coldpack water cooled chillers / heat pumps and motoevaporating units C_GNR_0508

Similar documents
COLDPACK_. water cooled chillers / heat pumps and condenserless chillers

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

GLIDER_. air cooled liquid chilled chillers / heat pumps

turb new unico turbo frigo turbo fl Liquid chiller equipped with magnetic levitation twostage centrifugal compressors RCGROUP SpA C_GNR_0711

IDROCOMPL _. liquid chillers, condenserless chillers, heat pump with Idrocompl system

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

nemo a hp rcgroupairconditioning R410A

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

kw COOLING kw HEATING

next NEXT EVO CW kw UP FLOW DOWN FLOW CHILLED WATER E C CLOSE CONTROL AIR CONDITIONERS FOR CHILLED WATER FEEDING,

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

GLIDER EVO GLIDER EVO. rcgroupairconditioning

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

unico pf unico pf rcgroupairconditioning

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

pyxis u pyxis ua NEW rcgroupairconditioning

Water chillers water/water type SIGMA Technical information manual

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

next DX.U.S* 052.Z2.H6.DC

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

pyxis pyxisa NEW rcgroupairconditioning

44,9 202,0 kw. technicalcatalogue

kw. technicalcatalogue

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

glider evo cla glider evo cla A-CLASS rcgroupairconditioning

21,8 222 kw COOLING 25,2 236 kw HEATING

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

PYXIS U PYXIS U. rcgroupairconditioning

Energy-Saving Industrial Water Chillers

unico turbo fl kw R134a MICRO CHANNEL OIL FREE INVERTER FLOODED CLASS E C Energy Class RCGROUP SpA fiftycoolyears C_GNR_0113

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

AIR CONDITIONERS. RCGROUP SpA fiftycoolyears C_GNR_0113

Water cooled chillers and heat pumps

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

NEXT DL NEXT DL. rcgroupairconditioning

Air Cooled Chillers & Heat Pumps WinPACK HE-A

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

2013 Product Range Precision Air Conditioners (CRAC)

KELVIN Clim F497. Kelvin air conditioning

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

kw. technicalcatalogue

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

CRIMSON & CRIMSON MAX

unico turbo FL unico turbo FL LOW NOISE A-CLASS INVERTER rcgroupairconditioning

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

Process glycol chillers

LZT High efficiency air to water heat pumps with E.V.I. compressors

EQPHU PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR OUTDOOR INSTALLATION

Hyperchill. water chillers

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

H4T R410A. refrigerant

Air cooled water chillers

EQUH PF PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR INDOOR INSTALLATION

RC GROUP. MULTIPLO.A.STD/ELN G Multifunctions air cooled liquid chillers with Scroll compressors and axial fans R407C. SCROLL compressors kw

DIN EN , DIN EN , DIN EN , DIN EN

Air cooled industrial chillers

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

FRIGO SCREW CLA PLUS Packaged water cooled liquid chillers in A+ class energy efficiency for indoor installation. Cooling Capacity: kw

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

GENERAL INFORMATIONS

PRODUCT GUIDE

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

next p dw next p dw rcgroupairconditioning

Water cooled chillers and heat pumps

A Complete Line Of Remote Rack Refrigeration Systems

LZA High efficiency air to water heat pumps with HP compressor

NQ Series Portable Chillers

1

Transcription:

coldpack water cooled chillers / heat pumps and motoevaporating units 133

134 COLDPACK VERSIONS : COLDPACK.W (R407C) Cooling capacity 32,2 513,0 Liquid chiller equipped with scroll compressor and built-in water cooled condenser. coldpack.w/j GENERAL FEATURES The range Coldpack chillers allows to meet all airconditioning requirements in residential, commercial and hi-tech applications, as well as in the tertiary sector. These machines are available in a full range of dimensions, models and versions, with a rich variety of accessories and optional, so that they can become the ideal solution for installation in office buildings, public buildings, trade centres, industrial buildings, wine-cellars as well as for a variety of other applications in the hi-tech and process sector. Heavy-duty construction, thanks to their design and to the choice of materials and components, that reflect the policies followed for the machines meant for critical environments, where they are required to operate 365 days/year. In this way, continuous and regular operation of the machines is ensured under any load conditions. COLDPACK.W.P (R407C) Cooling capacity 33,9 606,0 Heating capacity 35,7 604,0 Heat pump liquid chiller equipped with scroll compressor and built-in water cooled condenser. COLDPACK.A (R407C) Cooling capacity 29,9 539,0 Motoevaporating unit equipped with scroll compressor for remote air cooled condenser matching. COLDPACK.A.P (R407C) Cooling capacity 30,2 369,0 Heating capacity 31,6 398,0 Heat pump motoevaporating unit equipped with scroll compressor for remote air cooled condenser matching. corcgroup SpA

