FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

Similar documents
ASA linear smoke detector

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

Input module, input/output modules

DF1101-Ex Infrared flame detector

Multi line separator module

Input module, input/output module

DF1151-Ex Infrared flame detector

FDOOT241-9, FDOOT241-A, FDO241, FDT241

Output module (230 V)

FDOOT221, FDO221, FDT221

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

OH720, OP720, HI720, HI722

Mimic display driver, LED ribbon cable

FDCIO223 (ES 45) Transponder

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

FDOOT241-A9-Ex Multisensor fire detector

Interbases. Sinteso FDSB221, FDSB228, FDSB229

FDCL221-M Multi line separator module

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

OOH740, OOHC740 Automatic fire detectors

OOH740-A9-Ex Multisensor fire detector

FDCL221-Ex Line adapter (Ex)

DT1101A / DT1102A / DO110xA Automatic fire detectors

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

DM1131 / DM1133 / DM1134 Manual call points

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

SWING radio fire detection system

OOH740-A9-Ex Multi-sensor fire detector

FDBZ290 Air sampling smoke detection kit

FDBZ290 Air sampling smoke detection kit

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

DC1192 Input /Output module

Fire control panels FC360

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Radio fire detection system

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

Fire control panels FC726 FC726-XA

FC2040. Fire control panel. Sinteso. FS20 series, MP6

FC724 Fire control panel

FC722 Fire control panel

FC722 Fire control panel

FC724 Fire control panel

FDL241-9 Linear smoke detector Mounting Commissioning

Fire control panel for modernization

FT2080 Fire terminal (Touch) Mounting Installation

FT2080 Fire terminal (Touch) Mounting Installation

Fire & Security Products. Siemens Flame Detector a highlight in detection. technology.

FC723 Fire control panel

FDCW241 Radio gateway Mounting

Room thermostat with 24-hour time switch and large LCD

Test units and accessories

FD20 Sinteso Detector system

FC2020 Fire control panel

FDA241, FDA221 Siemens ASD

Electronic timeswitch

DOW1171 / DCW1151 Radio fire detection system

Synova TM product catalog.

OH110, OP110, HI110 Automatic fire detectors

XC10 Extinguishing control panels

FDM273 Radio manual call point Mounting

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

FDCL221 Line separator

Test units and accessories

Sinteso TM product catalog.

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

Flush-mounted room thermostat

FDCI221, FDCIO221 Input module, input/output module Technical Manual

XC10 combined fire detection and extinguishing control

XC10 combined fire detection and extinguishing control

Frost Protection Thermostat

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

FS720 Fire detection system (marine) Technical Manual

Test units and accessories

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Room Temperature Sensors

Duct Temperature Sensors

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

FP120-Z1 Power supply kit A (70 W) Technical Manual

FDBZ290 Air sampling smoke detection kit Technical Manual

FDA241, FDA221 Siemens ASD

Room Temperature Controllers

Building Technologies. FDUL221 en Line tester operating instructions for electricians

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

1592P01. for liquids in piping DN

Room thermostats with LCD RDD100..

FDOOT241-A9-Ex Automatic fire detector Technical Manual

FDS229 Alarm sounder with supplementary optical indication Technical Manual

Flush-mounted room thermostats

Cerberus FIT conventional system

FS20 Fire detection system

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

OH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual

Duct Air Quality Sensors

Room Temperature Controller

Transcription:

Sinteso Cerberus PRO Cerberus FIT FDF241-9 Flame detector Flame detector addressed or collective, ASAtechnology TM Reliable detection using three infrared sensors and ASAtechnology (indoor and outdoor application) Excellent false alarm immunity thanks to fuzzy logic and wavelet analysis Event-controlled detection behavior Microprocessor-controlled signal processing Two-wire installation for all cable types Communication via FDnet/C-NET (individually addressed) or collective detector line (switchover) 2016-07-06 Control Products and Systems

Properties Features Integrated line separator: The defective part on the detector line is located by the fire control panel and isolated between two FDnet/C-NET devices. The aluminum detector housing also acts as shielding against electromagnetic interference. The housing is made from hard-wearing, glass-fiber-reinforced plastic. Protected electronics Built-in alarm indicator Addressed and collective signal processing Eco-friendly Environmentally friendly processing Reusable materials Electronic parts and synthetic materials can be easily separated Functions The flame detector measures infrared radiation and can therefore detect liquid and gas fires without smoke and organic material fires with smoke. It has three sensors with ASAtechnology and can distinguish between deceptive phenomena and real fires. Pyroelectric sensor A measures the infrared radiation in the characteristic CO2 spectral range between 4.0 and 4.8 µm. Pyroelectric sensor B measures the infrared radiation of deceptive phenomena, such as hot objects, in the range between 5.1 and 6.0 µm. Sensor C is a silicon photo diode and measures solar radiation in the range between 0.7 and 1.1 µm. A sensor measures the hot CO2 at a specific wavelength of the flame; the other two sensors measure interference radiation at other wavelengths at the same time. With the intelligent signal processing using fuzzy algorithms and wavelet analysis, the flame detector achieves excellent detection reliability with maximum immunity to interference emitters and sunlight at the same time. In order to safeguard against a possible decision emergency, the flame detector contains an additional emergency activation channel. Signal + Time Wavelet Fuzzy wavelet Fuzzy logic 2

