SIL2-Interface/ -Signal Conditioners Series DuoTec

Similar documents
Instrumentation Products and Applications

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

SUPREMATouch. Modular Fire & Gas Detection System

SITRANS T temperature transmitters A broad product family for every application. sitrans

Model 144H. Product Data Sheet , Rev DB February Content

Intelligent addressable fire alarm control panel

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

SUPREMATouch. Modular Fire & Gas Detection System

Safe area; Zone 1 and Zone 2

Nov 08 PRODUCT SPECIFICATION SHEET

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

SUPREMATouch Modular Fire & Gas Detection System

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

Flame Monitors BROCHURE

FUNCTIONAL SAFETY MANUAL

Dräger Polytron 8000 Stationary gas detector (EC)

M-Sens 2. Online moisture measurement for solids. Operating Instructions. SWR engineering Messtechnik GmbH PART OF THE ENVEA GROUP

RS485 MODBUS Module 8AI

Temperature Solutions Line Card

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

designed for rail 5000 Series

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

Pressure Transmitter cerabar S PMC 731/631 cerabar S PMP 731/635 with ma output signal

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

The Next Generation Machine Protection System

EXCELLENCE in Solutions Products Service

Touchpoint Pro Flexible Gas Control System

UDC100 Universal Digital Controller Specifications

FC722 Fire control panel

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

I/A Series 716C 1/16 DIN Temperature Controller

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

EC3-X33 Stand-alone Superheat Controller Technical Data

UDC 700 Universal Digital Controllers and Indicator Specifications

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Differential Pressure Transmitter deltabar S PMD 230/235 deltabar S FMD 230/630/633 with ma output signal

INSTRUCTION MANUAL. Software Revision Card 3.2 DOCUMENT SES-KS E REV. 3

Dew point set DS 400

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Danfoss gas detection unit Type GD Heavy Duty

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

EC3-X33 Stand-alone Superheat Controller

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Proservo NMS5- / NMS7-

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Temperature Measurement Transmitters for field mounting

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

SAFEMASTER PRO. The configurable safety system versatile and extendable. Our experience. Your safety.

Dräger Polytron 7000 Fixed gas detector

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Model 144H. Product Data Sheet , Rev DB February Content

User s Manual. YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters. Manual Change No

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

MODEL 9010/9020 LCD CONTROL UNIT

Datasheet: K-22 LO Sensor

1.7. Insulation fault evaluators EDS460/490 EDS461/491

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

M2500 Engine Controller Installation Manual

Substation Monitoring System

ß-Aerosolmonitor FHT 59 C

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

STEAMPAK Series BurnerPAK BMS Burner Management Systems

For Complete Fire and Gas Solutions

Fire and Gas Monitoring Panel ST7-HV

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Segment design & and Bus Diagnostics

1.7. Insulation fault evaluators EDS460/490 EDS461/491

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Pressure Transmitter cerabar M PMC 41/45 cerabar M PMP 41/45/46/48 with Output Signal ma/hart

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

OVEN INDUSTRIES, INC.

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

ClampOn DSP Pig Detector

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

Assembly. Host Sub-D Alarm

Speed and Frequency Seite 1 von 7

Products and performance

Operating Instructions

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

HTC-915-CONT. Heat-Trace Control system

SECTION Fluorescent Dissolved Oxygen Measuring System

Se vuoi ricevere aggiornamenti e novità compila i tuoi dati - In attesa di iniziare

Process & TeMPerATUre UniversAl input DigiTAl MeTers

SPA 2 IS. IECEx. Programmable Limit Alarm Trips with Intrinsically-Safe Field Connections

FC723 Fire control panel

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Transcription:

SIL2-Interface/ -Signal Conditioners Series DuoTec Certified according IEC 61508/ 61511 SIL2 DIN-Rail- and 19 -Mounting Since 1970 - Mütec Instruments GmbH