COLDPACK 135 MAIN COMPONENTS Housing in epoxy painted galvanized steel sheet Scroll compressors Welded plate evaporator Compact dimensions, limited weights, easy transport and handling to shorten installation time. Many models can be transported in common lifts and cross standard doors without any difficulty. Welded plate condenser Cycle reversing valve (heat pump) IDEA defrosting system (heat pump) MP.COM microprocessor control Antifreeze system Water flow control by pressure switch Pump-Down stop system Electrical box in separate compartment Main switch with door lock safety IDEA defrosting system COLDPACK.A.P version Patented defrosting system with dynamic reading of working parameters. Thanks to proprietary software it senses the real presence of brine on the coil starting defrosting cycles only in that situation. This brings a remarkable energy saving (more than 20-30% on the average) and a higher working continuity compared with traditional systems. MAIN OPTIONAL ACCESSORIES Water/water heat pump The COLDPACK.W.P. version is a water cooled heat pump chiller, with reverse cycle on refrigerant. This proposal allows to avoid the inversion on the hydraulic circuit, making easy the installation and the water distribution. Water regulating valve (COLDPACK.W) Remote control panel Partial or total heat reclaim Serial port Remote air cooled condenser (COLDPACK.A) Two energy effieciency levels single refrigeration circuit and several compressors in parallel. This version allows to achieve high energy efficiency during partial load working mode (S version). double refrigeration circuit, with energy efficiency in line with the top levels of the market (D version). ldpack RCGROUP SpA

136 COLDPACK TECHNICAL DATA AND NOMINAL PERFORMANCES COLDPACK.W single circuit - water cooled T.29 T.35 T.43 T.50 T.55 T.68 T.84 T.110 T.130 T.160 T.200 T.260 Z1 Z1 Z1 Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S Z3-S Z3-S J4 J4 J5 J5 J5 J6 J6 J7 J7 J8 J8 J9 32,2 41,4 47,4 52,0 55,1 76,3 91,4 114,0 142,0 182,0 219,0 289,0 1 1 1 2 2 2 2 2 2 2 3 3 6,9 9,3 10,9 13,0 15,5 21,1 22,7 35,4 40,3 49,6 58,4 68,6 1 1 1 1 1 1 1 1 1 1 1 1 260 280 360 465 465 490 615 720 740 990 1150 1250 54,0 56,0 56,0 57,0 57,0 59,0 59,0 62,0 64,0 66,0 65,8 67,8 COLDPACK.W double circuit - water cooled T.50 T.55 T.68 T.84 T.110 T.130 T.160 T.220 T.270 T.330 T.400 T.470 T.510 Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z4-D Z4-D Z4-D Z6-D Z6-D Z6-D J5 J5 J6 J6 J7 J7 J8 J8 J9 J9 J10 J10 J10 53,1 60,8 80,5 91,4 123,0 150,0 187,0 238,0 304,0 381,0 418,0 472,0 513,0 2 2 2 2 2 2 2 4 4 4 6 6 6 12,6 14,8 19,4 22,5 31,3 37,8 47,9 64,0 72,8 92,4 105,0 114,0 125,0 2 2 2 2 2 2 2 2 2 2 2 2 2 500 500 525 650 760 780 1000 1030 1420 1550 2110 2220 2270 57,0 57,0 59,0 59,0 62,0 64,0 66,0 65,0 67,0 69,0 68,8 69,8 70,8 (1) Referred to chilled water temperature 12/7 C and condenser water inlet temperature at 30 C (2) Sound pressure 1m far in free field conditions according to ISO3744 norms COLDPACK.W.P single circuit - heat pump - water/water T.29 T.35 T.43 T.50 T.55 T.68 T.84 T.110 T.130 T.160 T.200 T.260 Z1 Z1 Z1 Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S Z3-S Z3-S J4 J4 J5 J5 J5 J6 J6 J7 J7 J8 J8 J9 33,9 43,6 50,0 54,8 58,0 80,4 96,4 120,0 154,0 193,0 233,0 305,0 35,7 43,6 53,7 62,0 70,2 86,9 105,0 137,0 168,0 206,0 247,0 313,0 1 1 1 2 2 2 2 2 2 2 3 3 5,7 7,8 9,2 10,8 12,8 17,7 19,1 29,5 34,1 41,8 49,4 57,9 9,2 11,6 14,2 16,5 19,3 24,0 28,8 38,4 47,6 56,2 70,5 81,6 1 1 1 1 1 1 1 1 1 1 1 1 268 288 368 475 475 500 630 750 750 1030 1060 1300 54,0 56,0 56,0 57,0 57,0 59,0 59,0 62,0 64,0 66,0 65,8 67,8 (1) Referred to chilled water temperature 12/7 C and condenser water inlet temperature at 30 C (2) Referred to hot water temperature 40/45 C and chilled water outlet temperature at 7 C (3) Sound pressure 1m far in free field conditions according to ISO3744 norms RCGROUP SpA

