TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

Similar documents
USER MANUAL CEF AP28 CONTROL PANEL

Racal-Guardall. Countess. User Instructions. Countess

TS700. Intruder Alarm Control Panel OPEN ENT 0 ESC

Intruder alarm system Operating Instructions

SECURIT 700L USER MANUAL

SECURIT 703 USER MANUAL

PYRONIX LIMITED, Pyronix House, Braithwell Way, Hellaby Rotherham South Yorkshire S66 8QY England

Intruder alarm system Operating Instructions

Manager Guide. Indications on the system. Using System. Indications

TS2500. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT ESC. Setting the System. Unsetting the System RE SET

THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels

TS700. Intruder Alarm Control Panel ENT 0 ESC

Accenta/Optima. User Guide. UK Security Panels. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number:

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

HARDWIRED CONTROL PANELS

USER GUIDE. Security Control Panels INS046-7

THANK YOU FOR VOTING TEXECOM THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels 1 INS167

5 Sounds and Indications

2200 and 2200L ALARM CONTROL SYSTEMS

PARAGON PLUS USER INSTRUCTIONS USER INSTRUCTIONS J?>5 J?>5 J?>5 J?>5 J?>5 J?>5 B??=

HARDWIRED CONTROL PANELS

Security System. User s Guide for the Text Command Center

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Security System. User Guide for the LED Command Center

SECURIT 700L PLUS ENGINEERING MANUAL

USER GUIDE HARDWIRED CONTROL PANELS

Scantronic Leading the way in security

M800, M800iD Plus, M1000 and M3000. User's Guide

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

INSTALLATION MANUAL SECURIT 802 CONTROL PANEL

8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u

HILLS Series LED Code Pad User Manual

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

PARAGON USER INSTRUCTIONS J?>5 J?>5 J?>5 J?>5 B??= CD1DEC;5I* 5-5>DBI5H9D1-1335CC9-9==5491D5?-?=9DD54 5 < * 1 < < 1 C *

CONQUEROR USER INSTRUCTIONS J?>5! J?>5 J?>5 J?>5 B??= CD1DEC;5I* 5-5>DBI5H9D1-1335CC9-9==5491D5?-?=9DD54 RINS 061 ISSUE-1

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

USER GUIDE HARDWIRED CONTROL PANELS

USER GUIDE HARDWIRED CONTROL PANELS

Installation Manual Premier 412/816/832. Issue 10

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

Contents. Glossary

D1265. User's Guide. Touchscreen Keypad

Welcome to. Welcome to Security and Peace of Mind CASTLE CARE TECH CARE TECH CARE TECH CARE TECH

Watchguard WGAP864 User Manual

AP10LED 10 Zone onboard LED Alarm Panel. Engineering Manual

Sentry 4 Zone Alarm Panel User Manual

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

QUICK CONSUMER REFERENCE GUIDE

Fire Command Keypad. XR5 User s Guide

SECURITY SYSTEM NOTES

U ser's Guide PC6010

Tomorrow s technology for today s security needs.

Condominium Security Management System

NetworX NX-8V2. LED Keypad User Manual

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

NetworX Series NX-1500E LED Keypad

NETWORX TM. User manual NX-4

Microprocessor Intruder Alarm System User Guide

User s Information Guide R2A

MOOSE MPI 50 CONTROL PANNEL

16 and 16 plus User s Guide

Advantage 6 Alarm Panel

PROGRAMMING PROCEDURES (Table 3)

LED Keypads D720 Series User s Guide

IDS816 User Manual H Issued January 2009

Master User Guide Premier Elite Series

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

Table of Contents. Page Code

Table of Contents About This User s Guide... 2 Introduction... 2 Security System Basics... 3 What is a Point?... 3 What is a Faulted Point?...

