Instruction Manual for P-2063 Nuclecel Ionizer & Accessories

Similar documents
Instruction Manual P-2021-Z705

Eliminators. Advanced Ionization Technologies

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual

OPERATION INSTRUCTION

IONIZING AIR BLOWER INSTRUCTION MANUAL

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

Guardian CR2000 Overhead Ionizing Air Blower. User s Manual

Air Paper Jogger AJ-700 Operation Manual. Keep this manual at hand where it can be referenced at any time.

TA-12. Tabbing System USER'S GUIDE

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

CA3500, BA3500, CH3500 New Comfort

THE MONTICELLO CEILING FAN INSTALLATION INSTRUCTIONS

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

INSTALLATION, OPERATION AND SERVICE MANUAL MIGHTY ION MODEL MI SERIES

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

Eagle 2500 TM OWNER S MANUAL. Electronic Air Purification 110 and 220 volt Systems. EcoQuest International. Application.

WARNING Important Safety Information

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

Rainsoft Division of Aquion, Inc East Lunt Avenue Elk Grove Village, Illinois or

XPS-ProDry User s Guide Dryer Base

ACQUITY UPLC HT Column Heater Instructions

Nuclear Associates

Critical Environment Ionizing Blower. Model 5810i. User s Manual

RLD-H10G Refrigerant Leak Detectors

ELIMINOSTAT DC-ESR-CL-S2

H-10PM. Refrigerant Leak Detector

LAKEWOOD INSTRUMENTS MODEL 353 ORP/MILLIVOLT CONTROLLER

RLD-H10P Refrigerant Leak Detector

OPERATION & MAINTENANCE MANUAL MODEL SC SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Operation/Maintenance BLOWER OVERHEAD Ionizing Air Blower

FD Heavy Duty Feeder for FD 280 Tabbing System

Model & Replacement Pre-Filter Information Model Pre-Filter F Hunter Fan Company

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

PLEASE READ CAREFULLY THE INSTRUCTIONS BEFORE OPERATING

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Owner s Manual Phoenix 1200 Desiccant Dehumidifier

FT982. Electric Professional Fogger. CAUTION: Read and follow all instructions

WARNING Important Safety Information

ORP/MILLIVOLT CONTROLLER

USER INSTRUCTION MANUAL SAPPHIRE SERIES 1100 & 1100EC

CD85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

teambrite Supply Steambrite Supply Created on: : Monday 01 October, 2018

Modular Island Grill - Refrigerator Module

Eldex Column Heater. Operator s Manual

Service Manual Model 3163

DRI-AIR INDUSTRIES, INC. AHM-1C HOPPER MOUNT DRYER OPERATING MANUAL

e Bath Fan with Light User s Guide

DRI-AIR INDUSTRIES, INC. AHM-1B HOPPER MOUNT DRYER OPERATING MANUAL

BK17 Heater. Read all instructions before using the heater. Contents

3M Overhead Ionizing Blower 991A

Chargebuster Ion Gun Installation, Operation and Maintenance

AIR CLEANER A GUIDE TO OPERATING AND MAINTAINING YOUR ELECTRONIC. NOTE TO INSTALLER: This manual should be left with the equipment owner.

Component. Maintenance. Manual Z SERIES. Evaporator Assembly

Measurement Devices. Topic 5 - Audio 56

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

14" - 24" CLASSIC Direct Drive Fans

READ AND SAVE THESE INSTRUCTIONS

7251DH Intelligent Air Duct Smoke Detector

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

34737-TL SMD REWORK STATION

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

AIR PURIFIER CLASSIC INSTRUCTION MANUAL. CAUTION: Read manual carefully for correct procedures and proper operation.

WARNING Important Safety Information

Static Electricity: Causes and Cures in Web Converting Presented By: Matt Fyffe

PrecisionTemp Shower-Mate

IMPORTANT SAFETY INSTRUCTIONS

Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL

Locally Controlled Bug Killers. Read all instructions before using the bug killer. Contents

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP

Chargebuster Overhead Ionizer Installation, Operation and Maintenance

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

Burn Easy Installation Instructions LP or Natural Gas Fired Units. Cremator Setup:

IMPORTANT INSTRUCTIONS READ & SAVE

ph COOLING TOWER CONTROLLER

A/C-HEATER SYSTEM - MANUAL

Electronic Air Cleaner Model Number CSC1000 OWNER S MANUAL. Installation Operation Basic Service Guide Technical Repair Guide Repair Parts

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Natural Mist Humidifier. Vicks. (Model V3500) IMPORTANT! READ AND SAVE THESE INSTRUCTIONS. Use and Care Manual

DRI-AIR INDUSTRIES, INC. HA750B B HOT AIR DRYER OPERATING MANUAL

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

V. (Versus ) Bare Floor Vacuum

DH100ACDCI Ionization Air Duct Smoke Detector

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

e Bath Fan with Light User s Guide

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

CAUTION signals a situation where minor injury or product damage may occur if you do not follow instructions.

