Hygrometer / Air Quality Meter

Similar documents
Leak detector for refrigerant gases R22, R134a, R410A, R407C...

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

ALTAIR 5X Multigas Detector Product Specification

GasAlertMicroClip X3 Specifications

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Monitores Personales. Personal Monitor

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

CO warning instruments and gas spillage detectors

portable gas analyser

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

G-TECTA TM. Portable Gas Detection Instruments

Dräger X-am 2500 Multi-Gas Detection

ALTAIR 5X Multigas Detector

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

Dräger X-am 7000 Multi-Gas Detection

OLC(T) 100 FIXED GAS DETECTOR

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex

Polytector III G999 for Ex zone 0

3M Oldham OLCT 100. Description. Fixed Gas Detector

P R O D U C T D ATA S H E E T

Dräger X-am 5000 Multi-Gas Detection

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

Dräger Polytron 8000 Stationary gas detector (EC)

For the Safety of Your

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

Safe Operation Manual. Honeywell IQ Force Gas Detector

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

We measure it. testo 316-Ex CH 4 testo 316-1

Dräger X-am 7000 Multi-Gas Detection

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

VENTIS PRO SERIES. Product Guide

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

Dräger X-am 5000 Multi-Gas Detection

MSA Portable Gas Detection

Danfoss gas detection units

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

The GasWatch 2 will operate for over 3,000 hours on one battery (about 1 year normal use). And yes, the GasWatch 2 even tells the time!

Dräger X-am 2500 Multi-Gas Detector

IMR IX176 Portable Gas Detector User Manual

Danfoss gas detection unit Type GD Heavy Duty

portable gas analyser

GAS ANALYSIS / DETECTION Gas Detector

testo 316-EX gas leak detector Instruction manual

ALTAIR 5X Multigas Detector

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

IMR EX610. Portable Gas Detector. Operation Manual

Danfoss gas detection units

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Single Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Toxic Gas Detection. Model F12. Toxic Gas Detection

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

S5000 Gas Monitor. GMS5000.com

Dräger Pac 6000 Single-Gas Detector

Dräger X-am 5000 Multi-Gas Detector

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Two-Channel Gas Controller

E1000 Portable gas detector

MicroRay IR-100 NEW. Inspection MicroRay IR-100

APPLICATION DATA SHEET

SIL 2. Ultima X Series Gas Monitors CERTIFIED

ULTIMA X5000. MSAX5000.com

Dräger Polytron 8310 IR Detection of flammable gases and vapour

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Model D12-IR. Digital Gas Transmitter...

Using the QRAE Plus personal multigas monitor

GAS DETECTOR ST400EC PART.NO

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

P R O D U C T D ATA S H E E T

IGD.CO.UK

IT S WHAT S INSIDE THAT

Recalibrate the way you look at gas detection

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Micro III (Models G203, G203S, and G213) Operation Manual

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

multi-gas detector Go the distance, and save Wear yellow. Work safe.

EasyLog Data Logger Series

Neotronics Impact & Impact Pro

MODEL: SP2nd (Portable Single Gas Detector) Operating Manual

Dräger Pac 8500 Single-Gas Detector

EL-USB-TC Thermocouple Data Logger with USB Interface

MICRO IV. Operation Manual. Single Gas Detector

1.1 Definitions of alert icons. For your safety

Transcription:

Hygrometer / Air Quality Meter PCE-313 A Professional Thermohygrometer with SD Card Memory / Data Logger measures temperature and humidity by internal sensor and temperature by K type thermocouple calculates the dew point and wet bulb temperature internal real-time memory via SD card (1... 16 GB the stored data are saved directly to the SD card in Excel format 2 GB SD card and card reader included in the delivery optional software to transfer data to the PC in real time (software is not needed to analyse the stored data PCE-313 S model includes sintered cap PCE-G1 and PCE-G1A for Temperature and Humidity visible from distances of up to 50 m clearly readable LED digits with a height of 100 the measured temperature and humidity values are displayed in turns 4... 20 ma output / quick response time long-term stable sensor IP 54 protection Meas. range RH: 5... 95 % / Temperature: internal sensor 0... +50 C / K type -50... +1300 C Resolution 0.1 % RH / 0.1 C Accuracy RH: ±3 % at >70 % RH / ±3 % of reading ±1 % at <70 % RH Temperature (internal sensor: ±0.8 C / Temperature (type K: ± 0.4 % + 0.5 C Memory SD card (1... 16 GB Measurement rate 1... 3600 s (adjustable Interface RS-232 LCD Operating cond. 0... +50 C, < 85 % relative humidity Power supply 6 x 1.5 V batteries Dimensions 177 x 68 x 45 mm 490 g Thermohygrometer, combined temperature and humidity sensor, SD memory card (2 GB, card reader, batteries, instruction manual NO. K-PCE-313A thermohygrometer K-PCE-313 S thermohygrometer / data logger (like PCE-313 A, with sintered cap K-SOFT-LUT-B02 RS-232 data cable with software to transfer data in real time K-CAL-PCE-HT110 ISO calibration certificate K-CAL-SET-RF calibration set 33% / 75% RH Meas. range 10... 95 % RH / 0... +60 C Resolution 1 % RH / 1 C Accuracy ± 2 % RH / ± 1 C Sensor capacitive / Pt1000 / 1 m cable Output 4... 20 ma Response time 4 s LED 100 mm Visibility from approx. 50 m Power supply 230 V / 50... 60 Hz Dimensions sensor: 50 x 70 x 20 mm display: 175 x 175 x 75 mm 1300 g, sensor for RH and temperature, mains cable, instruction manual K-PCE-G1 display K-PCE-G1A display with analogue output K-CAL-PCE-G1 ISO calibration certificate 1-800-TEST-INSTRUMENTS 29

PCE-LD 1 Gas Leak Indicator for Refrigerants for refrigerants R22, R134a, R410A, R407C,... can be used anywhere sensor at the end of a gooseneck of 390 mm acoustic and visual alarm multi-colour LED shows concentration of gas PCE-LDC 2 Camera to Detect and Capture Compressed Air Leakages ultrasonic measurement with visual representation of leakages / discharge localisation image of the leakage - localisation is saved and numbered along with date, time and sound level continuous measurement of db, RMS and MAX value colour display with bar indication adjustable gain of 50... 110 db adjustable frequeny of 34... 46 khz powered by rechargeable battery, max. 6 hours data transfer to PC via USB interface Sensitivity adjustable (high & low Warm-up time approx. 90 s Detectable gases R22, R134a, R404, R407C, R410A... Test cycle continuous Sensor length 390 mm sensor with gooseneck multi-colour LED Power supply 4 x 1.5 V AA batteries Battery life approx. 40 h (with normal use Automatic power Off after 10 min Operating conditions -10... +60 C / <70 % RH Dimensions 173 x 66 x 56 mm 400 g Gas leak indicator, sensor, testing agent, carrying case, batteries, instruction manual NO. K-PCE-LD 1 gas leak indicator K-ESS-PCE-LD 1 replacement sensor Not to be used for flammable gases!!! Sensitivity detects leakages of 0.1 mm at 3 bar, distance of 20 m Warm-up time approx. 90 s Detactable gases R22, R134a, R404, R407C, R410A... Target window square and target cross, slight leakages in yellow, considerable leakages in red Test cycle continuous Sensor length: 390 mm bandwidth: ±2 khz up t o 6 db fundamental frequ.: 40 khz ±1 khz mixed frequ.: adjustable 34... 46 khz gain: automatic or adjustable from 50... 110 db optional: senosr with flexible gooseneck for areas difficult to access, 400 mm; contact sensor for steam traps and mechanical applications Headphones volume adjustable from 0... 10 Functions real-time RMS, max. RMS; brightness of display and camera adjustable from 0... 10; Languages English, German, French Interface USB Memory up to 1000 imgaes Camera 640 x 480 pixels Image format JPEG LC colour display 3.5 ; 320 x 240 pixels Power supply recharg. li-ion battery 5 V dc, 2 A, charging time approx. 5 h Operating cond. -10... +50 C Battery life approx. 6 h (normal use Dimensions 230 x 100 x 70 mm device: approx. 580 g complete delivery cont.: approx. 4 kg Leak detection camera, headphones, rechargeable battery, charger, USB cable, softw., metal case, manual K-PCE-LDC 2 leak detection camera K-PCE-LDC-Flex sensor with flexible gooseneck, 400 mm K-PCE-LDC-Probe contact sensor www.pce-instruments.com/english 141