EasyLoader. End User Manual

LS800S Intruder Alarm System. Engineering Manual

NX-148 LCD CODE PAD TABLE OF CONTENTS

Summit 3208GLD USER MANUAL. Electronics Line

Scantronic Leading the way in security

Summary of Keypad Main User Commands

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panel with Communicator Interface

Solution Ultima 862 Operators Manual ISSUE 1.10

Solution 844 Operators Manual ISSUE 1.10

Power864. User s Guide. Now classified in accordance with ANSI/SIA CP (SIA-FAR)

Introduction. When using an LED keypad for Abacus 6P (or some older Abacus panels) refer to the LED Operator instructions guide (Part No. Y6055).

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

Euro ONE. RENDER ALARMS Your security, above all else. User Manual. t: f:

Digiplex LED Keypads User s Manual

SCORPION Z16040C, Z8040C and Z5120C

CONTENTS. 1 INTRODUCTION 2 Planning the installation 2 Nexus 8 installation example 3


ADVISOR CD User Manual. Software from version: V

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

INSTRUCTION MANUAL PC255O

Destiny Destiny Owners Manual

3 User s settings. 3.3 Internal clock setting

Intruder - Fire - Water Combined Alarm

EURO 46 User Manual. For use with EURO 46 (version 9.1 or above) RINS1531-2

Version 1.03 January-2002 USER S MANUAL

INSTRUCTION MANUAL PC255O

Transcription:

TS400 & TS410 Intruder Alarm Control Panels Operating Instructions Zone Location Home Set Chime 1 Armed / Omitted 2 Armed / Omitted 3 Armed / Omitted 4 Armed / Omitted 5 Armed / Omitted F. Exit Always Armed

Introduction The TS400 and TS410 are 6 zone microprocessor based intruder alarm panels. Before attempting to operate the system, please ensure that you have read these instructions and discussed the operation of the system with the installation engineer. If you experience problems with the alarm system refer to the "Fault Finding" section on the back page. Operator Controls & Indicators 1 2 4 3 1 2 3 4 5 6 7 8 9 0 5 7 6 Figure 1 Operator Controls & Indicators 1 Zone Indicators These red indicators are used to show the status of zones 1 to 5. 2 Unset Indicator This green indicator is used to indicate the status of the system, set or unset. It also flashes when the mains power to the system is removed or when the master user selects the user menu. 3 Tamper Indicator This red indicator is used to indicate a system tamper alarm, i.e. someone removing the cover from a detector or control panel. The tamper indicator will also flash when the selecting "chime" circuits. 4 Final Exit Indicator This red indicator is used to show the status of the final exit zone. The final exit zone is normally the front door or last detector triggered when leaving the building. 5 Keypad 10 digit keypad used for operating the system. 6 Away Key The away key is used when full setting the system. 7 Home key The home key is used when part setting the system. 2

Away Set The away set option is used to arm all zones when you leave the premises. Before attempting to set the system, ensure that all doors and windows are securely closed. If pets are to be left inside the protected premises they must not have access to areas protected by movement detectors. 1 Enter the first 2 digits of your passcode followed by [AWAY]. The internal sounder will sound, the unset indicator will go out and the final exit indicator will flash.?? 2 Leave the premises via the designated exit route. 3 The internal sounder will change to a high pitched tone, after 5 seconds a multi-tone sound will be heard and the system fully sets. If the internal sounder changes to an alarm tone, you must re-enter the premises and enter your passcode. The indicators that are lit are the zones that prevented the system from setting. Check the relevant zones and repeat above procedure. Home Set The exit sounder will start, the unset indicator will go out and final exit indicator flashes. Leave the building via the exit route. The exit sounder will eventually change to a high pitched tone. When the tone stops the system is fully set. All indicators are off when the system is set. The home set option is used when staying inside the premises and only arming some of the zones. To program the zones that will be omitted see "Home Set Configuration" on page 7. Before attempting to set the system, ensure that all doors and windows are securely closed. If pets are to be left inside the protected premises they must not have access to areas protected by movement detectors. 1 Enter the first 2 digits of your passcode followed by [HOME]. The internal sounder will emit a multi-tone sound, the unset indicator will go out and the final exit indicator will flash. The indicators for the zones that will be omitted will also flash. 2 Leave the area to be protected via the designated exit route. 3 When the second multi-tone sound is heard the system is part set. If the internal sounder changes to an alarm tone, you must proceed to the keypad and enter your passcode. The indicators that are lit are the zones that prevented the system from setting. Check the relevant zones and repeat above procedure.?? A multi-tone beep will be heard, the unset indicator will go out and the final exit indicator flashes. The zones that will be omitted will also flash (e.g. zones 4 and 5). Leave the protected area via the exit route. When the multi-tone beep is heard the system is part set. All indicators are off when the system is set. 3