COLDPACK 137 TECHNICAL DATA AND NOMINAL PERFORMANCES COLDPACK.W.P double circuit - heat pump - water/water T.50 T.55 T.68 T.84 T.110 T.130 T.160 T.220 T.270 T.330 T.400 T.470 T.510 Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z4-D Z4-D Z4-D Z6-D Z6-D Z6-D J5 J5 J6 J6 J7 J7 J8 J8 J9 J9 J10 J10 J10 55,9 63,9 84,6 96,2 129,0 160,0 197,0 251,0 323,0 400,0 498,0 560,0 606,0 60,0 68,6 85,8 102,0 135,0 165,0 203,0 259,0 333,0 411,0 495,0 556,0 604,0 2 2 2 2 2 2 2 4 4 4 6 6 6 10,5 12,2 16,3 18,9 26,2 32,1 40,5 53,6 61,8 77,9 87,7 95,3 104,0 16,5 19,1 23,6 28,7 37,5 46,6 55,4 76,0 92,1 110,0 138,0 150,0 164,0 2 2 2 2 2 2 2 2 2 2 2 2 2 515 515 540 676 805 825 1060 1110 1510 1650 2110 2220 2270 57,0 57,0 59,0 59,0 62,0 64,0 66,0 65,0 67,0 69,0 68,8 69,8 70,8 (1) Referred to chilled water temperature 12/7 C and condenser water inlet temperature at 30 C (2) Referred to hot water temperature 40/45 C and chilled water outlet temperature at 7 C (3) Sound pressure 1m far in free field conditions according to ISO3744 norms COLDPACK.A double circuit - air cooled motoevaporating unit Remote condenser TEAM.MATE DX.A 2 x T.50 T.55 T.68 T.84 T.110 T.130 T.160 T.220 T.270 T.330 T.400 T.470 T.510 Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z4-D Z4-D Z4-D Z6-D Z6-D Z6-D J5 J5 J6 J6 J7 J7 J8 J8 J9 J9 J10 J10 J10 50,9 58,9 78,0 89,4 121,0 148,0 185,0 239,0 295,0 367,0 438,0 495,0 539,0 2 2 2 2 2 2 2 4 4 4 6 6 6 13,3 15,2 20,0 23,2 31,6 38,4 48,2 63,2 76,7 96,4 121,0 133,0 145,0 2 2 2 2 2 2 2 2 2 2 2 2 2 445 445 470 515 700 710 930 950 1310 1420 1980 2060 2110 57,0 57,0 59,0 59,0 62,0 64,0 66,0 65,0 67,0 69,0 68,8 69,8 70,8 M.31 M.37 M.50 M.50 M.79 M.105 M.118 M.145 T.260 L T.260 L -- -- -- COLDPACK.A single circuit - air cooled motoevaporating unit Remote condenser TEAM.MATE DX.A 1 x T.29 T.35 T.43 T.50 T.55 T.68 T.84 T.110 T.130 T.160 T.200 T.260 Z1 Z1 Z1 Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S Z3-S Z3-S J4 J4 J5 J5 J5 J6 J6 J7 J7 J8 J8 J9 29,9 39,1 45,3 50,9 58,9 77,5 89,7 121,0 148,0 184,0 220,0 277,0 1 1 1 2 2 2 2 2 2 2 3 3 7,6 10,0 11,5 13,3 15,2 20,0 23,2 31,6 38,4 48,2 57,5 72,3 1 1 1 1 1 1 1 1 1 1 1 1 243 260 352 420 420 445 490 670 680 910 1060 1140 54,0 56,0 56,0 57,0 57,0 59,0 59,0 62,0 64,0 66,0 65,8 67,8 M.37 M.50 M.50 M.72 M.72 M.105 M.118 M.145 M.158 T.260 L T.260 D T.390 L (1) Referred to chilled water temperature 12/7 C and air to the condenser at 35 C (2) Sound pressure 1m far in free field conditions according to ISO3744 norms RCGROUP SpA

