Tunnel Fire Dynamics and Evacuation Simulations

Similar documents
Considerations in the Design of Smoke Management Systems for Atriums

CFD-AIDED TENABILITY ASSESSMENT OF RAILWAY TUNNEL TRAIN FIRE SCENARIOS

CFD ASSESSMENT OF RAILWAY TUNNEL TRAIN FIRE SCENARIOS

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

Fire and smoke management in a uni-directional road tunnel for a congested traffic condition

Virtual Compartment: An Alternative Approach to Means of Egress Design in Airport Pedestrian Tunnel

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

Case Study 1 Underground Car Park

Statue of Liberty: A Risk Analysis

Fire and Smoke Management in a Uni-Directional Road Tunnel for a Congested Traffic Condition

COSTCO, SAN FRANCISCO A PRESCRIPTIVE AND PERFORMANCE BASED ANALYSIS OF FIRE PROTECTION SYSTEMS AND DESIGN

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

Case Study of Underground Car Park. Team Japan

SCALE MODEL STUDIES ON SMOKE MOVEMENT IN INCLINED TUNNEL WITH LONGITUDINAL VENTILATION AND SMOKE BARRIERS

Using FDS Modelling to Establish Performance Criteria for Water Mist Systems on Very Large Fires in Tunnels

Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

5B-3 6th Asia-Oceania Symposium on Fire Science and Technology 17-20, March, 2004, Daegu, Korea

Human Factors - Egress Analysis for High Hazard Occupancies. Presented by: Michael J. Klemenz, PE, SFPE

EVACUATION MODELING DEPENDENCE ON INPUT PARAMETERS

CFD Analysis of Fire Characteristics on Subway Junction Station

Third Runway Project APM Depot Fire Engineering Design. Presented by Ir Wilson Sau-kit TSANG

Sprinklers Modeling for Tunnel Road Fire Fighting

SMOKE MANAGEMENT AND EGRESS ANALYSIS OF A SPORTS ARENA USING THE PERFORMANCE-BASED DESIGN

Fire Research and Education at the University of Maryland

Case Study 2 (Production and Storage Buildings) - Spain

and Sprinkler System in Resalat Tunnel of Tehran

STUDY FOR SAFETY AT A RELATIVELY SHORT TUNNEL WHEN A TUNNEL FIRE OCCURRED

Fire Hazard Analysis of Technical Area 53 Building 1

Impact of Tunnel Ventilation on Tunnel Fixed Fire Suppression System

Figure 1. Structure Used For the Simulations.

Full-Scale Measurement and Numerical Analysis of Liquefied Petroleum Gas Water Heaters with Ventilation Factors in Balcony

Computational simulation of road tunnel fire protection by sprinklers

Natural Ventilation A Green Smoke Control Approach

Smoke Layer Height and Heat Flow through a Door

Recent BRANZFIRE enhancements and validation

TENABILITY CRITERIA IN UNIQUE SITUATIONS AND ATYPICAL BUILDINGS

Building Description Applicable Codes & Standards Prescriptive Requirements. Performance Based Design

ANALYSIS OF SMOKE MOVEMENT IN A BUILDING VIA ELEVATOR SHAFTS

IFireSS International Fire Safety Symposium Coimbra, Portugal, 20 th -22 nd April 2015

Emergency Ventilation System Design - Preliminary Report Shishir Gupta

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES

Case Study 1 Underground car park

EMERGENCY VENTILATION FOR SMOKE CONTROL IN ROADWAY TUNNELS (NCHRP PROJECT TASK 363)

Water Mist-Based Fire Suppression Modelling of an Office Space Scenario

Sandeep V. Lutade 1, Krunal Mudafale 2, Ranjan Kishore Mallick 3 1, 2

Potential Impact of New UL Fire Test Criteria

Experimental Room Fire Studies with Perforated Suspended Ceiling

Impact of quick incident detection on safety in terms of ventilation response

A case study for integrated modelling of personnel evacuation with pool fire simulation to increase safety in design for offshore oil and gas projects

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

NUMERICAL SIMULATION OF FIRE SPREAD IN TERMINAL 2 OF BELGRADE AIRPORT. PO Box 522, Belgrade, Serbia and Montenegro

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

incorporating Contractors guide to car park ventilation A no-nonsense guide to the safe ventilation of underground and covered car parks

