Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

Similar documents
MODEL 7000 SUCTION UNIT

LoveGo. Portable oxygen concentrator Your Second Doctor. Table of contents. Lovego, let s go along with love. DO what you want to do

MaxiCompressor. evo. High Performance 50 PSI Compressor TH PLACE ADEL, IOWA 50003

MaxiCompressor. Limited Warranty. High Performance 50 PSI Compressor 501-S

SAVE THESE INSTRUCTIONS

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

USER MANUAL SAVE THESE INSTRUCTIONS

SUCTION PUMPS CareLinc Home Medical Equipment and Supply, LLC SS170CE00101

CONSTANT SUCTION UNIT

HERCULES (110V) (220V) USER S MANUAL

ASPIRE Laboratory Aspirator

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

DELUXE ALTERNATING PRESSURE SYSTEM USER GUIDE

DEHUMIDIFIER. User Manual 50BT, 70BT

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

User Manual. 40 Tower Fan MODEL: WFTR40W

Margo Moo TM and Digger Dog TM Steam Inhaler Guidebook

10 Table/Wall Mount Fan Model No: FTY-25 Operating Instructions FTY Soleus Air International

20 High Velocity Fan with 135 Tilt Head

WA A Aqua Sub Bottom-load Water Cooler

Portable Dehumidifier with Internal Pump

Portable Dehumidifier

COOL MIST HUMIDIFIER USER MANUAL FOR MODEL: PAU1. Your Source for Home Comfort

PORTABLE DEHUMIDIFIER

P.N User Manual STAINLESS STEEL ELECTRIC KETTLE 5964/5965 Series MODELS

ELECTRIC KETTLE Model BVSBKT1703 Series. User Manual. QUESTIONS? COMMENTS? IN CANADA: P.N Rev.A

Table of Contents. English

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

18 INCHES, OSCILLATING STAND FAN

Outdoor Refrigerator USER S MANUAL

OWNER S MANUAL FOR ASPIRATION / FILTRATION VACUUM SYSTEM MODELS: 2511 & 2515

Manual Parts Washer. Operating Instructions & Warranty Information

Cool Mist Ultrasonic Humidifier

Ui REFRIGERATOR SPEC SHEET

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

PLEASE READ BEFORE USE AND SAVE. Ultrasonic. with Ionization. INSTRUCTION MANUAL MODEL HUNi

16 Stand Fan with Remote Control Model No: FS3-40R-30

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

PIPELESS WHIRLPOOL FOOT BATH OWNER S MANUAL. Model: FB2-S115

Ultrasonic Humidifier

IMPORTANT SAFEGUARDS

Xaact Spot. Xaact Hot Spot

MINI ELECTRIC CONVECTION HEATER

Owner s Manual Window Air Conditioner

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

CORDLESS GLASS ELECTRIC KETTLE WITH BONUS TEA INFUSER

FIREPLACE HEATER FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R

User Manual. Wine Cellar

ELECTRIC FIREPLACE OWNER S MANUAL

INSTRUCTIONS FOR OPERATION AND CARE OF

FOR THE FOLLOWING MODELS: If you have any questions about the operation of your ultrasonic humidifier, please contact Crane Customer Care.

ELITE (110V) (220V)

PORTABLE AIR CONDITIONER OWNER S MANUAL

P.N ELECTRIC KETTLE User Manual Series MODEL BVSTKT308

HI Industrial Utility Heater HI Soleus Air International

User Manual. Juice Extractor MODEL: WJE2BSLA

Outdoor/Commercial Refrigerator USER S MANUAL

IMpORTANT SAFETy INSTRUcTIONS

CERAMIC HEATER MODEL # EE If you have any questions about the operation of your ceramic heater, please contact Crane Customer Care.