Fields of application The flame detector is suited to use in environments with deceptive phenomena, such as solar radiation or hot motors. Large industrial storage rooms Power plants Chemical production facilities Transformer stations Warehouses for chemicals Print shops Gas depots and pump stations Motor test beds Arc welding Atriums, malls Ferries and cargo ships Wood storage Machine rooms on ships Hangars for military and civil aircrafts Subway tunnels Accessories Mounting bracket MV1 For room monitoring For fixing flame detector at 45 Ball and socket joint MWV1 For fixing flame detector at the angle and in the direction required For accurately aligning the flame detector to an area Rain hood (plastic) FDFZ241 Rain hood made of plastic (ABS) For protecting the flame detector during outdoor applications 3

Rain hood DFZ1190 Rain hood made of stainless steel For protecting the flame detector during outdoor applications Test lamp LE3 For testing the function of all flame detectors at distances up to 10 m Type Overview Flame detector FDF241-9 Type Designation Order number Weight [kg] FDF241-9 Flame detector A5Q00003006 0.500 Accessories for flame detector FDF241-9 Type Designation Order number Weight [kg] FDFB291 Base for flame detector A5Q00003310 0.250 M20 x 1.5 metal cable gland A5Q00004478 0.036 MV1 Mounting bracket BPZ:3950450001 0.285 MWV1 Ball and socket joint BPZ:3674840001 0.860 DFZ1190 Rain hood BPZ:5302660001 0.640 FDFZ241 Rain hood (plastic) S54330-N4-A1 0.232 4

Product documentation Document ID Name 008164 Equipment overview Sinteso Detector system FD20 A6V10225323 Equipment overview Cerberus PRO Detector system FD720 008331 List of compatibility (for 'Sinteso ' product line) A6V10229261 A6V10882301 List of compatibility (for 'Cerberus PRO' product line) List of compatibility (for 'FC360' product line) 007011 Technical manual Flame detector FDF241-9 008121 Installation Infrared flame detector FDF241-9 A6V10882455 Notes Installation Rain hood FDFZ241 Related documents such as environmental declarations, CE declarations, etc., can be downloaded at the following Internet address: http://siemens.com/bt/download Mounting Disposal Mounting options Easy mounting of the housing on stable, vibration-free surfaces. The flame detector is only used once installation has been checked just before commissioning. In the housing: 6x thread M20 for cable glands Connection to the control panel via a wire pair External alarm indicator can be connected Pluggable connection between flame detector and base The device is considered an electronics device for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. 5

Technical data Flame detector FDF241-9 Operating voltage (quiet) addressed / collective Operating current (quiet) addressed / collective External alarm indicator (AI) can be connected and configured externally DC 12 33 V / DC 14 28 V 0.7 ma / 0.5 ma Operating temperature -35 +70 C Storage temperature -40 +75 C Air humidity (no moisture condensation) Communication protocol Cable cross section Color Protection category (IEC 60529) 2 95 % rel. FDnet/C-NET or collective (with and without current limitation) 0.2 1.5 mm² ~RAL 9010 pure white IP67 Standards EN 54-10, EN 54-17 Approvals VdS LPCB DNV GL (marine) System compatibility FDnet C-NET Collective system compatibility G204010 126bc/05 45 248 16 HH FS20, AlgoRex, SIGMASYS FS720, FC360 CZ10, BC10, FC10, XC10, CS11, FC700A, FC330A, SIGMASYS, BMS, SM80/88/D100 07 0786 FDF241-9 Siemens Switzerland Ltd; Gubelstrasse 22 CH-6301 Zug Technical data: see doc. 007011 FDF241-9 - Flame detector incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-10 / EN 54-17 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0786-CPR-20372; DoC No.: CED-FDF241-9 6

Dimensional drawings Base for flame detector FDFB291 Base for flame detector FDFB291 with flame detector FDF241-9 M20 x 1.5 153.5 108 135 45 77 4.5 135 Mounting bracket MV1 Ball and socket joint MWV1 120 120 120 136 118 164 Rain hood DFZ1190 150 130 Rain hood FDFZ241 255 121 165 197 125.5 95 7

Issued by Siemens Switzerland Ltd Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2007 Technical specifications and availability subject to change without notice. 8 Document ID Manual FD20/FD720 Edition 2016-07-06 Register 3 / 3