Gasman Single Gas Detector for Personal Protection with ATEX Approval for Flammable Gases (Ex, Oxygen (O 2 or Toxic Gases (CO, CO 2, H 2 S,... freely adjustable alarm level / vibration alarm, LED alarm, beeper comfortable to carry all day long / can be used in Ex areas protection class: dust- and waterproof IP 65 / 67 LC display with backlight internal calibration via keypad data logger function Gas types available Model Gas Meas. range Alarm Gasman-CL2 chlorine 0...20 ppm 0.5 ppm Gasman-CO carbon monoxide 0... 500 ppm 30 ppm Gasman-CO2 carbon dioxide 0...5 vol % 0.5 u. 1.5 vol % Gasman-FL flammable gases 0... 100 % UEG 20 % UEG Gasman-H2 hydrogen 0... 2.000 100 ppm Gasman-H2S hydrogen sulfide 0... 100 ppm 5 ppm Gasman-NH3 ammonia 0... 100 ppm 25 ppm Gasman-NO2 nitrogen dioxide 0... 1 ppm 1 ppm Gasman-O2 oxygen 0...25 vol% 19 u. 23 vol % Gasman-O3 ozone 0... 1 ppm 0.1 ppm Gasman-SO2 sulphur dioxide 0... 10 ppm 1 ppm TOP seller Response time. flammable gases 20 s, toxic gases 20 s, oxygen 10 s Alarm acoustic (95 dba, visual (LED red / blue, internal vibration Sampling optional hand-operated bellows pump Data protocol capacity for 5000 events, including: switch on / off, battery level, activated / deleted alarms, peak values, passed or failed gas test, all events time-stamped Memory pre-set: 900 hours of storage at 1 min. intervals, storage intervals can only be changed using the software Interface RS-232 via module in charger, USB adaptor optional Calibration routinely by means of Autocalibrator II or via PC software LCD with backlight, battery level indicator, indicates when calibration and maintenance is necessary Indication real-time gas values, retrievable peak values and TWA Power supply rechargable lithium ion battery (flammable gases, CO 2 / non-rechargable lithium cell (toxic gases and oxygen Op. conditions -20... +55 C / 0... 99 % RH Approvals ATEX II 1G EEx ia IIC T4 (ambient temp. -20... +55 C toxic gases and oxygen / ATEX II 2G EEx iad IIC T4 (oper. temp. -20... +55 C flammable gases Norms EN50014, EN50020, EN50018, 94/9/EC, EN50270, EN50271, EN61779 software designed to meet IEC61508 Gas detector with sensor, pocket clip, battery or Li-Ion battery with charger (depending on the gas, calibration certificate, instruction manual 142 www.pce-instruments.com/us NO. K-Gasman-Cl2 chlorine detector K-Gasman-CO carbon monoxide detector K-Gasman-CO2 carbon dioxide detector, with charger K-Gasman-FL flammable gases detector, with charger K-Gasman-H2 hydrogen detector K-Gasman-H2S hydrogen sulfide detector K-Gasman-NH3 ammonia detector K-Gasman-NO nitrogen monoxide detector K-Gasman-NO2 nitrogen dioxide detector K-Gasman-O2 oxygen detector K-Gasman-O3 ozone detector K-Gasman-SO2 sulphur dioxide detector K-LADE-G-N 230 V charger K-LADE12V-G-N 12 V vehicle recharger cable K-INT-G-N 230 V charger with data interface K-SW-G-N software for PC K-RS232-G-N RS-232 data cable K-RS232-USB adaptor RS-232 to USB interface K-ASP-G-N hand-operated bellows suction pump (not for O 3, Cl 2 and NO 2 K-CAL-G-N calibration and maintenance (e. g. every 6 months