Introduction To achieve a maximum safety in production processes, new innovative technologies have to guarantee safety of these processes, in order to note and indicate any disruptions from optimal conditions as soon as possible. With the DuoTec- Failsafe technology developed by Mütec Instruments, these criteria are met by means of self-monitoring security. Additionally measuring accuracy and reliability is increased and lifetime cost of instruments reduced. DuoTec-Failsafe is the only interface worldwide with self-monitoring and has achieved DIN 19250 TÜV-certification according to AK4 and certification according IEC 61508 SIL2. With the experience of more than many 10000 installed systems worldwide during a period of 40 years, we venture to express: With DuoTec your system is in safe hands Application DuoTec-systems consist of the transmitter (MTP200) and the 2-wire-power-supply unit (MSK200). They are the interface between the system (sensors in the field) and the PCS or PLC. The system accepts practically all electrical standard signals (ma, mv, V) and temperature sensors (Pt100, TC). Hazardous area protection to EExia (area 0) is available. Twowire transmitter are supplied directly by the supply unit to EExib (area 1) or EExia (area 0). The systems itself are not installed in an ex-area. Output signals such as 4-20mA or 0-10VDC, 4 limit values and a maintenance accessory relay are available. All information s are available by serial Interface (RS 232/RS 485). The measuring transmitter and the measuring transmitter power supply system include limit switches, thus an separate limit switch card is not necessary. Safety due to request of IEC 61508 SIL2 In addition to standard applications the devices are suitable for fail-safe installations. Fail-safe installations are designed to minimize risk of damage and harm to equipment and personnal by maintaining a safely operation in case of emergency or even controlled shut-down of production line. World-wide applicable safety standard IEC 61508 and IEC 61511, functional safety of electrical/electronic/programmable electronic safety-related systems, require detailed documentation about remaining risk in emergency situations. Remaining risk of a fail-safe function is calculated from failure probability of all connected/ effected components within the electrical loop. Four (4) Safety Integrity Levels (SIL 1 to SIL 4) define the level of safety measure for each plant component. Selecting one of the Safety Integrity Levels also determines limiting value of remaining risk. Most common selection for circuit calculation is SIL 2, rarely is SIL 3 used. Mütec Instruments GmbH was the first company seeking certification for its transmitters and transmitter power supplies. Initial certification was established in 1999 by TÜV Nord according to DIN19250 for class SIL 4. Starting in August of 2004, all devices are now IEC/EN 61508 SIL2 certified. The enhanced certification along with our vast experience from long term installations in a wide array of diverse applications guarantees highest safety and reliable operation. Additional the devices are proven and on the vendor lists of many well known companies.

Continuous self monitoring The principle design in the DuoTec systems consist of two (2) independent microprocessors. These microprocessors continuously monitor themselves and all involved functions while processing measurements. These functions include the measurement circuit, output circuit, power supply circuit, relay contacts, microprocessor hardware, and software. Within 100ms a total of 10 single diagnostic functions are initiated. If any of the diagnostic functions don t pass a plausibility algorithm a service alarm is generated. In any event, a open contact (closed-circuit current) is available for either a safety loop or group alarm. A front-sided red LED visually indicates an alarm directly at the transmitter and is displayed on a connected monitor via our WINSMART software. In case of an intermittant alarm, for instance a loose cable connection, this error is protocoled in the error register and visually indicated by a blinking LED at the transmitter. Since the DuoTec system independently monitors itself routine maintenance is not required. A detailed error description allows for fast and efficient error analysis. In case of an error an automatic procedure to safely shut-down a production line can be initiated. Main benefits Further benefits IEC 61508 SIL2 and TÜV-Certificate according to DIN 19250 AK4 Self monitoring by 2 micro processors with diagnosis manager with error memory 4 limit alarms, 1 service alarm Optional 2 analog outputs Bus-connection (RS 232 and RS 485) and configuration software WINSMART DIN-rail or 19 -mounting Input: multi-functional / power supply Optional for hazardous area protection to Exia (area 0) according to ATEX. Diagnosismanager with analyse of the error and error memory (e.g. for the early recognise of loose connection). That means a routine maintenance or a cost intensive error fault detection is not necessary and ensures a high available plant. 1 error-relays as collection alarm. All devices with 2 free configurable relais and two transistors equipped and for limit monitoring and/or error monitoring applicable. Therefore all DuoTec-devices has the function of limit monitoring. Only 2 types of devices: Universal transmitter MTP for e.g. Pt100, Thermocouple, current, voltage, potentiometer etc. and the power supply MSK for giving supply to 2-wire-sensorsas well as current and voltage input. By means of this multifunctional the DuoTec-Series a stocking up of many transmitters with different inputs and functionalities is not necessary. That means optimal resp. cost effective storage and a maximum amount of flexibility. Front sockets for HART-signal lead through by MSK 200 (optional via analog output). Galvanic separation between input, output and supply and interface as well as 5 galvanic separated alarm outputs (3 * relays, 2 * transistor). All devices for DIN-rail or 19 -mounting with identical functions and a uniform software, so that with the same technology/ function (and software) are different mountings could be used. At the DIN-rail mounting the supply can be carried our via a adapter in between a conventional DIN-rail or alternative via a clamp. Via the adapter a bus connection (RS485-interface can be used as well.