To unset the system, proceed as follows: Unsetting The System 1 Enter the premises via the designate entry door. The internal sounder will sound. 2 Proceed directly to the keypad and enter all 4 digits of your passcode. 3 The sounder will stop and the unset indicator will light. The system is now unset. If the programmed entry time is exceeded, the internal sounder will emit an alarm tone for the duration of the programmed entry time. If a valid passcode is not entered at the keypad before the addition time expires, a full alarm will occur, i.e. internal and external alarm. Enter the building via the designated entry point. Proceed directly to the keypad and enter all 4 digits of your passcode.???? The system is now unset. Resetting After an Alarm When an alarm has occurred the system will require resetting before the system can set again. Your alarm company will have configured your system to be reset by one of the following methods: User Reset: Engineer Reset: Remote Reset: When an alarm occurs with the system full or part set proceed as follows: 1 Enter the premises via the designate entry route. The internal sounder will sound. 2 Proceed directly to the keypad and enter all 4 digits of your passcode. 3 The sounder will stop and the unset indicator will light. The zone indicators associated with the alarm condition will also light. 4 Check the system as necessary. 5 Enter your passcode again to reset the system. The zone indicator that was lit will go out. The system is now reset. If after unsetting the system the internal sounder continues to emits a pulsed tone, the system will require a reset by either engineer or remote reset. To silence the pulsed tone, enter your passcode. For engineer reset telephone: For remote reset telephone: Enter the building via the designated entry point. Proceed directly to the keypad and enter all 4 digits of your passcode.???? The system is unset and the zone that caused the alarm is indicated (e.g. zone 3).???? The system is now reset. 4

Bell Test This function allows user 1 to periodically test the operation of the internal sounders, external sounders and strobe. then [1]. 2 All indicators will light and the internal sounder will operate for five seconds. 3 Then the external sounder will operate for five seconds. 4 Then the external strobe will operate for fifteen seconds. 5 When the test is completed, the system will return to the unset mode. 6 To stop the test at any time and return the system to the unset mode, press [0]. a) b) c)??? 1 All indicators light and the internal sounder operates for 5 seconds. The external sounder operates for 5 seconds. The strobe operates for 15 seconds. When the test is completted the system returns to the unset mode. Walk Test This option allows user 1 to periodically test the operation of detectors and door contacts. Operating detectors whilst the system is in the walk test mode will cause the internal sounder to emit a pulsed tone and the appropriate zone indicator to light. then [2]. 2 Operate each zone in turn by opening doors fitted with alarm contacts and walking in front of movement detectors. 3 When the test is completed press [0]. A high pitch acceptance tone will be heard and the system returns to the unset mode. a)??? 2 Operate each zone in turn (e.g. zone 1). b) The appropriate indicator will light and the internal sounder will pulse. c) When finished press 0 The system is now in the unset mode. 5

Changing Passcode 1 (Master) This option allows user 1 to change their passcode. The default passcode when the panel leaves the factory is 5 6 7 8. then [4].??? 4 2 Indicators 1 to 4 will light. 3 Enter your new passcode, as you enter each digit the indicators will go out one by one. 4 On entering all four digits, indicators 1 to 4 will light again. 5 Re-enter your new passcode again for confirmation, as you enter each digit the indicators will go out one by one. Indicators 1-4 light. Enter new passcode. Indicators 1-4 light again. Enter new passcode for confirmation. 6 After entering your new passcode for the second time the system will return to the unset mode. 7 A rising tone indicates the new passcode was accepted, a falling tone indicates an error and the above procedure must be repeated. A rising tone indicates acceptance. A falling tone indicates an error. Changing Passcode 2 This option allows user 1 to change user 2 passcode. then [6].??? 6 2 Indicators 1 to 4 will light. 3 Enter the new passcode, as you enter each digit the indicators will go out one by one. 4 On entering all four digits, indicators 1 to 4 will light again. 5 Re-enter the new passcode again for confirmation, as you enter each digit the indicators will go out one by one. Indicators 1-4 light. Enter new passcode. Indicators 1-4 light again. Enter new passcode for confirmation. 6 After entering the new passcode for the second time the system will return to the unset mode. 7 A high rising tone indicates the new passcode was accepted, a falling tone indicates an error and the above procedure must be repeated. A rising tone indicates acceptance. A falling tone indicates an error. The second user passcode will be lost if all power to the control panel fails. 6