PERSONAL CERAMIC HEATER

R100 Oil-Less Refrigerant Recovery Unit

English. Your Model Number is: HD1500 IMPORTANT

- Oscillating Table Model Fan

Tower Fan MODEL# EE-5607

P.N Rev A ELECTRIC HOT WATER DISPENSER User Manual BVSTWD7915 Series MODEL

ULTRASONIC humidifier

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

Instruction Cum User Manual For EUROLITE

CERAMIC TOWER HEATER

Service Centers: Conair Consumer Products Inc. 156 Parkshore Drive. Brampton, Ontario L6T 5M1

PORTABLE AIR CONDITIONER OWNER S MANUAL

Spa Control System OWNER S MANUAL

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

CERAMIC FAN HEATER MODEL # EE If you have any questions about the operation of your ceramic heater, please contact Crane Customer Care.

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

RJ11-17-TI CORDLESS GLASS ELECTRIC KETTLE. CUSTOMER SERVICE:

USE & CARE INSTRUCTIONS

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

Digital Heat Block User Manual

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

ELECTRIC CONVECTION HEATER WITH FAN AND TIMER

Model CWA200 Owner s Manual

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-12 Task Force Pneumatic Portable Dental System

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

AUTO SPEED BLENDER INSTRUCTION MANUAL MODEL: BLCLMB1

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

1 GALLON / 3.78 LITER ULTRASONIC HUMIDIFIER

Instruction Manual. Compact Portable Ice Maker. Wards.com Enjoy cold, refreshing ice in just 13 minutes

GL-DEH Series Portable Dehumidifier Operating Instructions

BASEBOARD MICATHERMIC HEATER

User Manual ELECTRIC KETTLE Manual del Usuario HERVIDOR ELECTRICO. MODEL/MODELO BVSTKT7098 Series.

Stand Fan. English. Owner s Guide. Model F R

PERSONAL COOL MIST ULTRASONIC HUMIDIFIER

Model # VWK-2 INSTRUCTION MANUAL

Transcription:

S168-544-OO1E REV.A Schuco byallied MEDICAL ASPIRATOR MnrInI -33OA USER'S MANUAL A Caution Federal law restricts this device to sale by or on order of a physician, or any other practitioner licensed by the law of the State in which he practices to use or order the use of this device. A NOTE Check ALL parts for shipping damage. If shipping damage is noted, DO NOT use. Contact medical equipment provider for further instruction.

Index 1. Safety -Information 2 2. AC Power Source...3 3. Electrical...3 4. Introduction...4 5. Illustration of Important Parts...5 6. Set-Up...6 7. How to Operate Your Schuco S330A Aspirator...6 8. Cleaning Instructions...9 9. Maintenance...10 10. Troubleshooting...12 11. Specifications/Classifications...13 12. Warranty...14 1.

1. SAFETY INFORMATION When using electrical products, especially when children are present, basic safety precautions should always be followed. Read all instructions before using. Important information is highlighted by these terms: LbS DANGER Urgent safety information for hazards that will cause serious injury or death. zi\ WARNING Important safety information for hazards that might cause serious injury. CAUTION Information for preventing damage to the product. LbS NOTE Information to which you should pay special attention. READ ALL USER'S MANUAL BEFORE USING. LbS DANGER To reduce the risk of electrocution: 1. Do not use while bathing. 2. Do not place or store product where it can fall or be pulled into a tub or sink. 3. Do not place in or drop into water or other liquid. 4. Do not reach for a product that has fallen into water. Unplug immediately. WARNING To reduce the risk of burns, electrocution, fire or injury to persons: 1. Close supervision is necessary when this product is used by, on, or near children or invalids. 2. Use this product only for its intended use as described in this guide. 3. Never operate this product if: a. It has a damaged power cord or plug. b. It is not working properly. c. It has been dropped or damaged. d. It has been dropped into water. 4. Return the product to an authorized S chuc o S330A medical equipment service center for examination and repair. 5. Keep the power cord away from heated surfaces. 6. Never use while drowsy or asleep. 2