Recent Advances in Fire Suppression Modeling Issues & Perspectives of Fire Safety Engineering Applications

The Study of Evacuation Times from the Multiplex Theatres

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

NUMERICAL SIMULATION OF THE NEW SOUTH WALES FIRE BRIGADE COMPARTMENT FIRE BEHAVIOUR TRAINING TEST CELL

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

Simulation of Full-scale Smoke Control in Atrium

CFD STUDY OF FIRE PROTECTION SYSTEMS IN TUNNEL FIRES

Smoke Alarm Research at NIST

PROPOSAL BALLOT DUE BY: Thursday, September 18, 2008

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

Ventilation for Smoke Control, Fire Control & Life Safety in Tunnels. Dr. Ricky Carvel BRE Centre for Fire Safety Engineering University of Edinburgh

ctbuh.org/papers Fire Engineering the Tallest Building in the Historic City of Manchester, UK Title:

Edward K. Budnick Hughes Associates, Inc. Wheaton, Maryland, U.S.A SUMMARY. that is entrained or otherwise mixed into the mass.

An experimental study of the impact of tunnel suppression on tunnel ventilation

Construction Innovation Center Building 186

Construction Warehouse. FPE 596 Culminating Experience In Fire Protection Engineering Final Project (Spring 2014) By Ben Johnson

CFD Model of a Specific Fire Scenario

Investigating the Effects of Sprinkler Sprays on Fire-Induced Doorway Flows: A Two-Part Study. Jeremiah Crocker and Dr. Bin Xiao New Technology Team

Smoke Management in Subway Stations Due to Train Arson Fire Scenario

Case Study : Evaluation Smoke & Evacuation Performance of a College Auditorium

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

Life Safety - Means of Egress/Exits NFPA 101

General Principles of Smoke Control

1. Revise and A to read as follows:

A New Zealand Case Study Building Design 11 th International Conference on Performance

A comparison between emergency ventilation systems semi-transvers ventilation and natural ventilation in Road Tunnel A

DEALING WITH FIRE SAFETY

( )

LONGITUDINAL VENTILATION FOR SMOKE CONTROL IN A TILTED TUNNEL BY SCALE MODELING

Building Codes & Standards for Healthcare. Healthcare Construction Certificate - Level 1

Tunnel Axial Flow Fan

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /

An Analysis of Compartment Fire and Induced Smoke Movement in Adjacent Corridor

12F052 ADVANCED FLORIDA (MULTIPLE OCCUPANCY BUILDINGS)

Aspirating Gas Detection CFD Modelling Predicts Application Performance

Comparative Evaluation Method for Fire Safety Design of Large Storage Spaces

Fire Scenario Influence of Material of Boundary Condition on Results

ICC CODE CORNER 2012 IFC Code & Commentary

Developing a Fire Test Strategy for Storage Protection Under Sloped Ceilings

On Estimating Heat Release Rate for a Design Fire in Sprinkler Protected Area

Chapter 17, Initiating Devices

Fire Protection System and Life Safety Evaluation of Building X. Anthony W. Sublett

1. Revise , from what was done by Second Revision SR-95 (Annual 2014 revision cycle NFPA 101 Second Draft), to read as follows:

Agency for Health Care Administration

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

GAS DETECTOR LOCATION. Ø.Strøm and J.R. Bakke, GexCon AS, Norway

Transcription:

Tunnel Fire Dynamics and Evacuation Simulations James Priest, PhD & James Niehoff DGS-SEE Seminar on Fire Protection for Physics Research Facilities 7 & 8 October 2015

Introduction (Background) Presentation data based on Hughes Associations Inc. (HAI) report and presentation of May 2010, in support of a International Linear Collider (ILC) conceptual design addressing a single tunnel 100m (328ft.) and 30m (100ft.) below the surface Main LINAC & Damping Ring Tunnel diameter sizes included 4.5m (14.75ft), 5.0m (16.4ft) 5.5m (18ft), and 6.5m (21.3ft) Total llc Tunnel length 29.6km (18 miles) Pumps, oil filled transformers, mineral oil, office furniture, office related equipment (significant combustible loads) will be located above ground 2

