FULL RANGE EXPERTISE FIRE PUMPS FOR EVERY STANDARD

Similar documents
FIRE PROTECTION SYSTEMS FULL RANGE EXPERTISE. Vertical Turbine Fire Pumps UL and FM approved GRUNDFOS FIRE PROTECTION SYSTEMS

Reliable, effective, and powerful fire protection

Ruhrpumpen Fire Systems

GRUNDFOS FIRE PUMP SYSTEMS PEERLESS ENGINEERED SYSTEMS LISTED

Fire Protection Pumps

SECTION FIRE PUMP AND CONTROLS

Advanced Technology for Superior Protection

University of Houston Master Construction Specifications Insert Project Name SECTION FIRE PROTECTION PUMPS PART 1 - GENERAL

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. Open Impeller ASME (ANSI) B73.1 Pump for continuous use in Chemical Process Services

SECTION Fire Pumps

Davron Equipment are the appointed agents for the Patterson range of pumps for fire protection in Sub Saharan Africa.

P.C. Simonton & Associates, Inc. Consulting Engineers. Paul C. Simonton

SPRINKLER SYSTEM SOLUTIONS. Water-based Fire-Fighting Sprinkler System PROVEN TECHNOLOGY

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

FAIRBANKS NIJHUIS FIRE PROTECTION. FIRE PUMP SETS & PUMP PACKAGES

FAIRBANKS NIJHUIS FIRE PROTECTION. FIRE PUMP SETS & PUMP PACKAGES

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y LS BARGE PUMP. Vertical high-flow pump

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y VTP. Vertical Turbine Pump

Abu Dhabi Conformity Assessment Scheme for Fire Pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. In-Line Pumps IIL / IVP / IVP-CC

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.

FTA200-A REMOTE ALARM PANEL

Sprinklers in Europe known problems and misconceptions. Alan Brinson

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

SECTION ELECTRIC-DRIVEN, FIRE PUMPS

DIESEL Engine Fire Pump Controllers Features

Fire Protection of Hotels. With SEM-SAFE High-Pressure Water Mist System

Advanced FireAlarm Panel 1-4Loop

Aeon International Ltd Blenheim House, Falcon Court Preston Farm Industrial Estate Stockton on Tees TS18 3TS, United Kingdom

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

Differences Among Screw Plug Immersion Heaters

Setting the Standard in Third-party Certification

9 Standards, Regulations and Authorities

DIESEL Engine Fire Pump Controllers Features

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

IMMERSIBLE PUMPS FOR INDUSTRY

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

FTA550 JOCKEY PUMP CONTROLLERS

SECTION FIRE PUMPS 1.00 PART 1 & GENERAL Description of Work. A. Provide pumps for fire suppression Section Includes

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

Data Booklet EN12845 BREN TYPE FIREFIGHTING BOOSTER SET. Brentas Ltd

PLUMBING HEATING GAS INDUSTRIAL ACTUATION HYDRONICS COMMITMENT TO QUALITY SPECIFICATIONS

Building Services Brochure

Plad Equipment Ltd. A Canadian Company

B. Section Transfer Switches: Automatic transfer switch.

Rotary Blowers COMPACT Series With the world-renowned OMEGA PROFILE Air delivery 0.5 to 93 m 3 /min Pressure up to 1000 mbar, Vacuum to 500 mbar

Sioux E-Series. All-Electric Compact Industrial Steam Cleaners & Pressure Washers. Sioux E-Series All-Electric Steam Cleaners and Pressure Washers

How 1 is your resistance. wire sized? What grade of magnesium oxide is being used? How 3 is your cold pin attached to your resistance wire?

Full-line Product Overview

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

ACCURATE PREDETERMINED COST

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Distributed By: M&M Control Service, Inc Building Technologies

GRUNDFOS WaterPRO. Fire Pumps. GRUNDFOS WaterPRO SEPTEMBER ProductFocus MORE INSIDE

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. ASME/ANSI B73.1 Chemical Process Pump

Mission Critical. Fuel Supply Systems

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

Fire Pump Specification

CLA-VALTM. Fire Protection Solutions: Automatic Control Valves for protecting life and property. For Commercial and Offshore Applications

Blockpumps. Vogel Series LSB. Lenntech. Tel Fax

Transfer Switch Features

Drawing Submittal Package

Solutions at every turn.