TETRA Multi-Gas Detector for Professional Use (ATEX II 2G Eex iad IIC T4 acoustic alarm: 90 db (A visual alarm: red and blue LED / vibration alarm single-button operation sensors are even interchangeable in dangerous areas internal automatic gas suction pump available for extra charge Approvals: Europe: ATEX II 2G EEx iad IIC T4 (-20... +55 C BASEEFA 03ATEX0193 USA & Canada: Class I Division 1 Instruments. A, B, C, D Standards / codes: Europe: EN50014, EN50020, EN50018, 94/9/EC EN50270, EN 50271, IEC61508 USA & Canada: UL913, CSA22.2, 152 (LEL = flammable gases such as methane Model TETRA-1 TETRA-2 TETRA-3 TETRA-4 TETRA-5 Measurement range (LEL, O 2 (LEL, O 2, H 2 S (LEL, CO, O 2 (LEL, O 2, CO, H 2 S (O 2, O 3 LEL 0... 100 % 0... 100 % 0... 100 % 0... 100 % - - - O 2 0... 25 % 0... 25 % 0... 25 % 0... 25 % 0... 25 % O 3 - - - - - - - - - - - - 0... 100 ppm CO - - - - - - 0... 500 ppm 0... 500 ppm - - - H 2 S - - - 0... 100 ppm - - - 0... 100 ppm - - - Alarm limits LEL 20 % 20 % 20 % 20 % - - - O 2 19.5 and 23.5 % 19.5 and 23.5 % 19.5 and 23.5 % 19.5 and 23.5 % 19.5 & 23.5 % O 3 - - - - - - - - - - - - 0.1 ppm CO - - - - - - 30 ppm 30 ppm - - - H 2 S - - - 5 ppm - - - 5 ppm - - - Sensor life typical: flammable g.: approx. 5 years / toxic g.: approx. 3 years / oxygen: approx. 2 years Response time T90 = methane and other inflammable gases: 20 s / toxic gases: 20 s / oxygen: 10 s Alarm visual: 2 flashing red and blue LEDs; acoustic: 90 db (A at 1 m distance; vibration graphical LCD, with backlight, battery level indicator, 128 x 64 pixels Memory data logger & event recorder (e. g. when limits are exceeded Interface for PC IR interface Software optional, for configuration, calibration and data access Power supply rechargable lithium ion battery (min. 12 h of continous use, with internal pump min. 8 h Operating conditions -20... +55 C / 0... 99 % RH Protection can be used in ex areas, dust and waterproof, resistant to chemical corrosion, IP 65 Dimensions / weight 122 x 128 x 57 mm / 500 g TETRA (model -1,-2,-3,-4 or-5, rechargeable battery, instruction manual (please order charger separately, other gases on request K-TETRA-1 2-gas for LEL and O K-TETRA-2 3-gas for LEL, O 2 / H 2 S K-TETRA-3 3-gas for LEL, O 2 / CO K-TETRA-4 4-gas for LEL, O 2 / CO/ H 2 S K-TETRA-5 2-gas O 2 / O 3 K-TETRA-IP internal gas suction pump (not possible for O 3 K-TETRA-LS 230 V / 50 Hz charger K-TETRA-ASP suction set (gas suction by means of hand-operated bellows K-TETRA-INT RS-232 interface for PR, IR adaptor K-TETRA-SW software K-ESS-T-LEL additional sensor LEL K-ESS-T-O2 additional sensor O 2 K-ESS-T-H2S additional sensor H 2 S K-ESS-T-CO additional sensor CO K-CAL-TETRA calibration / maintenance K-C01863 carrying strap www.pce-instruments.com/english 143