Goals Understand the spread of fire and smoke in the Main LINAC and Damping Ring tunnels Understand fire and smoke behavior for a range of tunnel diameters Determine the fire size required to create untenable conditions in the tunnel before occupants can evacuate Analyze the fuel loads in the Main LINAC and damping ring tunnels and base caverns and assess fire scenarios Develop guidelines for tunnels and base caverns that will allow occupants in the tunnel to evacuate safely in the event of a fire 3

Approach Research tunnel fire dynamics Model representative tunnel fire scenarios using FDS to analyze the effects of: Smoke movement Fire size Fire location (tunnel or base cavern) Determine the time required for occupants to evacuate Determine the maximum fire size that will allow occupants to evacuate safely 4

References (Partial) Beard A. and Carvel R., The Handbook of Tunnel Fire Safety, Thomas Telford Publishing, London 2005 Hu, L., H., Huo, R., Chow, W.K., Wang, H.B., & Yang R.X, Decay of Buoyant Smoke Layer Temperature along the Longitudinal Direction in Tunnel Fires, Journal of Applied Fire Science, 2005 Babrauska V., Heat Release Rates, Chapter 3, Society of Fire Protection Engineering Handbook of Fire Protection Engineering 4 th Edition, National Fire Protection Association (NFPA) Quincy, MA 2008 Bryan, J. Behavioral Response to Fire and Smoke, Chapter 12, Society of Fire Protection Engineering Handbook of Fire Protection Engineering 4 th Edition, National Fire Protection Association (NFPA) Quincy, MA 2008 5

Tunnel Fire Dynamics Smoke movement in level, naturally ventilated tunnels U Smoke layer moves uniformly in both directions away from fire at velocity U U Entrained air Fire location Entrained air Near the fire, the smoke layer is hot (strong buoyancy) and remains close to the ceiling with little mixing. As the smoke moves away from the fire, cooling occurs causing smoke to loose buoyancy. Descending smoke mixes with the entrained air and is drawn back towards the fire. This is referred to as back-layering 6

Fire Dynamics Simulator (FDS) (How) Developed by the National Institute of Standards and Technology (NIST) Computational fluid dynamics (CFD) software Specifically formulated to calculate heat and smoke transport from fires Extensively validated against experimental data Model comprised of one or more numerical domains (meshes) Each domain divided into rectilinear numerical grid 7

Main LINAC Fire Scenarios Representative fire scenarios Model using the Fire Dynamics Simulator (FDS) Scenario 1: Fire located between vertical exits representing the maximum travel distance to vertical exits Scenario 2: Fire in base cavern represents the maximum travel distances for occupants to area of refuge (AOR) 8

Damping Ring Fire Scenarios Representative fire scenarios Fire scenarios not modeled in damping ring base cavern and straight section housing wigglers since it is isolated from open tunnel areas by isolation barriers Scenario 1: Fire located in straight portion of damping ring Scenario 2: Fire located in curved portion of damping ring 9

Fire Model: Potential Fire Scenarios Cable Tray Fires Low cable loadings Cables embedded under concrete floors or encased in rigid conduit Miscellaneous Combustibles Trash Other combustibles Pool / spill fires o o o o o Rapid growth Primary fuel present is transformer oil (mineral oil) Multiple components in ILC tunnel and base cavern contain oil One 76 meter section of tunnel may contain up to 470 gallons of oil Largest quantity of oil in single component is a 100 gallon tank housed in a step down transformer Pool / spill fires represent the most demanding fire scenarios 10

Pool/Spill Fires Pool fires are defined as the burning of liquids in a contained area (i.e. dike) burning area is constant Spill fires refer to the burning of an unconfined area of liquid fuel Continuous spill burning is fed by a flow of spilling fuel Unconfined spill fixed volume of fuel is spilled on a surface and burns until fuel is consumed Pool/spill fires grow to peak size at rapid rate Model fires as instant growth, steady burning Incremental fire sizes simulated for each scenario in FDS model Determine maximum fire size which allows for safe egress of tunnel occupants Determine maximum pool fire area Determine maximum spill rate 11

Fire Modeling Approach Create tunnel geometry in FDS Tunnel geometry remote from fire incorporating 12.7cm (5 inches) x 12.7cm (5 inches) x 30cm (12 inch) cells Model Main LINAC, base caverns, and Damping Ring for a range of tunnel diameters 4.5m (14.75ft), 5.0m (16.4ft) 5.5m (18ft), and 6.5m (21.3ft) tunnel diameters Model tunnel length of 500m (1,600ft.) to determine maximum smoke filling rates. Determine expected occupant travel speeds and use FDS models to determine maximum fire size that can be tolerated such that the smoke travel rate is less than the occupant travel speed. 12

