinking hot or cold beverages prior to taking a reading as well as technique. WARNING: Keep batteries out of children s reach. Swallowing a battery could be harmful. Batteries should not be recharged or placed into extreme heat as they may explode. WARNING: It is recommended to remove the batteries from the thermometer when it is not used for a long period. Do not dispose of batteries in fire, recharge, put in backwards, disassemble, mix with used or other battery types they may explode or leak and cause injury. Waste batteries should be deposited in a batteries recycling trash only. WARNING: This product may contain a chemical known to the state of california to cause cancer, birth defects, or other reproductive harm. CAUTION: Do not drop the thermometer or expose to heavy shock. CAUTION: Do not immerse thermometer in water or any other liquid. CAUTION: Do not store the unit in direct sunlight, at a high temperature, in high humidity or dust. CAUTION: Stop using the thermometer if it operates erratically or if display malfunctions. CAUTION: Clean the thermometer probe before storing. CAUTION: Do not attempt to disassemble the unit except to replace the batteries. CAUTION: Do not autoclave. Please note the cleaning procedures described in this manual 2

Quick Start: 1. Press and release the MULTI-FUNC- TION button. 2. Wait 2 seconds. 3. Hold firmly to temple, wait for beep. 4. Read results. 5. Before re-measuring: wait at least 1 minute. Measuring Guidelines: 1. Measurement body location is the temple, in proximity to the temporal artery, between the end of the eyebrow and hairline. 2. Do not place the thermometer on scarred tissue compromised by skin disorder, open sores or abrasions and patients in trauma. 3. Temperature readings are affected by many factors including exercise and drinking hot or cold beverages prior to taking a reading. 4. Consult your physician when using drug therapies that may raise the local skin temperature in the forehead; this may lead to an incorrect reading. 5. Do not place the thermometer on skin exposed to direct sunlight, fireplace heat, air conditioner flow and cold/warm compress therapies. 6. Wait at least one minute between consecutive measurements for the unit to readjust to room temperature. 7. If the thermometer has been stored at a cold temperature, allow the unit to warm naturally to room temperature before using. 8. Performance may be degraded if operated or stored outside stated temperature/humidity ranges. Taking Temperature: Use this thermometer on a clean dry forehead. Wipe away any perspiration, move hair aside from the temporal area and apply the probe to bare skin. 1. Press and release the Multi-Function button, all segments will be displayed along with a single audible beep (Figure 1). 2. The previous result will be displayed for 2 seconds (Figure 2). 3. Wait for the hourglass icon to disappear (Figure 3). Do not try to take a measurement before the hourglass icon disappears, as this may compromise the results. 3

4. Place the thermometer's probe in the center of the temple area between the end of the eyebrow and the hairline. Gently press and hold it against the temple to ensure good contact with the skin is maintained (Figures 4a + 4b). Correct placement and good contact with the skin ensure reliable readings. 5. As soon as the thermometer is in place, the measurement will start automatically. A running circle will appear indicating that the measurement is progressing successfully (Figure 5). Make sure that the thermometer and the patient do not move while measurement is in progress. 6. A temperature reading will be displayed within 6-8 seconds. One long beep will be heard to indicate that measurement is complete and temperature will be displayed for about 1 minute. 7. Press and release the Multi-Function button to turn the thermometer off, or it will shut off automatically after 1 minute. If you need to take another reading wait at least a minute after turning the thermometer off and begin again. If you take a measurement before 1 minute has elapsed, the device will perform a 10 to 0 countdown to allow the device to re-adjust. DO NOT TRY TO MEASURE DURING THE COUNTDOWN. If you attempt to do so, the device will display the previous result, beep 8 times and turn itself off automatically. Setting the Operating Scale F or C The device setting is by default fahrenheit ( F). To change the scale to C, or back to F: 1. While off, press and hold the Multi-function button for 5 seconds, on the screen you will see the icon ( F, C) changes. 2. Release the button, the hourglass icon will disappear in 5 seconds indicating that the device is ready for use. 4