A SPECIFIC WAkkINGs TO REDUCE THE RISK OF ELECTRICAL SHOCK OR INJURY TO PERSONS, DO NOT DISASSEMBLE THIS UNIT. Disassembly or attempted repairs if accomplished incorrectly can create electrical shock hazard. Only qualified technicians should perform servicing of this suction unit. ZN DANGER S330A Aspirator is a vacuum suction device designed for the collection of nonflammable fluid materials in medical applications only. Improper use during medical applications can cause injury or death. For all medical applications: 1. All suctioning should be done in strict accordance with appropriate procedures that have been established by a licensed medical authority. 2. Some attachments or accessories may not fit the tubing supplied. All attachments or accessories should be checked prior to use to assure proper fit. 2. AC POWER SOURCE A CAUTION The S330A Aspirator is designed for operation with an AC power supply (115 VAC, 60 Hz). However, the correct power source must be verified before connecting to wall power. 3. ELECTRICAL Compressor: If the overload protector shuts off the motor frequently; you may have a low voltage situation. Low voltage can also be suspected when: 1. The motor does not get up to full power or speed. 2. Other motor operated appliances fail to operate properly. Too many motor operated appliances on same circuit. A NOTE The motor of this compressor has a thermal overload protector. If the motor overheats, the overload protector will shut off the motor. If this occurs, turn the ON/OFF switch to the OFF position and allow the motor to cool (approximately 5 minutes). Restart compressor. If the compressor fails to start, wait an additional 5 minutes before attempting to restart. If this fails, inspect the fuses on your suction unit. If the unit still does not restart, call your medical equipment provider immediately.

ZN WARNING Proper operation of this product is necessary to avoid physical harm. Improper use can cause personal injury and/or tissue damage. This product should not be used unless the operator has been instructed by a physician or other qualified health care professional. 1. Familiarize yourself with this unit. 2. Place unit on a level table. 3. Before plugging power cord into electrical outlet, check if the ON/OFF switch is in the "0" OFF position. ZN NOTE Before attempting to start a cold unit, let the unit reach room temperature in a heated area. 4. INTRODUCTION The 5330A Aspirator is a professional medical suctioning device that produces a maximum vacuum of 560 mmhg. The unit is equipped with an 800 ml collection bottle that has been designed for convenient and reliable use. Features: New anti-bacteria filter design helps prevent contamination. High quality vacuum regulator and anti-vibration vacuum gauge setting. Oil-less, permanent lubrication. Collection bottle with overflow protection. Designed for superior performance and high reliability in continuous operation. Easy carry and easy cleaning. Following the recommended operating and maintenance procedures outlined in this user's manual will maximize the life of this product. Refer to the diagrams on page 6.

S. ILLUSTRATION IMPORTANT PARTS MODEL: S330A 1. Vacuum Adjust Knob 2. Vacuum Gauge 3. Bacteria Filter 4. Connection Tubing 5. Patient Tubing Connector 6. Patient Tubing 7. 800cc Collection Bottle 8. Canister Bracket 9. Base 10. Power Switch 11. Power Cord 12. Fuse Figure 1 t-igure i

6. SET-UP 1. Attach either end of the connecting tubing (item# 4) to the vacuum port of collection bottle, and then connect the other end to the bacteria filter making sure the filter side marked "FLUID SIDE" is toward the container. 2. The patient tubing should be connected to patient port of the collection bottle at the outlet labeled (patient). Please assure that all connections are secure and without leaks before using. 7. HOW TO OPERATE YOUR Schuco Aspirator 1. Before use, check the specification label on the side of the suction unit to ensure that the voltage and current indicated on the unit correspond with the voltage and current available. Make sure the power switch located on the side of the unit is in the "Off" position before connecting the unit to a power source. Figure 3 'Off' position 2. Switch the power switch to "I" position (on) to start running the unit. Figure 4 'On" position 6