US$ 350 for a single warranty claim

IMMERSION HEATERS GAS AND BSP

LaserFOCUS VLF-250 Engineering Specification

Condensate Drain Valves

FieldLink Cable solutions for Automation & Drives

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

Technical Guidance CE Marking of Metal Chimneys and Flues

Semiconductor Solutions. Your global source for industrial automation, control, and power distribution products and services

FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Owner/Operator Guide for Successful Sprinkler and Fire Pump Systems

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

MADE IN ITALY. thermowatt.com. the heart of electric appliances

THE WORLD LEADER. in special hazard fire suppression solutions

Fire Suppression Systems

Fire Pump Systems In Accordance With TS EN A2 Standard

swp Self-priming pump for solids handling applications

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Güntner Info. finoox technology. fin and tube heat exchangers. Tailor-made solutions!

Swiftclean and ANSUL. AXA s Commercial Kitchen Fire Safety Service. Ansul is a leading brand of Johnson Controls International PLC

Drawing Submittal Package

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

LMR Electric Fire Pump Controllers Features

TYPE LF/LC/LCV END SUCTION PUMPS

Transcription:

GRUNDFOS FIRE PROTECTION SYSTEMS Grundfos is a full-line fire system supplier that fully complies with a globally recognised list of approvals and listings. We design, manufacture and service our fire pump systems all over the world, and our products are renowned for their quality, high performance and reliability. Grundfos application areas: Industrial plants Public water supply District cooling / heating plants Air-con / heating systems Fire protection Cooling systems Irrigation GRUNDFOS FIRE protection SYSTEMS FULL RANGE EXPERTISE FIRE PUMPS FOR EVERY STANDARD 96982928 09 GRUNDFOS Management A/S Poul Due Jensens Vej 7 DK-88 Bjerringbro Tel: +45 87 14 00 www.grundfos.com

INTRODUCTION Grundfos fire pumps supply high-class safety to clients around the world. Our expertise spans the globe and covers all UL-FM approved fire systems With Grundfos as your fire system supplier, you can rest assured that your system lives up to the highest international standards of quality. We have products that comply with your every need and the following approvals: PSB VNIIPO CCCF APSAD CEPREVEN VdS UNI LPCB EN 12845 CNBOP FM UL NFPA WE have DOUBLED UP THE KNOW-HOW Two experts for the price of one Grundfos is a proud company with an extensive history of pump manufacturing and innovation. In order to further develop our expertise within fire systems, we ve recently acquired another proud company with a famous -year history in the fire pump industry the American pump icon, Peerless. Peerless has extensive experience with fire pumps of the NFPA standard and FM-UL approved systems. It is also a company that shares the Grundfos values of superior quality products, strong customer focus, and an in-depth understanding of the realities of fire protection. Global presence Grundfos secures efficient and direct deliveries to the construction sites of all our European customers, and with a sales and service centre in every market, Grundfos is never far away. Our competence centre SERVICE AND EXPERTISE We cover the world in Wahlstedt, Germany, is at the heart of fire competence in Europe. Here we manufacture and test FM and VdS approved systems. Comprehensive on-site design, testing and a full range of customer training facilities are also provided. Local assembly sites & competence centres 53 sales companies