Technical data SMART-transmitter power supply MSK 200 SIL2 MSK 200-E MSK 200-TE Option: iexa Option: SIL2 2-wire-supply system in DuoTec- Technology with self monitoring, isolator Output: 0/4-20 ma, 1-5/0-10 VDC (actual value) Galvanic separation between auxiliary energy, input and output 4 individually adjustable limit values 2 relay contact outputs, 2 transistor outputs, 1 collective alarm relay contact Configuration ON-LINE by means of WINDOWS-WINSMART-Software RS 232-interface on the front panel, RS 485-interface from the multi-pin plug Auxiliary power supply 24 VDC/AC Form of construction: 19, 4TE, 3HE as above, but form of construction: mounting rail, DIN EN 50022, 1 transistor output ATEX II (1) G [Ex ia] IIC IEC 61508 / 61511 SIL2 Technical data SMART-universal measuring transmitter MTP 200 SIL2 MTP 200-E MTP 200-TE Option: iexa Option: SIL2 Universal measuring transmitter in DuoTec-Technology with self monitoring Input: Resistor and Pt100 in 2-, 3- and 4-wire-configuration, all sorts of thermo couples, ma, mv, V Output: 0/4-20 ma, 1-5/0-10 VDC Galvanic separation between auxiliary energy, input and output 4 individually adjustable limit values 2 relay contact outputs, 2 transistor outputs, 1 collective alarm relay contact Configuration ON-LINE by means WINDOWS -WINSMART-Software RS 232-interface on the front-panel, RS 485 interface from the multi-pin plug Auxiliary power supply: 24VAC/DC Form of construction: 19, 4TE, 3HE as above, but form of construction: mounting rail, DIN EN 50022, 1 transistor output ATEX II (1) G [Ex ia] IIC IEC 61508 / 61511 SIL2 Technical data SMART-transmitter power supply with two analog outputs MSK 200-TV2 SIL2 MSK 200-TV2 Option: iexa Option: SIL2 2-wire-supply system in DuoTec- Technology with self monitoring, isolator 2 analog outputs: 0/4-20 ma, 1-5/0-10 VDC (actual value) HART via analog output 1 Galvanic separation between auxiliary energy, input and output 4 individually adjustable limit values 2 relay contact outputs, 2 transistor outputs, 1 collective alarm relay contact Configuration ON-LINE by means of WINDOWS-WINSMART-Software RS 232-interface on the front panel, RS 485-interface from the multi-pin plug Auxiliary power supply 24 VDC/AC Form of construction: mounting rail, DIN EN 50022 ATEX II (1) G [Ex ia] IIC IEC 61508 / 61511 SIL2 Further Technical Data See Manual

Comfortable configuration with WINDOWS-Software WINSMART Systems can be configured and parameters modified from the measure monitoring by means of a Notebook with the RS232-Interface on the front panel or by the RS485-Bus. The Software WINSMART which is WINDOWS based is very clear and easy to operate. All input data like: choice of thermo couples, Pt100, ma-, mv-signal, all output data, limit values, tolerance ranges, measuring accuracy, filter (also on the output) etc. can easily be adjusted by a Mouse click. Even a survey of MIN- and MAX-gradient is integrated in the mask for limit value adjustment. Input or change of data is protected against manipulations by means of an access code. Finding and elimination of errors by means of the diagnosis manager WINDOWS-WINSMART displays the measuring value in analogue and digital forms in an online-mask. If the limit value is exceeded, this is indicated at the system itself and in the software. A permanent monitoring of limit values thus also is guaranteed over great distances. The diagnosis manager integrated in WINDOWS-WINSMART displays current fault and fault memory. Thus it is guaranteed that even short-term errors like intermittent contacts can be localized. Only by Reset fault memory in the diagnosis manager can the error-memory be deleted. A text-memory freely available for user enables a documentation of history of the measuring transmitter and supply system.

Bus-structure

19 -Racks and -Cabinets The DuoTec-devices can be delivered in 19 -Racks and / or cabinets according individual customer requirements.. Cabinets Racks DIN-Rail devices The devices MTP200-TE and MSK200-TE are designed for picking up directly on a DIN rail. Despite the high function density of devices the small form of construction is only 22.5 mm broad. Deductible clamps make a comfortable wiring. More models Beside the DuoTec-Series are more transmitters offered, which are certified according to IEC 61508/ IEC 61511. Moreover Mütec develops Hard- und Software according to customer requests and licensed with appropriate certificates. MTP300i-SIL MTP300d-CJC

Service Our Service: Individual developments of Hard- and Software also under consideration of certificates like ATEX, SIL, etc. and quality requirements Customized versions Individual consulting Pin-compatible 19 -devices Customized racks and cabinets Putting into operation Repairs of 19 - and DIN-rail devices Certificates Mütec Instruments GmbH Bei den Kämpen 26 D-21220 Seevetal-Ramelsloh GERMANY Tel.: 04185 80 83 0 Fax: 04185 80 83 80 Email: muetec@muetec.de Web: www.muetec.de DuoTec und WINSMART sind eingetragene Warenzeichen der Firma Mütec. Änderungen jederzeit vorbehalten.