Important safety information

Similar documents
LAYOUT BRAEMAR ECOSTAR GAS SPACE HEATER AND WALL FURNACE OPERATING INSTRUCTIONS FOR MODELS SH18, SH25 AND WF25 HEATED AIR OUTLET HEATER CONTROL PANEL

Spectrolink Comfort Control. Home Owner's Manual Heating

HOME OWNER S MANUAL DUCTED GAS HEATER. (with MagIQtouch Controller)

HOME OWNER S MANUAL. Spectrolink Comfort Control - Heating

GAS DUCTED HEATER TB SERIES

Spectrolink Comfort Controller. Home Owner's Manual Heating. baby, outside. Come home to ECOST R

Rapid Response Series (RR e & RR i) OPERATING MANUAL

BOSCH CONDENS 5000W ZSB18-2A

HOME OWNER S MANUAL DUCTED GAS HEATER. (with MagIQtouch Controller or Manual Thermostat)

Rinnai. Rinnai GAS SPACE HEATERS. Convector 417 Unflued Room Heater CUSTOMER S OPERATING INFORMATION AND INSTALLATION INSTRUCTIONS

Auto Drain Installation Instructions.

Owner s Guide and. Gas Continuous Flow Water Heater 27L Gas Water Heater 874 & 872 Series, 627 Models

Auto Drain Installation Instructions.

USER GUIDE VOGUE MAX SYSTEM

CERT 7795 Fully certified to AS2658:2008. Part No. COMP825 OWNERS MANUAL

User Guide - Australia and New Zealand EF Outdoor Gas Fireplace. For the latest documentation, visit _6

WARMCAIR. Condensing Air & Water Heater. High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS

User's Instructions. Alpha CB50

Control Panel User Guide

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

Operation & Installation Manual

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces

Owners Manual OWNERS MANUAL. Australia s original Outdoor brand. Part No. Comp830Li. SAI Global Cert. SAI AS

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

TO DO IF YOU SMELL GAS

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

2.4kW Ceramic Heater Model: DHCER24SW

Owner s Guide and Installation Instructions

Operating instructions

Energysaver Space Heaters Models: RHFE-309FT & RHFE-559FT Operation and Installation Manual

USERS GUIDE 24, 30. For installation guide see reverse of book

User s Information Manual

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user

Osprey 2 CFL

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Read installation manual prior to installation of this appliance! Read user manual before putting this unit in operation!

Operating instructions

OWNER'S GUIDE. Gas Continuous Flow Water Heaters. Owner's Information Warranty

by PRIMUS Portable Buddy Compact Propane Heater User Manual and Product Specifications

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Emberglow COAL EFFECT BALANCED FLUE GAS FIRE

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

Operation / Installation Manual

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ

Dyna-Form Air. Alternating Pressure Relief Overlay System

USERS GUIDE. LOGIC+ Combi 24, 30, 35

DOMESTIC HOT WATER Follow operational sequence

User and Installation Instructions C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100

GAS FIRE USER GUIDE Australia and New Zealand. EF _ 5 Userguide Aus & NZ

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios.

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

Version 1.03 January-2002 USER S MANUAL

Operation guide Evolve 950

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

LABORATORY ILLUMINATED FLOTATION BATH

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Operating instructions

User guide Billi Quadra & Quadra Plus Tap options XL, XT, XR

The guarantee on this appliance is valid for 12 months from the first day of installation.