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

BOLT ION 2-IN-1 CORDLESS VACUUM USER GUIDE REMANUFACTURED 1312R. For How-To videos, go to

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

Safety, Operation and Maintenance Manual with Parts List

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Transcription:

NRD, LLC 2937 ALT BOULEVARD PO BOX 310 GRAND ISLAND, NY 14072-0310 800-525-8076 716-773-7634 716-773-7744 FAX e-mail: sales@nrdinc.com website: www.nrdinc.com Instruction Manual for P-2063 Nuclecel Ionizer & Accessories CONTENTS 1.0 Introduction Page 1 1.1 Our Thanks 1.2 Other NRD Products 1.3 Customer Support 2.0 General Information Page 2 2.1 Safety of NRD Devices 2.2 Lease Agreement 2.3 Return of Expired Devices Page 3 3.0 Model P-2063 Nuclecel Ionizer 4.0 Accessories Page 4 4.1 Model 4064 Fan 5.0 Troubleshooting Page 5 APPENDIX Data Sheet/Specifications Page 6 Safety Brochure INST2063 6/14

1.0 Introduction Since 1969, NRD has produced ionizing radioactive sources that are used in static control, smoke detectors, physics research, space exploration, and instrumentation. NRD is the world s largest and one of the oldest suppliers of radioactive metallic foils. Specially designed equipment and facilities enable us to produce a sealed source device that is safe and is highly effective in eliminating static. 1.1 Our Thanks Thank you for choosing NRD for your static control needs. You have chosen a highly effective static eliminator device that is reliable, requires no calibration, and is safe. Please review the information in this manual to maximize the benefit of NRD s In-Line Ionizers. 1.2 Other NRD Products NRD offers static eliminator devices and accessories to eliminate or control electrostatic charges. The many product configurations we offer will fit a wide field of applications. Just call us with your application and we can provide a solution. The electronics industry uses air ionizers to reduce product damage and loss. Application of ionizers in the printing, converting and graphics industries allow in-process cleaning of product and faster process speeds. Higher productivity, better quality, and enhanced reliability help make your company a success. Here is the range of products we offer: Nuclestat Bars offered in lengths of 4 to 142. Nuclecel In-Line Ionizers for parts blow-off and surface preparations. Nuclespot Ionizer provides focused concentration of ions to the product. Tabletop Blowers for electronic assembly. Detailed data sheets and informational notes are available upon request. Consult the main catalog for listing. 1.3 Customer Support Toll Free Number 1-800-525-8076 8:00 AM 5:00 PM Eastern Time (M-F) General Listing 1-716-773-7634 Fax Number 1-716-773-7744 Page 1 INST2063-6/14

2.0 Important Information All radioactive devices using Polonium-210 are leased for one (1) year. It is important to keep track of these units so that they can be returned to NRD for proper disposal. If the device is misplaced, please call NRD for information on how to report the lost device. 2.1 Safety of NRD Ionizers The radioactive material (Polonium-210) is 100% encapsulated using a pressure welded metallurgy technique. The result is an encapsulation that is insoluble and inert to most chemicals. Vibration and impact normal to industrial applications will not adversely affect product integrity. The alpha particles come from the natural decay of the radioactive source and collide with air molecules to create ions. However, alpha particles are unable to penetrate a thin piece of paper or human skin! Complete safety is ensured when the ionizers are used in accordance with normal mounting and operating conditions. Normal use and conditions of the ionizer include: Temperature not to exceed 212 F (100 C). Use air, nitrogen or an inert gas. You can safely handle the outside of cell. Do not insert any object or attempt to clean the inside of the cell. Mount the ion cell in a normal way by using the mounting posts of the ion cell. Do not alter the ionizer in any way, i.e. drilling holes. Contact us for mounting options. Review the enclosed Safety Brochure for a more detailed description of how the ionizers work, where they are typically used, and the general safety of NRD ionizers. 2.2 Lease Agreement All ionizers containing Polonium-210 are leased, not purchased. The devices are leased for two main reasons: 1.) Federal Regulations state that the device must be tested for radiation leakage prior to shipping and before 13 months from the date of manufacture. NRD performs these leak tests and provides you with a Leak Test Certificate as documentation. 2.) The activity of the ion cell decreases over time. At the end of 12 months, the cell needs to be replaced (or renewed) in order to maintain its effectiveness. NRD will notify you when it is time to renew the device. To renew the lease when the device reaches its 12 month expiration (the manufactured date is printed on the label of device), simply provide us with a new purchase order to make the original lease valid for another 12 months. Upon delivery of the renewed device, remove the old cell from service and ship it back in accordance with the Return Shipping Instructions. Page 2 INST2063-6/14