GAZEX Multi-Scale Gas Detector for Hazardous Areas (ATEX optical / acoustic / vibration alarm up to three measurement ranges (ppm, LEL, VOL / response time T90 20 s 2 alarms: 20 % and 40 % LEL function control - self-diagnostic programme when switched on operating conditions -20... +40 C; 15... 95 % RH / protection IP 67 (waterproof ex protection: Ex CE INERIS 02 ATEX 0060 II 1 G EEx ia IIC T4 norm: EN 30079-291: 2007; EN 50271 TETRA-MINI Multi-Gas Meter with ATEX Approval acoustic alarm 95 db (A / visual alarm: LED red and blue vibration alarm / single-button operation graphical display / rechargeable battery and charger included approval: ATEX II 2G EEx iad IIC T4 (T amb -20 +55 C, BASEEFA 03ATEX0193 EN50014, EN50020, EN50018, 94/9/EC TOP seller Model Meas. range Measurement principle GAZEX-UEG 0...100 % vol. LEL methane catalytic combust. (pellistor GAZEX-UEG/Vol.% 0... 100 % LEL LEL catalytic comb. (pellistor 0... 100 % vol. vol thermal conductivity GAZEX-ppm/UEG/Vol.% 0... 10000 ppm ppm catalytic comb. (pellistor 0... 100 % LEL LEL catalytic comb. (pellistor 0... 100 % vol. vol thermal conductivity Sample coll. / method diffusion or hand-operated pump / continuous measurem. Power supply Li-Ion rech. batt. (charging/oper. time:rech. batt.: 15 h/4.5h / case LCD / ABS and elastomer Dimensions / weight 139 x 50 x 28.2 mm / 119 g Gas detector for use in ex zone, charging / configuration station, crocodile clip, lithium battery, instruction manual K-GAZEX-UEG gas meter LEL K-GAZEX-UEG/Vol.% gas meter LEL / vol.% K-GAZEX-ppm/UEG/Vol.% gas meter ppm / UEG / vol.% K-0100-050 hand-held suction device K-0100-018 metal case type 1 144 www.pce-instruments.com/us Gas Meas. range Alarm LEL 0... 100 % 20 % O 2 0... 25 % 19.5 and 23.5 % CO 0... 500 ppm 30 ppm H 2 S 0... 100 ppm 5 ppm Sensor life like Tetra (O 2 approx. 3 years Resp. time like Tetra Alarm like Tetra graphical LCD Memory logger / event recorder PC Interface IR interface Power supply rechargeable lithium ion battery for min. 16 h Oper. conditions -20... +55 C / 0... 99 % RH Dimensions / weight 112 x 72 x 49 mm / 270 g TETRA-MINI, rechargeable battery, charger (without PC interface, instruction manual K-TETRA-MINI 4-in-1 meter with charger (without RS-232 interface K-TETRA-ML charger with RS-232 interface K-TETRA-MRS RS-232 cable for charger K-TETRA-SW software K-TETRA-ASP suction pump set K-CAL-TETRA calibration / maintenance (e. g. every 6 months K-TETRA-INT PC interface Tetra K-TETRA-LS charger Tetra