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

User and Installation Instructions. Electric Auto-Fill Water Boilers EB3F, EB4F, EB6F, EB6TF IS339 ECN3539

A Beginners Guide to Inner Range Systems

USER GUIDE LOGIC HEAT H

INSTALLATION AND OPERATION MANUAL TURBO CONVECTION OVEN TCO85

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

Figure 10 or Figure 6

Maximiser SE. USER S INSTRUCTIONS Natural gas only INSTALLER: TELEPHONE:

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Operating instructions Page 12

/2005 GB(EN) For the user. Wall-mounted condensing gas combi boiler Buderus /C, /C

Open Vented Condensing Boilers

New Power Vented Rheem FVIR Tanks

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Settings and Maintenance of the CombinAir

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

WIRELESS WATER CONTROLLER. MC-503RC Installation and Operation Manual

Baxi Maxflow Combi FS

GECE cm touch control ceramic hob. GECE cm touch control ceramic hob

OPERATION & INSTALLATION MANUAL Power Flued Flamefire Gas Space Heaters RHFE-951ETR & RHFE-1250ETR

Operation Manual Portable Room Air Conditioner Models: RPC35WA and RPC41WA

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

Instruction Manual. Please read these instructions and the Safety section carefully before using your refrigerator.

OWNER'S GUIDE. Gas Continuous Flow Water Heaters. Owner's Information Warranty

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

User guide Billi B-6000 Tap options XL, XT, XR

OPERATING INSTRUCTIONS

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle!

INSTRUCTION FOR THE USER THC V E OIL BLU

OWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES)

Logic+ Combi

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Technical

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

Transcription:

LAYOUT

Contents Section Page Operating the heater 2 Heater control panel functions 2 Turning the heater ON 2 Turning the heater OFF 2 Adjusting the room temperature 3 Selecting ECO mode 3 Locking the controls 3 Normal heater operation 4 Caring for your heater 5 Cleaning 5 Maintenance 5 If your heater stops working 5 Problem - potential cause/check 5 Fault messages 6 Important safety information - THIS SPACE HEATER MUST BE INSTALLED AND SERVICED BY AUTHORISED PERSONNEL ONLY. - DO NOT: Operate this appliance before reading these instructions. - DO NOT: Place articles on or against this appliance. - DO NOT: Use or store flammable materials near this appliance or its flue terminal. - DO NOT: Spray aerosols in the vicinity of this appliance or its flue terminal while it is operating. - DO NOT: Operate this appliance with any parts removed. - DO NOT: Modify this appliance. - It is recommended that a flue guard be fitted where children may be able to touch the flue terminal - flue guard part No 079073. Page 1

Operating the heater HEATER CONTROL PANEL FUNCTIONS Child lock indicator Set temperature indicators Eco mode indicator Up button On/off button e e Down button Turning the heater ON Press the ON/OFF button. The set temperature indicators illuminate red to show the set temperature. If the room temperature is below the set temperature the heater will start. During the start sequence you will hear the combustion fan, spark and gas valve opening. A short time after the burner ignites, the room fan will start. Turning the heater OFF Press the ON/OFF button. The set temperature indicators will switch off. The room air fan will continue to run until the heater has cooled sufficiently. Page 2

Operating the heater Adjusting the room temperature with the heater turned on Selecting ECO mode Activating CHILD-LOCK Increase set temperature: Press the UP button to increase by 1 step. Decrease set temperature: Press the DOWN button - each press drops the temperature setting by 1 step. Approximate temperature settings are: - Minimum: 16 o C - Maximum: 28 o C Press and hold the DOWN button for 3 seconds. The "eco" indicator will glow green to show that "eco" mode is active. In "eco" mode the heater will run only at low gas rate or turn off when the room reaches the set temperature - it will not run at high gas rate. To exit "eco" mode press and hold the DOWN button again for 3 seconds - the green "eco" indicator will go out. Press and hold the UP button for 3 seconds. The "child lock" indicator will glow orange to show that the controls are locked. When the "child lock" is active all functions other than OFF are locked. If the heater is turned off while "child lock" is active, it cannot be turned back on until you exit "child lock". To exit "child lock" press and hold the DOWN button again for 3 seconds - the orange "child lock" indicator will go out. Page 3