Adjust the vacuum level from 0 to 560 mm Hg by turning the vacuum adjust knob (clockwise to increase vacuum and counter-clockwise to decrease vacuum). Refer to the vacuum gauge while setting the desired level of vacuum. To accurately read the gauge, block the patient end of the hose or cap off the collection bottle and allow the gauge to reach a stable vacuum reading. Vacuum Gauge Vacuum Adjust Knob Figure 5 Patient End of the Hose Figure 6 7

4. Attach the patient tubing to the appropriate suction device and begin procedure. 5. When fluid/sputum reaches the safe full level of the collection bottle, the suctioning will stop automatically (float shut-off). Safe Full Level Collection Bottle Figure 7 6. Switch the power switch to 110" position (off), to shut off the aspirator motor. 7. Disconnect and remove the collection bottle after the motor stops completely. Dispose of contents and bottle in accordance with state and local regulations. 8. When an empty collection bottle has been placed into the aspirator bracket and tubes are attached, turn on the unit and start to run suction again. ZN NOTE 1. If the unit sustains a severe drop, validity of the gauge must be checked. Inspect if the float shut-off is still functioning properly when the liquid in the collection bottle reaches the safe full level. 2. Always transport unit with vacuum adjust knob rotated fully clockwise in case unit is dropped. ZN CAUTION 1. When automatic float shut-off is activated, contents of the collection bottle should be emptied. Further suctioning could cause damage to the vacuum pump. 2. Should fluid be aspirated back into the unit, send your suction to an authorized service center for a detailed inspection nthe vacuum pump may have been damaged.

8. CLEANING INSTRUCTIONS Clean Collection Bottle: 1. Turn off the suction unit and allow vacuum to drop, then disconnect AC power source. 2. With the collection bottle still in the holder, remove the lid. The canister can now be taken out of the holder to be emptied. Collection Bottle Collection Bottle Figure 8 A NOTE Collection bottle should be emptied after each use. 3. Collection bottle should be thoroughly cleaned after each use by one of the following three methods: a. Wash in a hot water/dishwashing detergent solution and rinse with clean, hot tap water. Then wash in one part vinegar to three parts hot water solution. Rinse with hot tap water and air dry. b. Wash with rubbing alcohol and air dry c. Wash with a commercial (bacterial-germicidal) disinfectant, following disinfectant manufacturer's recommended instructions and dilution rates carefully.

Clean Suction Unit and Collection Bottle Lid: 1. Disconnect the suction unit from all external power sources. 2. Wipe the suction unit housing and collection bottle lid with a clean cloth and any commercial (bacterial-germicidal) disinfectant. ZN CAUTION Do not submerge in water as this will result in severe damage to the vacuum pump. Clean Tubing: 1. Disconnect the tubing from the unit. 2. Tubing should be rinsed thoroughly after every use by running hot tap water through it followed by a solution of one part vinegar to three parts hot water. 3. Rinse with hot tap water and air dry. 4. Keep the outer surface of the tubing clean by wiping with a clean, damp cloth. ZN WARNING The waste in collection bottle may cause respiratory infection which must be handled according to medical waste disposing regulation. Operator must wear gloves and medical class mask before cleaning the collection bottle, tubing and handle the wasting unit and/or accessories. 9. MAINTENANCE Inspect suction tubing and collection bottle for leaks, cracks, etc. before each use. ZN DANGER Electric shock hazard Do not attempt to open or remove the suction cabinet. If a service is required, return your suction to an authorized service center. Opening or tampering with the unit will void warranty. Bacteria Filter Change: 1. Bacteria filter should be replaced every two months. If overflow occurs, change the filter immediately. 2. Remove filter by disconnecting it from tubing connected to pressure adjusting valve and tubing connected to collection bottle lid assembly. 3. Replace witva new Schuco bacteria filter and connect to the two tubes as shown, making sure the filter side marked "FLUID SIDE" is toward the container. 10