Assumptions and Limitations Hughes recommends sprinkler protection throughout; however, 5m diameter tunnel was also modeled without sprinklers Excludes any construction scenario Tunnel Ventilation Airflow velocities were assumed to be less than 1 m/s Smoke exhaust is not modeled, nor assumed to be provided Airflow effects in tunnel caused by temperature-driven flow in vertical shafts and/or wind effects above ground were not considered vertical shafts were considered sealed No considered for smoke may vent from the base cavern fire into vertical access shafts again access shafts were considered sealed 13

Main LINAC Section Drawing 14

Main LINAC Tunnel FDS Geometry 22 m long nearfield tunnel section Fire modeled in center of highfidelity tunnel section 12.7cm cells isometric view showing grid 400 m long tunnel section. 15

Base Cavern 16

Base Cavern and Tunnel FDS Geometry Base cavern height assumed to be approximately the same height as tunnel Fire Location (Near Tunnel) 17

Damping Ring Drawing Section 18

Curved Damping Ring Tunnel FDS Geometry Curved and straight tunnel sections modeled Fire located in center of highfidelity tunnel section 19

Straight Damping Ring Tunnel FDS Geometry Curved and straight tunnel sections modeled Fire located in center of high-fidelity tunnel section 20

Occupant Egress Occupant load of 50 people per egress area (tunnel space between two shafts) Approximately 70 m 2 (753.5 sq. ft.) per occupant Given the low occupancy load in the tunnel: Queuing (congestion) would not occur in tunnel during an emergency Occupant travel speeds would be consistent with normal walking speeds on uncongested, level pathways Occupant loadings of lesser density than 3.3 m 2 (35.5 sq. ft.) per occupant would not be expected to reduce travel speeds Occupant characteristics Occupants are generally assumed to be able-bodied adults who are awake and aware of their surroundings It is possible that occupants may be injured during an evacuation causing reduced walking speeds 21

Walking Speed A review of data on walking speeds indicates: Average walking speeds of 1 m/s to 1.4 m/s for adults without locomotion disabilities Average walking speed of 0.95 m/s for adults with crutches or with a locomotion disability requiring no walking aid Average walking speed of 0.72 m/s for adults with locomotion disability who require pauses for rest Walking speed criteria for analysis 1 m/s to escape from area of fire origin and beyond initial backlayering of smoke 0.7 m/s once the occupant has moved beyond initial backlayering to allow for brief rest periods without being overcome by smoke 22

Tenability Criteria The rate at which tenability decreased in the tunnel was assessed using the following criteria. Quantities measured 1.8 meter (6 feet) above floor Visibility is the critical tenability criterion (i.e. visibility is lost before other tenability criteria are exceeded) Results presented in terms of visibility Criteria Temperature CO Concentration O 2 Concentration Visibility Limit < 76 C (168 F) < 1,200 ppm > 17% by volume > 10 m (30 ft) 23

Results of FDS Modeling For each tunnel diameter modeled, the maximum fire size which can be sustained while allowing occupants to outrun smoke was calculated Corresponding pool fire sizes and spill volumes were calculated Sprinklers cool the smoke layer but only have a moderate effect on slowing the spread of smoke down the tunnel Sprinklers would be expected to limit fire spread Limiting fire sizes calculated for the Main LINAC were the same as those for the straight damping ring sections Fire size is a more important driver than tunnel obstructions 24

Main LINAC Tunnel Fire Results Onset of back-layering Back-layering fully developed 25

Main LINAC Tunnel Fire Results Visibility m Onset of back-layering Occupants must travel 1.0 m/s up to this point Occupants travel 0.7 m/s beyond this point Back-layering fully developed Travel speed required to outrun back-layering = 1.03 m/s Travel speed required to stay ahead of smoke layer = 0.63 m/s 26

Main LINAC Tunnel Fire Results Visibility m Onset of back-layering Occupants must travel 1.0 m/s up to this point Occupants travel 0.7 m/s beyond this point Back-layering fully developed Travel speed required to outrun back-layering = 1.03 m/s Travel speed required to stay ahead of smoke layer = 0.63 m/s 27