versatility RELIABILITY ACROSS THE FULL RANGE Supreme performance UL-listed and FM-approved Full-line supplier Grundfos produces fire pump systems for: Fire hose reels Fire hydrants Fire sprinklers Secondly, approved systems provide maximum reliability and superior quality. Thirdly, using approved and listed fire pumps typically reduces insurance rates significantly. When third party approval is not required for a fire Grundfos provides top performance electric and diesel systems with all the relevant listings and approvals. Our European regional competence centres for fire pumps produce systems manufactured to most local approvals including the NFPA pamphlet code, which is listed by UL (Underwriters Laboratories) and approved by FM (Factory Mutual). The systems can be supplied as either electric or diesel systems. Below, you can see the standard performance range of our electric and diesel pumps. We design and build systems ranging from simple pump-driver systems on a base frame to highly pump installation, Grundfos can supply non-listed fire systems that comply with specific fire standards. Performance range of electric fire pumps Hz Performance range of diesel fire pumps engineered and fully enclosed, packaged systems. We are proud to have the widest range of fire pump H [m] p [psi] H [m] p [psi] approvals and listings worldwide, and our expertise 0 0 enables us to engineer, produce, stock, distribute and service our products all over the world. There are three main reasons for choosing fire pumps that are approved and certified by accredited third party authorities. Firstly, based on the massive experience embodied in leading fire protection, 70 1 1 70 1 1 regulations and codes, approved systems reduce the risk of damage to life and property in the case of fire. 2 0 0 0 00 00 00 Q [US GP M] 2 0 0 0 00 00 00 Q [US GP M] 0 0 0 0 0 Q [m /h] 0 0 0 0 0 Q [m /h] Electric fire pump units are built in two different configurations: Compact: Fire pump and electric motor complete Diesel fire pump units are built in three different configurations: Compact: Complete diesel fire pump unit including system mounted on one base including wiring and control panel. fire pump, diesel engine, fuel tank, batteries and control panel on one base frame. Note: this configuration is not available for all fire Flex: Fire pump and electric motor mounted on base and control panel separately supplied for wall or floor mounting. pump sizes, since the fuel tank is too big for the largest diesel engines. Flex: Same as compact, but with separately mounted fuel tank and control panel. Wall or floor mounted. Flex B: Same as Flex, but with the control panel mounted on a base frame.

The details Electric Fire pump FM approved Electric motor Power safety factor and high reliability Grundfos IEC motor accepted by FM High reliability Grundfos IEC motor accepted by FM UL Listed motor for Fire Electric fire pump controller FM approved controllers as standard with CE-mark designed to comply with NFPA 70 Standard NEMA 2 enclosure corresponds to IP 42 Micro-processor based logic and pressure/event recorder (printer) as standard s and CSA approval Starting options : Star delta, part winding, soft start, auto transformer USB communication port (7 days event and 15 days pressure) Diesel Fire pump FM approved Diesel motor FM approved John Deere motor with industrial silencer and flexible exhaust Power safety factor is per NFPA To ensure optimal performance, each diesel fire pump set is tested at our test bed at rated flow after final pump assembly Engine is cooled by a heat exchanger to ensure proper operation Residential silencer Other engine brands Fuel tank Designed and sized according to NFPA Single wall as standard Single wall with collection basin Double wall tank Diesel fire pump controller FM approved controllers with CE-mark as standard Standard NEMA 3R enclosure, corresponding to IP 24 Thru-the-door thermal printer for 7-day pressure / 15 day event recorder date retrieval Simple start-up and maintenance procedures Coupling Flexible pin coupling design from Flender, accepted by FM Maximum operational reliability (fail-safe) Prevents shaft stress by compensating for shaft mis-alignment Coupling Flexible pin coupling design from Centraflex, accepted by FM Maintenance free Allows shaft movement in axial, radial and angular directions Maximum operational reliability (fail-safe) UL listed couplings Battery set Fire pump FM approved to NFPA as standard Factory performance and hydrostatic tested Designed for highest efficiency, easy maintenance and service Quick delivery pump programme for end-suction and split-case models Available as in-line and vertical turbine pumps With ANSI flanges (End Suction pumps with DIN flanges as standard) for fire Adapters for DIN flanges Base frame Welded frame with a rigid design that ensures easy alignment on-site for driver, fire pump and controller Standard non-drip frame (open) Lifting points for easy transportation Painted in red RAL 00 paint Fire pump FM approved as standard Factory performance and hydrostatic tested Designed for highest efficiency, easy maintenance and service Quick delivery pump programme in end-suction and split-case models In-line and vertical turbine pumps Adapters for ANSI or DIN flanges FM authorised Base frame Two battery sets (lead acid) 24 volt provide redundant power supply and ensure full reliability Sized according to NFPA Nickel cadmium batteries Welded frame with a rigid design that ensures easy alignment on-site for driver, fire pump and controller Drip rim base (closed) as standard Lifting points for easy transportation Painted in red RAL 00 paint The FM logo ensures that the diesel fire pump is assembled with FM approved components and at an OEM and FM approved and authorised manufacturing facility