Changing the battery: To install/replace, first switch off the device. Remove the battery cover by sliding it out of its housing. Firmly attach the batteries to their place, making sure polarity is correct. (see engraving on the bottom of battery compartment). Slide the battery cover back into place. Troubleshooting and special indications: The thermometer has been designed to display feedback-warnings to ensure proper usage and accurate temperature measurement. When an error appears, the device will "beep" 5 times, and then the thermometer will turn off automatically. In the event of a malfunction or incorrect temperature measurement, the following warnings will be displayed: HI: If the measured temperature is above 107.6 F (42 C) the device will beep and display HI. Remedy: Turn the unit OFF, wait 1 minute and then ON again. Retake temperature using proper technique. If still reads HI, this indicates that the patient has a high fever. Seek immediate medical attention. NOTE: This is not a device malfunction. LO: If the measured temperature is below 95 F (35 C) the device will beep and display LO. Remedy: Turn the unit OFF, wait 1 minute and then ON again. Retake temperature using proper technique. If still reads LO, this indicates that the patient has a low body temperature. NOTE: This is not a device malfunction. Er.1: If the thermometer is too cold or too hot to operate. The device will beep 5 times and display Er.1 Remedy: 1. Verify room temperature within product range 60.8 F- 104 F (16 C - 40 C). 2. Wait 1 minute and then retake temperature using proper technique. 5

Er.2: If the temperature did not register because of poor contact, patient movement or poor placement, the device will beep 5 times and display Er.2 Remedy: Turn the unit OFF, wait 1 minute, turn it ON again and retake temperature using proper technique. Er.3: If the unit malfunctioned, the device will beep 5 times and display Er.3 Remedy: Do not use the thermometer Call 1-800-232-2670 for service. Low Battery: Battery icon is on continuously. Remedy: The battery has enough remaining life for approximately 10 more measurements Drained Battery: Battery icon appears as unit is turned on and the device turns itself OFF. Remedy: Replace battery. Standards: Complies with EN 12470-3 and ASTEM E 1112-00 How to care for this product: Wipe the tip and probe with a cotton swab moistened with 70% isopropyl alcohol before & after each use. After cleaning, wait at least 2 minutes before taking a measurement for the unit to re-adjust to room temperature. Use only a soft dry cloth to clean the body of the thermometer (if necessary). Never use an abrasive cleanser or submerge the thermometer in water or other liquids. 6

Specifications Feature Performance / Data: Measurement location: Measurement range: Operation environment: Storage environment: Measurement readout: Accuracy: Display: Battery: Battery life: Weight: Dimensions: Memory: Auto shut off: Case material: Probe material: Warranty: Measurement time 6-8 seconds Temple area of the forehead 95 F to 107.6 F (35 C to 42 C) 60.8 F-104 F (16 C - 40 C) Humidity: 15-95% (non condensing) -4 F to 122 F (-20 C - 50 C) Humidity: 15-95% (non condensing) Celsius or Fahrenheit Complies with ASTM E 1112-00 standard requirements TN LCD 0.63" X 0.44" (16 mm X 11 mm) 2 AAA 1.5volt batteries Minimum 1000 full duty cycles over 24 month period 1.3oz (37gr) including batteries 4.7" x 1.17" x 1" (12 cm x 3.0 cm x 2.4 cm ) Last reading display when turned on After 60 seconds Medical grade ABS plastic Medical grade Stainless steel, medical grade ABS plastic 2 year 7

Parts and Assembly Non-invasive sensor Display Window Multi-Function Button WARRANTY This Thermometer is guaranteed for a period of 24 months from date of purchase. This warranty does not cover batteries, or damage resulting from improper handling or use. Specific legal rights stipulated in your state may guide this warranty. If you have a legitimate claim under this warranty, send item(s) postage paid to Service Center, Attn: Repair Dept., 55 Commerce Dr., Hauppauge, NY 11788. Please include your name and address, phone no., proof of purchase, and a brief note explaining the problem, your return address and $2.00 to cover shipping and handling. 8

To register your product visit us at www.adctoday.com/register This manual is available online in a variety of languages, follow the links for language options. www.adctoday.com/care Grand Bond Electronics Ltd Room 2208 22/F CCT Telecom Bldg. 11-19 Wo Shing Street Fotan, New Territories, Shatin Hong Kong Medes Limited 5 Beaumont Gate Shenley Hill, Radlett Hertfordshire, WD7 7AR United Kingdom Distributed by: ADC 55 Commerce Drive Hauppauge NY 11788 Made in China www.adctoday.com Patent # 7597668 IB p/n 93-427-00 rev 4 0086 Printed in China