5m Tunnel Fire Animation 1,000kw Fire Size Plan View 28

Summary of Tunnel Fire Results Tunnel Diameter (m) Limiting Fire Size (kw) Maximum Fuel Spill Area (m 2 ) Maximum Unconfined Spill Rate (L/min) 4.5 750 0.8 1.3 5.0 1,000 1.0 1.7 5.5 1,100 1.1 1.9 6.5 1,500 1.4 2.6 Results for Main LINAC apply to straight portions of damping ring tunnel Smoke movement is essentially the same in straight tunnels of the same diameter. The difference in obstructions between the Main LINAC and damping ring have a minimal effect. 29

Base Cavern Fire Results 1.0 m/s 0.7 m/s Travel speed required to outrun back-layering = 0.83 m/s Travel speed required to stay ahead of smoke layer = 0.62 m/s 30

Base Cavern Fire Results 1.0 m/s 0.7 m/s Travel speed required to outrun back-layering = 0.94 m/s Travel speed required to stay ahead of smoke layer = 0.73 m/s 31

5m Base Cavern Fire Animation (4,000kw Fire Size) Plan View 32

Summary of Base Cavern Fire Results Tunnel Diameter (m) Limiting Fire Size (kw) Maximum Fuel Spill Area (m 2 ) Maximum Unconfined Spill Rate (L/min) 4.5 3,000 2.4 5.1 5.0 4,000 3.0 6.8 5.5 4,500 3.3 7.7 6.5 6,000 3.6 10.2 Smoke spills out of the base cavern and impacts tunnel walls causing the ceiling jet velocity to decrease 33

Damping Ring 4.5m Tunnel Fire Results Travel speed required to outrun back-layering = 0.98 m/s Travel speed required to stay ahead of smoke layer = 0.5 m/s 34

Damping Ring 6.5m Tunnel Fire Results Travel speed required to outrun back-layering = 0.91 m/s Travel speed required to stay ahead of smoke layer = 0.65 m/s 35

Summary of Damping Ring Fire Results Tunnel Diameter (m) Limiting Fire Size (kw) Maximum Fuel Spill Area (m 2 ) Maximum Unconfined Spill Rate (L/min) 4.5 2,500 2.0 4.3 5.0 3,250 2.5 5.5 5.5 4,000 3.0 6.8 6.5 5,000 3.6 8.5 Results apply to curved sections of damping ring Limiting fire sizes in curved section of tunnel increase over straight tunnel section The speed at which smoke descends to head-level decreases due to the curvature of the tunnel The straight tunnel sections of the damping ring represent limiting fuel spill quantities for the damping ring 36

Compiled Tunnel Fire Results Fire Location LINAC / Straight Damping Ring Tunnel Tunnel Diameter (m) Limiting Fire Size (kw) Maximum Fuel Spill Area (m 2 ) Maximum Unconfined Spill Rate (L/min) 4.5 750 0.8 1.3 5.0 1,000 1.0 1.7 5.5 1,100 1.1 1.9 6.5 1,500 1.4 2.6 4.5 3,000 2.4 5.1 Base Cavern 5.0 4,000 3.0 6.8 5.5 4,500 3.3 7.7 6.5 6,000 3.6 10.2 4.5 2,500 2.0 4.3 Curved Damping Ring Tunnel 5.0 3,250 2.5 5.5 5.5 4,000 3.0 6.8 6.5 5,000 3.6 8.5 37

Egress Analysis The Available Safe Egress Time (ASET) was greater then Required Safe Egress Time (RSET) Visibility is lost at a rate 0.63 m/s travel egress speed of 0.72 m/s In other words, occupants can comfortably walk faster than smoke can fill the tunnel for a given fire size and can reach the vertical shaft or area of refuge before being exposed to untenable conditions. 38

Conclusions The travel distances referenced in NFPA 520 are validated, i.e., the maximum travel distance of 610m 2,000ft.) to an exterior access point or area of refuge will allow occupants to evacuate safely The size of pool/spill fire (e.g., transformer oil) can be restricted by establishing fuel containment strategies Increasing the tunnel diameter allows the combustible fuel loading in a tunnel to be increase without affecting the ability of occupants to evacuate safely Administrative controls must be established as part of a combustible management strategy, e.g., transient combustibles may be present in the tunnel 39

Questions? 40