PCE-AC 4000 Large CO 2 up to 5000 ppm display in A4 format simultaneous indication of CO 2, temperature and RH adjustable acoustic alarm temperature units C and F CO 2 status displayed via coloured LED indicators (green-good / yellow-acceptable / red-bad IAQ Series Indoor Air Quality Meter AVG, MIN / MAX functions NDIR sensor / measures CO 2 in real time (ppm further functions of the IAQ7525 manual / continuous storage (intervals 1s... 1h includes LogDat2 software and connection cable calculates percentage of fresh air on basis of CO 2 measures humidity, dew point & wet bulb temp. PCE-AC 3000 Indoor Carbon Dioxide Meter wide CO 2 measurement range up to 3000 ppm with RJ45 switched output 24 hours data logger function adjustable limit value alarm for CO 2 can be reset to factory defaults acoustic alarm Meas. Range CO 2 0 5000 ppm Accuracy ±75 ppm +5 % of reading Alarm 1000 ppm standard (adjustable Temp. range 0 +50 C Accuracy ±1 C (0 +40 C,otherw. ±1.5 C RH range 10 90 % RH Accuracy ±5 % RH (+25 C, or ±7 % RH CO2 ( 2.3 / 56.8 mm, temperature / RH (0.8 / 20.4 mm Power supply 12 V / 1 A Op. conditions 0 +50 C / <80 % RH Dimensions approx. 300 x 210 x 50 mm Large CO 2 display, mains adaptor, case, instruction manual K-PCE-AC 4000 large CO 2 display Model IAQ7515 IAQ7525 Meas. range CO 2 0... 5000 ppm Accuracy ±3 % of reading or ±50 ppm Temperature - - - 0... +50 C Accuracy / Resol. - - - ±0.6 C / 0.1 C Air humidity - - - 5... 95 % RH Accuracy - - - ±3 % / 0.1 % RH Memory - - - 12700 values Power supply 4 x 1.5V AA batteries Op. conditions probe -10... +60 C Dimensions probe integrated Ø 19 x 283 mm Dim. / weight of device 244 x 84 x 44 mm / 270 g Air quality meter, calibration certificate, (IAQ7525 comes with software & data cable, instruction manual K-IAQ7515 CO 2 meter K-IAQ7525 CO 2 meter with memory K-CAL-IAQ-7515 ISO calibration certificate K-CAL-IAQ-7525 ISO calibration certificate Meas. range CO 2 0... 3000 ppm Resolution 1 ppm (at 0... 100 ppm 5 ppm (at 1000... 2000 ppm 10 ppm (at 2000... 3000 ppm Accuracy ±5 % of reading or ±50 ppm Temperature -20... +50 C Resolution 0.1 C Accuracy ±1% or ±1 C Memory 48 values Power supply 4 x 1.5 V AA batteries or mains ad. Op. conditions +5... +50 C Dimensions / weight 165 x 80 x 23 mm / 600 g Air quality meter, 4 x 1.5 V AA batteries, mains adaptor, instruction manual K-PCE-AC 3000 CO 2 meter 150 www.pce-instruments.com/us

CDL 210 CO 2 & Climate Data Logger measures and displays temperature and air humidity acoustic signal when pre-set CO 2 value is exceeded simultaneous indication of CO 2, temperature and humidity memory: 5300 series of measurements / USB interface wide CO 2 measurement range of up to 2000 ppm RLA 100 Gas Detection System to Detect Carbon Dioxide (CO 2 detects carbon dioxide (CO 2 2 adjustable alarm limits 4-digit digital display continuous visual surveillance possible potential-free change-over contact integrated alarm transmitter can easily be mounted to a wall three system components TOP seller Meas. range CO 2 0... 2000 ppm / NDIR principle Accuracy / resol. 50 ppm ±5 % / 1 ppm (0... 100 ppm Temperature -10... +60 C Accuracy / resol. ±0.6 C / 0.1 C Air humidity 5... 95 % Accuracy / resol. ±3 % / 0.1 % shows all parameters at once Memory 5300 series of measurement values Log data / rate up to 16000; 3 / 10 / 30 s 1 / 3 / 10 / 30 min.; 1 / 3 / 4 h Power supply 5V ac mains adaptor / 0.5 A Dimensions 120 x 100 x 110 mm Data logger CO 2 and climate, mains adaptor, data cable, PC software, instruction manual K-CDL 210 CO 2 data logger Note: Manual calibration should be done on a clear day outside, e.g. on an exterior window sill where the level of CO2 is approximately 400 ppm. Gas detector Sample gas carbon dioxide (CO 2 : 0... 50000 ppm (5 % (vol., NDIR sensor Gas entry by diffusion Alm. contacts 1 potential-free change-over contact to control external devices (NO/ NC for alarm 1; switching capacity: 30 V dc / 250 V ac, max. 2 A Alam limits alarm 1: 0.5 / 1 / 1.5 / 2 % alarm 2: 1.5 / 2 / 2.5 / 3 / 3.5 / 4 % Menu items supervision of device connection, calibration, unit switching, alarm 1, 2 and factory settings 4-digit display for concent. in range ppm; 3 digit display for concent. in range %; LEDs for operation, Alarm 1, 2 y monitoring of voltage supply Safety Continuous self-surveillance, sensor lifetime,unplausible measurement values, EEPROM system, internal data transfer Power supply Adaptor 100... 240V AC, 50/60 Hz Case Plastic, IP 54, splash resistent Op. conditions 0... +45 C Dimensions 168 x 125 x 47 mm (without connections Control unit Power supply via data cable connected to gas detector Op. conditions 0... +45 C Menu items Control connection between the PC measuring the gas and the gas alerter Change from C to F 4-digit indication for content in ppm; 3-digit indication for content in %; additional indication for temperature; LEDs for operation, alarm 1 and 2 and monitoring of voltage supply Case aluminium, IP 54, splash proof Dimensions 118 x 85 x 34 mm (without connections Gas detection system, instruction manual K-RLA 100 gas detection system K-CAL-RLA ISO calibration certificate www.pce-instruments.com/english 151