Additional filters can be purchased from an authorized dealer. Tubing Collection Bottle & Lid Pressure Adjusting Valve Figure 9 A NOTE Use only Schuco filters. Do not substitute any other material for this bacteria filter. Improper substitution may lead to contamination or poor performance; Fuse Change: 1. Use only the same type of fuse to replace the broken fuse. 2. Fuse specification: Miniature Glass Fuse 5x20mm, Fast Blow (Quick Acting), F2A/250V. ZN WARNING When this unit or accessories reach the end of their useful lives (depends on using conditions), residues in collection bottle, tubing and filter may cause respiratory infection. Dump the collection bottle, tubing and filter into a waste bin specified for medical waste. 11

10. TROUBLESHOOTING Your S330A Aspirator contains no user-serviceable parts. If you believe your unit is not working properly, BEFORE YO U RETURN IT TO THE MEDICAL EQUIPMENT PROVIDER WHERE YOU PURCHASED IT, please take a few moments to check for these possible causes: PROBLEM Unit does not turn on Motor runs, no vacuum Low Vacuum ACTION 1. Check power source and connection 2. Ensure that the wall outlet is live 3. Check power cord for damage 1. Verify that tubes are connected 2. Check for leaks or tubing kinks 3. Ensure that float shut-off is not activated 4. Check for bottle leaks and cracks 1. Use vacuum adjust knob to increase vacuum level 2. Verify tube connections are secure 3. Check vacuum system for leaks 12

it SPECIFICATIONS/CLASSIFICATIONS Dimensions Weight. Maximum Vacuum Flow Range Sound Level Electrical Requirements (L) 375 x (W) 210 x (H) 260 mm (14.8 x 8.3 x 10.3 in) 6.4kgs (14J1-bs) 560 ± 3% mm Hg > 40 LPM < 58 dba S330A: AC 115 V'v 60Hz Power Consumption Bacteria Filter pore size Collection Bottle Capacity 70 wafts 0.45 microns 800 ml (cc) Operating Temperature 32 "-' 104 F (0 40 C) Operating Humidity Operating Atmospheric Pressure 95% RH 10.2 "15.4 psig ( 70 "106 kpa) Storage Temperature 14 158 F ( 10 "' 70 C) Storage Humidity 0-95% Storage Atmospheric Pressure Fuse Specification 7.3 "'15.4psig C 50 "106 kpa) Miniature Glass Fuse 5x20mm, Fast Blow (Quick Acting), F2A/250 V Equipment Classifications With respect to protection from electric shock Class I 13

12. WARRANTY Two years limited warranty The compressor portion of the S330A Aspirator is warranted to be free from defective workmanship and materials for a period of two years from date of purchase and six months on accessories. Defective part(s) will be repaired or replaced at the service center's discretion if the unit has not been tampered with or used improperly during that period. Make certain that any malfunction is not due to inadequate cleaning or failure to follow the instructions. If repair is necessary, please contact the medical equipment provider where you purchased it or an authorized Schuco service center. A NOTE This warranty does not cover providing a loaner unit, compensating for costs incurred in rental while said unit is under repair, or costs for labor incurred in repairing or replacing defective part(s). THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO THE DURATION OF THE EXPRESS LIMITED WARRANTY AND TO THE EXTENT PERMITTED BY LAW ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED. THIS IS THE EXCLUSIVE REMEDY AND LIABILITY FOR CONSEQUENTIAL AND INCIDENTAL DAMAGES UNDER ANY AND ALL WARRANTIES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. SOME STATES (IN THE US) DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, OR THE LIMITATION OR EXCLUSION OF CONSEQUENTIAL OR INCIDENTAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state (in the US). Manufacturer's Note Thank you for choosing a Schuco S330A Aspirator. We trust you will be pleased with the unit's performance and quality. If you have any questions or comments, please send them to our address below. For aspirator service or supply of accessories please contact your authorized S chuco Aspirator provider. 14

Allied Healthcare Products, Inc. 1720 Sublette Avenue - St. Louis, MO 63110 Tel: 314-771-2400 Tel: 800-444-3954 Fax: 314-771-0650 E-mail: www.alliedhpi.com International Offices in: Europe, Asia and South America 15