138 COLDPACK TECHNICAL DATA AND NOMINAL PERFORMANCES COLDPACK.A.P single circuit - air cooled heat pump motoevaporating unit T.29 T.35 T.43 T.50 T.55 T.68 T.84 T.110 T.130 T.160 Z1 Z1 Z1 Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S Z2-S J4 J4 J5 J5 J5 J6 J6 J7 J7 J8 30,2 39,4 45,4 51,5 59,6 78,2 90,1 121,0 149,0 185,0 31,6 41,8 47,7 53,9 62,4 82,3 95,0 128,0 157,0 197,0 1 1 1 2 2 2 2 2 2 2 7,7 10,1 11,7 13,3 15,4 20,3 23,4 31,9 38,7 48,8 8,5 11,2 13 15,2 17,7 23,4 26,4 36,6 44,1 54,8 1 1 1 1 1 1 1 1 1 1 251 268 360 430 430 455 500 690 700 930 54,0 56,0 56,0 57,0 57,0 59,0 59,0 62,0 64,0 66,0 COLDPACK.A.P double circuit - air cooled heat pump motoevaporating unit T.50 T.55 T.68 T.84 T.110 T.130 T.160 T.220 T.270 T.330 Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z2-D Z4-D Z4-D Z4-D J5 J5 J6 J6 J7 J7 J8 J8 J9 J9 51,6 59,6 78,6 91,2 123,0 151,0 187,0 240,0 296,0 369,0 54,1 62,7 83,0 95,7 130,0 160,0 199,0 255,0 318,0 398,0 2 2 2 2 2 2 2 4 4 4 13,3 15,4 20,3 23,4 32,0 38,8 48,9 63,8 77,5 97,6 15,0 17,5 22,8 25,6 34,8 42,1 53,2 73,2 85,2 107,0 2 2 2 2 2 2 2 2 2 2 455 455 480 525 720 730 950 990 1350 1460 57,0 57,0 59,0 59,0 62,0 64,0 66,0 65,0 67,0 69,0 (1) Referred to chilled water temperature 12/7 C and condensing temperature at 45 C (2) Referred to hot water inlet temperature 40/45 C and evaporating temperature at 3 C (3) Sound pressure 1m far in free field conditions according to ISO3744 norms dimensions (mm) COLDPACK J a b c J4 1.000 650 1.400 J5 - J6 1.200 650 1.500 c J7 1.200 750 1.700 J8 - J9 1.800 1.200 1.740 b a Te l. + 3 9 0 3 8 2 4 3 3 8 1 1 w w w. r c g r o u p. i t s a l e s @ r c g r o u p. i t Technical data and dimensions are not binding. RC GROUP S.p.A. reserves the right for changes and /or modifications without notice.