2.3 Return of Expired Devices Expired P-2063 Ionizer (12 months or older) can be returned to NRD for proper disposal according to Return Shipping Instructions on page 6 of this manual. A Return Authorization (RA) is not required prior to sending a device back for disposal. 3.0 P-2063 Nuclecel Ionizer The P-2063 Nuclecel Ionizer is used to neutralize static electrical charges in static sensitive operations. The Ionizer is normally placed in an atmospheric pressure air stream so that the airflow delivers ions generated by the Ionizer to the work area. Charged parts that are placed in close proximity to the ion cell can also be effectively neutralized without the need of air movement. 3.1 Installation & Operation A. One common method to install the P-2063 Nuclecel Ionizer is by using spring clips that will snap on to the posts of the Ionizer. The spring clips can be attached to a mounting base. There are other methods to mounting the cell, but cannot involve modifying the Ionizer. Do not alter the P-2063 Nuclecel in any way that may compromise the integrity of the source. Do not drill holes, grind or file, tap holes, etc. to the P-2063 Nuclecel. B. Supply air movement through the ionizer to move the ions to the charged part. A blower, fan, or compressed air/nitrogen can be used. For parts that can be placed in close proximity (1 ) from the grill openings, air movement may not be needed to effectively neutralize the charged part. Page 3 INST2063-6/14

4.0 Accessories 4.1 Model 4064 Ionmaster II Fan The Model 4064 Ionmaster II Fan is used to create airflow through the Ionizer (model P-2063 Nuclecel ). This system delivers a high volume of ionized air to reduce charge on parts. The Fan is mounted on a swivel base and can be placed on a flat surface or bolted to a rigid surface. Procedure to install a new P-2063 Nuclecel Ionizer: A. Unplug the power cord before opening the fan assembly. Remove the two (2) phillips head screws located on the backside of the fan. B. Remove the front housing of the fan. C. See the below diagram showing the installation of the P-2063 Nuclecel Ionizer. Snap in the Ionizer by aligning the Ionizer posts with the spring clips. The orientation of the Ionizer does not matter since it is symmetrically designed. Spring Clips Front Housing two (2) phillips head screws P-2063 Nuclecel Ionizer D. Re-assemble the front blower housing and tighten the two phillips head screws. Tightening the screws will secure the ion cell inside the fan assembly. E. Position the Fan Assembly to direct air where it is needed. The airflow is directed up and down by loosening (counterclockwise) the two black knobs, repositioning, and retightening the knobs to secure fan position. F. Plug the power cord into a 120 VAC grounded outlet. Turn on the power switch located on the top panel. Page 4 INST2063-6/14

Maintenance The only maintenance required is the annual replacement of the Ionizer to ensure maximum effectiveness of the ionizer. It is required to return the expired device to NRD for proper disposal. Calibration is not required. 5.0 Trouble Shooting Guide Symptom Probable Cause Corrective Action 1. Static charges are not eliminated Ion cell may be out of date and need replacement. Possible oil contamination of ion cell. Ions generated are being recombined before they reach the charged surface. Call NRD for Ion Cell replacement. Return cell to NRD for evaluation. Do not attempt to clean the device. Position the fan closer to the charged part. 2. Fan does not turn on No power. Blown fuse internal to fan. Check outlet and breakers. Check for visible damage to power cord. Return fan to NRD for evaluation. Page 5 INST2063-6/14