Customised solutions Beyond standard products Case references At Grundfos, we have always considered a complex project a great challenge. That is why we offer completely customised solutions that match the requirements of even the most complicated tasks. Expanded quick delivery programme Our quick delivery programme contains more than the electrically or diesel-driven End Suction and Horizontal Split Case pumps. We also supply: In-Line fire pumps Vertical Turbine pumps (for wet pit applications, or applications where positive inlet pressure is not available) Modularised systems Grundfos designs and builds customised systems that meet your specific needs. We mount the fire pump, driver, controller and piping with complete interconnected wiring on a common base or a modularised base frame for final assembly on location. Packaged / containerised systems With Grundfos enclosed systems, your installation- to-operation time is minimal. Our enclosed systems are typically built as an integrated pump and control centre with: Diesel engine All the required controllers In-house piping Fittings Interconnected wiring A complete installation that meets the requirements of UL, FM, NFPA 13 and NFPA European projects with Grundfos FM fire systems Project Name Location Country Application Equipment Hotel Beach Vilamoura Portugal Tourist resort Two electric end-suction IKEA Matosinhos Portugal Warehouse Duplex GDF Montoir France Power plant Electric vertical turbine SATO Athens Greece Industrial plant Duplex Hager Athens Greece Warehouse Duplex Jumbo Limassol Cyprus Warehouse Duplex ThyssenKrupp Terni Italy Industrial plant Diesel split case Pinewood Campus Wokingham England Office block Diesel end-suction Kohler Mira Cheltenham England Factory Diesel split case Henkel Istanbul Turkey Industrial plant Diesel split case Belchatow Power, Lodz When Alstom Power built its new power plant in Belchatow near Lodz in Poland, it chose Grundfos to deliver the hydrant and sprinkler installations for the fire fighting system, because we offered a complete solution with pumps, controls and accessories built into a common base plate. Pumps installed: 2 x FK0-1/3-JU6H-UF pump set with fuel tank, controller and engine all mounted together 1 x CR3-15 A-A-A-E-HQQE 3x2/0 HZ 1 x UL/FM LISTED JOCKEY PUMP STARTER A back-up plan: the Grundfos duplex system has both a electric engine and an diesel engine for extra safety.

CUSTOMER SUPPORT FULL-LINE includes THE SUPPORT AS WELL Grundfos service is not limited to delivering a product. We are there all the way from design, installation, maintenance and training. We are particularly proud of our RAPID system. RAPID is a comprehensive electronic product selection programme that provides unique assistance in the design phase of a project. The programme features the following benefits: Enables sales offices to quickly and accurately select the adequate pump systems for your needs Generates quotations with all the necessary commercial and technical information Forwards the full design submittal information to our business partners With RAPID, your project is one step ahead from the beginning. EXPERTISE AT THE HEART OF EUROPE Grundfos Wahlstedt the European competence centre The Grundfos fire competence centre located in the northern part of Germany, sets the scene for a collection of activities that all promote the technology, production and knowledge behind great fire protection systems. The Wahlstedt centre features: Production, assembly, and test facilities approved by FM and VdS Quality accreditations such as ISO 9001, 101, 101, and EMAS Witness tests where customers can supervise the testing of their products Stock facilities for pumps, motors, engine units, and control panels Customer support facilities for applications, system design, logistics, sales and service