Home Set Configuration This option allows user 1 to select which zones will be omitted when a "Home Set" is selected. The final exit zone cannot be omitted when selecting zones. then [7].??? 7 2 Press keys [1] to [5] to turn zone indicators 1-5 on and off. When a zone indicator is lit the zone will be omitted. When a zone indicator is off the zone will be armed. 3 When completed press [0]. A rising acceptance tone will be heard and the system returns to the unset mode. If zones 3, 4 or 5 cannot be selected then they have been programmed by your alarm company for alternative operation, i.e. keyswitch, Fire or PA. Press keys [1] to [5] to select zones. e.g. Press [4] then [5]. Zones 4 and 5 are now selected to be omitted. When finished press 0 The system is now in the unset mode. Chime Feature This feature allows the selected zones to generate a two-tone beep every time the zone is triggered when the system is unset. This may be used as a courtesy warning of the opening of a shop door etc. 1 Press [HOME] then [HOME]. 2 Press keys [1] to [6] to turn zone indicators 1-5 on and off (6 is used for the final exit zone). When a zone indicator is lit the zone will be selected as "Chime". When a zone indicator is off the zone will not chime. 3 When completed press [0]. A rising acceptance tone will be heard and the system returns to the unset mode. If zones 3, 4 or 5 cannot be selected then they have been programmed by your alarm company for alternative operation, i.e. keyswitch, Fire or PA. Press keys [1] to [6] to select chime zones. e.g. Press [6] for the final exit. The final exit zone is now selected for chime. When finished press 0 The system is now in the unset mode. 7

Fault Finding I enter my passcode to set the system but the system emits an intermittent sound and one of the indicator zones is on. The tone indicates that a detector is active or a door has been left open. The indicator that is on, indicates which detector or door is active. Close doors, wait 10 seconds and try again. If the problem persists contact your alarm company. After unsetting the system one of the zone indicators remained on. The indicator shows the alarm zone that was activated when the system was set. Please refer to the section on "Resetting After an Alarm" after checking the building. The system emits an two-tone beep every time I open certain doors. The system has a facility called "Chime", which causes the internal sounders to emit a two-tone beep every time certain zones are activated. To turn this facility on or off, see the section on "Chime". The internal sounder and TAMPER indicator comes on during the day. This shows that the panel has detected a "tamper" fault, i.e. a wiring fault or a cover removed from a detector, control panel or external siren. Call your alarm company immediately. The system was in the unset mode and the internal sounder operated, and external sounder sounds pulses on and off. The system has a facility to monitor smoke detectors (zone 4). If one of these is activated, the external siren will be pulsed on and off to show that the alarm was caused by a fire and not a burglar. Check the smoke detector to ensure that they are clear of smoke. If the problem persists contact your alarm company. The UNSET indicator is flashing. The mains power to the panel is off or the internal fuse has blown. The system will operate from the internal battery for about 8 hours. If the mains to the building is on, contact your alarm company. When setting the system, the external strobe starts to flash. This shows that the system has not set correctly. Re-enter the building, clear the indications and try again. Although I follow the correct procedure, the system will not allow me to change my passcode. The system analyses the new code entered and may refuse to accept certain code combinations for technical reasons. Try repeating the procedure with a different passcode. 18015 Drg No. 33:1939:00 Issue 01 Doc. 02 April, 1997