HFX205 Measuring Device for Formaldehyde short response time / real-time display manual and automatic data storage high-speed USB software for online data transfer no warm-up time necessary automatic backlight self-calibration / limit value alarm Gasman Ozon Ozone meter for personal use (ATEX Adjustable alarm levels; vibration alarm, LED alarm, beeper Can take it into Ex zone / internal security Dust and water resistant IP 65 / 67 LCD screen with backlight Internal calibration via keypad / datalogger function Tetra 5 Gas Meter for Ozone with ATEX ATEX II 2G EEx iad IIC T4 acoustic & visual alarm: 90 db (A / red LED and vibration alarm / case IP 65 protection 128 x 64 pixels graphical display with backlight additional sensors for other gases available can be used in hazardous areas 152 Meas. range 0... 5 ppm Resolution 0.01 ppm Accuracy <±2 % Sensor electrochemical sensor Response time <30 s Calibration automatic self-calibration Memory up to 500 sets of data Interface USB Power supply rech. Li-Ion batt. (3.7 V / 1200 mah ac adaptor 100... 240 V to 5 V dc / 1 A Op. conditions +5... +40 C / <90 % RH Contin. operation 6 h with batteries Dimens. / weight 80 x 36 x 150 mm / approx. 200 g Meas. device, rechargeab. (Li-Ion batt., 230 V charger, USB data cable, softw., calibration cert., manual K-HFX205 formaldehyde measuring device K- measurement range up to 25 ppm K-RHT200 humidity / temperature sensor Meas. range 0... 1 ppm (O 3 Alarm 0.1 ppm Response time 20 s Acoustic alarm 95 dba, several alarm tones Visual alarm gas hazard = LED flashing red / blue Vibration alarm internal vibration alarm transmitter Prot. class case IP 65 / 67 LCD with backlight Power supply Lithium battery Op. conditions -20... +55 C / 0... 99 % RH Dimens. / weight 90 x 48 x 24 mm / 118 g Ozone meter, pocket clip, battery, instruction manual K-Gasman-O3 gas / ozone meter K-CAL-G-N ISO calibration certificate K-SW-G-N software K-RS232-G-N RS-232 data cable K-RS232-USB adaptor RS-232 to USB www.pce-instruments.com/us Meas. range 0... 1.00 ppm (O 3 Alarm 0.1 ppm Response time 10 s Acoustic alarm 90 db (A at a distance of 1 m Visual alarm extra bright LED Protection class IP 65 LCD, with backlight Power supply rechar. Li Ion battery (min. 12 h Operating conditions -20... +55 C / 0... 99 % RH Dimensions 122 x 128 x 57 mm 498 g Ozone meter, rechar. Li Ion battery, charger, manual K-TETRA-5-O gas / ozone meter K-CAL-TETRA ISO calibration certificate K-TETRA-SW software K-TETRA-INT interface for PC K-TETRA-ASP suction pump K-TETRA-TRA shoulder and chest carrying strap