Normal heater operation Start Run - Heater turned on. - Heater performs check of safety systems. - Combustion fan starts. - Igniter sparks and gas valve opens. - Burners ignite at low gas rate. - Room fan starts approximately 15s after ignition. - Heater continuously checks room and set temperatures, and monitors all safety systems. - Room temperature well below set temperature: - High gas rate and room fan speed. - Room temperature just below set temperature: - Low gas rate and room fan speed. - Room temperature reaches set temperature: - Heater turns off. - Set temperature can be adjusted by pressing up or down buttons. - ECO mode can be selected by pressing and holding DOWN arrow for 3 seconds - green indicator ON. - CHILD LOCK can be selected by pressing and holding UP arrow for 3 seconds - orange indicator ON. - Steam may be visible around flue terminal on cold days - this is normal for high efficiency appliances. - If a fault is detected the heater will shut down and attempt a reset. If a reset is not possible the heater will display an error message (see page 6). Shut down - Heater turns off - Burners turned off - Room fan runs on high then low to cool heater - Run-on time at each speed depends on actual burner high and low on times Page 4

HEATER IDENTIFICATION HEATER INSTALLATION Installation date: Installer: Installer phone No: HEATER WARRANTY AND SERVICE Warranty and service: 1300 650 644 Sales: 1300 650 141 Before requesting a service call please run through the simple checks in the "If your heater stops working" and "Fault messages" sections of this manual. Seeley International Pty Ltd has a policy of continuous product development and therefore reserves the right to make changes to these specifications without notice. Whilst every care has been taken to assure the accuracy of the data compiled in this document, Seeley International does not assume any liability for errors and/or omissions. Braemar is a registered trademark of Braemar Industries Pty Ltd. Seeley International Pty Ltd ACN 23 054 687 035 Albury manufacturing plant Manual part No: 634173-B

Caring for your heater Cleaning Use a damp cloth to wipe over the front cover and the inlet and outlet louvres. DO NOT use solvents or abrasive cleaners as they may damage the surface. Maintenance Energy Safe Victoria recommend annual servicing/maintenance of all gas appliances. To arrange routine seasonal maintenance, please contact an authorised Braemar service agent on 1300 650 644. If your heater stops working If your heater stops working, it is recommended that the following simple checks be carried out prior to requesting a service call - this may avoid an un-necessary service charge. Problem No indicator lights. Can't turn on. Burner does not ignite. Room too slow to heat up. Potential cause/check - Check heater is plugged in and power point is switched on - press ON/OFF. - Check CHILD LOCK is turned off. - Check/increase set temperature. - Gas turned off at gas meter - if turned off contact installer or gas supplier. - Air in gas line - installer to check/purge gas line. - Check ECO mode is turned off. - Check doors and windows are closed. - Check that heated air outlet is clear, move furniture well away from front of heater (3m). - Check/increase set temperature. Page 5

Fault messages Your Braemar Ecostar space heater uses inbuilt fault diagnosis software to help determine the source of a fault. If the heater detects a fault the heater will turn off and the control panel indicators will flash to indicate the fault code (FC) and the reset action required. Please quote this fault code if requesting a service call - this may enable the problem to be fixed over the phone. - Red indicators flashing show fault code. - Green indicator flashing - USER RESET - press and hold ON/OFF button until indicators go off. Press ON/OFF button to turn heater back on. - Orange and green indicator flashing - SERVICE RESET - service call required. FC Indicator flashes Potential remedy 1 User reset. 2 Check flue terminal is not obstructed. User reset. 5 7 9 10 11 12 13 15 19 Service call. Check gas is turned on. User reset. Service call. Check inlet and outlet louvres are not obstructed. User reset. User reset. User reset. Check flue terminal is not obstructed. User reset. Check inlet and outlet louvres are not obstructed. User reset. Service call. GREEN RED ORANGE If a fault is repeated after a USER RESET or after switching the power to the heater off and back on a service call may be required. Page 6

A BRAEMAR ECOSTAR GAS SPACE HEATER OPERATING INSTRUCTIONS FOR MODELS SH18 AND SH25 HEATER CONTROL PANEL ROOM AIR INLET HEATED AIR OUTLET